Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance B WING 601 602 DELPHI BUILDING CENTRAL AVENUE HIRANANDANI BUSINESS PARK POWAI MUMBAI MAHARASHTRA 400076 | MUMBAI SUBURBAN | MAHARASHTRA | 400076 | Admitted-Finance |
| 2 | Admitted-Finance 53 54 56 AND 57 HADPSAR IND ESTATE PUNE MAHARASHTRA 411013 | PUNE | PUNE | MAHARASHTRA | 411013 | Admitted-Finance |
| 3 | Admitted-Finance 96 ELECTRONIC CITY COMPLEX BANGALORE KARNATAKA 560100 | BENGALURU URBAN | KARNATAKA | 560100 | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
4 Sept 2020, 12:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Mr. Puneet Khanna (Head-Supply Chain Management)
Worley India Private Limited, (formerly Jacobs Engineering India Private Limited) New Energy House, Ramakrishna Mandir Road, Kondivita, Andheri (East), Mumbai-400 059, India
FIELD INSTRUMENTS TRANSMITTERS (P, DP, F, L, T, TD) LOT 2
2020_REFHQ_121928_1
44AD0600-ER-64-0243
Limited
Instrumentation-Goods
Supply
150 days
IOCL GUJARAT IOCLGUJARAT
NOT APPLICABLE
3 documents required · 3 mandatory
Exempted
9 Nov 2020
13 Aug 2020
7 Sept 2020
13 Aug 2020
4 Sept 2020
20 Aug 2020
120 days
Flow Transmitters - Total QTY: 13 Nos. (Line item 1.1 & 1.13), Refer Doc. No. 44AD0600-00/J.04/0243 for Datasheets
Sensor Material: SS316 (as min), Range: 0-95 m3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapter
Sensor Material: GOLD PLATED MONEL, Range: 0-48000 Nm3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapter
Sensor Material: GOLD PLATED MONEL, Range: 0-48000 Nm3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapter
Sensor Material: GOLD PLATED MONEL, Range: 0-48000 Nm3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapter
Sensor Material: GOLD PLATED MONEL, Range: 0-1100 Nm3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapter
Sensor Material: GOLD PLATED MONEL, Range: 0-0.8 m3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapter
Sensor Material: SS316L (as min.), Range: 0-5 m3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapter
Sensor Material: SS316L (as min.), Range: 0-5 m3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapter
Sensor Material: SS316L (as min.), Range: 0-5 m3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapter
Sensor Material: SS316L (as min.), Range: 0-5 m3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapter
Sensor Material: SS316 (as min.), Range: 0-4 m3/h, DP @ Full Scale: 1250 mmH2O, With Kidney Flange Adapter
Sensor Material: SS316, Range: 0-20 Nm3/h, DP @ Full Scale: 1250 mmH2O, With 3-Way Manifold
Sensor Material: SS316, Range: 0-75 Nm3/h, DP @ Full Scale: 1250 mmH2O, With 3-Way Manifold
Integral Orifice Meter Run - Total QTY: 03 Nos. (Line item 2.1 & 2.3), Refer Doc. No. 44AD0600-00/J.04/0243 for Datasheets
Integral Orifice Meter Run with flanges - 1" RF/300#, 125 AARH, Plate MOC:MONEL
Integral Orifice Meter Run with flanges – 1”, RF/150#, 125 AARH, Plate MOC: SS316
Integral Orifice Meter Run with flanges – 1”, RF/150#, 125 AARH, Plate MOC: SS316.
Diffrential Level Transmitters - Total QTY: 1 No . (Line item 3.1), Refer Doc. No. 44AD0600-00/J.04/0243 for Datasheets
3”, RF/300#, 125 AARH, Sensor Material: SS316 (as min.), Range: 0-1510 mmH2O, With Seal
Electronic Indicator - Total QTY: 2 No . (Line item 4.1 & 4.2), Refer Doc. No. 44AD0600-00/J.04/0243 for Datasheets
Local Electronic Indicator, SMART with LCD Display
Local Electronic Indicator, SMART with LCD Display
Pressure Transmitters - Total QTY: 03 Nos. (from line item 5.1 to 5.3), Refer Doc. No. 44AD0600-00/J.04/0243 for Datasheets
Sensor Material : GOLD PLATED MONEL, Range: 70-110 kgf/cm²-g, With Kidney Flange Adapter
Sensor Material : GOLD PLATED MONEL, Range: 70-110 kgf/cm²-g, With Kidney Flange Adapter
Sensor Material : GOLD PLATED MONEL, Range: 70-110 kgf/cm²-g, With Kidney Flange Adapter
Temperature Transmitters - Total QTY: 01 No. (from line item 6.1), Refer Doc. No. 44AD0600-00/J.04/0243 for Datasheets
Temperature Transmitters: Range: 130-230 °C
Description of Work / Item(s)
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.01 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.02 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.03 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.04 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.05 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.06 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.07 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.08 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.09 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.10 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.11 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.12 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.13 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 2.01 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 2.02 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 2.03 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 3.01 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 4.01 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 4.02 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 5.01 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 5.02 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 5.03 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 6.01 OF BOQ1
YOKOGAWA INDIA LTD
Honeywell Automation India Ltd
YOKOGAWA INDIA LTD
Emerson Process Management
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .