| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.0 LAccepted-AOC THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | ₹6.0 L | 1 | Accepted-AOC agmt |
| Sl No | Description | Qty | Unit | DIVIN SAM D S L1 |
|---|---|---|---|---|
| 1.00 | 1.24.3
Supplying and fixing following modular switch/ socket
on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch | 2 | each | 156 ₹312 Lowest |
| 2.00 | 1.24.5
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet | 2 | each | 207 ₹414 Lowest |
| 3.00 | 1.21.1
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm | 300 | metre | 99 ₹29,700 Lowest |
| 4.00 | 1.17.2
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x
1.5 sq. mm | 30 | metre | 49 ₹1,470 Lowest |
| 5.00 | 1.17.30
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm | 10 | metre | 198 ₹1,980 Lowest |
| 6.00 | 1.10.1
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group A | 10 | point | 852 ₹8,520 Lowest |
| 7.00 | 2.12.1
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | 2 | each | 402 ₹804 Lowest |
| 8.00 | 2.14.2
Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | 2 | each | 2,490 ₹4,980 Lowest |
| 9.00 | 2.10.1
Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole | 4 | each | 237 ₹948 Lowest |
| 10.00 | 5.6
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. | 1 | set | 14,021 ₹14,021 Lowest |
Tender Value
₹6.0 L
EMD Value
₹14,941
Closing Date
15 Oct 2025, 6:00 pmClosed
ASSISTANT EXECUTIVE ENGINEER
TVM CORPORATION
PATTOM WARD POTTAKUZHI JUNCTION WAITING SHED Outdoor LED Video Wall, FM, CCTV, USB Charging Port INSTALLATION
2025_LSGD_803578_2
AEE2/TENDER/1722/ELEC/25-26
Open Tender
Electrical Works
Item Rate
90 days
TVM CORPORATION
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,320
Yes
₹14,941
Yes
19 Feb 2026
10 Oct 2025
17 Oct 2025
10 Oct 2025
15 Oct 2025
10 Oct 2025
Amount
1.24.3 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.5 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.17.2 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
1.17.30 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
1.10.1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.2 Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.1 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
90.14.1.1 Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame)
1.17.1 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x1.5 sq. mm
1.17.11 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x2.5 sq. mm
OD281533/2025-2026 Supply and Fixing of 32A Neutral Link
OD281528/2025-2026 Supply and Fixing of 32 A Fuse unit
90.16.1.2 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
OD281536/2025-2026 Supply and Fixing of DC Pin
1.53.1 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
OD281538/2025-2026 Supply and Installation of Wifi Router 1200Mbps , 2.4GHZ upto 300Mbps and 5GHz upto 87Mbps
1.17.12 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
2.3.2 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
1.17.3 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X1.5 sq.mm
2.3.4 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)16 way, Double door
OD281524/2025-2026 Supply and fixing Analogue time switch suitable for 1 output per phase and suitable for single phasesupply including necessary connections as required.
OD281527/2025-2026 Supply and Fixing of 15 Watts Cealing Light
90.10.1.5 Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface
1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.4 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.28.4 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
OD281526/2025-2026 Supply and fixing following Modular Switch / Socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required RJ 45 Socket Outlet
OD281531/2025-2026 Supply and fixing Keystone for RJ 45 CAT6 Socket
OD281523/2025-2026 Supply and Installation of 32inch LED Smart TV
OD281534/2025-2026 Supply and Fixing of HD Video Balun upto 8MP
OD281525/2025-2026 Supply and Fixing of 2TB Hard Disc for CCTV
OD281532/2025-2026 Supply Installation of 2MP bullet I.R 3.6MM CCTV Camera
OD281535/2025-2026 Supply and Installation of 4 Channel , 1080p 1U ,upto 5MP with 2years of Manufacturing Warranty Resolution DVR
OD281539/2025-2026 Supply ans=d Installation of 2 U Rack
OD281537/2025-2026 Supply and Fixing of Ahuja Cealing Speaker CSD 6303T( 6 INCH 30 Watts )
OD281529/2025-2026 Supply and Fixing of Ahuja SSB 80DFM Amplifier with Bluetooth,USB&FM
OD281530/2025-2026 Supply and Fixing of P2.5 outdoor LED video wall is a display system with a 2.5mm pixel pitch, designed for outdoor environments. Key specifications include high brightness (typically 5000 nits or higher), a high refresh rate (often 3840Hz or more), and weatherproofing (IP65 rating or similar). These displays are known for their high resolution, wide viewing angles, and ability to deliver clear visuals even in direct sunlight.
OD281548/2025-2026 Supply and Fixing of Type A+C USB Charger with 2.4 A, 220-240 V AC Rated Supply Voltage,
90.10.1.1 Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )1 module moulded plastic box on surface
1.28.1 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1347009.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .