Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-AOC ANICAD GRAMA PANCHAYAT NURUMAVU P O PATHANAMTHITTA 689589 | PATHANAMTHITTA | KERALA | 689589 | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.3 L+₹38,483.86 (4.88%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹8.8 L+₹86,646 (11.0%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹8.9 L+₹1.0 L (13.1%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹9.1 L+₹1.2 L (15.2%)Rejected-AOC NELLIKUZHY GRAMA PANCHAYATH | WAYANAD | KERALA | 670644 | L5 | Rejected-AOC L5 |
Tender Value
₹8.9 L
EMD Value
₹13,377
Closing Date
27 Feb 2021, 4:00 pmClosed
Assistant Executive Engineer
Assistant Executive Engineer, PWD Roads Sub-Division, Kothamangalam
In this estimate, construction of a protection wall in DR masonry for a length of 35m with an intermediate belt is proposed Onnukal vangaloor road is one of the state highway SH 44 under Pothanicadu section
2021_PWD_417770_1
PWD/2020-2021/19453/KMGM
Open Tender
Civil Works - Roads
Item Rate
60 days
Under Pothanicad section
Refer tender documents
7 documents required · 7 mandatory
₹1,970
₹13,377
Yes
25 Jun 2021
22 Feb 2021
1 Mar 2021
22 Feb 2021
27 Feb 2021
22 Feb 2021
Amount
DETAILED ESTIMATE
3.13.1.B : Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising the remaining earth locally for road work.<br> Ordinary soil - Mechanical Means - (Depth upto 3 m) <br>Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising the remaining earth locally for road work. Ordinary soil - Mechanical Means - (Depth upto 3 m)
od20472/2020_2021 : Dry Rubble masonry construction for retaining walls.
od20474/2020_2021 : Dry rubble masonry using departmental rubble for foundation and retaining wall including all charges etc complete as per drawing and specification
12.4 : Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.
12.8.1.C : Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications <br> RCC Grade M20 - Using Concrete Mixer - (Without formwork) <br>Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications RCC Grade M20 - Using Concrete Mixer - (Without formwork)
12.8.B : Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications <br> PCC Grade M20 (Without formwork) <br>Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications PCC Grade M20 (Without formwork)
12.40 : Supply, Fitting and Placing un- coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical SpecificationsSupply, Fitting and Placing un- coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications
12.8.A.1 : Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. <br> PCC Grade M15 <br>Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. PCC Grade M15
8.15 : Supplying and installation of delineator (Road way indicators) posts 80- 100cm high above ground level, pained black and white in 15 cm wide strips, fitted with min. 80 x 100 mm rectangular or 75 mm dia circular retro reflectorised panels at the top with minimum visibility of 300m with provisions to prevent edge lifting and vandalisam, and conforming to clause 806 , IRC-79 and the drawings including fixing to ground (The deleniator shall be of approved type as per specification)Supplying and installation of delineator (Road way indicators) posts 80- 100cm high above ground level, pained black and white in 15 cm wide strips, fitted with min. 80 x 100 mm rectangular or 75 mm dia circular retro reflectorised panels at the top with minimum visibility of 300m with provisions to prevent edge lifting and vandalisam, and conforming to clause 806 , IRC-79 and the drawings including fixing to ground (The deleniator shall be of approved type as per specification)
13.9.A : Back filling behind abutment, wing wall and return wall complete as per drawing and Technical Specification <br> Granular materialBack filling behind abutment, wing wall and return wall complete as per drawing and Technical Specification Granular material
Jose P.M
Jince
A R CHERIYAN
antony devassy
Bidder Name
BIJU JOSEPH
Jince
A R CHERIYAN
antony devassy
Jose P.M
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_593295.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .