| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 LAdmitted-Finance VPO BHAPOO TEHSIL INDORA DISTT KANGRA H P | KANGRA | HIMACHAL PRADESH | 175013 | ₹2.7 L | L1 | Admitted-Finance |
| 2 | L2₹2.8 L+₹3,500 (1.28%)Admitted-Finance GROUND FLOOR THAKUR COMPLEX BASANTPUR | BASANTPUR | SHIMLA | HIMACHAL PRADESH | 171018 | ₹2.8 L+₹3,500 (1.28%) | L2 | Admitted-Finance |
| 3 | L3₹3.1 L+₹38,600 (14.1%)Admitted-Finance | ₹3.1 L+₹38,600 (14.1%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | Rejected-Technical Rejected |
| Sl No | Description | Qty | Unit | Rakesh Kumar L2 | Nikhil sharma govt.contractor L3 | Parvinder Kumar Govt. Contractor L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply of submersible pumping set of Kirloskar/Kilburn/Clama/Crompton/KSB make conforming to BIS; 8034-1976 latest suitable for lifting clean water (latest with uptodate ammendments) fitted with bronze impellers/suitable alloy directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS; 9283-1979 (latest with uptodate ammendments) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearings & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard,errection clamps,cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:- | 25 | P/HP | 6,000 ₹1,50,000 Lowest | 7,600 ₹1,90,000 | 6,600 ₹1,65,000 |
| 1.0101 Set of 25.00 HP | ||||||
| 1.02Location of site :-The site is located at a distance of 20 Kms from Pathankot Railway Station | ||||||
| 1.03The altitude of place in which :-Altitude of place is 350 Metres above Mean Sea Level. the Motor is intended to work. | ||||||
| 1.04Type of current :-A.C.Three phase supply with frequency 50 cycles per second. | ||||||
| 1.05Rated Voltage :- 415 Vvolts (+/-) 10% | ||||||
| 1.06Nos.of Pumps required :-1 No.Pump. | ||||||
| 1.07Capacity :- 5.25 L.P.S. | ||||||
| 1.08Total head in Metres :- 190 Metres | ||||||
| 1.09Length of Rising Main :- 1100 Metres | ||||||
Tender Value
₹4.1 L
EMD Value
₹8,250
Closing Date
9 Sept 2026, 11:00 amClosed
Executive Engineer
Jal Shakti Divn Indora
Replacement of submersible pumping machinery 25 HP 01 set under CRF
2026_HPIPH_142370_2
EE-JSV-NIT-3863-82 dt 31-08-2026
Open Tender
Civil Works
Item Rate
Indora
Please refer Tender documents.
2 documents required · 2 mandatory
₹350
₹8,250
18 Sept 2026
31 Aug 2026
9 Sept 2026
31 Aug 2026
9 Sept 2026
31 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply of submersible pumping set of Kirloskar/Kilburn/Clama/Crompton/KSB make conforming to BIS; 8034-1976 latest suitable for lifting clean water (latest with uptodate ammendments) fitted with bronze impellers/suitable alloy directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS; 9283-1979 (latest with uptodate ammendments) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearings & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard,errection clamps,cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:- | 25 | P/HP | 100 | ₹2,500 |
| 1.01 | 01 Set of 25.00 HP | - | - | - | - |
| 1.02 | Location of site :-The site is located at a distance of 20 Kms from Pathankot Railway Station | - | - | - | - |
| 1.03 | The altitude of place in which :-Altitude of place is 350 Metres above Mean Sea Level. the Motor is intended to work. | - | - | - | - |
| 1.04 | Type of current :-A.C.Three phase supply with frequency 50 cycles per second. | - | - | - | - |
| 1.05 | Rated Voltage :- 415 Vvolts (+/-) 10% | - | - | - | - |
| 1.06 | Nos.of Pumps required :-1 No.Pump. | - | - | - | - |
| 1.07 | Capacity :- 5.25 L.P.S. | - | - | - | - |
| 1.08 | Total head in Metres :- 190 Metres | - | - | - | - |
| 1.09 | Length of Rising Main :- 1100 Metres | - | - | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
BOQ_211540.xls
BOQ • 0.24 MB
forms.pdf
Tender Documents • 2.26 MB
terms.pdf
Additional Documents • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .