| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹99.9 LAccepted-AOC KERALA KL | ₹99.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹1.0 CrRejected-Finance | ₹1.0 Cr | L2 | Rejected-Finance WORK AWARDED TO L1 BIDDER |
| Sl No | Description | Qty | Unit | MRSCO BUILDERS PVT LTD L2 | AHAMAD MASHOOD K L1 |
|---|---|---|---|---|---|
| 1.00Appendix A: Civil Work | |||||
| 1.00 | OD284775/2025-2026:Putting up ring bund of top width 1.50m, bottom width 2.75m.and average height of 2.50m
with 1:1/4 side slope and protect the sides with coconut post of 4.50m long driving down
2.00m below bed level at 75cm c/c, providing 3 rows of weiling pieces 1/4 split coconut post
on both sides and 1/4 split cross ties to alternate posts at top, bottom and middle portion
and screening the sides of bund with Seperation memebrane of impermeable plastic sheet
125 micron thick fixed properly using coconut post and weiling pieces using reeper and nails
in full height including tying properly using iron wire and coir altogether and supply and
filling inside with hard clay/cut earth up to 2.50m, levell and conveyed with all leads and
lifts including consolidating properly and maintaing the bund till the work is completed and
dismantling the bund after completion of work etc. as per the directions of departmental
officers at site. | 72 | metre | 3,751.97 ₹2,70,141.7 | 3,617.03 ₹2,60,426.07 |
| 1.00 | OD284840/2025-2026:Deepening kayasl by using
sand pumps mounted on barges or any other suitable
method and dumping the spoil with a flow rate of
500m3 slurry per hour with a solid output of not less
than 75 m3/hour at location already pointed out by the
departmental officers with a lead up to a radial
distance of 500m, including hire charges of sand pump,
all tools and plants and accesories , fuel charges,idling
and mobilisation charges, providing and shifting the
pipe lines including all labour charges ,incidental
charges and service tax etc. complete for a depth upto (-
) 3.50m with a tolerance of ± 20cm. | 800 | cum | 355.98 ₹2,84,781.12 | 343.17 ₹2,74,538.99 |
| 1.00 | OD284730/2025-2026:Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-35 of
specified diameter and length below the pile cap, to carry a safe working load not less than specified,
excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and
temporary casing of appropriate length for setting out and removal of same and the length of the pile to be
embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel
technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with
all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). Note: Truck
Mounted rotary/TMR/Tubewell boring machine shall not be used . 600 mm dia pile | 320 | metre | 4,750.14 ₹15,20,044.99 | 4,579.3 ₹14,65,376.71 |
| 1.00 | OD285640/2025-2026:Fabricating MS casing 600mm inside diameter using 6mm or nearest thick MS
plates, conveying to the place of driving, hoisting and plumbing in position for driving
including all labour charges of tools and equipment | 56.79 | quintal | 27,716.75 ₹15,74,062.04 | 26,719.92 ₹15,17,451.04 |
| 1.00 | 20.6.2.2:Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.
Single pile above 50 tonne and upto 100 tonne capacityRoutine test (Test Load 1.5 times the Safe capacity) | 1 | per test | 43,609.04 ₹43,609.04 | 42,040.64 ₹42,040.64 |
| 1.01 | 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) | 0.35 | cum | 9,043.49 ₹3,165.22 | 8,718.25 ₹3,051.39 |
| 1.01 | 60.7.2:DR PACKING Under foundation - Dry stone packing under foundation with good quality blasted rubble including conveyance of material and labour charges etc. complete as per direction of departmental officers at site. | 20 | cum | 3,382.6 ₹67,651.93 | 3,260.94 ₹65,218.84 |
| 1.01 | 60.7.1:DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site | 35 | cum | 4,552.54 ₹1,59,339.05 | 4,388.81 ₹1,53,608.44 |
| 1.01 | 5.33.1.2:Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement
All work upto plinth levelConcrete of M30 grade with minimum cement content of 350 kg /cum | 73.63 | cum | 12,616.48 ₹9,28,939 | 12,162.73 ₹8,95,529.79 |
Tender Value
₹90.9 L
EMD Value
₹50,000
Closing Date
4 Feb 2026, 5:00 pmClosed
CHIEF ENGINEER, KSCADC
KSCADC Building, Kamalewsaram , Manacaud P.O. Thiruvananthapuram Pin-695009
PMMSY-Integrated Modern Coastal Fishing Village- Arattupuzha , Alappuzha Fisheries related Eco Tourism Activities-Construction of Boat Jetty -General Civil Work
2026_SCADC_831262_1
ET-95/2025-26
Open Tender
Civil Works - Buildings
180 days
Arattupuzha, Alappuzha District
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,950
₹50,000
13 Apr 2026
28 Jan 2026
6 Feb 2026
28 Jan 2026
4 Feb 2026
28 Jan 2026
Appendix A: Civil Work
OD284775/2025-2026:Putting up ring bund of top width 1.50m, bottom width 2.75m.and average height of 2.50m with 1:1/4 side slope and protect the sides with coconut post of 4.50m long driving down 2.00m below bed level at 75cm c/c, providing 3 rows of weiling pieces 1/4 split coconut post on both sides and 1/4 split cross ties to alternate posts at top, bottom and middle portion and screening the sides of bund with Seperation memebrane of impermeable plastic sheet 125 micron thick fixed properly using coconut post and weiling pieces using reeper and nails in full height including tying properly using iron wire and coir altogether and supply and filling inside with hard clay/cut earth up to 2.50m, levell and conveyed with all leads and lifts including consolidating properly and maintaing the bund till the work is completed and dismantling the bund after completion of work etc. as per the directions of departmental officers at site.
OD284840/2025-2026:Deepening kayasl by using sand pumps mounted on barges or any other suitable method and dumping the spoil with a flow rate of 500m3 slurry per hour with a solid output of not less than 75 m3/hour at location already pointed out by the departmental officers with a lead up to a radial distance of 500m, including hire charges of sand pump, all tools and plants and accesories , fuel charges,idling and mobilisation charges, providing and shifting the pipe lines including all labour charges ,incidental charges and service tax etc. complete for a depth upto (- ) 3.50m with a tolerance of ± 20cm.
OD284730/2025-2026:Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-35 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). Note: Truck Mounted rotary/TMR/Tubewell boring machine shall not be used . 600 mm dia pile
OD285640/2025-2026:Fabricating MS casing 600mm inside diameter using 6mm or nearest thick MS plates, conveying to the place of driving, hoisting and plumbing in position for driving including all labour charges of tools and equipment
20.6.2.2:Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Single pile above 50 tonne and upto 100 tonne capacityRoutine test (Test Load 1.5 times the Safe capacity)
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
60.7.2:DR PACKING Under foundation - Dry stone packing under foundation with good quality blasted rubble including conveyance of material and labour charges etc. complete as per direction of departmental officers at site.
60.7.1:DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
5.33.1.2:Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement All work upto plinth levelConcrete of M30 grade with minimum cement content of 350 kg /cum
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide
OD40326/2024-2025:Supplying and fixing cast iron bollards (100kg or nearest weight) on the landing jetty, as per drawing,including all cost of materials, labour charges, conveyance etc as per the directions of the dept. officers at site.
OD40327/2024-2025:Supplying and fixing 600mm long 20mm dia foundation bolt with each nuts and washers fixing bollards including all cost, fixing charges etc. complete.
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
OD40324/2024-2025:Supplying and laying Geotextile fabric 120 gram per sqm providing necessary overlaps, all cost, conveyance, labour charges etc complete as approved by Engineer-in-charge.
OD40325/2024-2025:Supplying used tractor tyres at site , punching holes, tying and hanging it in front of the wharf over the facia walls from the mooring rings using 32mm twisted polypropylene ropes including all costof labour, fasteners etc complete
50.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
OD50986/2024-2025: Supplying and fixing stretchable fibre mesh with 15cm width along the RCC- solid block masonry joints to prevent the crack development due to uneven expansion & contraction including all cost of materials, labor, scaffolding etc complete as per the direction of Engineer in charge.
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.48.1:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
51.2.3:Filling with Quarry Muck Filling up low lying and water logged areas with local material/ quarry muck, spreading in layers, leveling the top at site and consolidation by ramming, etc complete for improving the CBR value of subgrade
OD40605/2024-2025:Engaging Mason (brick layer) 1st class for ornamental brick/mason works at site
OD40606/2024-2025:Providing and laying industrial grade antiskid tiles of size 300x300mm with thickness 9mm or nearest with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shades,laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.
11.20.3:Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Dark shade pigment using ordinary cement
9.147C.2:Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealent shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.(Area of door upto 2.50 sqm)
9.147A.3:Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. ( Area of window upto 2.50 sqm).
9.7.7.1:Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:4 mm thick glass pane (weight not less than 10kg/sqm).
10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
OD118158/2025-2026: TRUSS LESS ROOFING -Providing and fixing pre coated -Aluzinc profiled sheet size, shape, and pitch approved by engineer in charge 0.90mm (+-0.05%) total coated thickness with zinc coating 170 grams /sqm as per IS:277, in 550 mpa steel grade 6-8 microns epoxy primer on both side of the sheet and polyester top coated 17-20 microns sheet should have protection film to avoid scratching during transportation and should be supplied in single length up to 22 m or as desired by engineer in charge. Pressure equalization, providing suitable gutter profiles at bottom (if required). This item includes cost of all inputs of designing, labour for fabricating and installation required sizes and required numbers etc. complete. installation of scaffolding and other incidental charges including wastage etc., enabling services, cranes or cradles etc. as described above and as specified. 154.32 m2 sheet required for 131.25 m2 actual area of roof.
OD118157/2025-2026:Supplying and fixing 42 cm plain GI valley gutter sheet 3mm thick including cutting, bending, hoisting and fixing position and applying priming coat of approved steel primer including making necessary connections with rain water pipes etc. complete as directed by engineer at site. For truss less roofing
APPENDIX B- road work
4.1.A.1:Construction of granular sub-base by providing graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with a motor grader on the prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 Grading-I - Plant Mix Method
55.23:Supplying and laying interlocking tile 80mm or nearest size thickness, minimum strength M30 including providing a layer of 6mm aggregate for 5cm thickness, then laying interlock cobbles in lines and levels as per the directions of the departmental officers at site inclusive of all cost & conveyance charges etc. complete.
Soil investigation
56.1.a:Mobilization including transportation of all necessary plant and equipment's and materials of boring, field testing and sampling and demobilization after completing the work - For machine boring
56.11.a:Compilation of all field data with recommendation for a suitable foundation after conducting necessary lab test (report in triplicate) - Machine boring for 5 bore holes.
56.2.a:Setting up boring at each bore hole locations including carrying all necessary plant, equipment and materials of boring and field tests and collection of samples at each bore hole location - For machine boring.
56.3.a.1:Boring with rotary power drilling equipment's in - all types of soil having N value less than 50 excluding hard rock, soft rock or medium rock for strata upto 10m including conducting necessary S.P.T and recovery of undisturbed soil samples at 5m intervals - For ordinary soil.
56.3.b.1:Boring with rotary power drilling equipment's in - all types of soil having N value less than 50 excluding hard rock, soft rock or medium rock for strata next 10m and upto a depth of 20m including conducting necessary S.P.T and recovery of undisturbed soil samples at 5m intervals - For ordinary soil.
56.3.c.1:Boring with rotary power drilling equipment's in - all types of soil having N value less than 50 excluding hard rock, soft rock or medium rock for strata next 10m and upto a depth of 30m including conducting necessary S.P.T and recovery of undisturbed soil samples at 5m intervals - For ordinary soil.
Point Wiring
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Sub-Circuit Wiring
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
OD44680/2024-2025:Supply and fixing of ferrules on wire for circuit identification, as required (Any make approved by CPWD/KPWD/KSCADC) 4sqmm wire
OD44681/2024-2025:Supply and fixing of ferrules on wire for circuit identification, as required (Any make approved by CPWD/KPWD/KSCADC) 1.5 to 2.5sqmm wire
Conduits
90.1.1.1:Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required.20 mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.4:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.40 mm
OD44683/2024-2025:Supply and fixing of flexible conduit of the following size, as required - 20mm
OD129474/2025-2026:Supply and fixing of Conduit Adaptor Male PVC Lock Nut 20/25mm Hole Dia Seal Connect for Conduit Box that connects the pipes and the electrical boxes. With glue to one end of the conduit, connect the conduit and the adapter and tighten the lock nut to the mounting hole of the bottom box. Made of PVC material, the adapter is waterproof, corrosion resistant, and flame retardant.
Switches and Sockets
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
90.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator
90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
OD44684/2024-2025:Supply and fixing of Cable Zip Ties, White (100 mm x 2.5 mm,4" inch) Multi-Purpose Self-Locking Nylon Teeth Grip Cable Ties Cord Management Ties, Plastic Ties for cables, industries, Workshop.
cabling
90.12.6.40:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 10 sq mm
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
OD44682/2024-2025:Supply and fixing of copper grounding clips (shim) 60 mm long x 12 mm wide x 1 mm thick for single compression glands for 4sqmm to 16sqmm cables.
Grounding
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
5.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
Energy Meter Box
OD44686/2024-2025:Supply and installation of weatherproof single/three phase Energy meter box with provision for HRC fuses - 3Nos/1No.., Neutral Link - 1No. and a 4P/DP isolator, made in fiber. Double Door. Including all accessories for installation. Approved Make by CPWD/KPWD/KSCADC
OD44687/2024-2025:Supply and installation of following 2 Way neutral links mounted on DMC/SMC base in panel board/ Energy meter box. Approved Make by CPWD/KPWD/KSCADC - 40A
OD44688/2024-2025:Supply and fixing of HRC Fuse Base with HRC Fuse link (Approved make by CPWD/KPWD/KSCADC) - 40A
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Fittings
90.15.4.3:Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.4.6:Supply Conveyance, installation, testing and commissioning of 70W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
OD44695/2024-2025:Supply and installation of wall washer two-way vertical flush mount LED wall light 10W for outdoor decoration (warm/white), wide voltage range (140-360) V with surge protection of 2.5kV
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Fire and Safety
OD44699/2024-2025:Supply and providing First Aid Box with first aid medicines and accessories. Color: Red & White, Size:11Inch * 13 Inch * 3 Inch (W x D x H). Made from galvanize Metal with 7 Way Processed Powder Coating for Long Lasting. Front Heavy Clear acrylic. 4 Partition for medicines organize with lock and 2 set of key. Top side handle for carry to any where and also Wall Mountable.
OD44700/2024-2025:Supply of Fire Bucket Stand with 2 Bucket and sand. Material : Iron. Ring Handle Mounted
OD44701/2024-2025:Supply and providing laminated First Aid chart duly framed and placed in a conspicuous location for clear vision.
OD44702/2024-2025:Supply, fixing and installation of ABC Powder Type 6 Kg Fire Extinguisher (Red and Black) effective for all types of fire like Class A, B and C types of fires as well as Electrical fires and also ABC Powder Type (Stored Pressure) Fire Extinguisher, Multipurpose uses with 1 Wall Hook and 1 Discharge Pipe. ISI, ISO and CE Certified Product and Multipurpose Uses ABC Type fire extinguisher 6 Kg with 5 years Warranty. (Approved make by CPWD/KPWD/KSCADC)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1396662.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
BOQ_1396662.xls
BOQ • 0.38 MB
Drawing.pdf
Other Document • 0.57 MB
TD950126.pdf
Tender Documents • 3.59 MB
Download all tender documents and submit your bid