| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.3 LAccepted-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹40.9 L+₹2.0 L (5.04%)Rejected-Finance 3082 SECTOR 20D CHANDIGARH 160 020 | CHANDIGARH | CHANDIGARH | 160020 | L2 | Rejected-Finance Other Than Lowest Bidder |
Tender Value
₹38.5 L
EMD Value
₹77,000
Closing Date
13 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Chandigarh
GE Chandigarh N Area Pin-160003
PROVN OF CERTAIN SANCTIONED SPECIAL WORKS OF E/M NATURE AT K AREA UNDER GE CHANDIGARH
2022_MES_563312_1
GE/CHD-65/2022-23
Open Tender
Civil Works
Item Rate
270 days
Chandigarh
Class D category b(i) and a(ii) for contractor enlisted in MES
7 documents required · 7 mandatory
₹500
GE Chandigarh
₹77,000
Yes
8 Feb 2023
15 Nov 2022
15 Dec 2022
15 Nov 2022
13 Dec 2022
1 Dec 2022
16 Nov 2022 - 25 Nov 2022
Amount
Supply and laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 630 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Supply and laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 300 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Supply and laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 240 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Supply and laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 185 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Supply and laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Supply and laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Supply and laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 2 core complete all as specified and directed by Engr-in-Charge.
Earthing complete with galvanized steel earth plate electrode 600x600x6mm surrounded by mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less 2.25mtr below ground level with top edge of earth plate at a depth of not less than 1.50mtrs below ground level connected with and including 32x6mm galvanized iron strip as earthing lead by means of bolts, nuts, check nuts and washers made out of galvanized iron, 20mm dia medium grade GI pipes for watering with funnel, wire mesh and 40mm GI light grade protection pipe for GI strip and including necessary excavation, earth work, PCC 1:3:6 type C-2 concrete pit and RCC pit cover charcoal and common salt filling in alternate layers complete all as specified and directed by Engineer-in-Charge on electrical plate no-3 of SSR Par-I of 2009. Note:(i) If desirable earthing result not found re done earthing without any extra charge until get required earth resistance. (ii) The result sheet of earthing may submit to sub division level by contractor.
Earthing complete with and including galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected with and including galvanised iron or steel earth wire, 4mm dia (No. 8 SWG) by means bolts, nuts, check nuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SSR Part-I (2009) complete all as specified and directed by Engineer-in-Charge. Note : (i)The unit rate includes for protecton pipe 15mm and GI earth strip 4mm from top of earth plate upto 7.50 metre above ground level. (ii) If desirable earthing result not found re done earthing without any extra charge until get required earth resistance. (iii) The result sheet of earthing may submit to sub division level by contractor.
M & L for cable route indicator made of cast iron plate circular type 10 cm dia duly marked Blue colour marked LT cabless arrows mark up side duly welded/nut, bolt with angle iron 45/45 equal size and 45 cm long duly grouted on fround with PCC (1:3:6) as in foundation & earth work excavation etc complete all as specified an directred at site.
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts out door type, factory made free standing, floor mounting, dust and vermin proof cubical type, LT Panel fabricated from 3.15 mm thick CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), fully compartmentalized design with 4 Nos of copper bus bar with colour code of 475 Amps capacity each and supply and fixing the following(LT Panel No-1) :- Incoming (a) MCCB 315 Amps , 4 pole, ultimate breaking capacity 35 KA 415 Volts – 01 Nos Outgoing (a) MCCB 125.00 Amps , 4 pole, breaking capacity 25 KA,415 Volts – 01 Nos (b) MCCB 100 Amps 4 Pole,25 KA, 415 V-02 Nos. (c) MCB 32 Amps 2 Pole,240 V-02 Nos.(For street Light) (d) Suitable size of Timer analog type for street light complete
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts out door type, factory made free standing, floor mounting, dust and vermin proof cubical type, LT Panel fabricated from 3.15 mm thick CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), fully compartmentalized design with 4 Nos of copper bus bar with colour code of 475 Amps capacity each and supply and fixing the following(LT Panel No-2) :-Incoming (a) MCCB 315 Amps , 4 pole, ultimate breaking capacity 35 KA 415 Volts – 01 Nos Outgoing (a) MCCB 125.00 Amps , 4 pole, breaking capacity 25 KA,415 Volts – 02 Nos (b) MCCB 100 Amps 4 Pole,25 KA, 415 V-01 Nos. (c) MCCB 63 Amps 4 Pole,25 KA, 415 V-01 Nos. (d) MCB 32 Amps 2 Pole,240 V-02 Nos.(For street Light) (e)Suitable size of Timer analog type for street light complete
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts out door type, factory made free standing, floor mounting, dust and vermin proof cubical type, LT Panel fabricated from 3.15 mm thick CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), fully compartmentalized design with 4 Nos of copper bus bar with colour code of 240 Amps capacity each and supply and fixing the following :-Incoming (a) MCCB 160 Amps , 4 pole, ultimate breaking capacity 25 KA 415 Volts – 01 Nos Outgoing (a) MCCB 40 Amps , 4 pole, breaking capacity 25 KA,415 Volts – 06 Nos
S&F M S Box with Aluminum bus bar 32 Amp 1100 V complete of size 90mmX90mmX60mm of 3.15 mm thick sheet complete all specified.
S&F steel water tubing, galvanised, light grade, ISI marked, 80 mm bore with and including all fittings fixed to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge.
S&F steel water tubing, galvanised, light grade, ISI marked, 100 mm bore with and including all fittings fixed to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge.
S&F steel water tubing, galvanised, light grade, ISI marked, 40 mm bore with and including all fittings fixed to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches in soft/loose soil not exceeding 1.50 meter wide and not exceeding 1.5 meter in depth and not exceeding 10sqmm on plan and getting out complete all as specified.
Returning,filling in including spreding, levelling, watering and well ramming in layers not exceeding 25 cm thick each excavated soil in trenches after the pipes have been laid and tested completed as in soft/loose soil, complete all as specified.
Removing of surplus soil/excavated material to a distance not exceeding 50meter and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified.
Sand cushioning with clean dry sand to cables with layer of sand 8cm before laying of cable and 15cm thick after laying of cable complete all as specified. Note : For payment purpose punned thickness of 18cm shall be measured against spread thickness of 23cm as mentioned in para 19.75 of SSR part-I
Supply and laying burnt bricks sub class "B" old size for cable protection laid flat lengthsise perpenducualr to the axis of cable complete all as specified and direted by Engineer-in-Charge.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m complete all as specified and directed.
Dismantling insulators any type, any size complete all as specified and directed
Dismantling of ACSR or AAC conductors complete all as specified and directed
Dismantling earth wire or copper conductor, service feeder or distributor span complete all as specified and directed.
Dismantling stay assembly complete complete all as specified and directed.
Re-fixing of existing street light on existing pole after removal of aluminium conductor and cross arms from pole for suitable connection with Junction box to street light through PVC twin core cable including Suitable size of PVC conduit with clamps.
Supply and fix MCB DB sheet metal encolsure Triple pole and Neutral 4 way double door 415 Volts complete all as specified and directed.
Supply and fix MCB TPN/FP, 'B' series. 10 KA, 415 Volts 40 to 100 Amps capacity.
Supply and fix MCB SP, 'C' series. 10 KA, 240 Volts, 6-32 Amps capacity.
Taking down old unsv DI / GI pipe, joints, bends, elbow, tees, rubber joints upto 100 mm dia complete all as specified and directed by Engr-in-Charge.
Taking down old unsv DI / GI pipe, joints, bends, elbow, tees, rubber joints upto 100 to 200 mm dia complete all as specified and directed by Engr-in-Charge.
Supplying, laying, jointing, testing and commmisioning of DI Pipe as per IS 8329, class K-7 with inside cement mortar lining with spigot and socket ends laid in trenches including rubber gasket joint (tyton joints) complete all as specified and as directed at site for 80 mm bore complete all as specified and directed by Engr-in-Charge. Note : - Joints shall be measured and paid separetely
All as per item no. 34 above but for size 100 mm bore
All as per item no. 34 above but for size 150 mm bore
All as per item no. 34 above but for size 200 mm bore
Material and Labour for DI fittings/specials such as Tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and plugs of the Upto 150 mm bore confirming to IS: 9523 complete all as specified and directed by Engr-in-Charge.
All as per item no. 38 above but for size 200 mm bore
Material and labour for Rubber Gasket Joint (Tyton Joint) including jointing material for DI/CI pipe of 80 mm bore bore complete all as specified and directed by Engr-in-Charge.
All as per item no. 40 above but for size 100 mm bore
All as per item no. 40 above but for size 150 mm bore
All as per item no. 40 above but for size 200 mm bore
Supply, fixing, jointing & testing Cast Iron Sluice Valve of size 200 mm bore, ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body, confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top including taking out unsv sluice valve complete all as specified and as directed at site by the Engr-in-Charge. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.
All as per item no. 44 above but 150mm bore.
All as per item no. 44 above but 100mm bore.
All as per item no. 44 above but 80mm bore.
All as per item no. 44 above but 50mm bore.
Supply, fixing, jointing and testing of Cast iron Non Return valve size 100 mm bore without by pass arrangement, swing type, confirming to IS 5312, flanged ends pressure rating PN 1.0 complete including taking out unsv NRV complete all as specified and as directed at site by the Engr-in-Charge. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.
All as per item no. 49 above but for size 150 mm bore
Taking up or down GI tubing and connections of the size 25 mm bore from trenches / wall / floor including cleaning for refixing or removal complete all as specified and as directed by Engr-in-Charge.
All as per item no. 51 above but for size 40 mm bore
All as per item no. 51 above but for size 50 mm bore
All as per item no. 51 above but for size 80 mm bore
S&F cast Iron Air Valves with two air Outlets, 150 mm dia bore and fixing Up in cast iron water supply mains complete all as specified and as directed by Engr-in-Charge.
S&F cast Air Valves with two air Outlets, 100 mm dia bore and fixing Up in cast iron water supply mains complete all as specified and as directed by Engr-in-Charge.
S&F cast Iron Air Valves with two air Outlets, 50 mm dia bore and fixing Up in cast iron water supply mains complete all as specified and as directed by Engr-in-Charge.
Labour only for cutting of CI /DI/GI pipe in position for reducing to required length for insertion of new tees, branches etc of 100 to 150 mm bore complete all as specified and directed by Engr-in-Charge.
Material and labour for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation of brick pillar to support the pipe line including demolition of old PCC and removing the debris from site complete all as specified and as directed at site by the Engr-in-Charge.
Material and labour for GI tubing 'medium grade' of size 25 mm bore with all accessories including bends, elbow, socket, union, nipple etc complete all as specified and directed.
All as per item no. 60 above but for size 40 mm bore
All as per item no. 60 above but for size 50 mm bore
All as per item no. 60 above but for size 80 mm bore
Construction of brick masonary valve pits of size 900 mm x 900 mm x 900 mm (internal dimension of chamber), depth of chamber to be recokoned from the top of PCC in foundation to top of MS cover as shown in drg with and including MS sheet cover fabricated from 3 mm thick MS sheet and frame of angle iron 40 mm x 40 mm x 5 mm with fixing arrangement hinges and locking arrangement and painting two coats of synthetic enamel paint over a coat of red oxide primer after preparation of surfaces on MS cover and frame including necessary excavation and earth work in any type of soil, returning, filling in approved soil, disposal of surplus soil to a distance not exceeding 50 metre, 150 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation, brick work using bricks as mentioned in PS clause 5.1 in cement mortar 1:6, 15 mm plastering in cement mortar 1:4 both internally and externally 30cm below GL, 100 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring complete all as specified and directed by Engineer-in-Charge.
Construction of brick masonary valve pits of size 600 mm x 600 mm x 600 mm (internal dimension of chamber), depth of chamber to be recokoned from the top of PCC in foundation to top of MS cover as shown in drg with and including MS sheet cover fabricated from 3 mm thick MS sheet and frame of angle iron 40 mm x 40 mm x 5 mm with fixing arrangement hinges and locking arrangement and painting two coats of synthetic enamel paint over a coat of red oxide primer after preparation of surfaces on MS cover and frame including necessary excavation and earth work in any type of soil, returning, filling in approved soil, disposal of surplus soil to a distance not exceeding 50 metre, 150 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation, brick work using bricks as mentioned in PS clause 5.1 in cement mortar 1:6, 15 mm plastering in cement mortar 1:4 both internally and externally 30cm below GL, 100 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring complete all as specified and directed by Engineer-in-Charge.
LONGIA ENGINEERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .