Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-AOC | ₹5.6 L | L1 | Accepted-AOC L1 |
| 2 | L2₹5.7 LRejected-AOC KOTTATHARA SOCIETY | IDUKKI | KERALA | 685501 | ₹5.7 L | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | RENJITH K L1 | ABDUL MUNEER N K L2 |
|---|---|---|---|---|---|
| 1.00Annual Maintenance | |||||
| 1.00 | OD238997/2025-2026:carpenter 2nd class | 4 | each | 1,196.35 ₹4,785.40 | 1,200 ₹4,800 |
| 1.00 | OD238999/2025-2026:Engaging coolies for miscellaneous work | 70 | Day | 1,080.73 ₹75,651.10 | 1,100 ₹77,000 |
| 1.00 | OD238998/2025-2026:Cleaning drain and removing vegitation and solid waste | 100 | metre | 111.86 ₹11,186 | 120 ₹12,000 |
| 1.00 | 18.51.1:Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore | 3 | each | 887.18 ₹2,661.54 | 890 ₹2,670 |
| 1.00 | OD238996/2025-2026:Desludging the existing septic tank, deposit the sludge into the excavated pit and refill the pit including all labour and hire charges etc. complete. | 57 | cum | 2,205.98 ₹1.3 L | 2,250 ₹1.3 L |
| 1.01 | 50.18.7.3.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall | 10 | metre | 301.48 ₹3,014.80 | 320 ₹3,200 |
| 1.01 | 50.18.7.6.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall | 15 | metre | 429.29 ₹6,439.35 | 430 ₹6,450 |
| 1.01 | 50.18.9.20.3:Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Door Elbow | 3 | no | 88.31 ₹264.93 | 90 ₹270 |
| 1.01 | 50.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow | 3 | no | 117.63 ₹352.89 | 120 ₹360 |
Tender Value
₹5.2 L
EMD Value
₹12,999
Closing Date
30 Jan 2026, 11:00 amClosed
Assistant Executive Engineer PWD Buildings Subdivi
O/o Assistant Executive Engineer PWD Buildings Subdivision Kalpetta
GENERAL-Running Contract 2025-26- Rest Houses and Watchman Quarters-Running contract works at resthouse vythiri,meppadi and watchman quarters of the respective resthouses at Wayanad.-General Civil Work
2026_PWD_829823_1
PWD/BLDG/TR/22494/2025_5_1_1/1
Open Tender
Civil Works - Buildings
365 days
VYTHIRI
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,150
Yes
₹12,999
Yes
25 Mar 2026
22 Jan 2026
2 Feb 2026
22 Jan 2026
30 Jan 2026
22 Jan 2026
Annual Maintenance
OD238997/2025-2026:carpenter 2nd class
OD238999/2025-2026:Engaging coolies for miscellaneous work
OD238998/2025-2026:Cleaning drain and removing vegitation and solid waste
18.51.1:Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
OD238996/2025-2026:Desludging the existing septic tank, deposit the sludge into the excavated pit and refill the pit including all labour and hire charges etc. complete.
50.18.7.3.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall
50.18.7.6.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall
50.18.9.20.3:Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Door Elbow
50.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow
50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend
9.63.3:Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : (Copper oxidized as per IS : 1378)150x10 mm
14.6.1:Renewing glass panes, with wooden fillets wherever necessary: Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)
9.63.1:Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : (Copper oxidized as per IS : 1378)250x10 mm
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2.33.1:Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth
50.2.33.6:Cutting branches of trees overhanging above any structures of girth between 60cm to 90cm including stacking of serviceable materials and disposal of unserviceable material, cost of labour, hire charges of rope and pully etc without making any damages to nearby structures etc complete
18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
17.2.1:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid
17.7.2:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
12.47.1:Providing & fixing UV stabilised fibre glass reinforced plastic sheet rooting up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8 mm dia G.I plain/ bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovings incorporating minimum 0.3% ultra-violet stabiliser in resin system under approxirnately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866. The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified.2 mm thick corrugate 2.5"or 4.2" or 6") or step-down (2' or 3" or 6") as specified.
9.51.2:Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.With 12 mm mild steel U beading
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1393715.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.09 MB
viewnit.pdf
Tender Documents • 0.07 MB
viewsbd.pdf
Tender Documents • 1.64 MB
BOQ_1393715.xls
BOQ • 0.31 MB
5docuFPIAE.pdf
Tender Documents • 0.67 MB
performance.pdf
Tender Documents • 0.41 MB
Download all tender documents and submit your bid