Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC | L1 | Accepted-AOC AWARDED DUE TO L1 | |
| 2 | L2₹17.8 L+₹1.4 L (8.28%)Rejected-Finance | L2 | Rejected-Finance REJECTED DUE TO L2 | |
| 3 | L3₹17.9 L+₹1.4 L (8.76%)Rejected-Finance | L3 | Rejected-Finance REJECTED DUE TO L3 | |
| 4 | L4₹18.9 L+₹2.4 L (14.9%)Rejected-Finance | L4 | Rejected-Finance REJECTED DUE TO L4 | |
| 5 | L5₹21.0 L+₹4.5 L (27.7%)Rejected-Finance | L5 | Rejected-Finance REJECTED DUE TO L5 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
7 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SHIKARGARH
Military Engineer Services, Garrison Engineer, Shikargarh, Near ASC Supply Depot, Ratanada Jodhpur-342011
SERVICING/REPAIRING /MAINTENANCE OF ALL TYPES OF ACS, REFRIGERATORS, DESERT COOLER, DEEP FREEZER AND WALK-IN-COOLER OF MH AND ADJOINING AREA UNDER GE SHIKARGARH
2022_MES_522534_1
8754/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE SHIKARGARH
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE SHIKARGARH
₹50,000
Yes
13 Jul 2022
9 May 2022
9 Jun 2022
9 May 2022
7 Jun 2022
24 May 2022
9 May 2022 - 23 May 2022
Amount
DESERT COOLER Taking down to desert cooler of any make & size fixed at different site / location and repair to desert cooler to stop any type of leakage, tightening / replacing to rusted screw nuts, bolts & washers with new of same size etc including floor cleaning, scraping all scales internally & externally surfaces and spray painting to desert cooler with two coats of synthetic enamel paint (hammer tone) on external surface& 2- coat of black Japan paint on internal surfaces over one coat of red oxide primer with help of spray gun machine including writing of MES/ SM No in 5cm height and re-fixing the desert cooler after necessary oiling and greasing of fan and water lifting pump at site/location complete all as specified and as directed. NOTE : Spare partst shall be measured & paid seperatly under respective item of this schedule .
M&L for rewinding of fan motor of desert cooler including cutting and removing of old burnt windings and super enamelled copper winding wire of required size including allied insulation materials varnish sleeves etc. greasing oiling re-assembling testing and refixing in the same positions complete all as specified and directed by Engr-in-Charge.
Taking down old unsv PVC flexible tubing distributor and elbows and providing new PVC flexible tubing distributor and elbows for desert coolers complete all as specified and directed by Engr-in-Charge.
Supply and fixing new fan motor in replacement of old motor AC Single Phase 230V 50Hz three speed with capacitor blades and brackets including necessary wiring complete all as specified and directed by Engr-in-Charge. Make : KHAITAN/CROMPTON/GEC
Supply and fixing of capacitor in replacement of old capacitors having 3.15/4.00 mfd suitable for fan motor of desert cooler complete all as specified and directed by Engr-in-Charge. Make : USHA/TIPCON/HAVELLS/Sharda
Supply and fixing of submersible pump of desert cooler single phase AC 230V 50Hz in replacement of old unsv Submersible pump including necessary connection and testing complete all as specified and directed by Engr-in-Charge. Make : GEC/KHAITAN/GEC
Supply and fixing of switch 5 Amp for water pump control in replacement of old switch for desert cooler complete all as specified and directed by Engr-in-Charge.Make : ANCHOR/CONA/WAWA
Supply and fixing of side shutter with handle made of Galvanised MS sheet 24 Guage in replacement of as per existing size including wire mesh complete all as specified and directed by Engr-in-Charge
Supply and fixing of front grill of desert cooler made out of GI sheet 22 Guage in replacement including air divesion control fins of existing size complete all as specified and directed by Engr-in-Charge
Supply and fixing of desert cooler body complete with bottom tank, top cover with 04 corner piece with complete frame made out of galvanised MS sheet 22 Guage in replacement for desert cooler of any capacity including dismantling and refixing of the all accessories in the unit complete all as specified and directed by Engr-in-Charge
Supply and fixing in replacement PVC fan blade of blower motor of Desert cooler suitable for any make and capacity complete all specified and directed.
Supply and fixing of new wooden wool pad of size(45X60) minimum in replacement of old pad for desert cooler of best quality as approved by Engr-in-Charge. complete all as specified and directed by Engr-in-Charge
Preparation of old painted surfaces and applying one coat spray painting of synthetic enamel paint (colour as approved) outside and two coat of black bituminous paint inside of desert cooler of any make after removal of all dust and all foreign matter with the help of sand paper and rubbing with cleaning compound complete all as specified and directed.
REFRIGERATOR/DEEP FREEZER Supply and fixing of freezer assembly with evaporating coil for refrigerator of capacity upto 190 ltrs including shouldring to copper pipe and Charging of refrigerant gas, complete all as specified and directed by Engineer-in-C harge
Supply and fixing in replacement freezer assembly with evaporating coil for Refrigerator of capacity 350/280/310/ ltrs including shouldring to copper pipe and Charging of refrigerant gas, complete all as specified and directed by Engineer-in-C harge
Disconnection old defective burnt sealed compressor unit of refrigerator/Deep freezer 280/320/310 ltrs capacity of any make and supply and fixing new sealed compressor unit including soldering of copper pipe, foundation rubber bushes, nut bolts, cleaning of refrigerant system and charging of of refrigerant gas and testing , complete all as specified and directed by Engineer-in-C harge .Make : KIRLOSKAR/KELVINATOR/GODREJ/LG
Disconnection old defective burnt sealed compressor unit of refrigerator upto 190 ltrs capacity of any make and supply and fixing new sealed compressor unit including soldering of copper pipe, foundation rubber bushes, nut bolts, cleaning of refrigerant system and charging of of refrigerant gas and testing , complete all as specified and directed by Engineer-in-Charge. Make : KIRLOSKAR/KELVINATOR/GODREJ/LG
Supply and fixing of starting relay assembly suitable for refrigerator/Deep freezer 160/290/310/320 ltrs capacity. In replacement of old relay assembly complete all as specified and directed by Engineer-in-C harge .Make : RANUTROL/HONEY WELL/HI TECH/INDFOS
Supply and fixing of over load protection suitable for refrigerator/Deep freezer 160/290/310/320 ltrs capacity. In replacement of old unsv over load protection complete all as specified and directed by EIC Make : RANUTROL/HONEY WELL/HI TECH/INDFOS
Supply and fixing of thermostat switch suitable for refrigerator of any make and capacity as per existing including taking down unserviceable complete all as specified and directed by Engineer-in-C harge .Make : RANUTROL/HONEY WELL/HI TECH/INDFOS
Supply and fix in replacement complete defrosting assembly for any size and make refrigrator including taking down unserviceable as per directed.
Supply and fix in replacement flexible elastic strip seal/gasket for refrigerator door suitable for any size and make including taking down unserviceable as per directed.
Cleaning of gas system with CTC vaccum pump and charging the refrigerant R-134a as per existing with antimoist substance and filter along with rectification of leakage in the system of 165/190/210 ltrs capacity refrigerator, complete all as specified and directed by Engr-in-Charge.
Ditto as per item No 24 but 280/310 Ltrs
WATER COOLER Supply and fixing of push cock Brass chromium plated 15 mm bore, including taking down of old push cock, complete all as specified and directed by Engr-in-Charge.
Supply and fixing of 15 mm bore PTMT float valve assembly with PVC float for water cooler including taking down of old Valve, complete all as specified and directed by Engr-in-Charge
S&F combination of any type of relay assembly complete suitable for water cooler 40/80 litrs capacity in replacement of old relay unit, complete all as specified and directed by Engr-in-Charge . Make : INDFOS/ KIRLOSKAR/HI TECH.
Supply an fixing of overload protector in replacement of old protector including clip suitable for water cooler complete all as specified and directed by Engr-in-Charge. Make : SHRIRAM/KIRLOSKAR/HI TECH.
Supply and fixing of starting capacitor 50 +/- 5% mfd suitable for water cooler in replacement of old capacitor, complete all as specified and directed by Engr-in-Charge Make : SHARDA/USHA/TESLA/SIMENS.
Supply and fixing of running capacitor upto 10 mfd suitable for compressor of water cooler/blower motor of any type AC in replacement of old capacitor, complete all as specified and directed by Engr-in-Charge Make : SHARDA/USHA/TESLA/SIMENS.
Supply and fixing of condensor coil suitable for water cooler 40/80 ltrs capacity as per existing size in replacement of old coil ,complete all as specified and directed by Engr-in-Charge.
Supply and fixing thermostat switch suitable for water cooler including knob plate and screw, in replacement of old thermostat switch, complete all as specified and directed by Engr-in-Charge. Make : INDFOS/RANUTROL/USHA/HI TECH.
Supply and fixing of condensor fan motor 1/5 HP including blades suitable for water cooler, in replacement of old motor, complete all as specified and directed by Engr-in-Charge. Make : AMERICAN UNIVERSAL/USHA/AIR MASTER/COOL MASTER.
Disconnecting of old defective burnt sealed compressor unit of water cooler of any capacity and supply and new sealed compressor unit including soldering of copper pipes, foundation of rubber bushes, nut bolts cleaning the refrigerant system, charging of compressor oil and refrigerant gas and testing, complete all as specified and directed by Engr-in-Charge.Make : KIRLOSKAR /GODREJ / LG/KELVINAT/Existing make
Preparation of old painted surfaces and applying one coat spray painting of synthetic enamel paint(colour as approved) outside and two coat of black bituminous paint inside of water cooler of any make after removal of all dust and all foreign matter with the help of sand paper and rubbing with cleaning compound, complete all as specified and directed by Engr-in-Charge.
Rewinding of fan motor of water cooler 40/80 ltrs capacity any make with super enameled copper wire or as per required including wornout bushes etc and testing after complete as per directed
Supply and fixing of PVC fan blade of motor of water cooler suitable for any make and capacity in replacement of old fan blade, complete all as specified and directed by Engr-in-Charge.
Testing of water cooler, cleaning the gas system with CTC of nitrogen vacuming properly and charging the refrigerant R-134a/as per existing required including the cost of gas filters/ rectification of leakage in entire system and making the gas system leak proof to the entire satisfaction of Engr-in-Charge, complete all as specified and directed by Engr-in-Charge.
S&F in replacemnt capillary tube made of copper any size suitable for Refrigerator/Water cooler/Deep freezer including taking out unsv capillary tube complete all as specified and directed.
SPLIT/WINDOW AC Maintenance, servicing and testing of split type AC, capacity upto 1.0/1.50/2 tons, any make, by cleaning cooling coil, condenser fins, blowing of dust from machines/air filters cleaning with VINICLEAN solution using pressure jet system with water, checking and decarbonising all electric system oiling/greasing of blower motor, checking and removing any vibration and leakage in the equipment including checking/repair to inter locking device for winter/summer to ensure cutting off of compressor/heating in case of failure of blower motor including taking down and refixing in position complete all as directed by Engineer-in-Charge.Note - (I) Cost of replacement of minor items such as nuts, bolts, washers, screws, rubber mounting pads of compressor etc is deemed to be inclusive in the unit rates quoted by the contractor.
Ditto All as per item no 40 above but for window Ac capacity 1.5/2.0 ton complete all as specified and direced by Engr-in-Charge.
Supply and fixing in replacement printed circuit board(PCB) kit for window type ac of any type complete all as specified and directed by Engr-in-Charge.
Ditto as per item No 42 but for split AC
Supply and fixing in replacement starting capacitor clip type of cap. 80-100 MFD,440 V AC 50 Hz suitable for 1.5/2 Ton capacity window/Split type AC complete all as directed by Engineer-in-Charge . Make- Kell/Tesla/Sharda/Escop
Supply and fixing in replacement starting capacitor clip type of cap. 120 MFD,440 V AC 50 Hz suitable for 1.5/2 Ton capacity window/Split type AC complete all as directed by Engineer-in-Charge. Make- Kell/Tesla/Sharda/Escop
S&F in replacement of running capacitor, 40 to 60 MFD suitable for 1.5 / 2.0 Ton capacity window/split type AC of approved Make : USHA/KELTRON/BHEL/KEL/TESLA or equivalent
Supply and charging gas refrigerant R-22/134a/410a or as per existing to window/split type AC upto 2 ton capacity including removing of leackage if any and testing complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement starting relay suitable for 1.0/1.5/2.0 ton capacity Ac complete all as specified and directed
Supply and fix in replacement over load protector relay suitable for 1.0/1.5/2.0 ton capacity Ac complete all as specified and directed
Supply and fix in replacement thermostat switch suitable for 1.0/1.5/2.0 ton capacity Ac complete all as specified and directed
S&F, in replacement, new compressor for window type AC 1.5 Ton capacity suitable for exsiting make including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after flushing the line with CO2 gas to avoid trapping the water vapour ensuring leak proof system complete all as specified and directed. Make: Shriram /Kirloskar /Voltas /Carrier / Whirlpool
S&F, in replacement, new compressor for window type AC 2 Ton capacity including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after flushing the line with CO2 gas to avoid trapping the water vapour ensuring leak proof system complete all as specified and directed. Make: Shriram/ Kirloskar/Voltas/Carrier/Whirlpool
S&F, in replacement, new reciprocating type compressor for 1.5 Ton capacity including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after flushing the line with CO2 gas to avoid trapping the water vapour ensuring leak proof system complete all as specified and directed. Make : Shriram/Kirloskar/Voltas/Carrier/Whirlpool/existing make
S&F, in replacement, new reciprocating type compressor for 2.0 Ton capacity including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after flushing the line with CO2 gas to avoid trapping the water vapour ensuring leak proof system complete all as specified and directed. Make: Shriram/ Kirloskar/Voltas/Carrier/Whirlpool/existing make
M&l for dismantling of existing air conditioner any type and capacity from its existing position complete and refixing the same at other location including charging of gas if required complete as per directed by Engr-in-Charge.
Supply and fix in replacement wiring kit suitable for 1.5/2.0 ton capacity Ac complete all as specified and directed.
Supply and fix in replacement air filter synthetic/nylon as per existing size and shape suitable for 1.5/2.0 ton capacity Window ACs complete all as specified and directed.
Supply and fix in replacement air filter synthetic/nylon as per existing size and shape suitable for 1.0/1.5/2.0 ton capacity Split type ACs complete all as specified and directed.
Supply and fix in replacement of new fan motor (indoor/outdoor) 1/4, 1/5 HP single/double shaft as per existing model suitable for split type Acs 1/1.5/2.0 ton complete all as specified and directed.
Materials and labour for rewinding of fan motor suitable for all types ACs upto 2.0 Ton capacity with super enameled copper winding wire of same guage including replacement of insulation materials bushes and shafts complete all as specified and directed.
Supply and fix in replacement PVC insulated flexible copper conductor 3 core 1100V grade of size 70/0.0076(2.5 sqmm) complete all as specified and directed.
Supply and fix in replacement of condensor fan blade made out of aluminium/plastic suitable for upto 2 ton capacity Window type ACs complete all as specified and directed.
Supply and fix in replacement of condensor fan blade made out of aluminium/plastic suitable for upto 2 ton capacity Split type ACs complete all as specified and directed.
Supply and fix against in replacement of evaporating air blower complete made out of aluminium/plastic suitable for upto 2 ton capacity Window type ACs complete all as specified and directed.
Supply and fix against in replacement of evaporating air blower complete made out of aluminium/plastic suitable for upto 2 ton capacity Split type ACs complete all as specified and directed.
M&L for replacement of synthetic rubber tube insulaton of thickness 9 mm & suitable for internal diameter 6.0 mm (1/4") for refrigerant copper piping of split AC units complete all as specified and directed. Make : Supreme/Gulf-o-flex/Superlon.
All as per item no 65 but internal dia 13 mm (1/2") complete all as specified and directed.
Supply and fixing in replacement copper tubing heavy duty inner dia 6.0 mm (1/4") for refrigerant For Acs Complete all as specified and directed.
Supply and fixing in replacement copper tubing heavy duty inner dia 13 mm (1/2") for refrigerant For Acs Complete all as specified and directed.
Supply and fixing in replacement copper tubing heavy duty inner dia 3/8" for refrigerant For ACs Complete all as specified and directed.
Supply and fixing in replacement copper tubing heavy duty inner dia 5/8" for refrigerant For ACs Complete all as specified and directed.
Supply and fixing in replacement, external/outdoor unit complete including compressor for split type AC 1.5/2.0 Ton capacity, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement, internal/indoor unit complete for split type AC 1.5/2.0 Ton capacity, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of drain water out pipe for split type ac Complete all as directed by Engr-in Charge.
COLD ROOM Servicing of cold room unit (04 Nos) incl 02 inner unit and 02 x outer units for each cold room with Filter Wash ,Cooling Coil Wash and remove the dust, replacement of minor parts , setting of tempurature as required by user to prevent life saving drugs, checking serviceability of tempurature control system for its serviceability , checking of serviceability of phase sequance corrector system including single phase preventor,checking of back pressure and head pressure of system and charging of gas to required level and all as directed by Engr-In-Charge Note:- Servicing will be carried out in every two months as per directed by Eng-in-Charge (04 Unitx5 = 20 Job)
Supply and fix in replacement 3 Phase contractor for upto 4 ton capacity outdoor unit of cold room including taking down unserviceable contractor complete all as specified and directed
Supply and fix in replacement over load protector relay suitable for 1.5/2.0 ton capacity Ac complete all as specified and directed
S&F, in replacement, new 3 phase compressor upto 4.0 Ton capacity suitable for cold room at MH including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after flushing the line with CO2 gas to avoid trapping the water vapour ensuring leak proof system complete all as specified and directed. Make: Kirloskar/Voltas/Carrier
Repair of voltage stabilizer of capacity upto 5 KVA, 20 Amp, AC, SP 230 Volts by rewinding of main transformer & electronic circuit including auto cut relays for desired voltage output from 135 to 300 Volts and stabilized to 230 volts to 240 volts including replacement of Volt meter, Amp meter, MCB 20/32 Amp, indicator lamp, main lead 3 metre long, 3 core 40/.0076, fuse grip, output connection including testing complete all as specified and directed.
Ditto as per item no 78 but for 3 KVA Voltage stabilizer
Ditto as per item no 78 but for 2 KVA Voltage stabilizer
Supply and replace metal clad/Sheet metal plug and socket with 2 pin earth plug and 20 Amp SP MCB 240 Volt complete including making all connections Make :- Havells or equivalent Legrand
Supply and replacement of indoor cooling coil fan complete made out of aluminium/plastic suitable for upto 4 ton capacity ACs complete all as specified and directed.
Supply and replacement of MCCB, thermal adjustable magnectic setting, Ics = 75% 25 kA, 415V, 40 Amp, 4 Pole MCCB with over load and short circuit protection, complete all as directed. , Make :- Havells / Legrand / ABB
Surendra Singh
vinayandsons
HARSH CONSTRUCTION CO.
M/s R K Enterprises
M/s Pankaj Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .