RequiredCertificate (Requested in ATC)
RequiredOEM Authorization Certificate Bid to RA enabled No Two Pan Laboratory Balance Analyticalchemicalphysical ( 1 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Standards Conformity to Indian Standard
RequiredIS:9440 latest Yes Yes BIS Marked No Yes
RequiredNo CML No if BIS marked yes otherwise put NA - * Two Pan laboratory Balance must be in Compliance to ISO GLP Yes * 1/4 Standards Pan shall be as per Standard of Weights and Measures General Rules
Required1987 Yes Yes Performance Parameters Type of Laboratory Balance Analytical Analytical Sensitivity (mg) 0.1 mg 0.1 mg Type of Calibration Internal * Maximum Capacity of weighing (grams) 220 g 220 g Response Time in seconds 3 * Shape of PAN Circular Circular Power Supply Single Phase * Warranty (Year) 1 1 Dimensional Parameters Material for Case - * Minimum Overall Diameter of Pan (mm) 90 * Material of Pointer
RequiredLevelling Arrangment
RequiredPointer Scale
RequiredRider Arrangement
RequiredPointer Adjusting Screws and Stirrups must be as per Indian Standards 9440 latest Yes * Additional Parameters Tare Facility Yes * Availability of Permanent Shock Absorption facility Yes * Overload Protection Yes * Marking of Left and Right to PAN Yes * Packing of Balance should be in convenient wooden case suitably padded and fitted with proper supports at various points Yes * Printer and PC Connectivity Yes Yes
RequiredNo if Printer and PC connectivity is Yes mode of Connectivity (USB or RS232) otherwise put NA - * 2/4 Piece counting Features Yes Yes
RequiredNo Totaling Yes Yes
RequiredNo Check Weighing Yes Yes
RequiredNo Operating temperature Range (-10 Degree to 50 Degree Celcius) Yes * Reports Model Approval certificate for each model from director Legal Metrology Yes * Model Approval certificate No and date for each model - * Availability of Type Test reports From Central/Govt NABL/ILAC Accredited lab for weighing scale as per 9440 latest Yes * Test Report No - * Test Report Date - * Name of Lab - * Complete Address of Lab - * Calibration from concerned weight and measurement controllerate to be obtained at the time of supplies Yes * Model approval certificate
RequiredType test report and calibration certificate to be furnished if asked by buyer at the time of supplies Yes * * Bold specifications are the golden parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.