Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.8 LAccepted-AOC | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹31.5 L+₹5.7 L (22.0%)Rejected-Finance | L2 | Rejected-Finance Being L2 |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
21 Aug 2020, 6:00 pmClosed
HQ CWE AF AMBALA
HQ CWE AF AMBALA
CA NO CWE/AF AMB/HAL-25/2020-21 REPAIR / MAINTENANCE OF CENTRAL TYPE AC PLANT AND LAUNDRY PLANT AT AF STN HALWARA UNDER GE (AF) HALWARA
2020_MES_361992_1
CA NO CWE/AF AMB/HAL-25/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
GE AF HALWARA
All contractors enlisted with MES in Class D and above and Category c i and for unenlisted refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE AF HALWARA
₹68,000
Yes
12 Sept 2020
18 Jul 2020
24 Aug 2020
18 Jul 2020
21 Aug 2020
8 Aug 2020
18 Jul 2020 - 29 Jul 2020
Amount
Dismantling including taking down/out unserviceable central type AC plant compressor of 21TR capacity.Make -Voltas, Model : 5H40 including opening complete unit,repairing the crank shaft, remetling, grinding , polishing,checking of cyclinder bore with and including replacement of unserviceable parts such as pistons set, connecting rod, shaft seal assembly, discharge/suction reeds, big end bearing, small end bush set, gasket packing etc and re-assembling of the complete compressor unit and testing etc complete all as specified and as directed . Notes :- (i) Spare parts required for replacement shall be measured and paid separately as supply only in replacement under the respective items. The spares shall be of same make/model as per existing.(ii) Rate quoted are deemed to be included for draining out the compressor oil and refilling with same oil. Fresh compressor oil if required, shall be measured and paid separately .
Supply only in replacement compressor gasket suitable for central type AC plant compressor of 21 TR capacity of Make -Voltas & Model : 5H40, complete all as specified and directed.
Supply only in replacement piston assembly including piston with pin suitable for central type AC plant compressor of 21 TR capacity of Make -Voltas & Model : 5H40, complete all as specified and directed..
Supply only in replacement lock ring (circlip), oil ring, piston ring compression suitable for central type AC plant compressor of 21 TR capacity of Make -Voltas & Model : 5H40, complete all as specified and directed.
Supply only in replacement seal end & pump end bearing including washer suitable for central type AC plant compressor of 21 TR capacity of Make -Voltas & Model : 5H40, complete all as specified and directed.
Supply only in replacement discharge valve guide assembly of central type AC plant compressor of 21 TR capacity of Make -Voltas & Model : 5H40, complete all as specified and directed.
Suuply only in replacement big end bearing half section of connecting rod (set of two ) suitable for central type AC plant compressor of 21 TR capacity of Make -Voltas & Model : 5H40, complete all as specified and directed.
Supply only in replacement main bearing seal end suitable for central type AC plant compressor of 21 TR capacity of Make -Voltas & Model : 5H40, complete all as specified and directed.
Supply only in replacement valve plate suitable for central type AC plant compressor of 21 TR capacity of Make -Voltas & Model : 5H40, complete all as specified and directed.
Supply only in replacement suction valve disk suitable for central type AC plant compressor of 21 TR capacity of Make -Voltas & Model : 5H40, complete all as specified and directed.
Supply only in replacement discharge valve guide lock washer suitable for central type AC plant compressor of 21 TR capacity of Make -Voltas & Model : 5H40, complete all as specified and directed.
Supply only in replacement unloader sleave suitable for central type AC plant compressor of 21 TR capacity of Make -Voltas & Model : 5H40, complete all as specified and directed.
Supply only in replacement suction valve spring suitable for central type AC plant compressor of 21 TR capacity of Make -Voltas & Model : 5H40, complete all as specified and directed.
Supply only in replacement snap ring for liner suitable for central type AC plant compressor of 21 TR capacity of Make -Voltas & Model : 5H40, complete all as specified and directed.
Supply only in replacement pin and spring for valve lifter suitable for central type AC plant compressor of 21 TR capacity of Make -Voltas & Model : 5H40, complete all as specified and directed.
Supply only in replacement shaft seal cover plate suitable for central type AC plant compressor of 21 TR capacity of Make -Voltas & Model : 5H40, complete all as specified and directed.
Supply only in replacement shaft key suitable for central type AC plant compressor of 21 TR capacity of Make -Voltas & Model : 5H40, complete all as specified and directed.
Supply only in replacement relief valve suitable for central type AC plant compressor of 21 TR capacity of Make -Voltas & Model : 5H40, complete all as specified and directed.
Supply only in replacement oil screen package suitable for central type AC plant compressor of 21 TR capacity of Make -Voltas & Model : 5H40, complete all as specified and directed.
Supply only in replacement unloader power assembly suitable for central type AC plant compressor of 21 TR capacity of Make -Voltas & Model : 5H40, complete all as specified and directed.
Supply only in replacement pump package, bushing, oil pressor regulator suitable for central type AC plant compressor of 21 TR capacity of Make -Voltas & Model : 5H40, complete all as specified and directed.
Supply only in replacement hydraulic relay and magnetic plug suitable for central type AC plant compressor of 21 TR capacity of Make -Voltas & Model : 5H40, complete all as specified and directed.
Supply only in replacement cylinder liner suitable for central type AC plant compressor of 21 TR capacity of Make -Voltas & Model : 5H40, complete all as specified and directed.
Supply only in replacement suction and discharge shut off valve suitable for central type AC plant compressor of 21 TR capacity of Make -Voltas & Model : 5H40, complete all as specified and directed.
Supply only in replacement bellow assembly suitable for central type AC plant compressor of 21 TR capacity of Make -Voltas & Model : 5H40, complete all as specified and directed.
Supply only in replacement external valve assembly suitable for central type AC plant compressor of 21 TR capacity of Make -Voltas & Model : 5H40, complete all as specified and directed. Note for item 1.01 to 1.25 :- The spares shall be fitted against item No 01 for 21 TR capacity compressor & same shall be of existing make/model.
Dismantling including taking down/out unserviceable reciprocating type compressor of capacity 20 TR central AC plant .Make -Accel Model : SMC-6-65 including opening complete unit,repairing the crank shaft, remetling, grinding , polishing,checking of cyclinder bore with and including replacement of unserviceable parts such as pistons set, connecting rod, shaft seal assembly, discharge/suction reeds, big end bearing, small end bush set, gasket packing etc and re-assembling of the complete compressor unit and testing etc complete all as specified and as directed . Notes :- (i) Spare parts required for replacement shall be measured and paid separately as supply only in replacement under the respective items. The spares shall be of same make/model as per existing.(ii) Rate quoted are deemed to be included for draining out the compressor oil and refilling with same oil. Fresh compressor oil if required, shall be measured and paid separately .
Supply only in replacement piston assembly suitable for central type AC plant compressor of 20 TR capacity of Make -ACCEL & Model ; SMC-6-65, complete all as specified and directed.
Supply only in replacement Gudgeon pin with bush suitable for central type AC plant compressor of 20 TR capacity of Make -ACCEL & Model ; SMC-6-65, complete all as specified and directed.
Supply only in replacement small end bearing of connecting rod suitable for central type AC plant compressor of 20 TR capacity of Make -ACCEL & Model ; SMC-6-65, complete all as specified and directed.
Supply only in replacement big end bearing of connecting rod suitable for central type AC plant compressor of 20 TR capacity of Make -ACCEL & Model ; SMC-6-65, complete all as specified and directed.
Supply only in replacement main bearing (front & rear) of connecting rod suitable for central type AC plant compressor of 20 TR capacity of Make -ACCEL & Model ; SMC-6-65, complete all as specified and directed.
Supply only in replacement suction and discharge reeds including tension springs suitable for central type AC plant compressor of 20 TR capacity of Make -ACCEL & Model ; SMC-6-65, complete all as specified and directed.
Supply only in replacement oil pump suitable for central type AC plant compressor of 20 TR capacity of Make -ACCEL & Model ; SMC-6-65, complete all as specified and directed.
Supply only in replacement shaft seal assembly suitable for central type AC plant compressor of 20 TR capacity of Make -ACCEL & Model ; SMC-6-65, complete all as specified and directed.
Supply only in replacement 'O' ring set suitable for central type AC plant compressor of 20 TR capacity of Make -ACCEL & Model ; SMC-6-65, complete all as specified and directed.
Supply only in replacement compressor gasket suitable for central type AC plant compressor of 20 TR capacity of Make -ACCEL & Model ; SMC-6-65, complete all as specified and directed.
Supply only in replacement liner with suction valve suitable for central type AC plant compressor of 20 TR capacity of Make -ACCEL & Model ; SMC-6-65, complete all as specified and directed.
Supply only in replacement safty valve assembly suitable for central type AC plant compressor of 20 TR capacity of Make -ACCEL & Model ; SMC-6-65, complete all as specified and directed.
Supply only in replacement discharge valve assembly suitable for central type AC plant compressor of 20 TR capacity of Make -ACCEL & Model ; SMC-6-65, complete all as specified and directed.
Supply only in replacement suction valve assembly suitable for central type AC plant compressor of 20 TR capacity of Make -ACCEL & Model ; SMC-6-65, complete all as specified and directed.
Supply only in replacement connecting rod assembly suitable for central type AC plant compressor of 20 TR capacity of Make -ACCEL & Model ; SMC-6-65, complete all as specified and directed. Note for item 2.01 to 2.15 :- The spares shall be fitted against item No 02 for 20 TR capacity compressor & same shall be of existing make/model.
Dismantling including taking down/out unserviceable reciprocating type compressor capacity 15 TR Make Kirloskar Modal FK-4 including opening complete unit,repairing the crank shaft, remetling, grinding , polishing,checking of cyclinder bore with and including replacement of unserviceable parts such as pistons set, connecting rod, shaft seal assembly, discharge/suction reeds, big end bearing, small end bush set, gasket packing etc and re-assembling of the complete compressor unit and testing etc complete all as specified and as directed . Notes :- (i) Spare parts required for replacement shall be measured and paid separately as supply only in replacement under the respective items. The spares shall be of same make/model as per existing.(ii) Rate quoted are deemed to be included for draining out the compressor oil and refilling with same oil. Fresh compressor oil if required, shall be measured and paid separately .
Supply only in replacement piston assembly suitable for central type AC plant compressor of 15TR capacity of Make -Kirloskar & Model ; FK-4, complete all as specified and directed.
Supply only in replacement Gudgeon pin with bush suitable for central type AC plant compressor of 15TR capacity of Make -Kirloskar & Model ; FK-4, complete all as specified and directed.
Supply only in replacement small end bearing of connecting rod suitable for central type AC plant compressor of 15TR capacity of Make -Kirloskar & Model ; FK-4, complete all as specified and directed.
Supply only in replacement big end bearing of connecting rod suitable for central type AC plant compressor of 15TR capacity of Make -Kirloskar & Model ; FK-4, complete all as specified and directed.
Supply only in replacement main bearing (front & rear) of connecting rod suitable for central type AC plant compressor of 15TR capacity of Make -Kirloskar & Model ; FK-4, complete all as specified and directed.
Supply only in replacement suction and discharge reeds including tension springs suitable for central type AC plant compressor of 15TR capacity of Make -Kirloskar & Model ; FK-4, complete all as specified and directed.
Supply only in replacement oil pump suitable for central type AC plant compressor of 15TR capacity of Make -Kirloskar & Model ; FK-4, complete all as specified and directed.
Supply onlySupply only in replacement shaft seal assembly suitable for central type AC plant compressor of 15TR capacity of Make -Kirloskar & Model ; FK-4, complete all as specified and directed.
Supply only in replacement 'O' ring set suitable for central type AC plant compressor of 15TR capacity of Make -Kirloskar & Model ; FK-4, complete all as specified and directed.
Supply only in replacement compressor gasket suitable for central type AC plant compressor of 15TR capacity of Make -Kirloskar & Model ; FK-4, complete all as specified and directed.
Supply only in replacement liner with suction valve suitable for central type AC plant compressor of 15TR capacity of Make -Kirloskar & Model ; FK-4, complete all as specified and directed.
Supply only in replacement safty valve assembly suitable for central type AC plant compressor of 15TR capacity of Make -Kirloskar & Model ; FK-4, complete all as specified and directed.
Supply only in replacement discharge valve assembly suitable for central type AC plant compressor of 15TR capacity of Make -Kirloskar & Model ; FK-4, complete all as specified and directed.
Supply only in replacement suction valve assembly suitable for central type AC plant compressor of 15TR capacity of Make -Kirloskar & Model ; FK-4, complete all as specified and directed.
Supply only in replacement connecting rod assembly suitable for central type AC plant compressor of 15TR capacity of Make -Kirloskar & Model ; FK-4, complete all as specified and directed. Note for item 3.01 to 3.15 :- The spares shall be fitted against item No 03 for 15 TR capacity compressor & same shall be of existing make/model.
Dismantling including taking down/out unserviceable semi hermetic reciprocating type compressor capacity 30 TR Make Carrier Modal 06E-6299611 including opening complete unit,repairing the crank shaft, remetling, grinding , polishing,checking of cyclinder bore with and including replacement of unserviceable parts such as pistons set, connecting rod, shaft seal assembly, discharge/suction reeds, big end bearing, small end bush set, gasket packing etc and re-assembling of the complete compressor unit and testing etc complete all as specified and as directed . Notes :- (i) Spare parts required for replacement shall be measured and paid separately as supply only in replacement under the respective items. The spares shall be of same make/model as per existing.(ii) Rate quoted are deemed to be included for draining out the compressor oil and refilling with same oil. Fresh compressor oil if required, shall be measured and paid separately .
Supply only in replacement Piston set with Pin,liner, ring, sleeve suitable for central type AC plant Semi-Hermetic reciprocatiing compressor of 30TR capacity of Make -Carrier & Model : 06E-6299611, complete all as specified and directed.
Supply only in replacement Crank shaft suitable for central type AC plant Semi-Hermetic reciprocatiing compressor of 30TR capacity of Make -Carrier & Model : 06E-6299611, complete all as specified and directed.
Supply only in replacement Oil Pump suitable for central type AC plant Semi-Hermetic reciprocatiing compressor of 30TR capacity of Make -Carrier & Model : 06E-6299611, complete all as specified and directed.
Supply only in replacement main bearing suitable for central type AC plant Semi-Hermetic reciprocatiing compressor of 30TR capacity of Make -Carrier & Model : 06E-6299611, complete all as specified and directed.
Supply only in replacement connecting rod with pin suitable for central type AC plant Semi-Hermetic reciprocatiing compressor of 30TR capacity of Make -Carrier & Model : 06E-6299611, complete all as specified and directed.
Supply only in replacement Wall Plate suitable for central type AC plant Semi-Hermetic reciprocatiing compressor of 30TR capacity of Make -Carrier & Model : 06E-6299611, complete all as specified and directed.
Supply only in replacement Suction, Discharge, Oil Ring suitable for central type AC plant Semi-Hermetic reciprocatiing compressor of 30TR capacity of Make -Carrier & Model : 06E-6299611, complete all as specified and directed.
Supply only in replacement Suction & Discharge lead suitable for central type AC plant Semi-Hermetic reciprocatiing compressor of 30TR capacity of Make -Carrier & Model : 06E-6299611, complete all as specified and directed.
Supply only in replacement Gasket suitable for central type AC plant Semi-Hermetic reciprocatiing compressor of 30TR capacity of Make -Carrier & Model : 06E-6299611, complete all as specified and directed. Note for item 4.01 to 4.09 :- The spares shall be fitted against item No 4 for 30 TR capacity compressor & same shall be of existing make/model.
S&F in replacement piston assembly suitable for central type AC plant compressor of 12.5 TR capacity of Make -ACCEL & Model ; SMC-4-65, complete all as specified and directed.
S&F in replacement Gudgeon pin with bush suitable for central type AC plant compressor of 12.5 TR capacity of Make -ACCEL & Model ; SMC-4-65, complete all as specified and directed.
S&F in replacement small end bearing of connecting rod suitable for central type AC plant compressor of 12.5 TR capacity of Make -ACCEL & Model ; SMC-4-65, complete all as specified and directed.
S&F in replacement big end bearing of connecting rod suitable for central type AC plant compressor of 12.5 TR capacity of Make -ACCEL & Model ; SMC-4-65, complete all as specified and directed.
S&F in replacement main bearing (front & rear) of connecting rod suitable for central type AC plant compressor of 12.5 TR capacity of Make -ACCEL & Model ; SMC-4-65, complete all as specified and directed.
S&F in replacement suction and discharge reeds including tension springs suitable for central type AC plant compressor of 12.5 TR capacity of Make -ACCEL & Model ; SMC-4-65, complete all as specified and directed.
S&F in replacement oil pump suitable for central type AC plant compressor of 12.5 TR capacity of Make -ACCEL & Model ; SMC-4-65, complete all as specified and directed.
S&F in replacement shaft seal assembly suitable for central type AC plant compressor of 12.5 TR capacity of Make -ACCEL & Model ; SMC-4-65, complete all as specified and directed.
S&F in replacement 'O' ring set suitable for central type AC plant compressor of 12.5 TR capacity of Make -ACCEL & Model ; SMC-4-65, complete all as specified and directed.
S&F in replacement compressor gasket suitable for central type AC plant compressor of 12.5 TR capacity of Make -ACCEL & Model ; SMC-4-65, complete all as specified and directed.
S&F in replacement liner with suction vlave suitable for central type AC plant compressor of 12.5 TR capacity of Make -ACCEL & Model ; SMC-4-65, complete all as specified and directed.
S&F in replacement safty valve assembly suitable for central type AC plant compressor of 12.5 TR capacity of Make -ACCEL & Model ; SMC-4-65, complete all as specified and directed.
S&F in replacement discharge valve assembly suitable for central type AC plant compressor of 12.5 TR capacity of Make -ACCEL & Model ; SMC-4-65, complete all as specified and directed.
S&F in replacement suction valve assembly suitable for central type AC plant compressor of 12.5 TR capacity of Make -ACCEL & Model ; SMC-4-65, complete all as specified and directed.
S&F in replacement connecting rod assembly suitable for central type AC plant compressor of 12.5 TR capacity of Make -ACCEL & Model ; SMC-4-65, complete all as specified and directed.
Material & Labour for carrying out the descaling of the shell & Tube condensers by isolation of each condenser by providing of dummy plate for inlet & outlet connection and separation of condenser from water circulation without disturbing the operation of the AC plant of capacity 25/30 TR, carrying out the descaling by circulation of the diluted scale removing agent organic compound type chemical of RA III / chemtex Brand at the appropriate ratio depend upon the scale deposit inside copper tube by forced circulation and opening the end covers, manually brushing the copper tubes with nylon brushes of various size to remove complete scale, de-greasing with caustic soda solution and flushing out with fresh water, refixing all disconnected pipes lines, end covers with new rubber gasket and opening water line valves and checking of water leakages, apply grease to all M.S. Bolts & Nuts and put the condensers of the following capacities in operational complete all as specified and directed.
All as per Ser No 5 here-in-before but for AC plant of capacity 40/50 TR complete all as specified and directed.
All as per Ser No 5 here-in-before but for AC plant of capacity 60/100 TR complete all as specified and directed.
M&L for descaling air cooled type condensers of pakage/ductable type ACs capacity 5 TR to 11 TR with cleaning acid by forced feed method to remove the dust particles formed on the coil and fins complete all as specified & as directed.
M&L for cleaning & servicing of FRP cooling tower of central type AC plant of cap 25 TR to 100 TR, removal of water tray, pipe line and cleaning of cooling tower fins by using brush.omplete all as directed.
Dismantling ,taking down/out and opening of monoblock pump set , capacity 3 HP ,of any make / type,at any location, for repairs , including cleaning , descaling , greasing , oiling and overhauling, replacement of gland packing, bush, ball bearing with & including by providing new one, re-assembling and installing the pump set at original location after testing complete all as specified and as directed.
Dismantling ,taking down/out and opening of monoblock pump set , capacity 5 HP to 7.5 HP ,of any make / type,at any location, for repairs , including cleaning , descaling , greasing , oiling and overhauling, replacement of gland packing, bush, ball bearing with & including by providing new one, re-assembling and installing the pump set at original location after testing complete all as specified and as directed.
Dismantling ,taking down/out and opening of monoblock pump set , capacity 10 HP ,of any make / type,at any location, for repairs , including cleaning , descaling , greasing , oiling and overhauling, replacement of gland packing, bush, ball bearing with & including by providing new one, re-assembling and installing the pump set at original location after testing complete all as specified and as directed.
M&L for dismantling and overhauling of condenser/Chiller water pump set of capacity 10 HP, dismantling pump and motor separately, cutting the burnt out winding from slots and rewinding the same by existing size and gauge of super enamalled copper wire including varnishing, heating, repairing the insulating materials, repalcing bearings, bushes and remetalling the shaft including necessary heat treatment , and repairing the pump , including replacing the gland packing , bearings and all rusted nuts and bolts, washers and remetaling the Impeller of suitable size and bore for lifting the water from source and reassembling the motor and pump with gland packing includings painting of pump amd motor assambly complete with two coats of super enameled paints over one coats of red oxide, fixing the motor & pump at its position and connecting the suction and delivery water pipe and testing under working conditions, complete all as specified and directed.
All as per Ser No 13 here-in-before but of capacity 7.5 HP complete all as specified and directed.
All as per Ser No 13 here-in-before but of capacity 5 HP complete all as specified and directed.
All as per Ser No 13 here-in-before but of capacity 3 HP complete all as specified and directed.
All as per Ser No 13 here-in-before but of capacity 1 HP complete all as specified and directed.
M&L for repair and servicing to squirrel cage induction motor 3 phase 415V, 40 HP by dismantling of motor from the pump set removing the stater/rotor separately, cutting the burnt out winding from slots and rewinding the same by existing size and gauge of super enamalled copper wire including varnishing, heating, repairing the insulating materials, repalcing bearings, bushes and remetalling the shaft including necessary heat treatment. Reassembling the motor and pump with new gland packing, supply and fix new gland nuts, bolts, with gland mounting nuts & bolts washers complete , painting the motor and pumps with two coats of synthetic enamel paint after preparing the surfaces all as directed by Engineer-in-charge. fixing the motor & pump on their own base and connecting the suction and delivery water pipes and testing with proper working condition complete all as directed .
All as per Ser No 18 here-in-before but induction motor of capacity 30 HP complete all as specified and directed.
All as per Ser No 18 here-in-before but induction motor of capacity 20 HP complete all as specified and directed.
All as per Ser No 18 here-in-before but induction motor of capacity 10 HP complete all as specified and directed.
All as per Ser No 18 here-in-before but induction motor of capacity 7.5 HP complete all as specified and directed.
All as per Ser No 18 here-in-before but induction motor of capacity 5 HP complete all as specified and directed.
Pressure testing / leak arresting , vaccuming with dry nitrogen gas at the maximum pressure of 300 to 400 PSI / oil charging, including replacing the unserviceable strainers all as required and testing complete for the Central type AC plant of capacity 25 to 100 TR Capacity at various locations/buildings of tech area and all as specified and directed . Note :- (I) Refregerant Gas R-22/407/410 and strainers shall be measured and paid seperately under suply only items (II) The Nitrigen gas pressure should be not less then 350 PSI during leak arresting of the plants and it will hold the same pressure upto 24 hours and vaccum pressure should not be less then (-30 micron Pressure) during the vaccuming of plants.
Pressure testing / leak arresting , vaccuming with dry nitrogen gas at the maximum pressure of 300 to 400 PSI / oil charging, incl replacing the unserviceable strainers all as required and testing complete for the Package type AC plant of capacity 5.5 TR to 22 TR at any location/building of tech area and all as specified and directed. Note :- (I) Refregerant Gas R-22/407/410/403 will be measured and paid seperately under suply only items (II) The Nitrigen gas pressure should be not less then 350 PSI during Leak arresting of the plants and it will hold the same pressure upto 24 hours and vaccum pressure should not be less then (-30 micron Pressure) during the vaccuming of plants.
Material and Labour for leak testing of AHU unit cooling/heating coil of AC plant after pumping down the complete system, isolating the cooling coil from both ends and charging the dry nitrogen gas for pressure leak test, after detecting leak point, release the nitrogen gas, repairing the leak point by means of soldering/brazing and connecting the cooling coil with system, vaccumised the complete system and re-charge the system by refrigerant, testing and commissioning upto satisfactory cooling performance of the plant complete all as specified and as directed.
Supply only refrigerernt M-22 gas (MEFRON)in 61 Kg company sealed cylinder complete complete all as specified and as directed.
Supply only refrigerernt R-407C gas in 61 Kg company sealed cylinder complete complete all as specified and as directed.
Supply only refrigerernt R-410A gas in 61 Kg company sealed cylinder complete complete all as specified and as directed.
Supply only nitrogen gas in 25 Kg company sealed cylinder complete complete all as specified and as directed. Notes for item No 27 to 30 :- (i) Gas shall be brought by the contractor at Site from authorised dealer/ manufacturer company in sealed cylinder of standard packing with test certificate and purchase Vrs and charging shall be done through OEM only. (ii) The empty cylinder after use shall be returned to the contractor.
M&L for replacement of unserviceable Humidistat including electrical connection complete all as specified & directed.
M&L for replacement of unserviceable heater strip type 3kW capacity as per existing size complete all as specified & directed.
M&L for replacement of unserviceable heater 2/3kW capacity for pan type humidifier and hot water generator as per existing size & model complete all as specified & directed.
M&L for servicing of pan type humidifier floor mounted/ installed at duct of capacity 6 /12 kW including cleaning of tank, checking of all inlet & outlet connection, checking and repair of all electrical control connections and making the pan type humidifier functional including replacement of minor parts as required at site complete all as specified and directed .
Supply and fixing scroll type compressure , three phase 4.5 TR capacity suitable for package type AC plant after taking down/out compressor as existing at site complete all as specified and as directed.
Supply and fixing in replacement scroll type compressure SM185, three phase suitable for central type AC plant 12.5 TR capacity complete all as specified and as directed. Note for item No 35 & 36:- Purchase vouchers and gurantee of two years of compressor from the original manufactuers/authorised dealers shall be obtained and submitted by the contractor while claming payment of compressors.
M&L for spray painting to chilled water type Central Air Conditioning plant of 3X30 TR capacity at S-4 complex Building, including complete compressor, motor, condenser refrigerant pipe, water pipe line, AHU, cooling tower, LT panel board complete plant with two coat of synthetic enamel paint including preparation of surfaces and as per approved colour code complete all as specified and directed.
All as per item No. 37 above but for 3X 24 TR chiller type AC Plant at Base Ops Building.
M&L for spray painting to Central Air Conditioning plant of 3X21 TR capacity at 9AF Hospital Building, including complete compressor, motor, condenser refrigerant pipe, water pipe line, AHU, cooling tower, LT panel board complete plant with two coat of synthetic enamelled paint including preparation of surfaces and as per approved colour code complete all as specified and directed.
All as per item No. 39 above but for 3X 13 TR chiller type AC Plant at NBD & MRB Building.
Servicing of electric control panel/compressure control pannel board by taking out the burnt wire. Supply & fixing new wire of existing specification with clipping and socketing and dressing properly complete all as specified and directed.
Material and labour for Insulation of M S Pipe 32mm dia with PUF slab 25 mm thick including applying bituminuous/CPRX compound and AluminiumI cladding sheet of 26 gauge including taking out old insulation as exist at site complete all as specified and directed.
Material and labour for Insulation of M S Pipe 40mm dia with PUF slab 25 mm thick including applying bituminuous/CPRX compound and AluminiumI cladding sheet of 26 gauge including taking out old insulation as exist at site complete all as specified and directed.
Material and labour for Insulation of M S Pipe 65mm dia with PUF slab 25 mm thick including applying bituminuous/CPRX compound and AluminiumI cladding sheet of 26 gauge including taking out old insulation as exist at site complete all as specified and directed.
Material and labour for Insulation of M S Pipe 100mm dia with PUF slab 25 mm thick including applying bituminuous/CPRX compound and AluminiumI cladding sheet of 26 gauge including taking out old insulation as exist at site complete all as specified and directed.
Supplying and fixing insulation to duct glass wool wrapped with chicken wiremesh and hassian cloth with and including providing 50 mm thick plastering in cement mortar 1: 2 , welding, grinding etc and cleaning the welded portion complete all as specified and as directed.
S&F Ratational moulded polyethene HDPE tank of capacity 2000 ltrs triple layer of white colour, for use as makeup water tank for cooling Tower (cylendrecal vertical with closed top) hoisted and fixed in position of made on iron frame / faricated works including fitting including taking down of tank as existing at site complete all as specified and directed.
S&F Ratational moulded polyethene HDPE tank of capacity 500 ltrs triple layer of white colour, for use as makeup water tank for cooling Tower (cylendrecal vertical with closed top) hoisted and fixed in position of made on iron frame / faricated works including fitting including taking down of tank as existing at site complete all as specified and directed.
S&F in repair liquid line drier suitable for Voltas/Bluestar/carrier AC plant with & including necessary sealing gasket/neoprene gasket/ring as per existing model complete all as specified and as directed.
S&F in repair entering water temperature (EWT) sensor as per existing model & make complete all as specified and as directed.
S&F in repair leaving water temperature (LWT) sensor as per existing model & make complete all as specified and as directed.
Supply and fixing of of PVC fills of size (450x300x150mm), sutaible for any type of cooling tower of central air conditioning plant including taking down of existing fills as exist on site complete all as specified and directed.
Repair/Servicing of electric hot water generator of capacity 25 TR to 60 TR and replacement of defected parts & rewiring of generators by proper connection using thimble, connector and replacement of unserviceable accessories refixing the all items complete all as directed. Note :- (i) The quoted rate shall be deemed to include for the cost of minor parts required for making the generators fully functional and only heating element if required shall be measured and paid separately.
Supply, fixing & testing single phase preventer VSP2/VSP1 having auxiliary supply 415 Volts Bimetal thermal over load relay various ranges starting from 3 Amps to 15 Amps including taking down old one as exist at site complete all as specified and directed.
S&F in replacement Electronic timer star Delta, 240-415V timing 3s-120s as per existing make & model complete all as specified and directed.
S&F in repair, MVPD , range 30-220 Amps ,aux supply 230 VAC for AC Plant complete as per existing make & model complete all as specified and directed.
S&F in repair of Microprocessor controller based operating control board including display,step down transformer & sensor suitable for Model No.WCUR0350MN, Make : Voltas complete all as specified and as directed.
S&F in repair of Microprocessor controller based operating control board including display,step down transformer & sensor suitable for Model No. 30HRC085, Make : Carrier complete all as specified and as directed.
S&F in repair of PCB controller including display,step down transformer & sensor suitable for Model No.- XWC2S-026A,Make- Blue Star complete all as specified and as directed.
S&F in repair of PCB controller including display,step down transformer & sensor suitable for Model No.- DPUAS055Y, Make- Voltas complete all as specified and as directed.
S&F in repair of PCB controller including display,step dowm transformer & sensor suitable for Model No.- DPA 1052R1,Make- Blue Star complete all as specified and as directed.
S&F in repair of PCB controller including display,step down transformer & sensor suitable for Model No.- WCUS1-015,Make- Blue Star complete all as specified and as directed.
S&F in repair power contactor 4 pole for AC circuit with AC Coils voltage 220-240 Volt incluover load relay 16 Amps complete as per existing make & model complete all as specified and as directed.
S&F in repair power contactor 3 pole MLI-5 for AC circuit with AC Coils voltage 240/250 Volt including over load relay 25 Amps complete as per existing make & model complete all as specified and as directed.
S&F in repair power contactor 4 pole for AC circuit with AC Coils voltage 220-240 Volt ,over load relay 32-40 Amps complete as per existing make & model complete all as specified and as directed.
S&F in repair Safety valve 300 PSI of copper material suitable for 25 TR to 100 TR capacity Central/package type AC plant as per existing make and model complete all as specified and as directed.
S&F in repair HP/LP control switch as per existing make and model complete all as specified and directed.
S&F in repair thermometer suitable for chilled and condenser water pipe line complete all as per existing make and model complete all as specified and directed.
S&F in repair Pressure transistor sensor for suction, discharge & oil complete all as per existing make and model complete all as specified and directed.
S&F in repair Pressure gauge suitable for chilled and condenser water pipe line complete all as per existing make and model complete all as specified and directed.
S&F in repair cooling tower fan motor of capacity 3HP, 3 Phase, 440 Volts and 50/60 Hz and not less than 960 RPM suitable for any type and made of cooling tower, including all accessories like nuts, bults washer and clamps etc and taking down old unserviceable existing one and all as specified and directed.
Supply and fixing in repair cooling Tower aluminium fan blades 1200 mm dia with coupling hub suitable for existing (set of four blades) existing Shape , size and model suitable for 3 HP CT fan Motor and upto 70 TR capacity Cooling tower and all as specified and directed.
Supply fabricate and fixing of MS angle /MS plate/flat/rod for cooling tower frame,CT fan base, cooling tower ladders,and all supports made out of suitable size along with welding/MS nuts,bolts and washers, hinges,locking arrangement including painting with two coats of synthetic enamel paint over one coat of red oxide primer including removing existing unserviceable rusted one, all as specified and directed.
Supply and fixing in repair AHU filter suitable for AHU of size (610X610X50mm) as per existing size ,make and model complete all as specified and directed.
Supply and fixing in repair AHU Filter suitable for AHU of size (305X610X50MM) as per existing size ,make and model complete all as specified and directed.
Taking out the blower motor & shaft from the AC plant of capacity 5 TR to 22 TR , rewinding, welding and grinding on lathe machine to make suitable alignment with bearing and refixing on same position complete all as specified and directed.
S&F in repair runner of blower drum for package unit of AC plant of capacity 5.0 TR to 22TR complete all as specified and as directed.
S&F in repair fan blade suitable for air cooled condensor of AC plant of capacity 5 to 22 TR complete all as specified and as directed.
S&F in repair Timer of AC plant of capacity 5.0 TR to 22 TR complete all as specified and as directed.
S&F in repair bearing of blower motor suitable for package units of AC plant of capacity 5.0 TR to 22 TR complete all as specified and as directed.
S&F in repair connector 36 to 40 A, 440 Volt TP & TPN complete all as specified and as directed.
Servicing and Maintenance including minor repairs and making in serviceable condition of the central type AC Plants of 25TR to 100 TR capacity comprising of all minor parts and machineries including charging of R - 410/407/22 Gas and when ever required repair and maint of compressor and chiller,blower motor Air filters de-humidifying coils lt control pannels , PCB, ducts and accessories of all gauges and meters and keeping in perfect working condution all as specified and directed. Note : Refrigerant Gas will be measured and paid seperately under relevent item.
Servicing and Maintenance including minor repairs and making in serviceable condition of the package type AC Plants of 5 TR to 22 TR capacity comprising of all minor parts and machineries including charging of R - 410/407/22 Gas and when ever required repair and maint of compressor and blower motor Air filters de-humidifying coils lt control pannels , PCB, ducts and accessories of all gauges and meters and keeping in perfect working condution all as specified and directed Note : Refrigerant Gas will be measured and paid seperately under relevent items of schudle if any required .
Supply and Charging Lubricating Oil for scroll type compressor with refrigerant R407 Mineral oil 160P complete all as specified and as directed.
Supply and Charging Lubricating Oil for scroll type compressor with refrigerant R22 Mineral oil 160P complete all as specified and as directed.
Supply and Charging Lubricating Oil for bearing, blower motor and outdoor motor complete all as specified and as directed.
S&F in repair non Returning Valve of brass of 80 mm dia PN-10 including gasket, nut bolts washers and connected accessories for proper fixing and complete all as specified and directed.
S&F in repair cast iron butterfly valve of 80 mm dia valve PN-1 0 with SG Iron spindle and Bush of SS-410,with handle for manual operation including gasket, nut bolts and connected accessories, for proper fixing and complete all as specified and directed.
S&F in repair cast iron butterfly valve of 65 mm dia valve PN-1 0 with SG Iron spindle and Bush of SS-410, including gasket, nut bolts and connected accessories for proper fixing and complete all as specified and directed.
S&F in repair cast iron balancing valve of 65/80 mm pipe size for balancing of chilled water/ condenser water pipe line dia valve PN-1 0 including gasket, nut bolts and connected accessories for proper fixing and complete all as specified and directed.
S&F in repair water flow switch for connection to chilled & condenser water pipe line as per existing make & model complete all as per specified and directed.
Supplying, Installing , commissiong and testing for sprinkler assembly with branch pipe alluminium suitable for FRP cooling tower capacity 25TR to 60TR including taking down existing complete all as specified and directed.
S&F in repair digital clock temperature & humidity measuurer complete all as specified and directed.
Supply and fixing in repairs LED indication Lamps for R,Y,B Phase in LT panel boards / feeder pillar boxes including disconnecting and removing existing defective item from electric circuit including necessary connected fastners, burnt cables, accessories etc all as per site requirement and as per existing make/model complete all as specified and directed.
Supply and fixing in repairs Push Button Switches (Red and Green in Colour) in LT panel boards / feeder pillar boxes including disconnecting and removing existing defective item from electric circuit including necessary connected fastners, burnt cables, accessories etc all as per site requirement and as per existing make/model complete all as specified and directed.
Supply and fixing in repair Ammemeter analog type range above 100A below 300A in LT panel boards / feeder pillar boxes including disconnecting and removing existing defective item from electric circuit including necessary connected fastners, burnt cables, accessories etc,. all as per site requirement and as per existing make/model complete all as specified and directed.
Supply and fixing in repair voltmeter Analog type range upto 600Volts in LT panel boards / feeder pillar boxes including disconnecting and removing existing defective item from electric circuit including necessary connected fastners, burnt cables, accessories etc,. all as per site requirement and as per existing make/model complete all as specified and directed.
S&F in repair Air sensor for package type AC plant of 5.0/9.0/11.0/17.0/22 TR capacity, suitable for Blue Star/Voltas AC plant complete all as specified and directed.
S&F in repair coil sensor for package type AC plant of 5.0/9.0/11.0/17.0/22 TR TR capacity, suitable for Blue Star/Voltas AC plant complete all as specified and directed.
S&F in repair fan capacitor of 10+-2% mfd capacity suitable for out door unit of package type AC plant of 5.5/7.5/11.0 TR capacity, suitable for Blue Star/Voltas AC plant complete all as specified and directed.
Supply and fixing in repair 4 Core 10 Sqmm multistrand copper conductor PVC insulated sheathed flexible cable suitable for connection of package/central type AC plant and all as specified and directed.
Supply and fixing in repair 4 Core 6 Sqmm multistrand copper conductor PVC insulated sheathed flexible cable suitable for connection of package/central type AC plant and all as specified and directed.
Supply and fixing in repair 4 Core 4 Sqmm multistrand copper conductor PVC insulated sheathed flexible cable suitable for connection of package/central type AC plant and all as specified and directed.
Supply and fixing in repair MCB TPN 63 Amps for connection of package/central type AC plant as main incommer outgoing complete all as specified and directed.
Supply and fixing in repair MCB TPN 40 Amps for connection of package/central type AC plant and all as specified and directed.
Supply and fixing in repair MCB SPN 40 Amps for connection of package/central type AC plant and all as specified and directed.
Supply and fixing in repair MCB SPN 32 Amps for connection of package/central type AC plant and all as specified and directed.
Supply and fixing in replacement, V belt as per existing size & model complete all as specified and directed.
M&L for replacement of U/S Canvas cloths heavy duty of package/centraltype AC plants including provisiong of zip 150 mm lenth for opening and closing arrangements and properlly fasterners with bolts and nuts between the ducts and dumpers of the plants and all as directed.
Supply and fixing in repair Actuator with smoke & fire sensor for fixing in existing fire damper complete all as specified and directed.
Supply and fixing GI tubing 40mm bore medium grade with all fittings laid in trenches, floor, roof and wall and tank connection complete including cutting and thereading with all fittings like tee, elbow bend union reducer hex nipple complete all as specified and directed.
Supply and fixing GI tubing 32mm bore medium grade with all fittings laid in trenches, floor, roof and wall and tank connection complete including cutting and thereading with all fittings like tee, elbow bend union reducer hex nipple complete all as specified and directed.
Supply and fixing GI tubing 25mm bore medium grade with all fittings laid in trenches, floor, roof and wall and tank connection complete including cutting and thereading with all fittings like tee, elbow bend union reducer hex nipple complete all as specified and directed.
Supply and fixing GI tubing 20mm bore medium grade with all fittings laid in trenches, floor, roof and wall and tank connection complete including cutting and thereading with all fittings like tee, elbow bend union reducer hex nipple complete all as specified and directed.
S&F in repairs gun metal gate valve 40mm bore ISI marked with iron wheel head, screwed both ends for iron pipe of following sizes including taking down the unserviceable complete all as specified and directed.
S&F in repairs gun metal gate valve 32mm bore ISI marked with iron wheel head, screwed both ends for iron pipe of following sizes including taking down the unserviceable complete all as specified and directed.
S&F in repairs gun metal gate valve 25mm bore ISI marked with iron wheel head, screwed both ends for iron pipe of following sizes including taking down the unserviceable complete all as specified and directed.
S&F in repairs gun metal gate valve 20mm bore ISI marked with iron wheel head, screwed both ends for iron pipe of following sizes including taking down the unserviceable complete all as specified and directed.
Supply and fixing in repair PVC Ball valve suitable to fix 40mm bore pipe ISI marked high presssure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed complete all as specified and directed.
Supply and fixing in repair PVC Ball valve suitable to fix 25mm bore pipe ISI marked high presssure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed complete all as specified and directed.
Supply and fixing in repair PVC Ball valve suitable to fix 20mm bore pipe ISI marked high presssure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed complete all as specified and directed.
Supply and fixing in replacement solonoid valve, capacity 9TR to 25TR as per existing size & model complete all as specified and as directed.
Supply and fixing in replacement solonoid valve, capacity 26TR to 60TR as per existing size & model complete all as specified and as directed.
Supply and fixing in replacement expansion valve suitable for 9TR to 25TR as per existing size & model Tonne capacity complete all as specified and as directed.
Supply and fixing in replacement expansion valve suitable for 26TR to 60TR as per existing size & model capacity complete all as specified and as directed.
Comprehensive maintenance of Laundry Plant with following laundry equipments : Washing machine capacity 50-60 Kg-02 Nos,Hydro extractor capacity 25 Kg-02 Nos, Drying tumbler capacity 50-60 Kg-02 Nos,Autoclave machine Capacity 25 Kg- 01 Nos complete all as specified and directed by Engineer-in-Charge Make:- M/s Spectrum Laundry Equipment Company installed at Halwara.
NOTEs:- (i) The Plant Maintenance includes complete maintenance of existing plants by regular and systematically examining for smooth and efficient funtioning of the plants. The contracter shall provide skill trademen with helper to attend to the plant for any problems with the Laundry plant during 0600 to 1800 Hrs as directed. The same shall be rectified within 8 Hours failing which a penalty of Rs 500/ Per day shall be imposed and no payment of work done shall be measured during the period when plant is not workable. (ii) The rates include for replacement of spares in plant if required to be replaced during fortnightly maintenance. (iii) Contractor shall arrange to attend the plant for any problems with the laundry through OEM only.(iv) The above Maintenace shall be carried out through M/s Spectrum Laundry Equipment Company. The requisite agreement in this regard shall be produced to GE. (vi) Replacement of all major/minor defective/spares parts if damaged during AMC period and maintenace items required during AMC period are deemed to be included in the above rate.
Taking out rusted side cover sheet and replacement with new PGI 1.0 mm thick including fabricating as per existing size 87cm X 72cm and shape complete all as per specified and directed.
Taking out rusted side cover sheet and replacement with new PGI 1.0 mm thick including fabricating as per existing size 69cm X 91cm and shape complete all as per specified and directed.
Preparation of existing painted surface of washing machine and tumbler applying putty, rubbing with Amery paper and making ready for painting complete all as per specified and directed.
Spray painting of drying tumbler and washing machine with approved colour of synthetic enamel paint over a coat of primer red oxide complete all as per specified and directed.
Material and labour for earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6 mm thick buried vertically in ground to depth not less than 2.25 metres below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to GI or steel earth lead strip 32 x 6 mm size upto 7.5 mtrs long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly including watering pipe GI 20 mm bore, light grade, including protection pipe GI medium grade 15mm bore for earthing lead, wire mesh, funnel,lugs, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1, precast RCC cover slab 50 mm thick 1:2:4 type B-1 using XPM reinforcement weighing not less 4kg/sqm in lieu of CI cover with CI frame all as shown in electrical plate No 3 of SSR part-I (2009), including testing on completion including taking down of existing earthing as exists on site complete all as specified and as directed. Note :-- (i) Any variation in length of earth lead and protection pipe of earth lead shall be adjusted through DO. (ii) On testing if the earth resistance is not obtained, earthing will be generated at NO extra cost ,till the desired earth resistance is obtained.
Deduct total amount of Credit Rs 89676.00
CHOUDHARY ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .