Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 LAccepted-AOC 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Being 1st lowest | |
| 2 | L2₹18.8 L+₹2.3 L (13.6%)Rejected-Finance 5 DARSHANI GATE DEHRADUN PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹19.1 L+₹2.5 L (15.3%)Rejected-Finance | L3 | Rejected-Finance Being 3rd lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
3 Oct 2024, 6:00 pmClosed
GE Clement Town
GE Clement Town MES Dehradun
REPAIR/ MAINT OF HEATING APPLIANCES, SOLAR WATER HEATER INCLUDING CONNECTED ITEMS AT CLEMENT TOWN, DEHRADUN
2024_MES_672109_1
GE /CLT / of 2024-25
Open Tender
Civil Works
Item Rate
180 days
GE Clement Town
Class D Cat b (i)
7 documents required · 7 mandatory
₹500
Yes
GE Clement Town
₹60,000
Yes
30 Dec 2024
5 Sept 2024
10 Oct 2024
5 Sept 2024
3 Oct 2024
19 Sept 2024
Amount
Taking up or down steel tubing of 20mm bore pipe and connection laid in trenches or floors or fixed to walls/roofs and including cleaning for refixing or removal to store complete with all fittings & valves etc complete all as specified and directed.
All as per description of ser item No-01 above but 25mm bore of pipe.
All as per description of ser item No-01 above but 40 or 50mm bore of pipe.
Dismantling /taking down old unserviceable mettalic plug and socket with unserviceable MCB.
Supply and lay 20mm bore pipe for Hot water 'medium grade', ISI marked, galvanized, with all fittings like socket, union, elbow, bend, tees etc and threading, cutting etc duly insulated with glass wool and aluminium cladding, jointed and laid in trenches or floors or fixed to walls/roofs etc, complete all as specified and as directed by Engr-in-Charge.
All as per description of ser item No-05 above but 25mm bore of pipe.
Supply and lay GI water tubing 20mm bore 'medium grade', galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches or floors or fixed to walls/roofs etc, complete all as specified and as directed.
All as per description of ser item No- 07 above but 25mm bore of pipe.
Supply and lay GI water tubing 40mm bore 'medium grade', galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed.
All as per description of ser item No- 09 above but 50mm bore of pipe.
Supply and replacement of Gun metal globe or gate valve with iron wheel head, screwed both ends conforming to IS 778 of 84 for iron pipe and fixed of bore of 20mm complete all as specified and directed.
All as per description of ser item No- 11 above but 25mm bore.
Supply and replacement of non-return valve of size 20mm bore, ISI Marked, complete with necessary arrangements for fixing complete all as specified and directed by Engr-in-Charge.
All as per description of ser item No- 13 above but 25mm bore.
Supply and replacement of brass tank connector of existing size, complete all as specified and directed by Engr-in-Charge.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable flat or circular of 6 sqmm size solid conductor complete all as specified and directed.
Supply and replacement of sub main wiring alongwith earth wire FR PVC insulated copper conductor single core 2x6 Sqmm and one 4 Sqmm earth wire drawn through PVC conduit in wall / surface / recessed etc all as specified and directed.
Supply and replacement of sub main wiring alongwith earth wire FR PVC insulated copper conductor single core 2x10 Sqmm and one 6 Sqmm earth wire drawn through PVC conduit in wall/surface/ recessed etc all as specified and directed.
Supply and replacement of sub main wiring alongwith earth wire FR PVC insulated copper conductor single core 4x6 Sqmm and one 4 Sqmm earth wire drawn through PVC conduit in wall/surface/ recessed etc all as specified and directed.
Supply and replacement of single pole and neutral enclosure with a two pin and earth plug and socket 240V 20 Amps complete with one single pole MCB with suitable weather proof enclosure all as specified and directed.
Supply and replacement of framed brackets of angles or tees with web and flanged cut to shape, drilled and countersunk for screw, including bending and welding angles as necessary, gusset plates, riveting etc not exc. 10 Kg each brackets, conforming to Fe 290 Gde E-165 for fabrication of water tank staging including applying two coats of synthetic enamelled paint over a coat of red oxide primer all as directed.
Disconnecting existing PVC tanks setting aside (or lowering if required) for repairs /cleaning etc and cleaning & removing all scale and dirt etc from tanks and from mouths of circulation pipes etc of existing capacity hoisting if required and reconnecting and refixing in position complete all as specified and directed.
Rotational moulded polyethylene water storage tanks capacity 500 Ltrs complete with float valve (cylindrical vertical with closed top) hoisted and fixed in position all after dismantling old unsv PVC tank complete all as specified and directed.
All as per description of ser item No- 23 above but tank capacity 750 Ltrs.
All as per description of ser item No- 23 above but tank capacity 1000 Ltrs.
All as per description of ser item No- 23 above but tank capacity 2000 Ltrs.
Supply and replacement of new Float valve high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe suitable for 20mm bore all as specified.
All as per description of ser item No- 27 above but 25mm bore.
Servicing of solar water heater system of 1000 Ltr per day (LPD) capacity complete cleaning and flushing out solar panel, arresting leakage in the system, replacing hot water hose pipe & PUF insulation of pipe, painting the solar panel frame and hot water storage tank frame with two coats of synthetic enamal paint and writing MES Nos etc of approved paint all as directed.
All as per description of ser item No- 29 above but 500 LPD.
All as per description of ser item No- 29 above but 200 LPD.
All as per description of ser item No- 29 above but 100 LPD.
Taking down hot water storage tank and transporting to work shop for repair and taking back after repair, cutting the copper tubing, removing the scale from the tubes by drilling/using wire mesh etc and brazing, arresting leakages etc refixing in the same position and testing etc., of capacity 1000 LDP, complete all as specified and directed.
All as per description of ser item No- 33 above but 500 LPD.
All as per description of ser item No- 33 above but 200 LPD.
All as per description of ser item No- 33 above but 100 LPD.
Supply and replacement of the following items suitable for 100/200/500/1000 LPD capacity solar water heater.
Heating element coil of 2 KW capacity suitable for the existing make of solar water heater, 230V, 50 Hz AC, complete all as specified and directed.
Heating element coil of 3 KW capacity suitable for the existing make of solar water heater, 230V, 50 Hz AC complete all as specified and directed.
Heating element coil of 5 KW capacity suitable for the existing make of solar water heater, 230V, 50 Hz AC complete all as specified and directed.
Thermostate with adjustable temperature suitable upto 90 degree centigrade.
Supply and replacement of 15mm dia Bib taps, chromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for brass ferrule complete all as specified and directed.
Storage tank suitable for existing capacity 1000 LPD, outer body made out of high engineering plastic and inner container made out of SS 304L Plasma TIG welded and insulated with PUF insulation complete with heating element with thermostate including hoisting to the inlet and outlet connections from solar panel complete all as directed.
Storage tank suitable for existing capacity 500 LPD, outer body made out of high engineering plastic and inner container made out of SS 304L Plasma TIG welded and insulated with PUF insulation complete with heating element with thermostate including hoisting to the inlet and outlet connections from solar panel complete all as directed.
Storage tank suitable for existing capacity upto 200 LPD, outer body made out of high engineering plastic and inner container made out of SS 304L Plasma TIG welded and insulated with PUF insulation complete with heating element with thermostate including hoisting to the inlet and outlet connections from solar panel complete all as directed.
Storage tank suitable for existing capacity upto 100 LPD, outer body made out of high engineering plastic and inner container made out of SS 304L Plasma TIG welded and insulated with PUF insulation complete with heating element with thermostate including hoisting to the inlet and outlet connections from solar panel complete all as directed.
Solar flat plate collector with 4-6mm thick glass, frame made of aluminium section complete panel of approx size 1.0m x 2.0m, maximum working pressure 245 kPa (2.45 bar) including necessary water connections complete all as specified and directed.
Solar flat plate collector with 6-8mm thick glass, frame made of aluminium section complete panel of approx size 1.5m x 2.25m, maximum working pressure 295 kPa (2.95 bar) including necessary water connections complete all as specified and directed.
Rod ETC type for solar water heater including necessary connections complete all as specified and directed.
Supply and fix in replacement sheet metal enclosure distribution board for fixing MCBs with double door, TPN 4 way, 415 volts with suitable bus bar including necessary connections,making good the disturbed surface etc complete all as specified and directed.
Supply and fix sheet metal enclosure distribution board for fixing MCBs with double door, SPN 12 way, 415 volts vertical type with locking arrangement grouting the DB and making good the broken surfaces with extra cement without any additional cost complete all as specified and directed.
Supply & Fix MCB TPN 63Amp, 10 KA repturing capacity, 230 V, 50 Hz AC, complete all as specified and directed.
Supply & Fix MCB SPN 32Amp, 10 KA repturing capacity, 230 V, 50 Hz AC, complete all as specified and directed.
Supply and replacement of tripple pole and neutral enclosure with a three pin and earth plug and socket 240V 32 Amps complete with one TPN MCB with suitable weather proof enclosure all as specified and directed.
M&L PCC (1:3:6) type C2 using 20mm aggregate as in foundation / footing of framed structure form work all as specified and as directed.
M& L for taking down geyser of capacity 25 Ltr of any type/make from existing position/location and refixing after serviceing and following repairs:- (a) Descaling and cleaning of geyser inner shell after removing of geyser assembly and pvc connection. (b) Rectifying loose electric connection (c) Rectifying air lock problem in geyser (d) Rectifying loose PVC/GI pipe connections, complete all as directed.
M& L for taking down geyser of capacity 35 Ltr of any type/make from existing position/location and refixing after serviceing and following repairs:- (a) Descaling and cleaning of geyser inner shell after removing of geyser assembly and pvc connection. (b) Rectifying loose electric connection (c) Rectifying air lock problem in geyser (d) Rectifying loose PVC/GI pipe connections, complete all as directed.
M& L for taking down geyser of capacity 50 Ltr of any type/make from existing position/location and refixing after serviceing and following repairs:- (a) Descaling and cleaning of geyser inner shell after removing of geyser assembly and pvc connection. (b) Rectifying loose electric connection (c) Rectifying air lock problem in geyser (d) Rectifying loose PVC/GI pipe connections, complete all as directed. Note :- For Item No 44 to 46 if any defective parts replacement shall be measured & paid for separately under respective item of Sch 'A'.
S&F fusible plug pressure type as approved by Engineer in Charge.
S&F stainless steel inner assembly for Geyser with 06/08/09 holes including mm thick gasket for inner assembly of geyser with 06/08/09 holes nuts, bolts, studs, washers etc complete all as specified and directed.
S & F in repair indicatiing lamp for Geyser complete all as specified and directed.
M&L metal clad pin top 15 Amp capacity complete all as specified and directed.
M&L PVC insulated flexible copper wire 3 core of size 2.5 sqmm complete all as specified and directed.
S &F in repair 15 mm dia non return valve for Geyser complete all as specified and directed.
S & F in repair inner shell (tank) of stainless steel for Geysers of 25 Ltrs capacity complete all as specified and directed.
All as per srl No 53 above but for Geysers of 35 Ltr Capacity.
All as per srl No 53 above but for Geysers of 50 Ltr Capacity.
S & F 125 mm long mild steel fastner for fixing of geyser complete all as specified and directed.
S & F in repair protected socket for ac box of cap 20 Amps complete all as specified and directed.
Repair to existing inner tank of Geyser of any capacity by means of soldering, rubbing, brazing etc complete all as specified and directed.
S & F in repair PVC connection 15 mm dia, 450 mm long for Geysers of any capacity complete all as specified and directed.
S & F in repair PVC connection 15 mm dia, 600 mm long for Geysers of any capacity complete all as specified and directed.
S & F in repair heavy stainless steel straight chrome finish thread faucet hose anti explosion design connection pipe of size 15 mm dia, 450 mm long for geyser complete all as specified and directed.
S & F in repair heavy stainless steel straight chrome finish thread faucet hose anti explosion design connection pipe of size 15 mm dia, 600 mm long for geyser complete all as specified and directed.
Supply and fix in repair thermostat switch ISI marked (adjustable type) for Geysers of any capacity complete all as specified and directed.
S&F in repair of Heating Element 1.5 KW capacity, cup type, triangular/ round/ thread type for Geysers complete all as specified and directed.
S&F in repair of Heating Element 2 KW capacity, cup type, triangular/ round/ thread type for Geysers complete all as specified and directed.
M &L for replacement of glass wool of superior quality as per sample for Geysers of any capacity including opening & re-fixing of top and bottom cover plates etc complete all as specified and directed.
Supply and fixing in repair socket out let multipurpose suitable for 5 pin 5/15 amp flush type all as specified and directed.
Supply and fixing in repair switch piano flush type 15 amps, 230V AC single pole one way all as specified and directed.
S & F in repair MCB single pole 6 to 32 Amp , 240 volts, 10 KA breaking capacity & connection complete all as specified and directed.
S & F in repair PVC insulated flexible cable three core Copper conductor of size 1.5 Sqmm, ISI marked, covered with round insulation complete are as specified and direced.
M&L hanging clamp (stand) for Geysers of any size & capacity complete all as specified and directed.
M&L for replacement of Sheet metal enclosure (AC Box) including MCB SP 20 Amps 01- Nos complete all as specified & directed.
S & F 3 Pin Top Plug of 15 Amp capacity, 240 V complete all as specified and directed.
NOTES :- 1. For the items for which specifications not mentioned any where in the tender, the BIS specifications shall be followed.
Tarachand gurudutt (BID ID -3112244)
TRINITY CONSTRUCTION (BID ID -3116425)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .