| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.6 LAccepted-AOC 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹30.5 L+₹1.4 L (4.85%)Rejected-Finance RH NO 06 KARMA KSHETRA HOUSING SOCIETY SECTOR 29 PRADHIKARAN RAVET POST DEHU ROAD 412 101 | NA | NA | 412101 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹33.4 L+₹4.4 L (15.0%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L3 | Rejected-Finance Rejected | |
| 4 | L4₹41.5 L+₹12.4 L (42.8%)Rejected-Finance | L4 | Rejected-Finance Rejected |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
21 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Dehu Road, Pune
GE Dehu Road, Pune
REPAIRS MAINTENANCE OF LT DISTRIBUTION OH UG CABLES AND IMPROVEMENT OF DISTRIBUTION SYSTEM AND ALLIED WORKS EAST AREA UNDER GE DEHU ROAD
2023_MES_598062_1
8762
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Dehu Road, Pune
Pl refer Tender documents
8 documents required · 8 mandatory
₹500
GE Dehu Road, Pune
₹98,000
Yes
24 May 2024
24 May 2023
23 Jun 2023
24 May 2023
21 Jun 2023
7 Jun 2023
Amount
M&L for Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out Soft / loose soil all as specified and directed .
M&L fo Excavation in trenches for erection of poles etc.,n. exc 1.5m wide, exc 1.5m and n. exc 3.0m in depth and getting out in soft / loose soil complete all as specified and directed by Engr-in-charge.
M&L fo Returning, filling in soil, including spreading, levelling watering and well ramming in layers not exceeding 25 cm all as specified and directed.
M&L fo Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point of any type of excavation all as specified and directed by Engineer -in-Charge.
M&L for Taking out LT Cable of any size(10 sqmm 2/4 core to 120 sqmm 3.5 core) for reuse or under Schedule of credit to contractor. Note:- Excavation is not included in quoted rate and will be measured & paid separately.
M&L for Relaying of LT Cable of any size obtained from item no 5 as per site requirement and making connections as specified and directed by Eng in charge. Note:- Excavation is not included in quoted rate and will be measured & paid separately.
M&L for supply ,Laying ,commissioning, testing in repair UG cable XLPE insulated screened PVC bedded ,galvanized steel strip or wire armoured ,electric power cable heavy duty 1100 volts grade with stranded aluminium conductor of following sizes:- Make :- Havells/ Polycab/ Gloster
All as per item no 7 here in before but size of cable 70 Sq mm x 3.5 core
All as per item no 7 here in before but size of cable 50 Sq mm x 3.5 core
All as per item no 7 here in before but size of cable 35 Sq mm x 3.5 core
All as per item no 7 here in before but size of cable 25 Sqmm x 4 Core
All as per item no 7 here in before but size of cable 16 Sqmm x 4 Core
All as per item no 7 here in before but size of cable 10 Sqmm x 4 Core
All as per item no 7 here in before but size of cable 16 Sqmm x 2 Core
All as per item no 7 here in before but size of cable 10 Sqmm x 2 Core
All as per item no 7 here in before but size of cable 95 sqmm X 3.5 core
All as per item no 7 here in before but size of cable 120 sqmm X 3.5 core
M&L for Taking out HDPE DWC Pipe of any size for reuse or under Schedule of credit to contractor. Note:- Excavation is not included in quoted rate and will be measured & paid separately.
M&L for Relaying of HDPE DWC pipe of any size obtained from item no 8 as per site requirement as specified and directed by Eng in charge. Note:- Excavation is not included in quoted rate and will be measured & paid separately.
M & L in repair HDPE DWC pipe ISI Marked fixed on walls, ceilings or in floors, trenches etc. for cable protection of the following outer dia :- Make:-Infra/Supreme/Prince
All as per item no 10 here in before but size of cable 40 mm dia
All as per item no 10 here in before but size of cable 50 mm dia
M& L for GI tubing 50 mm dia light grade for cable protection
M & L for Dismantling and Restringing OH line of ACSR conductors of any description which includes replacement 22 SWG aluminium binding wire,removing jumper connections, reconnection of binding wire & jumper connections after restringing complete upto the satisfaction of Engr-in-Charge. NOTE :- Each conductor span shall be measured & paid as one RM length.
M&L for Taking down the unserviceable ACSR/ABC cable of any size from pole, structure and Supply and fixing 1100V Grade L.T. Aerial Bunched Cable having three Power Core & One Neutral-Cum-Messenger Core of stranded compacted circular Aluminium Black coloured XLPE insulated & Core identification by ridges, one, two and three & four respectively. One Street Lighting Core of stranded, compacted Circular Aluminium Conductor, of size 3x70 + 1x16 + 1x50 sq.mm(Ph. Wire + St. Light Wire + Neutral Wire + Messenger). Messenger- Wire should be of stranded compacted Circular Aluminium Alloy Conductor conforming to IS 8130/1984, IS-398(Part-IV)/1979 and IS-14255/1995 with upto date amendments. Make :Havells,Polycab,Kenter,Jio Note: The cost included the accessories required for drawl of LT overhead line with 1100V GRADE AERIAL BUNCHED CABLES on PCE POLE SUPPORT with the following items included the rate. 1. Anchor Clamp (3-Bolt and 2 Bolt Type) 2. Eye hook with Suspension Clamp Assembly. 3. PCC Pole Clamp. 4. Insulation Piercing Connectors with cover or P.G.Connectors with insulation cover. 5. Water Proof pre-insulated Hexagonal Compression Connectors & Lugs.
M&L for Taking down the unserviceable ACSR/ABC cable of any from pole, structure and Supply and fixing 1100V Grade L.T. Aerial Bunched Cable having three Power Core & One Neutral-Cum-Messenger Core of stranded compacted circular Aluminium Black coloured XLPE insulated & Core identification by ridges, one, two and three & four respectively. One Street Lighting Core of stranded, compacted Circular Aluminium Conductor, of size 3x50 + 1x16 + 1x35 sq.mm(Ph. Wire + St. Light Wire + Neutral Wire + Messenger-). Messenger- Wire should be of stranded compacted Circular Aluminium Alloy Conductor conforming to IS 8130/1984, IS-398(Part-IV)/1979 and IS-14255/1995 with upto date amendments. Make :Havells,Polycab,Kenter, Jio Note:The cost included the accessories required for drawl of LT overhead line with 1100V GRADE AERIAL BUNCHED CABLES on PCE POLE SUPPORT with the following items included the rate. 1. Anchor Clamp (3-Bolt and 2 Bolt Type) 2. Eye hook with Suspension Clamp Assembly. 3. PCC Pole Clamp. 4. Insulation Piercing Connectors with cover or P.G.Connectors with insulation cover. 5. Water Proof pre-insulated Hexagonal Compression Connectors & Lugs.
M&L for dismantling the unserviceable ACSR Conductor of any type and supply & Fixing ACSR conductor of any size all as directed
M&L for Dismantling and taking down insulators of any size from dismantled/existing LT poles of any type or description complete all as specified and directed.
M & L for LT insulator, PIN type 1100 volts as per IS 1445, grade of size 100mm height, 65mm dia, porcelain, vitreous, white or brown including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut including taking down existing unserviceable insulator all as directed. Make;- Elpro or equivalent.
Fixing only LT insulator, PIN type, 1100 volts grade of size 100mm height, 65mm dia, porcelain, vitreous, white or brown including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut including taking down existing unserviceable insulator all as directed. Make;- Elpro or equivalent.
Fixing only shackle type insulator as per IS 1445 working pressure in 1100 volts, 100mm height, 115mm dia porcelain, vitreous, white or brown insulator including galvanised mild steel straps of size 31x5mm, washers, insulator bolts of size 14mm dia, washers and nuts, including taking down of u/s shackle insulators complete all as directed by Engr-in-charge.
M & L for shackle type insulator as per IS 1445 working pressure in 1100 volts, 100mm height, 115mm dia porcelain, vitreous, white or brown insulator including galvanised mild steel straps of size 31x5mm, washers, insulator bolts of size 14mm dia, washers and nuts, including taking down of u/s shackle insulators complete all as directed by Engr-in-charge.
M&L for Dismantling and taking down MS cross arms, bracing supports, clamps, back plates, hooks etc fabricated from structural steel section from dismantled/existing LT poles of any type or description complete all as specified and directed.
Fixing only MS cross arms, bracing supports, clamps, back plates, hooks etc fabricated from structural steel section from dismantled/existing LT poles of any type or description complete all as specified and directed.
M&L cross arms, bracing supports, clamps, back plates, hooks etc fabricated from structural steel section (MS channel, angle sections, flat, round or square bars ) for reqd sizes and shape including bolts nuts & washers welding bending cutting cold or hot drilling holes for inserting in any shape or size as indicated or directed complete incl painting ( one red oxide primer coat two coats of aluminium paint ) complete.
M&L for Taking down and S&F in repairs synthetic / PVC line separators of LT OH lines with nut,bolts & washers straight type horizontal configuration fixed at a point as directed and suitable for single phase 2 wire LT lines
S&F in repairs synthetic / PVC line separators of LT OH lines with nut,bolts & washers straight type horizontal configuration fixed at a point as directed and suitable for three phase 4 wire LT lines
M&L for preparing old painted steel surfaces by scrubbing with wire brush and applying two coats of aluminium paint to 9 mtr long LT steel tubular poles complete with connected fittings such as brackets, cross arms, metal portion etc and stick computer cut sticker radium number on the pole with of suitable high letters on 10 cm x 10 cm square block with black enamelled paint complete all as directed by Engineer-in-Charge
M&L for Taking down unserviceable pole and Supply & erect in repair in position steel tubular pole swaged type as per IS 2713 complete with MS base plate finial tapper plug cap bolt, nut, screws etc all as specified for swaged pole of type 410 SP 31 , 09 mtrs long incl painting with two coats of aluminium paint over a coat of red oxide paint all as directed including removing existing pole. ( Note :- Excavation and earth work and PCC in foundation shall be measured and paid separately) Make : Electrosteel/ Indian Pole/ Singh Profiles/ Kalki tubes & Poles
M&L for Taking down unserviceable pole Supply & erect in repair in position steel tubular pole swaged type as per IS 2713 complete with MS base plate finial tapper plug cap bolt, nut, screws etc all as specified for swaged pole of type 410 SP 55 , 11 mtrs long incl painting with two coats of aluminium paint over a coat of red oxide paint all as directed including removing existing pole. ( Note :- Excavation and earth work and PCC in foundation shall be measured and paid separately) Make : Electrosteel/ Indian Pole/ Singh Profiles/ Kalki tubes & Poles
M&L for Demolition of PCC coping , base , etc any type
M&L for provision of PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M & L for plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in plinth, platforms, pole coping etc., all as specified and as directed.
M & L for plain cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in plinth, platforms, pole coping etc., all as specified and as directed.
S&F in repair GI Wire 4 mm dia fixed on LT/HT Poles
M & L in repairs for earthing with galvanised steel earth plate electrode 60cmx60cmx6.3mm buried directly in ground earth pit not less than 2.25 m deep below normal ground level with top edge of the plate vertically to depth of not less than 1.2m below ground level connected to and including GI strip of size 25 x 4 mm as earthing lead welded with earth electrode (excluding GI protection pipe) and connecting to equipments by means of earthing lead connecting to equipments by means of GI bolts & nuts etc. with provision of char-coal and salt etc. all as per electrical plate No. 3 of SSR Part I, 2009 including RCC cover and MS angle iron frame watering arrangement with GI pipe 20mm dia (medium grade) & MS funnel, concrete pit including excavation and earthwork and testing on completion etc complete all as specified and directed by Engr-in-Charge. Note: Rate quoted deemed to be including excavation by compressor M/C for Soft disintegrated rock to required depth.
S&F for Taking down unserviceable MCCB and Supply & fix in repair MCCB 400 Amp, 4 pole, 415 V,Thermal Adjustable – 0.8 to 1In, Magnetic Adjustable** – 5 to 10In.with breaking capacity 36 KA ,Ics=100% Icu. Make : LEGRAND/ ABB/Schneider
S&F for Taking down unserviceable MCCB and Supply & fix in repair MCCB 200 Amp, 4 pole, 415 V,Thermal Adjustable – 0.8 to 1In, Magnetic Adjustable** – 5 to 10In.with breaking capacity 25 KA ,Ics=100% Icu. Make : LEGRAND/ ABB/Schneider
S&F for Taking down unserviceable MCCB and Supply & fix in repair MCCB 160 Amp, 4 pole, 415 V,with breaking capacity 16 KA ,Ics=100% Icu. Make : LEGRAND/ ABB/Schneider/HPL
S&F for Taking down unserviceable MCCB and Supply & fix in repair MCCB 125 Amp, 4pole, 415 V,with breaking capacity 16 KA ,Ics=100% Icu. Make : LEGRAND/ ABB/Schneider/HPL
S&F for Taking down unserviceable MCCB and Supply & fix in repair MCCB 100 Amp, 4 pole, 415 V,with breaking capacity 16 KA ,Ics=100% Icu. Make : L&T /LEGRAND/ ABB/Schneider/HPL
S&F for Taking down unserviceable MCCB and Supply & fix in repair MCCB 63 Amp, 4 pole, 415 V,with breaking capacity 16 KA ,Ics=100% Icu. Make : LEGRAND/ ABB/Schneider/HPL
M & L for Danger Notice plate 1.6 mm thick mild steel sheet vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour, Write 'LT SUPPLY 440 Volts 'and fixed with MS clamps bolts and nuts of approved size for LT 15x10 cms Complete
S&F in repair Smart Integrated Solar All In One with > 140Lum/W, 09 Watt power Rating, MPPT Charge Controller, Tiltable LED panel,Including Lithium battery Adjustable AIO mounting angle, Monocrystalline Solar Panel, PIR motion Sensor, easy to install. MAKE :- Crompton,Havells,Bajaj,Jaquar
M&L for Taking down unserviceable GI pipe street light pole ,supply and installed hot dip Galvanized octagonal pole of height 7 mtr, top70 mm, and bottom 135 mm ,Top 70 mm made with 3mm thick Mounting base plate 250x Plate,fix on PCC foundation with foundation bolt 700mm long 250x12 mm with four nos foundation bolts with washer of size 16mm dia and 600mm long mm bolt,including street light bracket single arm minimum expose length 1.5 mtrr length from poles withe pole cape complete as per manufacturer design.(PCC for foundation measured and paid in respected sch a"A" items)
Supply & fix cable jointing kit for 1100V XLPE grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable complete all as specified and directed by Engineer-in-Charge. Make :- M-Seal/ Densons/ Dowells
All as item no 39 here in before but size of cable 10 to 16 sqmm,3.5/4 core
All as item no 39 here in before but size of cable 25 to 30 sqmm,3.5/4 core
All as item no 39 here in before but size of cable 70 to 95 sqmm,3.5/4 core
All as item no 39 here in before but size of cable 120 to 150 sqmm,3.5/4 core
M & L to find out fault location in 11000 V /415 V UG Cable of any size by using cable fault locator directed by all as specified and directed by Eng in charge. Note:-Contractor must bring cable fault locator at site within 24 hours of intimation otherwise recovery @ Rs 1000/Hr will be charged after 24 hours.
M&L for repair of LT distribution panel that includes welding to panel doors,reconnection of defective electrical connections(incoming and outgoing cables),cleaning of inner and outer surfaces,painting of inner and outer surfaces,reconnection of cables coming from transformers ,Replacement of defective voltmeters&ammeters ,Providing of Cable glands, spraying of Pesticides to remove gross, and cleaning & well surfacing of Transformer sorroundings all as specified and directed by Eng in Charge.
S&F in repair On load change over switch 415V,4 pole with current capacity 200 amp. MAKE:-C02004PEAV of HPL/Standard/Havells or Equivalent.
S&F in repair On load change over switch 415V,4 pole with current capacity 160 amp. MAKE:- C01604PEAV of HPL/Standard/Havells or Equivalent.
S&F in repair On load change over switch 415V,4 pole with current capacity 100 amp. MAKE:- CDC01004PEAVHPL/Standard/Havells or Equivalent.
Supply and providing Electrician with helper for repair the unserviceable street light fittings from the street light poles and refixing the same in existing position including testing after repair complete all as directed. Note: (a)Necessary spare,fitting,excavation other related work will be measured in respective items. (b) Necessary tools,ladder ,safety equipment for electrician and helper will be arrange by the contractor in his own cost. (c) Taking down and refixing is also including the cost .
Supply and providing Electrician with helper for repair the unserviceable Gate lights/ post top lantern lights /Garden light/ building security light from the walls/Gates/Lamp posts for repairs and refixing the same in existing position including testing after repair complete all as directed. Note: (a)Necessary spare,fitting,excavation other related work will be measured in respective items. (b) Necessary tools,ladder ,safety equipment for electrician will be arrange by the contractor in his own cost. (c) Taking down and refixing is also including the cost .
M&L for Taking down the unserviceable garden light fitting of any type and supply and fixing of integral decorative LED post-top 25W 5700K energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire all as directed. make Bajaj or equivalent Havells,Philips
Supply and fix in replacement of fibre looping box with connector and MCB SP 2 to 6 Amps of size 250x200x100 mm including making connections all as specified and directed by .Make - United / National / Sintex
M&L for Taking down the unserviceable flood light luminaire 120W 5700K (WB) with high pressure die cast housing with IP66,surge protection light 100 watt natural warm white, all as directed. make:Havells, Bajaj Philips
M&L for Taking down unserviceable street light fitting and supply and fixing LED street light fittings 60W 5700K with DPD energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with necessary Bracket 50 mmGI Pipe with extended arm ,with Clamp ,nut& Bolts complete all as directe.Make:Havells, Bajaj,Philips
M&L for Taking down unserviceable street light fitting and supply and fixing LED street light fittings 70W 5700K with DPD energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with necessary Bracket 50 mmGI Pipe with extended arm ,with Clamp ,nut& Bolts complete all as directe.Make:Havells, Bajaj,Philips
M&L for Taking down unserviceable street light fitting and supply and fixing LED street light fittings120W Neo N 5700K with DPD energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with necessary Bracket 50 mmGI Pipe with extended arm ,with Clamp ,nut& Bolts complete all as directe.Make:Havells, Bajaj,Philips
S&F in replacement of rigid non metallic PVC conduit 20mm dia exclusive of boxes ( junction/terminal) but inclusive of all Tees / bends /elbows/reducer/bell mouth tubes ends and fixing accessories coupler , lock nuts , saddles , pipe hook etc
Supply only PVC insulated and unsheathed cable of size 1.5 Sqmm single core multistranded copper conductor FR cable 1100 V grade confirming to IS 694
Supply and fixing Reflector adhesive tape 25 mm with suitable for fixing in street light pole of colour red all as directed.
M&L for Taking down unserviceable Aluminium cable lug 120 sqmm and supply with fixing the same all as directed. Make:-Dewel,M-Seal
M&L for Taking down unserviceable Aluminium cable lug 95 sqmm and supply with fixing the same all as directed. Make:-Dewel,M-Seal
M&L for Taking down unserviceable Aluminium cable lug 70 sqmm and supply with fixing the same all as directed. Make:-Dewel,M-Seal
M&L for Taking down unserviceable Aluminium cable lug 50 sqmm and supply with fixing the same all as directed. Make:-Dewel,M-Seal
M&L for Taking down unserviceable Aluminium cable lug 35 sqmm and supply with fixing the same all as directed. Make:-Dewel,M-Seal
M&L for Taking down unserviceable Aluminium cable lug 25 sqmm and supply with fixing the same all as directed. Make:-Dewel,M-Seal
M&L for Taking down unserviceable Aluminium cable lug 16/10 sqmm and supply with fixing the same all as directed. Make:-Dewel,M-Seal
Shri Sai Electricals
metro electrical services
Mahindra Electric Stores
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .