Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹79.0 LAccepted-AOC | L-1 | Accepted-AOC AS CWC-II DECISION HELD ON 21/09/2023 | |
| 2 | L-2₹94.3 L+₹15.3 L (19.4%)Rejected-AOC | L-2 | Rejected-AOC AS CWC-II DECISION HELD ON 21/09/2023 | |
| 3 | Rejected-Technical S 5 JALANDHAR BYE PASS ROAD PATHANKOT PATHANKOT PATHANKOT PATHANKOT PUNJAB 145001 UDYAM PB 16 0002469 | PATHANKOT | PUNJAB | 145001 | - | Rejected-Technical AS PER CWC II DECISION HELD ON 05/09/2023 |
Tender Value
₹79.3 L
EMD Value
₹1.4 L
Closing Date
23 Aug 2023, 2:45 pmClosed
GENERAL MANAGER
O.F.BHANDARA
Provision of electrification work in vertical hydraulic press SBP-369 Bldg. inside factory at O. F. Bhandara
2023_MIL_164565_1
No.EO/51/ND2321/BF
Open Tender
Electrical Works
Item Rate
60 days
O.F.Bhandara
As per Tender Documents.
8 documents required · 8 mandatory
₹0
₹1.4 L
Yes
22 Sept 2023
16 Aug 2023
25 Aug 2023
16 Aug 2023
23 Aug 2023
16 Aug 2023
Amount
Rough excavation in hard dense soil in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out.
Rough excavation in Mud in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out.
Excavating in trenches in hard dense soil for each additional 1.5m or part thereof in depth beyond the first 1.5 m and getting out for earth pits.
Back filling of excavated soil spreading, levelling, watering & well ramming in layers.
M & L fine sand filling in the trench for cushioning of cable /Substation trench filling.
Supply & fixing of of Cast Iron Frame and Cover for earth pits in FG 150 grade of material.
M& L for MS angle size 40 x 40x5 mm for framed brackets drilled and counter sunk screw including bending and welding angles as necessary , gusset plate reveting etc. not excceding 10 KG each bracket conforming to Fe290 grade E-165 foe LED luminarie.
S&F including fabrication work of Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc.
S & F for rolled mild steel in plates (plain or chequered),channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment over cable trench , of quality GDE Fe 410-W (Gde-E-250)quality-B complete all as specified , with riveted or bolted or welded attachment and as directed by the Engineer-in-Charge
Writing letters or figures by stenciling, 8 CM height (white enamel paint)(Block,Roman,Italic or Indian ) not exceeding 30 cm height.
S&Fof GI pipe medium grade 100 mm dia. under the road/ hard standing/Traverse.
S&Fof GI pipe medium grade 50 mm dia. for 32x5mm earth flat from earth pit to Bldg.
Supply & laying of UN-REINFORCED PRECAST CONCRETE CABLE COVER , CLASS LV, Type I, flat, size 250mm x 150mm x 40mm
Supply , laying , fixing & connection (by using brass cable gland and copper lugs) of XLPE insulated PVC sheathed armoured with galvanized strip steel U.G. cable with Aluminium conductor electric cables 4core X 35 Sq. mm with aluminium conductor,1100 Volt grade,.as per IS:1554(part-1) & IS:7098(part-1) etc as required Gloster/polycab/Havelles/Uniflex/Finolex/CCI make.
S & F of Flameproof & Weather proof IP66 switches, rotary type with termination box LM 6, 16A, double pole,250 V, duly certified by CIMFR, Dhanbad for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection. MAKE:SUDHIR SWITCHGEAR/PLUTO/PROMPT/SHYAAM/FCG/FLAME PROOF EQUIPMENT/CROMPTON.
Supplying, installation and testing of Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth duly certified by CIMFR for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection.MAKE:SUDHIR SWITCHGEAR/PLUTO/PROMPT/SHYAAM/FCG/FLAME PROOF EQUIPMENT/CROMPTON.
M&L for earthing complete with galvanised steel earth plate elecrode 60X60 cm X6 mm thick,buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level,connected to galavanised strip 32X6 mm as earthing lead by means of bolts,nuts,check nuts and washers of galvanised iron or steel including upto 7.5 mtr length /test point as per IS:3043/1987 and SSR-2020 Plate no.3 & indiacted testing on completion as directed by EIC.
M&L for earthing complete with copper earth plate elecrode 60X60 cm X3.15 mm thick electrode buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level,connected to Copper strip 20X3 mm as earthing lead by means of bolts,nuts,check nuts and washers of stainless steel including upto 7.5 mtr length /test point as per IS:3043/1987 and SSR-2020 Plate no.3 & indiacted testing on completion as directed by EIC.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire
Demolition built in cement concrete of any description and in any position.
Supplying , installation, testing & commissioning of LED Street Light luminaire made of die cast aluminium with street optic lenses for uniform light distribution, IP:66 protection having system lumens output not less than 6500 lumens and power consumption shall not exceed 60 watt, CCT not less than 5700, CRI not less than 70 i/c built in electronic driver and surge protector connection etc as reqired. (Make: Crompton LST-60-CDL-M or equivalent in Philips/CG/Wipro/Bajaj)
M & L for remaking of dismantled portion of concrete / road or grouting pole/stay/LP base by PCC of 1:2:4 of type B-1 using 20 mm aggregate.
Supplying and making end termination with brass heavy duty SINGLE compression gland and heavy dutyBI-METALLIC lugs for of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required per cable per end as one set. Cable size 3½ X 300 sq. mm. Bi-metallic lug test certificate to be submitted by the contractor.
Supplying and laying of DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. Conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required. In the existing trench complete as req. ID more than 109 mm nominal thickness 6mm for fitting to 100mm GI Pipe at bending portion as directed by EIC.
M&L for earrth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32X5 mm galvanised iron strip.
M&L for earrth continuity conductor or main earthing lead fixed to wall on batten or parapet or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25X5 mm galvanised iron strip.
Supply & fixing of G.I. watering pipe in earth pits medium grade 25 mm Dia with GI nuts & bolts ,2 nos of clamp ,funnel, steel wire mess etc .
Supply, installation and testing of Lighting Distribution Panel-01 No. comprising of a) Incoming: 125A, 4P, MCCB 10 KA: 1 No. b) Outgoing: 32A, 4P, MCB 10 KA: 2 No., c) Outgoing: 16A, DP, MCB 10 KA C-Curve: 10 Nos. MCCB shall have Rotary handle mechanism brought outside front panel for operation. MCB should be operated from outside without opening of front door of panel with 125A RYBN copper bus bar with 100% neutral complete in all respect including all necessary accessories with suitable gland openings in incoming and outgoing and suitable space for existing incoming cable connections with the MCCB incomer with suitable anchor fastners for grouting arrangement, angle iron framework etc as required. CRCA Sheet thickness 2mm, Both Wall mount and floor mount option. Powder coated siemens gray. Firm supply required foundation frame and instal the panel over frame. Make: ABB / L&T/ SIEMENS/ SCHNEIDER ELECTRIC / MERLIN GERIN/GE.
Supply, Installation, Testing and Commissioning of Flameproof & Weather proof 450mm sweep metal exhaust fan (1400 rpm) suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required duly certified by CIMFR Dhanbad for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection MAKE:SUDHIR SWITCHGEAR/PLUTO/PROMPT/SHYAAM/FCG/FLAME PROOF EQUIPMENT/CROMPTON.
Supply & Fixing and testing of Flameproof & Weather proof LED tube light fitting ,2 X20 Watt,4 feet, with IP66, including T-8 LED tube lamp , with suitable angle for grouting arrangement, duly certified by CIMFR, Dhanbad.MAKE:SUDHIR SWITCHGEAR/PLUTO/PROMPT/SHYAAM/FCG/FLAME PROOF EQUIPMENT/CROMPTON. LED Tube Rod shall have 2 years warranty and industrial application purpose suitable for FLP enclosure enviroment.
S & F of flameproof LED well glass/Flood light fitting, 40 watt duly certified by CIMFR Dhanbad for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size. Firm shall supply suitable bracket with saftners for position/angle adjustment of light fitting. MAKE:SUDHIR SWITCHGEAR/PLUTO/PROMPT/SHYAAM/FCG/FLAME PROOF EQUIPMENT/CROMPTON.
S & F of flameproof LED well glass/Flood light fitting, 60 watt duly certified by CIMFR Dhanbad for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size. Firm shall supply suitable bracket with saftners for position/angle adjustment of light fitting. MAKE:SUDHIR SWITCHGEAR/PLUTO/PROMPT/SHYAAM/FCG/FLAME PROOF EQUIPMENT/CROMPTON.
S & F of CIMFR certified flame proof/weather proof flexible metalic hose conduit of stainless steel with the existing fitting and metalic conduit i/c all accessories complete etc. as reqd. Length 500mm.
Supplying, installation and testing of Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 25A, 415V, 3P+earth duly certified by CIMFR for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection. MAKE:SUDHIR SWITCHGEAR/PLUTO/PROMPT/SHYAAM/FCG/FLAME PROOF EQUIPMENT/CROMPTON.
Installation and testing of existing Flameproof & Weather proof IP66 junction box, 16 Amp rating, 4Way connector, 100mm dia duly certified by CIMFR, Dhanbad. Unused/blank holes of connector box suitably sealed by metallic gland plug MAKE:SUDHIR SWITCHGEAR/PLUTO/PROMPT/SHYAAM/FCG/FLAME PROOF EQUIPMENT/CROMPTON.
S&F testing point, made of 25 mm X 5 mm thick G.I. strip, 125 mm long, with 4 nos. of SS bolts, nuts, chuck nuts and spring washers etc. complete as required
S&F testing point, made of 25 mm X 5 mm thick Copper strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required
Supplying, fabricating & fixing of 200x200x8mm G.I. base plate with suitable fastners on the existing CC blocks i/c providing & fixing of 40mm medium class G.I. Pipe of height 2.1 mtr. For fixing of air termination i/c weldding of G.I. base plate & G.I. pipe with suitable 4 Nos. of G.I. cleat i/c fixing of air termination finial, G.I strip complete etc. as reqd.
Supplying & fixing of red colour heavy duty DMC earthing G.I. strip insulator for fixing of lightning protection etc. complete fixing with hardwares of stainless steel as reqd.
Static charge dessipator fabricated from Aluminium Chequered Plate size 600x600x8mm complete with stainless steel hardwares and connected to earthing terminal
Supplying, installation, testing & commissioning of cubical type DOUBLE DOOR OUTDOOR feeder piller panel with Rain protection hood complete with suitable for 415 V, 3 phase, 4 wire, 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2.5 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade having , DMC/SMC bus bar supports, bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections. , entire panels shall have 1 no. common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud for each earth bar, solid connections from main bus bar to switch gears with required size of copper bus bars and control wiring with 2.5 sq.mm. FRLS copper conductor single core cable, cable alleys, separate removable gland plates for each cable entry and foundation for the panel i/c providing & fixing following switch gears and assessories. 1) OUTDOOR FEEDER PILLAR PANEL-1 (FP-1): Consists of following switch gears and assessories. a) Rotary Handles, spreader has to be provided for all the switchgears. b) Incomer Feeder, Qty. 1 No.: 630 A MCCB FP 36 kA breaking capacity with thermal megnatic release.- c) Outgoing Feeders, Qty. Two Nos.: 400 A FP MCCB, 36 kA breaking capacity with thermal magnetic release. d) All the three feeders should have 3-Phase Digital Multifunction Meter, Accuracy class 1.0 e) Busbar : 800 Amps capacity extendable type TPN Electrolytic Tinned copper busbars of high conductivity (Size:500 Sq.mm minimum for RYBN). There should be one runs of copper earth bar of size 25mmX5mm from left to right of the panel (extended outside upto 10cm aprox) for connecting earth strip. f) CT's as per feeder rating i.e. 630/5A and 400/5 Amp, Class 1, 15VA - total 3 Sets. g) There shuold be heavy duty CT bypass type strip connectors, MCBs for control wiring and indication circuit, RYB indication on all three feeders. (Make of MCCB/MCB/Meters: L&T, Schneider, ABB) 2) OUTDOOR FEEDER PILLAR PANEL-2 (FP-2): Emergency Switch consisting of 400 A FP Isolator, 36 kA breaking capacity with Rotary Handle, spreader etc., LED Indication Lamp RYB as complete set. (Make of MCCB/MCB/Meters: L&T, Schneider, ABB)
Supplying, installation, testing & commissioning of cubical type INDOOR LT PCC panel complete with suitable for 415 V, 3 phase, 4 wire, 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2.5 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade having 500 Amps capacity extensible type TPN Electrolytic Tinned copper busbars of high conductivity, DMC/SMC bus bar supports, bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panels shall have 2 nos. common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud for each earth bar, solid connections from main bus bar to switch gears with required size of copper bus bars and control wiring with 2.5 sq.mm. FRLS copper conductor single core cable, cable alleys, separate removable gland plates for each cable entry i/c providing & fixing following switch gears and assessories. Rotary Handles, spreader has to be provided for all the switchgears A) Incomers : a) 400 A FP MCCB, 36 kA breaking capacity with thermal magnetic release - 1 No. b) Digital Multifunction Meter, 4400 series with RS485-- 1 No. B) Outgoing: a) 250 A FP MCCB, 36 kA breaking capacity with thermal magnetic release - 3 Nos. b) 125 A FP MCCB, 36 kA breaking capacity with thermal magnetic release - 1 No. c) 63 A FP MCCB, 36 kA breaking capacity with thermal magnetic release - 2 Nos. d) 32 A FP MCCB, 36 kA breaking capacity with thermal magnetic release - 4 Nos. e) Additional 63 A FP MCCB, 36 kA breaking capacity with thermal magnetic release - 1 Nos. with Astro-mini street light timer for street light control. All outgoing of three phase streetlight feeders should be connected through single phase MCBs of suitable rating. C) Busbar, their ratings and other accessaries: 1) 500 A 4 Strip copper Busbar, 100 % Neutral 2) LED phase Indicator lamps--- RYB-- 1 set 3) LED indicator lamps (ON/OFF)-- 4 set 4) 6A SP MCB, -- 3 Nos. 5) CT's 400/5A, Class 1, 15VA - 3 Nos. 6) There should be one run of copper earth bas of size 25mmX5mm from left to right of the panel (extended outside upto 10cm aprox) for connecting earth strip. 7) All MCCBs shall be provided with thermal - magnetic release. (Make of MCCB/MCB/Meters: L&T, Schneider, ABB)
S&F 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required
Supply of XLPE insulated, PVC sheathed armoured wit galvinised strip steel heavy duty electric cable with Copper conductor 4 Core multistrand X 4 sq. mm cross-sectional area , 1100 volts grade as per IS:1554(part-1) & IS:7098(Part-1) etc. as required Gloster/polycab/Havelles/Uniflex/Finolex/CCI make.
Labour for Laying/fixing and termination of PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of in the existing trench/HDPE/RCC/ HUME/ METAL pipe/ buried under ground/ on wall surface duly clamped with 1mm thick saddle/ Aluminium/GI cleat of size 25x3mm as required including supply of Clamping/saddling material with accessories cable size Upto 35 sq. mm. x 4 core.
Supply & Fixing of LT cable route marker made out of 12.5 cm dia.CI plate duly rivated on top of 40x40x6 mm angle from (duly) Painted with Blacksynthetic/enamelled paint) 0.75 Mtr. long and PCC cube 15x15x15 cm at bottom.
S& F for Wiring for circuit/submain wiring alongwith earth wire with the of FR PVC insulated copper conductor,make : -Polycab, Finolex/V-uard/HPL/L&T,single core cable in surface/ recessed as required in heavy duty steel conduit with Hydrostatic pressure testing at 250KPa minimum with all required accessories . Size: 2x2.5 sq. mm + 1x1.5 sq. mm earth wire. (Suitable metal union and bend should be provided).
S& F for Wiring for circuit/submain wiring alongwith earth wire with the of FR PVC insulated copper conductor ,make : -Polycab, Finolex/V-guard/HPL/L&Tsingle core cable in surface/ recessed as required in steel conduit with Hydrostatic pressure testing of 250KPa with all required accessories. Size: 2x4 sq. mm + 1x2.5 sq. mm earth wire. (Suitable metal union and bend should be provided)
S& F for Wiring for circuit/submain wiring alongwith earth wire with the of FR PVC insulated copper conductor ,make : -Polycab, Finolex/V-guard/HPL/L&Tsingle core cable in surface/ recessed as required in steel conduit with Hydrostatic pressure testing of 250KPa with all required accessories. Size: 4x4 sq. mm + 2x4 sq. mm earth wire. (Suitable metal union and bend should be provided)
Providing and laying in position 1:2:4 RCC foundation (i/c steel reinforcement as per pole manufacturing company) of size 400 mm x400 mm x 1500 mm (D) i/c excavation of earth as foundation for pole recommended as per pole manufacture standard.
Supply & erection of flange mounted hot dip Galvanized Octagonal Poles of 6.0 Mtr. height made from 3mm thick HT sheet, having bottom dia of 130mm & top dia of 70mm complete with window with flash cover at a height of 0.5 Mtr. from the base for cable termination block etc. and galvanized base plate of size 200mm x 200mm x12mm thick on existing cement concrete pedestal as required as per specifications i/c supplying and fixing of the following in the window box provided for cable termination. a) Supplying and fixing 6mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. G.I. strips 4mm thick of suitable length & width, having suitable size tapped holes as required. b) Supplying and fixing of 63 Amp terminal blocks suitable for 25 Sq.mm conductor complete with DIN channel of suitable length on the existing laminated sheet as required. c) 6 Amp. SPMCB 'C' series 10 KA - 1 No. d) Cable support clamp suitable for 2 Nos. of 4 x 16 sqmm cable. e) Supplying & fixing of galvanized arm bracket 1500 mm long double arm sword type bracket made of 40NB dia GI pipe suitable for mounting on pole having tops 70mm A/F with wall and dom for erection of LED t ype fitting as per approved by Engineer-In-Charge. f) Supplying and fixing 4 Nos. of M20 X 600 mm long 'J' type foundation bolt (EN8 grade) with nuts, washer including 2 Nos. template of 3mm thick size of 200mm x 200mm with 4 nos. 24mm dia holes suitable to match with PCD of Pole base plate as reqd. g) Supplying and laying of 3 core 2.5 sq. mm FRLS copper conductor cable for making connections from MCB to fitting as required. Make Bajaj/Crompton or equivalent to these make.
Supplying and laying of DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. Conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required. In the existing trench complete as req. 63 mm dia (OD-63 mm & ID-51 mm nominal)
M B ELECTRICALS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .