Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.2 LAccepted-AOC 364 MAHAVEERPURAM BEHIND FUN WORLD CHOPASNI ROAD JODHPUR RAJ | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹17.9 L+₹1.1 L (6.73%)Rejected-AOC PLOT NO 777 7TH CHOPASANI ROAD JODHPUR RAJASTHAN PIN 342003 | JODHPUR | JODHPUR | RAJASTHAN | 342003 | L2 | Rejected-AOC Not lowest | |
| 3 | L3₹19.4 L+₹2.6 L (15.3%)Rejected-AOC MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-AOC Not lowest | |
| 4 | L4₹19.9 L+₹3.1 L (18.5%)Rejected-AOC | L4 | Rejected-AOC Not lowest | |
| 5 | L5₹21.5 L+₹4.7 L (28.2%)Rejected-AOC | L5 | Rejected-AOC Not lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
1 Jun 2022, 6:00 pmClosed
GE (AF) Jodhpur
GE (AF) Jodhpur
REPAIR / REPLACEMENT OF STREET LIGHT, SECURITY LIGHT IN DOMESTIC AREA AT AF STN JODHPUR
2022_MES_521750_1
8519/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) Jodhpur
As per NIT
6 documents required · 6 mandatory
₹500
GE (AF) Jodhpur
₹40,000
Yes
17 Jun 2022
4 May 2022
3 Jun 2022
4 May 2022
1 Jun 2022
19 May 2022
Amount
Materal and labour for attending day to day street / security light (of any type, wattage and make, installed at various locations of DOMESTIC AREA at AF station jodhpur) complaints received through telephone or in person, identification and rectification of defects by bringing down the fittings on ground or in position including replacement of drivers, Surge Protection Device (SPD), replacement of old unserviceable light fittings/fixtures, cleaning of glass/acrylic cover for clear reflection of light, jumper fixing, tightening of loose connections, GI bracket tightening, checking the connection of FRP junction box, light alignment, MCB, MCCB, Contactor etc replacement of straight through joint and properly insulating the connections complete all as specified & directed by the Engineer-in-Charge. Note :- (i) Replacement of unserviceable items shall be measured and paid for seperately as 'Supply only' under respective items of this BoQ . (ii) contractor shall provide/depute sufficient number of electricians and helpers (as directed by Engineer-in-charge) to attend the complaints and rectified the same within 04 hours of receipt of complaints. (iii) contractors manpower shall attend daily to recieve complaints at complaint cell at 9.00 AM from JE E/M and report after completion of complaints and handover a complaint slip to JE E/M with user signature as a record of attending the complaints for payment purposes. (iv) Vehicle, ladder, tools, LT tapes and takes as required at site for repair/for making light fittings functional shall be provided by the contractor at his own cost and arrangement. (v) Any complaint/job given on a particular day shall be repaired/rectified within four hours on the same day. The rate of recovery against non attending/completing job on same day shall be Rs. 75/- per complaint per day. (vi) Old retrieved material shall be deposited in AGE E/M yard and shall be given to contractor after completion of contract.
Supply & fixing in repairs GI pipe bracket, made out of 40mm dia light grade GI pipe, fabricated into shape and size as required, not less than 1.2 metre long complete with two No MS clamps of MS flat iron 40mm x 6mm with bolts, nuts and washer fixed on poles/walls complete all as specified & directed by the Engineer-in-Charge.
Supply only 4 Sqmm 2 core, LT 1100 volts grade weather proof, PVC insulated and PVC sheathed, multi stranded aluminium conductor cable, flat type, in service connections etc complete all as specified & directed by the Engineer-in-Charge.
Supply only 6 Sqmm 2 core, LT 1100 volts grade weather proof, PVC insulated and PVC sheathed, multi stranded aluminium conductor cable, flat type, in service connections etc complete all as specified & directed by the Engineer-in-Charge.
Supply only 10 Sqmm 2 core, LT 1100 volts grade weather proof, PVC insulated and PVC sheathed, multi stranded aluminium conductor cable, flat type, in service connections etc complete all as specified & directed by the Engineer-in-Charge.
Supply only starter for fluorescent street light fitting 24 Watt complete all as specified & directed by the Engineer-in-Charge.
Supply only fluorescent tube lamp T5 type 24 watt for street light fitting 2x24 W/ 4x24 W complete all as specified & directed by the Engineer-in-Charge.
Supply only electronic ballast suitable for T5 HO lamps 2x24 watt/4x24 watt complete all as specified & directed by the Engineer-in-Charge.
Supply only lamp holder Single/Double ended suitable for HPSV/MH street light fittings of 1x 70/150/250/400 watt of make as per existing at site complete all as specified & directed by the Engineer-in-Charge.
Supply only copper ballast of capacity 150 watt for HPSV/MH street light fittings complete all as specified & directed by the Engineer-in-Charge.
Supply only copper ballast of capacity 250 watt for HPSV/MH street light fittings complete all as specified & directed by the Engineer-in-Charge.
Supply only copper ballast of capacity 400 watt for HPSV/MH street light fittings complete all as specified & directed by the Engineer-in-Charge.
Supply only metal halide lamp 250 watt single/double ended as per existing at site complete all as specified & directed by the Engineer-in-Charge. Make- Bajaj /Philips / Crompton Greaves
Supply only metal halide lamp 400 watt single/double ended as per existing at site complete all as specified & directed by the Engineer-in-Charge. Make- Bajaj /Philips / Crompton Greaves
Supply only metal halide lamp 150 watt single/double ended as per existing at site complete all as specified & directed by the Engineer-in-Charge. Make- Bajaj /Philips / Crompton Greaves
Supply only ignitor suitable for 70/150/250/400 watt MH/HPSV light fitting, complete all as specified & directed by the Engineer-in-Charge.
Supply only capacitor suitable for 70/150/250/400 watt MH/HPSV light fitting, complete all as specified & directed by the Engineer-in-Charge.
Trimming/cutting the tree branches/ bushes around the LT overhead line of each span more than 45 metre and making safe clearance up to 2.00 metre distance from line wire all as directed by Engineer-in-Charge. Note :- Measurement for the payment purpose shall be considered pole to pole distance as one span lenght irrespecitve of No of conductors between the poles.
Material and labour for unbinding ACSR conductor and insulators from the poles and restretching/restringing and fixing of same ACSR conductor on same poles and insulators and binding the same with and including new 2 mm dia aluminium binding wire including making/tightening of jumpers at appropriate place to ACSR Conductor at site all as specified and directed by Engineer-in-Charge. Note: All wires between pole to pole shall be restringed and measured as one length. Distance between pole to pole shall be considered for the purpose of payment.
Supply and fixing in replacement PVC cable Junction box for street light, pole mounting type of size 300mm x 300mm x 150mm or nearest size, central with linked door control, including one 6 Amps MCB SP with aluminium bus bar TPN for controlling the Street Lights complete, including mounting the junction box on pole with suitable arrangement with 02 nos MS clamp of MS flat iron 40x 6 mm, nuts & bolts complete all as specified & directed by the Engineer-in-Charge.
Supply only electric driver for 50 Watt LED type light fitting complete all as specified and directed by the Engineer-in-Charge.
Supply only electric driver for 75 Watt LED type light fitting complete all as specified and directed by the Engineer-in-Charge.
Supply only electric driver for 100 Watt LED type light fitting complete all as specified and directed by the Engineer-in-Charge.
Supply only electric driver for 150 Watt LED type light fitting complete all as specified and directed by the Engineer-in-Charge.
Supply only surge arrestor of 5KV/10KV for LED type fittings complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in replacement LED street light fitting 70 Watt with IP 66 protection and impact resistance of IK-07, 230 Volts, made up of pressure die cast aluminium housing with high efficient LED as lighting source, heat resistance toughned glass with frame, with potted driver & all connected acessories complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in replacement LED street light fitting 90 Watt with IP 66 protection and impact resistance of IK-07, 230 Volts, made up of pressure die cast aluminium housing with high efficient LED as lighting source, heat resistance toughned glass with frame, with potted driver & all connected acessories complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in replacement LED flood light fitting 150 Watt with IP 66 protection and impact resistance of IK-07, 230 Volts, made up of pressure die cast aluminium housing with high efficient LED as lighting source, heat resistance toughned glass with frame, with potted driver & all connected acessories complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in replacement LED flood light fitting 200 Watt with IP 66 protection and impact resistance of IK-07, 230 Volts, made up of pressure die cast aluminium housing with high efficient LED as lighting source, heat resistance toughned glass with frame, with potted driver & all connected acessories complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in replacement LED street light fitting 120 Watt with IP 66 protection and impact resistance of IK-07, 230 Volts, made up of pressure die cast aluminium housing with high efficient LED as lighting source, heat resistance toughned glass with frame, with potted driver & all connected acessories complete all as specified and directed by the Engineer-in-Charge.
Material and labour for attending day to day complaints of existing 12 m high highmast light (of any type, make and wattage installed at various locations in DOMESTIC AREA at AF station jodhpur) received through telephone or in person, identification and rectification of defects by bringing down the fittings on ground or in position including replacement of flexible wire, MH choke, MH/Sodium lamp, ignitor, lamp holder, driver, SPD, PCB, Contactor, MCB, MCCB replacement of old unserviceable light fittings, cleaning of glass/acrylic cover for clear reflection of light, jumper fixing, tightening of loose connections, GI bracket tightening, checking the connection of FRP junction box, light alignment etc, properly insulating the connections complete all as specified & directed by the Engineer-in-Charge. Note :- (i) Replacement of unserviceable items shall be measured and paid for seperately as 'Supply only' under repective items of this BoQ . (ii) contractor shall provide/depute sufficient number of electricians and helpers (as directed by Engineer-in-charge) to attend the complaints and rectified the same within 04 hours of receipt of complaints. (iii) contractor manpower shall attend daily to recieve complaints at complaint cell at 9.00 AM from JE E/M and report after completion of complaints and handover a complaint slip to JE E/M with user signature as a record of attending the complaints for payment purposes. (iv) Vehicle, ladder, tools, LT tapes and takes as required at site for repair/for making light fittings functional shall be provided by the contractor at his own cost and arrangement. (v) Any complaint/job given on a particular day shall be repaired/rectified within four hours on the same day. The rate of recovery against non attending/completing job on same day shall be Rs. 75/- per complaint per day. (vi) Old retrieved material shall be deposited in AGE E/M yard and shall be given to contractor after completion of contract.
Material & labour for repair of mechanism of High mast and rewinding of three phase tower motor 440 volt AC including dismantling from high mast & transport to workshop for rewinding with existing size of super enameled copper wire, replacing of gear, bearing bush etc for running of rope at satisfoctory level and reinstallation complete all as specified and directed.
Supply, Laying, Testing and Commissioning in replacement of LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 16 Sqmm 04 core (heavy duty) 1100 Volts grade with stranded Aluminium conductor complete all as specified by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning in replacement of LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 25 Sqmm 04 core (heavy duty) 1100 Volts grade with stranded Aluminium conductor complete all as specified by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 metres wide and not exceeding 1.5 metres in depth for foundation/cable trench/laying of pipe line/taking out pipe/cable cover etc and getting out in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Supply & fixing in repairs 50 mm bore galvanised steel tubes, light grade for cable protection fixed on walls including all rquired fitting and fixtures complete all as specified & directed by the Engineer-in-Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layer not exceeding 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil to a distance not exceeding 50 metres and deposing where directed at a level not exceeding 1.5 metres above the starting point complete all as specified and directed by Engineer-in-charge.
Material & labour for sand cushioning for PVC cable with tibba sand (one layer of 80 mm thickness before laying of cable and other layer of 150 mm thickness after laying of cable) & punning down to 180 mm to provide a required cover complete all as specified and directed by the Engineer-in-Charge. Note:- Punned thickness only shall be measured and paid.
Labour only for rough dressed Jodhpur type stone slab cover retrieved from excavation, laid dry abutting each other for protection of cable complete all as specified and directed.
Material & labour for Boring of holes under road, pavements, hard standing; manually with suitable boring tools as required at site, and including providing GI pipe light grade 50mm dia complete all as specified and directed.
Supply and fixing in repairs Aviation obstruction LED light fitting 240 volt low intensity twin aviation light of power consumption 10 watt in total, including fixing arrangement complete all as specified and directed by the Engineer-in-Charge.
Material & Labour for Pre-stressed concrete poles 9 metres long, size 152 mm x 152 mm at top and 152 mm x 260 mm at bottom, class 10, complying with requirement of IS-1678 of 1978 including painting the poles with two coats of synthetic enamel paint over a coat of primer in sky blue and white (15 cm high each) alternate strips upto 1.5 m height from top of PCC coping including numbering the poles in synthetic enamel paint, including necessary excavation & earthwork in any type of soil, PCC (1:4:8) in foundation , PCC (1:3:6) in coping , with and including dismantling & breaking the old PCC foundation,taking out of old unserviceable pole, and removal of all the debries out side MD land complete all as directed by the Engineer-in-Charge.
Supply & fixing in repairs three Pole Contactor 25/50Amp 240Volts AC complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repairs two Pole Contactor 40/63/75Amp 240Volts AC complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repairs MCBs of 'C' series, SP, 6 to 32 Amps having breaking capacity 10 KA, including required wiring connections with copper lugs of suitable size complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repairs MCBs of 'C' series, SPN, 32 Amps having breaking capacity 10 KA, including required wiring connections with copper lugs of suitable size complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repairs MCCB four pole 63 Amps, thermally adjustable between 70 to 100% including 4 spreader link set of same make as that of MCCB for connection, including lugs as required complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repairs MCCB four pole 100 Amps, thermally adjustable between 70 to 100% including 4 spreader link set of same make as that of MCCB for connection, including lugs as required complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repairs Automatic street light switch using NATURE SWITCH for automatic switching of street light based on lux level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (input- output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric proof, termite proof and FR grade SMC junction box conforming to IP-54 the contactors, MCBs and copper circuit wiring should be enough to take three phase load of 8KW, Contactor Rating 25-32Amps, MCB SP 32Amps, complete all as specified and directed by the Engineer-in-Charge. Make:- Nature Switch-Kakatiya energy systems/Bajaj/Healer.
Supply & fixing in replacement PVC insulated copper cable of 2.5 Sqmm 2 core complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in replacement PVC conduit of 20mm from junction box to GI pole complete all as specified & directed by the Engineer-in-Charge.
KAMAL ENTERPRISES
M/S KAUTILYA GARG
LOKESH ELECTRICAL WORKS CONTRACTOR
Narendra General Suppliers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .