AEE
PWD Electrical Sub Division Tvpm
GENERAL-Rest House Thycaud-Reception Room-Construction of First Floor Balance Works, Washing area near Old block and Air conditioning works in New block-Providing EI-Electrical AC Work
2026_PWD_849683_2
ESDT/ET-3/2026-27
Open Tender
Electrical Works
Percentage
90 days
PWD Electrical Sub Division Tvpm
please refr tender documents
5 documents required · 5 mandatory
₹725
₹8,197
1 Aug 2026
25 May 2026
5 Jun 2026
25 May 2026
3 Jun 2026
25 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SITC of AC units | |||||
| 1.001 | OD341919/2025-2026:Supply, installation, testing and commissioning of wall mounting type split air conditioner unit of tonnage 2.0 TR or cooling capacity 6000W, with minimum ISEER of 5.0 ( 5 star), single phase split type AC unit conforming to IS fitted with rotary compressor operating on 230V single phase AC supply, R410A /non CFC refrigerant capable of performing functions like cooling, dehumidifying, air circulating, filtering etc of following capacity, microprocessor control with cordless remote control etc with comprehensive maintenance contract up to the end of 36 months from date of commissioning including periodical services, gas topping etc. complete. Make:- Blue star/Daikin/LG/Mitsubishi/O-General/Hitachi or equivalent. (including stand) | - | each | 69,581.11 | - |
| 1.002 | OD341917/2025-2026:Supplying, installation, testing and commissioning of 1.5 TR and ISEER value grater than or equal to 5, inverter type split air conditioner unit complying to IS: 1391: 1992 (Part-I & II) with up-to-date amendments complete with indoor unit ,outdoor unit (condenser and evaporator coil shall be of copper) etc. and operating on R410A / R32 refrigerant gas, 230V,50 Hz, single phase AC supply, capable of performing :- a. Cooling b. Dehumidifying. Air Circulating. d. Filtering including providing wireless remote control unit, 3 metre copper refrigerent piping , wiring, drain pipe for condensate drain water all insulated with nitrile tubing from indoor unit complete and including with factory made powder coated stand etc . Blue star/Daikin/LG/Mitsubishi/O-General/Hitachi or equivalent. (including stand) | - | each | 60,448.36 | - |
| 1.003 | OD341915/2025-2026:Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.:- 1/4 inch (6.35 mm) and 5/8 inch (15.875 mm) 22 gauge | - | metre | 1,298.35 | - |
| 1.004 | OD341916/2025-2026:Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.:- 1/4 inch (6.35 mm) and 1/2 inch (12.7mm) 22 gauge as required. | - | each | 988.62 | - |
| 1.005 | OD341918/2025-2026:Supply Installation Testing & Commissioning of following size insulated pvc drain pipe from
IDU drain pans to nearest floor drain complete with interconnection ,flanges,elbows, tees,
nuts,U trap etc.The insulation shall be 6 mm thick closed Nitrile Rubber foam insulation 25
MM | - | metre | 147.65 | - |
| 1.006 | 90.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top | - | each | 125.15 | - |
| 1.007 | 90.6.5.19:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm | - | metre | 140.66 | - |
| 1.008 | OD370412/2025-2026:Supply Installation Testing and Commissioning of 16.5 Ltr Capacity Floor mounted UV Technology type water purifier, including dispense of ,hot, cold and ambient water delivering the Hot water 83 deg.c to 85 deg.c, Cold water - 10 deg.c to 18 deg.c and Ambient temperature condition. the unit shall be made by good graded plastic material having minimum 11 Ltr purified water storage tank capacity and 4 Ltr Cold water storage tank capacity and 1.5 Ltr hot water storage tank capacity the unit shall be conveyed and installed in the convenient location with using suitable CP hose and electrical code wire with plug top etc as. required including one year free service (Aqua Guard or its equivalent make ) | - | each | 62,134.74 | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1441055.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
Specificondtionsac-1.pdf
Additional Documents • 0.08 MB
BOQ_1441055.xls
BOQ • 0.31 MB
viewsbd.pdf
Additional Documents • 1.63 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .