Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹72.4 LAccepted-AOC MAIN BAZAR GHUMARWIN DISTT BILASPUR HP 174021 | BILASPUR | HIMACHAL PRADESH | 174021 | L1 | Accepted-AOC Award to lowest bidder | |
| 2 | L2₹75.5 L+₹3.1 L (4.28%)Rejected-Finance | L2 | Rejected-Finance Second lowest bidder | |
| 3 | L3₹85.3 L+₹12.9 L (17.8%)Rejected-Finance SHOP NO 5 BACHAT BHAWAN UNA TEHSIL UNA HP 174303 | UNA | UNA | HP | 174303 | L3 | Rejected-Finance Third lowest bidder | |
| 4 | L4₹91.0 L+₹18.6 L (25.7%)Rejected-Finance | L4 | Rejected-Finance Fourth lowest bidder | |
| 5 | Rejected-Technical | - | Rejected-Technical The successfully completed similar type of one work not less than 40 percent of estimated cost has not submitted as per tender condition |
Tender Value
₹91.6 L
EMD Value
₹1.2 L
Closing Date
27 Oct 2020, 5:00 pmClosed
Executive Engineer
HPSIDC Ltd. Shimla
Providing Electrical Installation thereof.
2020_SIDC_41354_1
Job No. 3
Open Tender
Electrical Works
Item Rate
120 days
Jandour (Kangra)
Please refer Tender documents.
13 documents required · 13 mandatory
₹5,900
EE HPSIDC Ltd. Shimla
₹1.2 L
28 Jul 2021
7 Oct 2020
28 Oct 2020
7 Oct 2020
27 Oct 2020
7 Oct 2020
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box, fan box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.Group C.as per direction of the Engineer-in-charge.
Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with 2-way, 5/6 amps. modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.Group C.as per direction of the Engineer-in-charge.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1/2 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.(i) 2x1.5 Sq. mm.as per direction of the Engineer-in-charge.
(ii)2x2.5 Sq. mm.
(iii)2x4.0 Sq. mm.
(iv)2x6 Sq. mm.
(v) 2x10 Sq. mm.
(vi) 4x4Sq. mm.+2x4 Sq. mm.
(vii)4x6Sq. mm.+2x6 Sq. mm.
(viii)4x10 Sq. mm.+2x10 Sq. mm.
(ix)4x16 Sq. mm.+2x16 Sq. mm.
Supplying and drawing following pair of Fire Retardant, PVC insulated 0.5 sq.mm. (FR-Flexible) copper conductor, flat, unarmoured, telephone cable in existing surface / recessed, steel / PVC conduit as required. 2 Pair/4pair.as per direction of the Engineer-in-charge.
Supplying and drawing LAN cable CAT 5E, solid copper conductor protected with PVC sheath in the existing surface / recessed, steel / PVC conduit as required.as per direction of the Engineer-in-charge.
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of the Engineer-in-charge.:-(i) 20 mm. dia
(ii) 25 mm. dia
(iii) 50 mm. dia
Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required. as per direction of the Engineer-in-charge. (i) S.P. 5/ 6 Amps one way Modular switch.
(ii) 5 pin, 5/ 6 Amps Modular socket outlet.
(iii) Telephone socket outlet, Modular.
(iv)S.P. 15/ 16 Amps one way Modular switch.
(v) 6 pin,15/16 Amps Modular socket outlet.
(vi)TV. Socket outlet, modular.
Supplying and fixing stepped type Modular fan regulator on the existing modular box including making connections etc. as required.as per direction of the Engineer-in-charge.
Supplying & fixing of G.I. modular boxes of following sizes along with modular base and cover plate for modular switches in recess as required. as per direction of the Engineer-in-charge.:-(i) 2 modules (78mmx78mmx50mm)
(ii) 6 modules(205mmx78mmx50mm)
(iii) 12 modules (205mmx135mmx60mm)
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required.
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required and as per direction of the Engineer-in-charge.
Supplying and fixing bakelite batten/angle holder including connections etc. as required and as per direction of the Engineer-in-charge.:-
(ii) 450 mm deep (nominal)
(iii) 600 mm deep (nominal)
(iv) 900 mm deep (nominal)
Supplying and fixing copper strip bus-bars suitable for 63 Amp. 415 volts capacity 4 No. each of cross-sectional area (16mmx3.17mm),in the existing enclosure with all accessories including connections etc. as required:-
Supplying and fixing copper strip bus-bars suitable for 100 Amp. 415 volts capacity 4 No. each of cross-sectional area (25.4mmx3.17mm),in the existing enclosure with all accessories including connections etc. as required and as per direction of the Engineer-in-charge.
Supplying and fixing copper strip bus-bars suitable for 300 Amp. 415 volts capacity 4 No. each of cross-sectional area (31.75mmx6.35mm),in the existing enclosure with all accessories including connections etc. as required and as per direction of the Engineer-in-charge.
Supplying and fixing copper strip bus-bars suitable for 800 Amp. 415 volts capacity 4 No. each of cross-sectional area (50.80mmx9.50mm),in the existing enclosure with all accessories including connections etc. as required and as per direction of the Engineer-in-charge.
Providing and fixing following rating, four pole, 415 volts, On-Load change over switch unit, panel mounting, front handle operation, including drilling holes in the cubical, making connections, etc. as required and as per direction of the Engineer-in-charge..200 Amps.
Providing and fixing following rating and breaking capacity MCCB in the existing cubical panel board including drilling holes in the cubicle panel, making connections, etc. as required and as per direction of the Engineer-in-charge..(i) 100 Amp. -10 KA
(ii) 200 Amp. -16 KA
Providing and fixing following rating, three pole, manually operated, fixed type, air circuit breaker, magneto thermal release;DN1, open execution, in the cubicle panel, making connections, etc. as required and as per direction of the Engineer-in-charge..(i) 600/800Amp. -50 KA; C-Power
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required and as per direction of the Engineer-in-charge.:-(i) Single pole. Cat-A.
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required and as per direction of the Engineer-in-charge.:-(a) Double pole. Cat-A.
Supplying and fixing following rating, four pole, 415 volts, Isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required and as per direction of the Engineer-in-charge.. (a) 63 Amps. Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required and as per direction of the Engineer-in-charge.. (a) 40 Amps. Cat-A.
(b) 63 Amps. Cat-A.
Supplying and fixing following rating, four pole (three phase & neutral) 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 Amps. Cat-A.
Supplying and fixing 20 Amps, 240 volts, SPN industrial socket outlet, 2-pole & earth, metal enclosed plug top, sheet steel enclosure, suitable to accommodate a 20 Amp in/c costof SPN-MCB/DP, on surface or in recess, with chained metal cover for the socket outlet, complete with connections, testing and commissioning etc. as required and as per direction of the Engineer-in-charge..
Supplying and fixing 30 Amps, 415 volts, TPN industrial socket outlet, 4-pole & earth, metal enclosed plug top, sheet steel enclosure, suitable to accommodate a 30 Amp in/ccostof TPN-MCB, on surface or in recess, with chained metal cover for the socket outlet, complete with connections, testing and commissioning etc. as required and as per direction of the Engineer-in-charge..
Supplying and fixing G.I. tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for horizontal run)and as per direction of the Engineer-in-charge.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required and as per direction of the Engineer-in-charge.:-(i) Double door-8 way
(ii) Double door-12 way
(iii)Double door-16 way
Supplying and fixing of following way triple pole and neutral, sheet steel MCB distribution board, 415 volts, on surface / recess, with provision to mount 8 module incomer, 2 module sub-incomer and SP MCBs as outgoing, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required and as per direction of the Engineer-in-charge.:-(a) Double door-2+8 way (8+6+24),horizontal type
Earthing with G.I earth pipe 4.5 mtr. long and 40mm dia, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Extra for using salt and charcoal for pipe earth electrode complete as required and as per direction of the Engineer-in-charge..
Providing and fixing 6 SWG (4 mm dia.) G.I. wire on surface or in recess for loop earthing as required and as per direction of the Engineer-in-charge..
Earthing with G.I. earth plate 600 mmx600 mmx 6 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required and as per direction of the Engineer-in-charge..
Earthing with copper earth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required and as per direction of the Engineer-in-charge..
Supplying and laying 8 SWG Copper wire at 0.50 mtr. below ground level for earth electrode conductor, including soldering etc. as required and as per direction of the Engineer-in-charge..
Providing and fixing of lightning conductor finial, made of 25 mm dia. 300 mm long G.I. tube, having single prong at top, with 85 mm dia 6 mm thick copper base plate including holes etc. complete as required.
Supplying and fixing G.I. tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for vertical run)
Providing and fixing M.V.danger notice plate of 200 mm x 150 mm made of mild steel at least 2 mm thick, and vitreous enameled white on both sides and with inscription in signal red color on front side as required.
Providing and laying of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below the ground level including excavation sand cushioning, protective covering and refilling the trench etc. of the required size:-(i) Armoured cable 35 sq. mm (3.5 core)
(ii) Armoured cable 70 sq. mm (3.5 core)
(iii) Armoured cable 300 sq. mm (3.5 core)
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-(i) Armoured cable 35 sq. mm (3.5 core)
(ii) Armoured cable 50 sq. mm (3.5 core)
(iii) Armoured cable 70 sq. mm (3.5 core)
(iv) Armoured cable 120 sq. mm (3.5 core)
(v) Armoured cable 300 sq. mm (3.5 core)
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, providing and fixing of Non-return valve, Dead weight safety valve, 2 No C.P. connection rods 18" long, making good the damages, electrical connections, safety valve connections, testing and commissioning etc. as required:- (i) 10 Liter capacity water heater (Cat-A)
(ii) 25 Liter capacity water heater (Cat-A)
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) or up to required length with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:- Model to be got approved from engineer in charge.(i) Ceiling Fan 1200 mm sweep, Category-A
(ii)Ceiling Fan 1400 mm sweep, Category-A
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, including shutter in heavy duty fan, connections, testing and commissioning etc. as required:- (i) Exhaust Fan, Light duty, (Domestic) 300 mm sweep/vent air fan
(ii)Exhaust Fan, Heavy duty, 300 mm sweep
(iii) Exhaust Fan, Heavy duty, 380 mm sweep
Supplying and fixing of fancy wall bracket containing thread type CFL lamp holder (s) of all sizes and shapes, complete with all accessories but excluding CFL lamp including making connections, testing etc. as required. (i) Fixed type wall bracket 150 dia, single lamp.(Category-A)
(ii) Mirror light 610 mm, double lamp.(Category-A)
Supplying and fixing of bulk head fitting of all sizes and shapes, containing one No. thread type CFL lamp holder (s), complete with all accessories but excluding CFL lamp including making connections, testing etc. as required. (i) Bulk head fitting, CFL type (Category-A)
Supplying and fixing call bell / buzzer, suitable for D.C./A.C. single phase,230 volts complete as required and as per direction of the Engineer-in-charge.:-
Supplying and fixing Ding-Dong / Electronic musical bell, suitable for D.C./A.C. single phase,230 volts complete as required and as per direction of the Engineer-in-charge.:-
Installation, testing and commissioning of pre-wired, fluorescent light fitting/ compact fluorescent fitting of all types complete with all accessories and tubes etc. including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm x 1.6 mm thick steel conduit unto 30 cm length, painting and wiring the down rods and connections with 16/0.20 mm twin twisted flexible, cotton braided, copper cable and earthing etc. as required and as per direction of the Engineer-in-charge.:-
Providing & fixing LED Batten integrated LED channel aluminum heat sink body and as per direction of the Engineer-in-charge of Bajaj make having Bajaj/ Havells / Philips make as below:(i) Batten/LED integrated channel fitting 20W
Providing & fixing surface/ recess mounted 12/ 15W LED fitting/panel of Syska/Havells/Philips/ Bajaj make as required complete in all respect and as per direction of the Engineer-in-charge..(i) 9Watt
Supplying & fixing SKYLUKS LED surface mounting fitting 1'*1' LED panel/ luminaire of Bajaj/Havells/Philips/Syska 24/30WH WH and as per direction of the Engineer-in-charge.
Providing & fixing UV System Water Purifier Aquaguard 7 litre capacity complete in all respect as approved & directed by engineer in charge.
Providing & Fixing LED Lamp of following capacity as approved & directed by engineer in charge of Syska/Havells/Bajaj 7 - 9 Watt and as per direction of the Engineer-in-charge.
Providing & fixing Skyluks efficient LED panel recessed/surface 4*1ft of Bajaj /Syska Havells equivalent to Bajaj Code No. BZRSLL 36W GJI WH /NW complete in all respect fitting in ceiling as approved & directed by engineer in charge.
Providing & fixing LED panel/ fitting/ luminaire 2'x 2' 36 W LED of Bajaj/ Havells /Crompton/Syska or its equivalent make equal to BZSQL 36W LED WH as approved & directed by engineer in charge.
Providing & fixing shock treatment chart as approved & directed by engineer in charge
Providing & fixing synthetic rubber mat shock proof of 2mtr x 1 mtr as approved & directed by engineer in charge.
Supply, installation, testing & commissioning of 2 TR(cold) split type air conditioning unit with remote of following make complete as required in all respect with Base Frame , Refrigent copper piping , Hard PVC /Flexible drain pipe, PVC Round Cover 50mm dia upto required length including stabilizer & stand for AC as approved & directed by engineer in charge. Voltas/Lloyd/LG/Blue Star
Supply, installation, testing & commissioning of 2 TR(Hot & cold) split type air conditioning unit with remote of following make complete as required in all respect with Base Frame , Refrigent copper piping , Hard PVC /Flexible drain pipe, PVC Round Cover 50mm dia upto 6 mtrs. and as per direction of the Engineer-in-charge. Voltas/Lloyd/LG/Blue Star
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:- Model to be got approved from engineer in charge.(i) Ceiling Fan 1200 mm sweep Fusion Metallic Beige Brown /Pearl Ivory-Gold Havells
(ii) Ceiling Fan 1400 mm sweep Fusion Metallic Beige Brown /Pearl Ivory-Gold Havells
P/F Water cooler of stainless steel 40/80 ltrof Usha or make approved by Enginer-in -Charge
ARUN KUMAR SHARMA
KUMAR ELECTRONICS CO.
raman devwedi
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .