| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 CrAccepted-AOC | ₹9.8 Cr | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹9.9 Cr+₹16.9 L (1.73%)Rejected-AOC THOTTAPPALLY HOUSE EMILY KALPETTA P O KERALA 673121 | WAYANAD | KERALA | 673121 | ₹9.9 Cr+₹16.9 L (1.73%) | L2 | Rejected-AOC Not being L1 |
| 3 | L3₹10.3 Cr+₹47.9 L (4.90%)Rejected-AOC | ₹10.3 Cr+₹47.9 L (4.90%) | L3 | Rejected-AOC Not being L1 |
| 4 | L4₹10.4 Cr+₹59.7 L (6.11%)Rejected-AOC | ₹10.4 Cr+₹59.7 L (6.11%) | L4 | Rejected-AOC Not being L1 |
| 5 | L5₹10.4 Cr+₹60.8 L (6.21%)Rejected-AOC | ₹10.4 Cr+₹60.8 L (6.21%) | L5 | Rejected-AOC Not being L1 |
| Sl No | Description | Qty | Unit | B5BUILDING SOLUTIONS L3 | G ANILKUMAR L1 | SHAIJAL T M L2 | K P DIVAKARAN L4 | GOVARDHAN AND COMPANY L6 | M/s K V Ramachandran L5 |
|---|---|---|---|---|---|---|---|---|---|
| .50BOQ Dated Jun 2025 | |||||||||
| .75GENERAL SUMMARY NOTE: Schedule ‘A’ Part II to X are prepriced by MES under Ser No. 2 to 10. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. | |||||||||
| 2.00 | Lumpsum price worked out by the contractor for “Internal Water Supply” as listed in Schedule ‘A’ Part–II | 1 | Lumpsum | 48,000 ₹48,000 Lowest | 64,857 ₹64,857 | 70,000 ₹70,000 | 54,048 ₹54,048 | 55,000 ₹55,000 | 53,000 ₹53,000 |
| 3.00 | Lumpsum price worked out by the contractor for “Internal Electric Supply" as listed in Schedule ‘A’ Part–III | 1 | Lumpsum | 3,20,000 ₹3,20,000 | 3,42,629 ₹3,42,629 | 3,10,000 ₹3,10,000 | 2,97,939.47 ₹2,97,939.47 | 3,50,000 ₹3,50,000 | 2,95,000 ₹2,95,000 Lowest |
| 4.00 | Lumpsum price worked out by the contractor for "Site Clearance and Development" as listed in Schedule ‘A’ Part - IV . | 1 | Lumpsum | 24,00,000 ₹24,00,000 Lowest | 28,85,612 ₹28,85,612 | 27,30,000 ₹27,30,000 | 24,84,228 ₹24,84,228 | 26,50,000 ₹26,50,000 | 25,09,228 ₹25,09,228 |
| 5.00 | Lumpsum price worked out by the contractor for "Path / Hardstanding" as listed in Schedule ‘A’ Part - V . | 1 | Lumpsum | 42,00,000 ₹42,00,000 Lowest | 51,68,746 ₹51,68,746 | 61,20,000 ₹61,20,000 | 49,58,638 ₹49,58,638 | 48,50,000 ₹48,50,000 | 49,55,000 ₹49,55,000 |
| 6.00 | Lumpsum price worked out by the contractor for "Area Drainage" as listed in Schedule ‘A’ Part - VI . | 1 | Lumpsum | 28,00,000 ₹28,00,000 Lowest | 34,78,985 ₹34,78,985 | 36,80,000 ₹36,80,000 | 35,39,489 ₹35,39,489 | 34,75,000 ₹34,75,000 | 35,00,000 ₹35,00,000 |
| 7.00 | Lumpsum price worked out by the contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part – VII. | 1 | Lumpsum | 1,60,000 ₹1,60,000 Lowest | 1,93,952 ₹1,93,952 | 1,65,000 ₹1,65,000 | 1,95,456 ₹1,95,456 | 2,00,000 ₹2,00,000 | 2,00,000 ₹2,00,000 |
| 8.00 | Lumpsum price worked out by the contractor for “RCC Retaining Wall / Boundary Wall and Gate” as listed in Schedule ‘A’ Part – VIII. | 1 | Lumpsum | 1,89,20,000 ₹1,89,20,000 Lowest | 2,57,99,277 ₹2,57,99,277 | 2,65,32,000 ₹2,65,32,000 | 2,46,77,569 ₹2,46,77,569 | 2,30,00,000 ₹2,30,00,000 | 2,45,00,000 ₹2,45,00,000 |
| 9.00 | Lumpsum price worked out by the contractor for “External Water Supply” as listed in Schedule ‘A’ Part – IX | 1 | Lumpsum | 4,30,000 ₹4,30,000 Lowest | 5,57,898 ₹5,57,898 | 4,98,000 ₹4,98,000 | 5,01,707 ₹5,01,707 | 5,00,000 ₹5,00,000 | 5,00,000 ₹5,00,000 |
Tender Value
₹10.0 Cr
EMD Value
₹8.2 L
Closing Date
18 Jul 2025, 6:00 pmClosed
Chief Engineer AF Bangalore
Chief Engineer AF Bangalore No. 2 DC Area MES Road Yeshwantpur Post Bangalore 560022
PROVISION OF SWIMMING POOL AT HQ SAC (U) AT AFS TRIVANDRUM
2025_MES_704183_1
801654/E8
Open Tender
Civil Works
Lump-sum
540 days
GE (AF) Trivandrum
As per NIT
8 documents required · 8 mandatory
₹3,000
GE (AF) Trivandrum
₹8.2 L
Yes
8 Aug 2025
11 Apr 2025
25 Jul 2025
16 Jun 2025
18 Jul 2025
4 Jul 2025
16 Jun 2025 - 23 Jun 2025
Amount
BOQ Dated Jun 2025
GENERAL SUMMARY NOTE: Schedule ‘A’ Part II to X are prepriced by MES under Ser No. 2 to 10. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the contractor for “Internal Water Supply” as listed in Schedule ‘A’ Part–II
Lumpsum price worked out by the contractor for “Internal Electric Supply" as listed in Schedule ‘A’ Part–III
Lumpsum price worked out by the contractor for "Site Clearance and Development" as listed in Schedule ‘A’ Part - IV .
Lumpsum price worked out by the contractor for "Path / Hardstanding" as listed in Schedule ‘A’ Part - V .
Lumpsum price worked out by the contractor for "Area Drainage" as listed in Schedule ‘A’ Part - VI .
Lumpsum price worked out by the contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part – VII.
Lumpsum price worked out by the contractor for “RCC Retaining Wall / Boundary Wall and Gate” as listed in Schedule ‘A’ Part – VIII.
Lumpsum price worked out by the contractor for “External Water Supply” as listed in Schedule ‘A’ Part – IX
Lumpsum price worked out by the contractor for “External Electric Supply” as listed in Schedule ‘A’ Part – X
Sch 'A' Part - I : BUILDINGS OR WORKS Design and Construction of Swimming pool of size 25m x 13.5m with water depth of 1m at shallow end increasing to 4m at deep end with Diving pool of size 12m x 12m of depth 16 feet with two stage diving board at height 1m and 3m including side walks (wet & Dry Deck) and balancing tank with WPT as per specifications, all as confirming to latest IS etc complete all as specified and as shown on drawings.
Design and Construction of Spectator gallery including changing room, cascade, store room and sanitary annex in RCC framed construction with permanent specifications in RCC of grade as per structural drawings, PCC solid block masonry walls, ATT, PU based WPT, Galvalume sheet roofing, earthquake resistance as per latest IS etc complete all as specified and as shown on drawings.
Design and Construction of Pump house in RCC framed construction with permanent specifications in RCC of grade as per structural drawings, PCC solid block masonry walls, ATT, PU based WPT, earthquake resistance as per latest IS etc complete all as specified and as shown on drawings.
Design and Construction of Plant house in RCC framed construction with permanent specifications in RCC of grade as per structural drawings, PCC solid block masonry walls, ATT, PU based WPT, earthquake resistance as per latest IS etc complete all as specified and as shown on drawings.
Design and Construction of 50000 litre capacity RCC UG sump with permanent specifications in RCC of grade as per structural drawings, WPT, earthquake resistance as per latest IS etc complete all as specified and as shown on drawings.
Sch 'A' Part - XI : Fittings / Fixtures & Misc items. INTERNAL ELECTRIC SUPPLY Supply and fix LED light fitting 4 feet, 2 x 18/20 watt, surface mounted mirror optic luminaries with parabolic bright anodized AL reflector and plastic end caps suitable for connecting up three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified as directed.
Supply and fix LED light fitting 2 feet, 2 x 10/11 watt, 220Volt, surface mounted mirror optic luminaries with parabolic bright anodized AL reflector and plastic end caps suitable for connecting up three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified as directed.
Supply and fix LED light fitting 2 feet, 2 x 36 watt, 220Volt, surface mounted mirror optic luminaries with parabolic bright anodized AL reflector and plastic end caps suitable for connecting up three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified as directed.
Supply and fix 45 watts LED security light fitting with pressure die cast IP 66 protection luminous efficiency of 100lm/watt, PF>0.95, CRI>80, colour temperature 5700k suitable for primary roads with all connected accessories including bracket made out of GI tubing of 32mm outer dia 1.2m length, light grade with GI clamps, nuts and bolts etc for fixing of fitting complete in all respect all as specified and as directed.
PATH/HARDSTANDING Material and labour for heavy duty tiles/stone (Coloured/designer) tiles 10-12mm thick (square/ rectangular), area of each tiles exceeding 0.09 sqm and not exc 0.36 sqm in floors, skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, laid over 15mm thick screed bed in CM 1:6, complete all as specified and as directed.
BOUNDARY WALL Material and labour for wall cladding tiles size 350x450/300x600mm, 10 to 12mm thick as in wall, set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of the tile including 10mm thick backing coat and necessary cutting as required on site, complete all as specified and as directed. Tile shade as approved by GE.
RCC RETAINING WALL Supply and filling with granular soil back/returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of hard/dense soil complete all as specified and as directed.
Supply and fix 3mm dia wire caged block of size 300x300x300mm, with spacing of wire bars 40 mm horizontally and 40 mm vertically to fill/pack stone boulder 60 to 80 mm placed at back of each weep hole complete all as specified and as directed.
EXTERNAL WATER SUPPLY Cutting the existing 150 mm DI/CI/GI pipe, inserting tee of size 150 x 150 x 100 mm for taking branch connection including necessary threading, earth work, returning, refilling etc complete all as specified and as directed.
Supply and laying and testing of high pressure O-PVC pipes of nominal diameter 110mm, PN 16 with circumferential stiffness is greater than 7KN/m2 including all fittings and fixtures like bends, elbows, angled sockets of all angles, sliding coupler and other fittings/fixtures complete all as specified and as directed.
Material and labour for providing PCC block / pillar of appx size 0.345x0.345x0.8m (0.5M above GL) for laying of DI/GI pipe in rocky and slope areas including excavation in post holes (similar holes), returning filling and ramming earth or broken rubble mixed with earth around, in ;layers not exceeding 25cm watering and removing surplus soil to a distance not exceeding 50m and making good in hard /dense soil, PCC 1:3:6 type C2 in foundation filling and mass concrete, brick work in CM 1:6, Rendering 10mm in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement, three coat of white wash all as specified and as directed.
Supply and fix cast iron air release valves with two air outlets conforming to IS 14845 of size 100mm dia bore and fixing up in DI water supply mains of size 100mm dia complete all as specified and as directed.
Supply Install testing and commissioning of centrifugal Monoblock pump set of 3.7 KW/ 5HP, Three phase, 415 V, 50 Hz of 20 mtr head Suction 80 x Del 80mm with cast iron impeller and gland packing with necessary base plate duly grouted as recommended by OEM, pressure gauges with control valves, provn for priming etc, foundation and connection from starter to motor using suitable size of copper cable drawn through suitable size concealed rigid PVC conduit pipe all complete including necessary suction/delivery pipe GI medium grade of 80mm bore flanged with foot valve as required and as directed
Supply and fix cast iron foot valve of size 80mm dia conforming to IS-3098 complete with gaskets, bolt, nut and washers all as directed.
Material and labour brick masonry valve pit of size 90 cm x 90 cm x 90 cm (internal size) with mild steel cover 6mm thick and angle iron frame of size 90cm x90 cm x 6mm duly painted with two coats of synthetic enameled paint over a red oxide primer including locking arrangement, brick work and all inner surfaces of pit and exposed portion of out side shall be plastered in cement motor (1:4) complete all as specified and directed.
Material and labour for construction of brick masonry valve pit of size 60 cm x 60 cm x 60 cm (internal size) with mild steel cover 6mm thick and angle iron frame of size 60cm x60 cm x 6mm duly painted with two coats of synthetic enameled paint over a red oxide primer including locking arrangement, brick work and all inner surfaces of pit and exposed portion of out side shall be plastered in cement motor (1:4) complete all as specified and as directed.
Supply of potable water into the Swimming pool complete all as specified and as directed. NOTE: (a) Contractor shall supply water in hygienically neat and clean water boozer and shall be free from dust, dirt, scales and other impurities. (b) Quality of water shall be tested (routine test) and test certificate to prove the potability of water issued by a Govt approved laboratory shall be produced by the contractor. The water shall be tested for essential characteristics, Bacteriological Examination for routine test as laid down in IS : 10500-1991 and confirm to the requirements. (e) Contractor shall collect water from the sources, which shall have the prior approval of the Engineer-in-Charge.
EXTERNAL ELECTRIC SUPPLY Supply, install, test & commissioning of Indoor Vacuum circuit breaker Panel 630 Amp, HT, 11KV three phase, 630 Amps, 350 MVA, AC supply, STC-26.3KA / 3 Sec., Ambient 40 Degree, Lean gear panel type-Floor mounted encapsulated VCB in epoxy housing with IEC 62271-200/201 with bottom cable entry with copper busbar having 1 No incomer cum out going - with IP4X Alu-Zinc enclosure. The manufacturer of circuit breaker shall also be the manufacturer of the VI used in the breaker. The Circuit Breaker shall be suitable for E2, M2 & C2 (Single capacitor Bank) class duty. The offered circuit breaker should have valid type tests to support the afore-mentioned duty class. Tripping and / or release coils shall be continuous rated to ensure longer life. Integral spring charging handle to be provided in the CB with and including provision of the following :-
Supply and installation and testing and commissioning of Out door 11 KV CSS (Compact Substation) with incomer VCB of 630 A, 50Hz capacity draw out type having insulation level of 12KV/75KV impulse and, HT Cable/Bus bar, 1 No. transformer 100 KVA, 11 KV /433 CRT dry type and associated LT devices (MCCB). The compact substation should have minimum 3 mm thickness with galvanised iron enclosure suitable canopy, should be painted 7 tank process. with IP54 Class protection, even under adverse weather condition and ensure long life for inside equipments including sufficient cable entry /exit boxes should be provided for easy fixing of entry/exit cables. The CSS enclosure equipped with following accessories
Incommer VCB:- Incomer VCB with rated voltage of 12 KV and capacity of 630Amps, 50Hz insulation level of 12/28/75 KV draw out type, Motor operated, spring charging mechanism/ 230V Ac supply/ 24VDC, KV impulse VCB is having a rated short time withstand current of 63.3kA for 3 sec and rupturing capacity 350MVA, All relays such as 20c/IEF relay IDMT/master trip/ 8 window Annunciator, 3 Nos of CT for ammeter protection, 1 No of PT for voltmeter .Sufficient auxiliary relay, hooter, indication lamps for breaker open/close/Motorised spring charging mechanism with universal motor, charging time less than 5 seconds., assembly of VCB inetreptiures complete with epoxy supports insulators and self aligning isolating contacts with rating 11 KV, 21 KA, and auto trip should be provided in the VCB Panel . 80 Watt heaters and cable entry box should be provided, all bus bar aluminium of sufficient current capacity with heat shrinkable colour coded sleeve should be provided,. suitable load breaking mechanism up to 630A of rated current, along with associated earthing switch of making capacity and control voltage 24V DC for motor operation. True position mechanical indication of switch position ON, OFF, EARTH on the front face of the panel. Live cable indicating LEDs energised through capacitive voltage dividers shall be permanently available on the front face without requiring any external instrumentation, whereas the cable bushings shall be enclosed inside hinged doors cable box interlocked with respect to earthing switches. Out going of VCB Should be connected to the 100KVA Cast resin Transformer by means of suitable capacity Aluminium bus bar 100KVA TRANSFORMER:- 100 KVA 11 KV/433V, Cast resin dry type 3 Phase 50Hz, DYN -11 vector group copper wound class F insulation associated with winding trip indicator/actuated by means of resistance trip detectors embedded in LV winding, the transformer with approximate 45 impedence, tappings for off load operations on HV side in steps of 5 to 10 in steps of 2.5% with 2 runs of LV terminals connections arrangements with neutral brought at separated MCCB Out going:- MCCB , of 200 Amps , 50 ka capacitor microprocessor based 4 Pole should be provided in the LT side of the transformer, It should have provision for taking outgoing cable of suitable size The cost of electrical and Mechanical interconnection as per the condition shall be deemed to be included in the quoted rate. Rate quoted included of PCC bedding/ foundation of suitable sizes and plinth protection shall be 0.5m width which is required for installation of panel on ground as per manufacturer specifications Note: The Transformer shall be tested as per OEM recommendations and type teted certificate shall be produced by the contractor at the time of commissioning to Engineer in charge.
Returning and filling of trenches in two parts (i) using riddled soil obtained from excavated soil upto depth of 30cm (8cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil all as specified and directed. Note :- (i) Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS 1255-1983 and refilling in trenches as in cable cushioning.
Supply installing, testing and commissioning of Automatic Power Factor Correction (APFC) panel Outdoor type CPRI type tested factory made of 40 KVAR capacity ready to use design confirming to IS 5039/ IS 8623 and relevant IS/ IEC Codes rated for short circuit rating of 50 KA, front openable and lockable by keys having louvers and air vent, gasket and totally vermin proof and suitable for 415/440 V, 3 phase 50 Hz, AC and housed in elegant enclosure fabricated from minimum 3.15 mm thick CRCA sheet and min 1.6 mm thick for partitions anti corrosive coating to improve power factor to 0.99 and finally powder coated in texture Siemens grey RAL 7032 both internally and externally & as directed by Engineer-in-Charge comprising of and including following including suitable size and length of copper conductor cable PVC insulated, from main panel to APFC panel for connections as approved:-
Supply, Install, testing & commissioning factory made Out door type dust and vermin proof Feeder pillar LT panel board cubical double door hinged type compartmentalized of suitable size 415 volts, AC 50 Hz fabricated of CRCA sheet 3 mm thick machine pressed and angle iron frame 50mm x 50mmx 6mm grouted in PCC 1:2:4 type B1 (20mm grade stone aggregated) powder coated inside and outside complete including 4 poles aluminium bus bar of suitable size mounted on porcelain insulators and enclosed in chamber made out of 2mm thick CRCA sheet machine pressed and connection from incoming and outgoing electric cable with suitable size thimbles / lugs cable gland with open able shutters on both side and comprising of the following :-
(i) in comming MCCB 200 Amp, 50 KA, 4 Pole 415 Volt - 01 Nos (ii) Out going MCCB 160 Amp, 36 KA 4 Pole 415 Volt, - 01 Nos (iii) out going MCCB 63 Amp 4 pole 415 volt 25 KA - 01 Nos (iv) out going MCCB 40 Amp 4 pole 415 volt 25 KA - 01 Nos (v) out going MCCB 25 Amp 4 pole 415 volt 25 KA - 02 Nos (vi) Aluminium bus bar for 3 Ph & Neutral 400 Amp- 01 Set (vii) Muti functional meter with CT- 01 No (viii) Phase indicator neon lamps for 3 Ph -01 Set (ix) Street light control console consisting of 01 No contactor 3 phase heavy duty 32Amps rating with 415Volts digital time switch, Alfa Rex D22, astro 2 channels with power back up -01 No (x) MCB TPN 415V 32A -01 No (For street light)
Supply and installation 11 Mtr Polygonal/Octagonal GI pole, hot dip galvanised (thickness of galvanisation not less than 65 microns), thickness of sheet not less than 3mm, thickness of base plate not less than 16mm, pole bottom dia 130mm and top dia 70mm with four GI foundation bolts of suitable length and dia, GI bracket at top suitable to fix six numbers of 150watt flood light fittings with GI nut bolts and washers etc, including necessary Excavation, earth work and PCC Foundations all as specified and as directed. Make : M/s Havells/ Bajaj / Everyday
Supply and fix 9.0 Mtr GI Polygonal/Octagonal hot dipped galvanised pole including bracket maximum up to 1.5 Mtrs from pole with minimum 65 Microns Galvanizing with to diameter 70 mm and bottom 130mm, 3 mm thickness, base plate dimension not less than 220 X 220 X 12 mm with necessary foundation bolts including necessary Excavation, earth work and PCC Foundations all as specified and as directed by engineer in charge. Make : M/s Havells/ Bajaj / Everyday
Supply and fix Weather Proof PVC Junction Box made out of not less than 2 mm thick of size 250x200x100 mm (approx) complete with hinged door locking arrangement and consisting of 01 No panel mounted connector 4 pole 32 A - 01 No MCB SP 06 Amps 10 KA - 01 No including 02 Nos Cable Glands suitable for inserting cable not less than 50 sqmm with 02 No 01 mm GI plate (150x50mm) having two holes as per the size of cable glands, fixed with cable gland for earth connectivity confirming to IP 65 complete including fixing on street light pole with MS Clamps, bolts, nuts and washers complete all as specified and as directed.
Material and labour for boring (horizontal directional drilling) of holes under roads, pavements, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE Pipe of 110 mm dia (PE100, PN8, ISI 48892 HDPE pipe) suitable for 0.4Mpa working pressure to lines and levels up to a depth of 3m without damaging any existing underground utilities complete all as specified and directed.
Supply and fix LED Flood light fitting out door type Energy saving, environmental friendly, long life, die cast aluminium housing with LEDs as light source suitable for highlighting pool area lighting 150 W, impact resistance of IK07, 6000K with IP66 protection, PF >0.99, THD <10% and inbuilt surge protection including necessary fixing arrangement for fixing on pole complete all as specified and as directed.
Supply and fix LED post top lantern light fitting of energy saving sleek 70 watt LED 6000K made by pressure die-cast aluminium Opal cover, impact resistance of IK07 with IP66 protection, PF >0.99, THD <10% and inbuilt surge protection and opal diffuse with high power LED as light source complete fixing on Gate pillars including connection with all accessories complete all as specified and as directed.
Supply and fix LED post top lantern light fitting of 20 watt LED made by pressure die-cast aluminium IP-65 housing for heritage sites complete for fixing on compound walls pillars including connection with all accessories complete all as specified and as directed.
Supply and fix cable route indicator oval shaped size 200x150x6mm thick CI/MS with letter embossed as HT UG cable fixed on 25x25x6mm MS angle iron of 50cm long embedded in PCC (1:3:6) type C1 using 20mm graded stone aggregate including two coats of blue colour synthetic enamel paint over a coat of Zinc chrome primer on exposed steel surface complete all as specified and as directed.
Supply and fix Hybrid All in one Solar street light fitting 100W capacity with 110v/220v AC input along side a 120W Monocrystalline solar panel Both power sources charge a Life P04 battery bank having back up to 2 days complete guaranteeing continuous light output during cloudy days or during power cuts. The smart switch technology automatically decides between Grid Power and Solar Power to keep the battery bank charged at all times for ensuring uninterrupted lights. The unit shall have integrated MPPT charger + driver , aluminium pressure die cast housing with IP 66 protection, adjustable tilt angle 0-15 degree complete all as specified and as directed.
SWIMMING POOL FILTRATION PLANT Supply, install, test and commissioning of Pool Filtration cum recycle plant for swimming pool of size 25mX13.5mX2.35m (Average depth) and diving Pool of size 12mx 12m x 5.0m and balancing tank of 100 cum having total water capacity 1613200 Lts suitable for 6-7 hrs turnover period and flow rate of 235 cum /hr complete with following items
Supply, install, test and commissioning of Factory made Vertical cylindrical type multi grade pressure sand filter capacity minimum 95m3/hour made from MS sheet suitable with size 2000 mm dia for working pressure 2.5 Kg/cm2 duly painted (inner & outer) with red oxide primer and two coats of epoxy paint complete with suitable size of inlet, outlet valves, NRVs, control valves for operation, back wash system including valve manifold, drain out facilities complete including frontal piping of 150 MS suitable size pipes for discharge of 80 M3/hour/pressure rating 2.5 Kgf/cm2, fittings and filtration rate of 25 m3/hr, including initial filling of filter media, as required for smooth function and operation, all as per manufacturer's recommendations, for swimming pool of 8,00,000 ltr capacity and turn over period of 5-6 hours complete all as specified and directed. Note: 1. Rate quoted shall be inclusive of all type & size of UPVC/HDPE/MS frontal piping, control valves connected to the pressure filter and PCC foundation of suitable size as per manufacturers instructions 2. Piping up to pressure filter inlet & beyond outlet of pressure filter and drain pipe shall be measured and paid separately.
Supply, install, test and commissioning of Air Blower with suitable 3 Ph motor IE-2 rated, ISI marked required for filtration unit back wash process of suitable capacity but not less than 300 Cum /Hr or as recommended by OEM for swimming pool complete all as specified and as directed.
Supply, install, test and commissioning of Water circulation, Horizontal split casing end suction pump 415 V, 50 Hz, 1450 RPM suitable for pressure filter designed discharge capacity 95 m3/hour @ 25 Mtr head having pump efficiency 65-75%, and suitable for filtration plant as per Sl No 1 above for ensuring turnover period 5-6.0 hour with suitable capacity prime mover. The pump shall be of cast iron body, bronze impeller, with mechanical seals, TEFC squirrel cage IE-2 induction motor, with M.S. Fabricated base plate, mounting channel frame, accessories and fittings like pressure gauges, Air release valve, drains, coupling, coupling guard etc including PCC foundation, vibration isolation arrangement complete all as specified and as directed. (3 working and 1 stand by)
Supply, install, test and commissioning of chlorine dosing pump (venturi drive pump) 0 - 6 LPH with PP/PVC dozing tank capacity 150 Ltr - 1 Nos and piping for inlet & outlet connection complete with control valves, NRV, metering, electric cabling & copper wiring through suitable size PVC concealed conduit from Main control panel to booster pump complete all as specified and as directed.
Supply, install, test and commissioning of Acid/alkali/alum Dosing pump (venturi drive pump) 0 - 6 LPH with PP/PVC dozing tank capacity 150 Ltr with high speed stirrer and piping for inlet & outlet connection complete with control valves, NRV, electric cabling & copper wiring through PVC conduit from Main control panel to booster pump complete all as specified and as directed.
Supply, install, test and commissioning of Pool drains (drain out sump) - 500mm x 500mm x 330mm made out from SS 304 complete all as specified and as directed
Supply & install Stainless steel ladders of swimming pool of 3 steps made out from stainless steel AISI-304 of width 500mm with handrails and shall be 40mm dia of stainless steel with non-slip complete all as specified and as directed.
All as per serial item No. 55 above but Size - 5 steps
Supply, install, test and commissioning of Trolley mounted suction sweeper with self priming electric driven pump set suitable for cleaning swimming pool capacity, complete with PVC braided vacuum hose pipe of length minimum 30 Mt, 900 mm size Aluminium / bronze vacuum head, submersible flat/round copper cable of size 3 core x 10Sqmm of length 50m from Main, PVC floats, wire rope and all connected accessories complete all as specified and as directed
Supply and fix 18 inch long Nylon brush complete all as specified and as directed
Supply and fix Telescopic pole 4.8 Mtr long with extendible up 9 Mtr made of aluminium tubing complete all as specified and directed
Supply and fix Test Kit for PH & Residual chlorine complete all as specified and directed
Supply and fix Leaf rack made out of aluminium frame all as per sample complete all as specified and directed
Supply and fix Leaf skimmer made out of aluminium frame all as per sample complete all as specified and directed
Supply and install Over flow grating 300 mm x 300 mm wide shall be provided along the perimeter of pool as shown in drawing with slope 1:200, towards shall be provided as shown in drawing with slope 1:200, towards balancing tank including Gratings and support profiles made in white UV stabilized complete all as specified and as directed.
NOTES : (i) The ozonator unit shall be connected in to the main filtered water supply line after filtration plant and all connecting accessories are deemed included into the quoted rates. (ii) The control panel shall comprises voltage variation prevention devices, ammeters, auto transformers, switches, indicator lamps etc. The control panel shall be mounted in plant room and electric supply shall be extended from the existing panel board. The rate for accessories required for making electrical connection, installation are deemed to be included into quoted rates. (iii) The contractor shall submit detailed specification /design parameters, constructional and functional drawings of all components of Ioniser unit with installation system for approval of accepting officer before placing of order/execution of work . (iv) The contractor shall submit the guarantee for two years in the form of under taking in respect of performance of plant
Supply install test and commissioning of Pool floor inlets (pool jets) 63 mm dia including tail piece of 63 mm dia 20cm long wit pool floor inlets, made out of ABS plastic white colour with SS screws suitable for flow rate of 5000 ltr/hr top of floor tiles provided in bottom of swimming pool all as specified and directed.
Fabricate, Supply install test and commissioning of CPRI approved factory fabricated indoor type LT panel board suitable for 440 Volt, 3 phase & Neutral , 50Hz supply , floor mounted weather and vermin proof fabricated from MS angle of size 50x50x5 mm as base frame, with 2 mm thick CRCA sheet (Make -Tata/ sail) ( load bearing members 2 mm thick and non load bearing members such as doors partitions etc of thick ness 1.6 mm thick ), with gland plates at bottom with suitable Brass chromium plated glands, with cadmium plated high tensile nut and bolts washers, suitable barrel copper lugs for cable terminations complete, with locking arrangements complete ,sheets bend, folded, cut with CNC machine for the accuracy of dimensions +/-0.5%, duly powder coated ( after minimum 9 tank process of pre chemical treatment)with Siemens grey colour , with suitable ventilation ,including LED RYB indicators -06 nos on incoming side and ON/OFF/TRIP indications on outgoing side of Incomer, interconnections from bus bars to MCCB's with suitable size copper bus bars, all internal ckt / protection wiring with FRHR 1100 V grade wiring with MCB protection, including terminal adapters, spreader links on incoming and out going sides of ACB's/ MCCB's complete all as specified and directed and comprising of the following complete ( for Filtration plant Pump house)
(a) Bus bar Aluminum -300 A capacity- 04 Nos a , high conductivity, suitable for 415 V, 50 Hz supply including interconnection from incoming, and out going feeders with suitable mounting insulators, heat shrinkable colour sleeves. . (b) MCCB four pole 440 V,160 Amp,36 KA , range 125-160 Amps, with thermal and magnetic settings - 01 No ( Incomer) (c) MCCB three pole 440 V, 50-63 Amp,36 KA , range 40-63 Amps, with thermal and magnetic settings - 04 No (For swimming pool motors) (d) MCB three pole 440 V, 6-32 Amp,10 KA - 02 Nos (For ionisation panel + blower motor) (e) MCB SPN 6-32 Amps, 10 KA C series -04 Nos. ( for dosing pumps) (f) FASD starter suitable for pump sets -04Nos. for pump size as mentioned above with adjustable over load relay, electronic timer , single phase preventer incl all mounting arrangements. (g) FASD starter Suitable for Blower motor -01 No. of suitable capacity as mentioned above with adjustable over load relay, electronic timer , single phase preventer incl all mounting arrangements h) Motor protection relay for thermal overload earth fault locked rotor, single phasing current unbalance phase sequence reversal, under current protection for suitable pump set -04Nos j) Digital Ammeter 0-200 amps, accuracy class 1.0 including CTs (k) Digital Voltmeter(0-500V) accuracy class-1.0 - 01 No, (l) MCB SPN 20 Amps capacity, 240 V 10 KA , C series -02 No. (m) MCB SP 06 Amps capacity 240 V 10 KA , C series-03 No. (n) Multifunction meter 96x96 mm
Supply install, testing & commissioning of complete piping & valves and system all as shown in schematic & layout drgs and as required essentially for the swimming with concealed / open type piping with UPVC pipe and fitting type UPVC schedule 80 and ERW MS pipes and fittings, heavy grade, epoxy coated for suction, delivery and pool filtration system and consisting of minimum of the following:-
i) Piping - UPVC PipeSupply and fixittings - 160 mm, 200 and 250 mm dia - 10 KG pressure, with suitable size Butterfly / sluice valves as applicable - ISI marked ii) Piping MS epoxy coated heavy grade, ISI marked of dia 150 mm for suction lines of four pumps separately with suitable 150 mm dia Foot valves and butterfly valves in each suction with CI body and synthetic metal ball, strainer etc complete iii) MS delivery pipes from pump sets 150 mm dia MS epoxy coated heavy duty complete with suitable tailor made special and connected to common header and 150 mm dia NRV ISI marked -04 nos and PN 1.6 rating sluice valve IS-14846 -04 Nos complete iv) MS epoxy coated heavy duty common header 200 mm dia for delivery and suction header of suitable length including required MS specials v) MS pipe heavy duty epoxy coated of 200 mm dia with specials complete from common header to pressure filters incl necessary butter fly valves vi) Out let UPVC pipes 200 mm dia from pressure filters to swimming pool incl suitable MS butterfly valves 200 mm dia of suitable pressure rating of suitable lengths complete as required. vii) Concealed UPVC pipes 160 mm dia for outlet nozzles complete with suitable fixing arrangements inside diving pool complete viii) Concealed UPVC pipes 250 mm dia for Overflow from Swimming pool complete upto Balancing tank through lint catcher ix) Concealed UPVC pipes 160 mm dia for drain complete with suitable fixing arrangements inside swimming pool and upto common point and upto balancing tank with 150 mm dia sluice valve with SS spindle PN 1.6 rating IS-14846 with Suitable operating rod from Balancing tank top complete all as specified and directed. x) MSEP wash out pipe 160 mm dia heavy duty from pressure filters till out side rain / Storm water drain including 150 mm dia butterfly valve ISI marked with complete. xi) UPVC pipes of suitable sizes for connection of pipes to dosing pumps and blower complete all as required. xii) Set of valve manifold for each filter for operation mode in Filter/ Bypass / rinse/back wash/drain mode of 150 mm dia MS butterfly valves
Notes:- (a) All UPVC pipe & fittings shall be as per UPVC schedule 80 (b) All MS pipe & fittings shall be heavy grade & epoxy painted. (c) Any relevant item of work concerning pipe & valves not mentioned in this BOQ/schedule or in drg but essentially & technically required for the pool filtrating system of the main and diving pool is deemed to be included in the quoted rate. Nothing extra will be admissible on the count.account at any stage. (d) All civil works including excavation and earthwork to suitable depths as reqd for those items is deemed to be included in the quoted rates. (e) In case of variation in specification / sizes between sch ‘A’ and drgs, the details provided in schematic and layout drgs shall prevail. (f) Tenderer is advised to visit the site and see the schematic & layout plan of pools, balancing tank, pump house etc before quoting rates. Nothing extra will be admissible in case of certain changes are necessitated at site or layout of pools, balancing tank or pump house etc as required as per site / technical requirement during execution of work.
Supply install test and commissioning of Electrical cabling for dosing system, starters of blowers consisting of the following i) Copper wiring of suitable size with Suitable GI Protection pipe for Pump set from starter panel to Motor (6 runs of Copper wire for star delta starters)- 04Jobs ii) Copper wiring of suitable size for Air blower from starter panel to Motor with Suitable GI protection pipe iii) Copper wiring of suitable size for dosing pumps from starter panel to dosing Motor with Suitable GI protection pipe iv) Copper wiring of suitable size from main filtration plant panel to ionisation panel
Supply install testing and commissioning of under water illumination system such as under water light LED Light fittings with IP 68 certification of 14.4 w, 12 V with LED Module drive and LED drive protection including cable connection and all accessories complete all as specified and as directed.
SHAIJAL T M (BID ID -3354573)
B5BUILDING SOLUTIONS (BID ID -3349474)
K P DIVAKARAN (BID ID -3355081)
M/s K V Ramachandran (BID ID -3355291)
GOVARDHAN AND COMPANY (BID ID -3355284)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .