Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.1 LAccepted-AOC ANGANWADI NO 33 SUBHASH NAGAR 37 ELENJIMOODER 30 42 MUBBELNADA AVALAULAN 34 SCOORYA NAGAR 22 KODALBONA VENDULALBEIBOUARO ANGANWADI POWDIKOUAM WARD PROJECT NO 612 25 | KANGPOKPI | MANIPUR | 795002 | 1 | Accepted-AOC L1 | |
| 2 | 2₹3.3 L+₹19,249 (6.22%)Rejected-AOC | 2 | Rejected-AOC L2 | |
| 3 | 3₹3.6 L+₹54,685 (17.7%)Rejected-AOC ASSISTANT EXECUTIVE ENGINEER PANTALAM MUNICIPALITY DISTRICT TREASURY ALAPPUZHA | 3 | Rejected-AOC L3 |
Tender Value
₹4 L
EMD Value
₹8,298
Closing Date
27 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
JOBBY.K
JOBBY VILAKKUDY
Annual Plan-Pro.No-295/24- Conference Hall Renovation-Installation of A/C Unit-Vilakkudy GP.-Installation of AC Unit at the Conference Hall.-General Electrical Work
2024_LSGD_691494_1
2024_LSGD_664155_1
Open Tender
Electrical Works
Item Rate
180 days
V
Please refer Tender documents.
7 documents required · 7 mandatory
₹735
Yes
₹8,298
Yes
27 Dec 2024
19 Sept 2024
30 Sept 2024
19 Sept 2024
27 Sept 2024
19 Sept 2024
Amount
Installation of AC Unit at the Conference Hall,Vilakkudy Panchayat Office.
90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point
90.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point
90.10.3.14:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
1.55.1:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A
2.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
OD63791/2024-2025:Supply, Installation, testing and commissioning of Inverter type Air Cooled High Wall mounted Split Air Conditioner of 1.5 TR capacity consisting of high wall mounted type room unit with cordless remote control and one number outdoor condensing unit comprising of energy efficient suitable rotary compressor for operation on single phase, 230 V, 50 Hz supply, fixing the outdoor unit on raised platform as per manufacturers recommendation and fixing of room ( fan Coil) unit on wall up to 10m distance refrigerent copper pipinh with 13mm nitril rubber insulation, providing and making interconnection between room and condenser as per site conditions, comprising of 1" dia drain PVC pipe with insulation 10 m, canvas connection, full electrical cabling from power plug near indoor unit and out door unit, vibration isolation, ODU MS stand, first charge refrigarant gas, min 3 star rating with reputed brand and as per BEE suitable stabilizer with 3 year warranty etc. complete as required . 1.5 TR 3 Star Inverter AC Unit
OD63796/2024-2025:Charges for preparing drawing of the complete electrical installation after completion of the present work and preparing completion report for 3 phase service connection and submitting to the consumer for availing 3 phase service connection/Load regularization
OD63798/2024-2025:Supply, conveyance, installation, testing and commissioning wall mounting fan of 400mm sizes using mounting brackets supplied along with the fan and giving connection with existing wire.
OD63799/2024-2025:Supply and installation of hard drawn 19 G copper refriration piping including 9 mm thick nitrile rubber insulation between each set of indoor & out door units as per specification , all piping inside the room shall be properly supported with MS hanger & clamp and all external piping with UV coating as per specification and drawing etc. complete as required.
OD64224/2024-2025:Supply, conveyance, installation, testing and commissioning of recess mounting 14 W LED down light fittings/Globe light Fittings in open area of all types directly in the existing opening on the fall- ceiling including giving connections with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring etc.as required.(Reputed Brand)
OD65525/2024-2025:32/63 A fuse holder for BS type blade fuses.
OD65526/2024-2025:32/63 A, 230 V, DIN type fuse base.
OD65527/2024-2025:32/63 A, 415 V, 2 way neutral link mounted on DMC/ SMC base.
KPT TRADING AND CONTRACTING COMPANY
Sreekumar P
Bidder Name
Sreekumar P
HARIKRISHNAN G
KPT TRADING AND CONTRACTING COMPANY
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1076708.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .