| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.4 LAccepted-AOC | L1 | Accepted-AOC QUOTED AMOUNT IS LOWEST AND RESONABLE | |
| 2 | L2₹17.8 L+₹32,373.85 (1.86%)Rejected-Finance | L2 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT RESONABLE | |
| 3 | L3₹17.9 L+₹41,387.55 (2.37%)Rejected-Finance | L3 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT RESONABLE | |
| 4 | L4₹18.7 L+₹1.3 L (7.22%)Rejected-Finance DUNIYAGANJ DUNIYAGANJ PHULPUR PHULPUR ALLAHABAD UTTAR PRADESH 212402 | PRAYAGRAJ | UTTAR PRADESH | 212402 | L4 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT RESONABLE | |
| 5 | L5₹19.1 L+₹1.6 L (9.33%)Rejected-Finance | L5 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT RESONABLE |
Tender Value
₹18.9 L
EMD Value
₹37,860
Closing Date
17 Jun 2024, 6:00 pmClosed
GARRISON ENGINEER
RAMGARH CANTT
PROVN OF PARKING SHED NEAR SINGLE OFFR ACCN BLDG NO P-457 AT SRC RAMGARH CANTT
2024_MES_654015_1
8300/3235/E8
Open Tender
Civil Works
Item Rate
180 days
RAMGARH CANTT
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE RAMGARH
₹37,860
Yes
2 Sept 2024
15 May 2024
24 Jun 2024
15 May 2024
17 Jun 2024
3 Jun 2024
Amount
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and directed.
Excavation in post holes (or similar holes) in soft /loose soil not exceeding 0.5 cum, getting out, & removing surplus soil (material) to a distance not exceeding 50 mtr & making good surface complete all as specified & directed.
M&L for 100 mm thick plain cement concrete 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in sub base of flooring & mass concrete etc complete all as specified and directed.
M&L for plain cement concrete 1:4:8 ,type D-2 (using 40 mm graded crushed stone aggregate) as in foundations,filling & mass concrete for fencing posts, foundation of pole ,struts & stay assembly etc complete all as specified and directed.
M&L for plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in kerb /benching /copings /leveliing course/window cill etc. including weathering,slightly rounded or chamfered angle and throating including use & waste of necessary form work etc complete all as specified and directed
M&L for fly ash Brick work with using sub class "B' bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 etc complete all as specified & directed.
M&L for 15mm thick rendering on brick or concrete surface in cement mortar 1:6, finishing surface even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls/chajja /lintel and applying two coats of cement based paint over a coat of alkali resistant primer including necessary scaffolding complete all as specified & as directed.
Excavation in trenches in hard dense soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope /gradient for laying cables /pipes ,foundations, laying of cable,shafts, well,cesspits, manholes etc. complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers of not exceeding 25 cm thick after the cables & pipes etc. are laid, jointed & tested and foundations complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated soil exceeding 250 Mtr but not exceeding 500 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
S&F roof trusses (framed), trussed, purlins, crane gantries ,rail,rafter, heavy bracket framing (beam, tee, angle, channel or flat sections) distance pieces, cleats,fastening including fabrication and fixing conforming to Fe-410-W(Gde E-250) quality-A complete all as specified & directed. Note: Drawing & design shall be approved by GE.
M&L for prepartion of new or previously untreated steel surface of any description , not otherwise described over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed.
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified and directed.
M&L for mild steel work as in wind tie for roof including securing bolts or weld, clamp, hold fasts, wall ties, plate washer & similar articles confirming to Fe-290 Gde-E-165 complete all as specified & directed
M&L for 80 mm thick factory made machine pressed pre-cast concrete coloured interlocking paver block of approved shade, laid in design & pattern as in footpath, light traffic parking etc, made by table vibratory method using PU mould of any shape and size conforming to IS-15658-2006 of M-40 grade laid over & including 50mm thick over coarse sand/ stone dust, compacting and proper embedding/ laying by vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
S & F for 0.80 mm thick plain, galvanised, mild steel sheeting, in ridges,hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275complete all as specified and directed.
M&L for point wiring for One light point controlled by one one way switch controlled by one way switch with using with FRLSH PVC insulated PVC unsheathed electric cable conforming to IS:694, 1100V grade AC, single core having multi stranded copper conductor of size 1.5 Sq.mm nominal cross sectional area for phase & neutral and including non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall (cutting except on ceiling for fan point only, on ceiling instead of pvc conduit surface casing caping will be used) & 1.5 Sqmm green PVC insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including sunken type anodized pressed steel sheet terminal box (normal & modular type) made out of 1.6mm thick of suitable size, for mounting fittings/junction boxes including PVC board with bakelite sheet 2.8 mm thick laminated cover make sheet for housing/ fixing switches etc., including cutting holes for switches,sockets,regulators etc as per requirement including fixing with machine screw,washer etc complete all as specified and directed. Note: Proper colour coding to be adopted.
S & F switch piano flush button single pole one way 5 Amp, complete all as specified and as directed.
S & F ceiling rose three terminals PVC/ Polycarbonate, isolated body complete all as specified & as directed
S & F LED tube light fitting 1 x 20watt , 220 V, AC,to produce proper illumination with driver ,holder including LED tube light surface and wall mounted LED batten PVC housing with polycarbonate diffuserand integrated electronic driver complete with all accessories ,driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified & as directed
S & F building security lights with new generation energy saving & environment friendly long life versatile pressure die-cast aluminium IP66 roadway luminaries with high power LEDs as light source & exclusively designed polycarbonate cover along with electronic driver type street light fitting 35/36 watt capacity LED and including all necessary accessories duly pre-wired, fixing on bracket with nut, bolts & washers as required at site for fixing of street light on wall complete including all accessories duly pre-wired including provision of three core flexible copper cable of size 2.5 sqmm not less than 1.5 mtr long for connection complete all as specified & directed.
S & F double door SPN distribution boards steel sheet powder coated DBs suitable for MCBs fitted with suitable amp rated bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts suitable Amps rated busbar 4 way complete all as specified and directed.
S & F miniature circuit breaker (MCB) single pole and neutral 32 Amps (B' curve) ISI marked having current rating 10 KA,240 Volt in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S & F miniature circuit breaker (MCB) SP 5 to 32 Amps ('B' curve) having current rating 10 KA,240 Volt in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
M&L for Earthing complete for poles/DBs with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below normal ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point,GI tubing 20mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel & wire mesh,charcoal dust and common salt 15cm in layers all round the earth plate, 40 mm thick pre-cast RCC cover (1:2:4) type B-1(using 20 mm graded crushed stone aggregate )reinforced with 8mm dia TMT bar @ 75mm c/c both way with mild steel handle 20mm dia round bar , plastering 15mm thick with CM (1:6:) internally and upto 150mm below ground level externally and chamber of (size of pit 300 mm x 300 mm x 300mm internal diamentions) PCC (1:3:6) type C-1(using 20 mm graded crushed stone aggregate ) (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m & returning filling) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I including taking down old/ unserveciable existing earthing & making good disturbed surface of wall ,floors etc.complete all as directed. Notes: -(i) Earth lead & protection pipes length upto & including 7.50 metre. (ii) Earth filling shall be done by vegetable soil. (iii) Soil should be free from stone, boulders, aggregate, gravels etc.
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 16 Sqmm 2.0 core complete all as specified and directed. Note:- 1. Excavation & earthwork shall be measured & paid under respective item (2) All Necessary T & P required shall be arranged by the Contractor.
Material & labour for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed by Engineer-in-Charge. NOTE:- For measurement purpose punned thickness shall be considered as per clause 19.75 of SSR Part-I.
Supplying & Laying un-reinforced pre-cast flat concrete cable protection cover of class LV, type- 1, size 250 mm x 150mm x 40mm, factory made, complete all as specified and directed by the Engineer-in-Charge.
S & F for High density polyethylene (HDPE) pipe of 50 mm dia suitable for 6 Kgf / sq.cm working pressure with all necessary fittings for cable protection in wall ,ceilings,floors, road etc complete all as specified and directed by Engineer-in-Charge.
M/S PARAS NATH SINGH
M/s friend enterprises
SHUBHAM CONSTRUCTION COMPANY
upadhyay engineers and consultant
JP ENTERPRISES
simplex infra project
M/S Bhushan Kumar Jain
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .