Loading…
Loading…
Updated dates
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
11 Jun 2026, 6:00 pm6d left
GE (AF) No.2 Jodhpur
GE (AF) No.2 Jodhpur AF Stn Jodhpur
Replacement of electrical fittings fire alarm system flam proof light and repair/maint and servicing of split AC/Window AC desert coolers water coolers refirigerators deep freezers and allied works at Site 1A 1B at 33 SU at AFS Jodhpur
2026_MES_765682_1
8590/E8
Open Tender
Electrical and Maintenance Works
180 days
GE (AF) No.2 Jodhpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) No. 2 Jodhpur
₹90,000
Yes
15 May 2026
15 May 2026
13 Jun 2026
15 May 2026
11 Jun 2026
30 May 2026
22 May 2026 - 29 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling/taking out defective compressor unit from window type/split type AC and S&F same model new one company sealed compressor (rotary type) of 1.5 TR capacity complete with connecting fitting and fixtures making brazing work and leak test and including recharging refrigerant R -22/ R32/R410 including soldering of copper pipes, replacement of foundation rubber bushes, nuts, bolts etc complete all as specified and directed by Engr-in-charge
Make :- KIRLOSKAR/COPELAND /CARRIER/TECUMESH /VOLTAS /TOTALINE/HITACHI | 5 | Each Job | - | - |
| 2 | Dismantling/taking out defective compressor unit from window type/split type AC and S&F same model new one company sealed compressor (reciprocating type) of 1.5 capacity complete with connecting fitting and fixtures making brazing work and leak test and including recharging refrigerant R -22/ R32/R410 including soldering of copper pipes, replacement of foundation rubber bushes, nuts, bolts etc complete all as specified and directed by Engr-in-charge
Make :- KIRLOSKAR/COPELAND /CARRIER/TECUMESH /VOLTAS /TOTALINE/HITACHI | 5 | Each Job | - | - |
| 3 | Dismantling/taking out defective compressor unit from window type/split type AC and S&F same model new one company sealed compressor ( rotary type) of 2 TR capacity complete with connecting fitting and fixtures making brazing work and leak test and including recharging refrigerant R -22/ R32/R410 including soldering of copper pipes, replacement of foundation rubber bushes, nuts, bolts etc complete all as specified and directed by Engr-in-charge
Make :- KIRLOSKAR/COPELAND /CARRIER/TECUMESH /VOLTAS /TOTALINE/HITACHI | 5 | Each Job | - | - |
| 4 | M&L for servicing of window type/split type AC of 1.5/2.0 tone capacity by taking out the same from existing location, cleaning of condenser, cooling coil, and other components with cooling coil rinse solution and clean water, greasing of fan, motor, blower etc without damage any part and reinstall at the same location all as directed by the Engineer-in-Charge.Note-Spare parts shall be measured and paid sapertaly.(Note: The contractor shall at his own cost arrange water for servicing purpose.) | 180 | Each Job | - | - |
| 5 | S&F in replacement of starting relay assembly including clips and terminal cover suitable for window type/split type 1.5 TR/2 TR capacity AC complete all as specified and directed by Engr-in-charge. | 10 | Each Nos | - | - |
| 6 | S&F in replacement of starting capacitor 80/100/120 MFD including thimble for connection suitable for window type/split type 1.5 TR/2 TR AC complete all as specified and directed by Engr-in-charge Make : HAVELLS / HPL / DUCATI / EPCOS/ NEPTUNE | 15 | Each Nos | - | - |
| 7 | S&F in replacement of running capacitor 45/50 MFD including thimble for connection suitable for window type/split type 1.5 TR/2 TR AC complete all as specified and directed by Engr-in-charge. Make : HAVELLS / HPL / DUCATI / EPCOS/ NEPTUNE | 20 | Each Nos | - | - |
| 8 | Supply and fix Replacement of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and as directed. | 20 | Each | - | - |
| 9 | S&F in replacement wiring kit suitable for 4 Ton Tower AC and split type AC complete all as Specified ans as directed. | 16 | Each | - | - |
| 10 | S&F in repairs blower DC fan motor suitable for 1.5/2.0 Ton split AC of capacity Single Phase for indoor unit complete all as specifed and directed. | 15 | Each Nos | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
BOQ_857550.xls
BOQ • 0.36 MB
Tender_8590.pdf
Tender Documents • 3.31 MB
Download all tender documents and submit your bid