| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹25.6 LAccepted-AOC | 1 | Accepted-AOC Being the lowest bidder. | |
| 2 | 2₹30.5 L+₹4.8 L (18.8%)Rejected-AOC | 2 | Rejected-AOC Being other than the lowest bidder. | |
| 3 | 3₹31.7 L+₹6.0 L (23.6%)Rejected-AOC H1 7 8 IT PARK ROAD NO 4 IPIA KOTA RAJ 324005 | KOTA | RAJASTHAN | 324005 | 3 | Rejected-AOC Being other than the lowest bidder. | |
| 4 | 4₹32.3 L+₹6.7 L (26.1%)Rejected-AOC 70 VARDHMAN NAGAR A P O SHYAM NAGAR AJMER ROAD JAIPUR PIN 342019 | JAIPUR | 342019 | 4 | Rejected-AOC Being other than the lowest bidder. | |
| 5 | 5₹37.4 L+₹11.8 L (45.9%)Rejected-AOC | 5 | Rejected-AOC Being other than the lowest bidder. |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
13 Jan 2020, 6:00 pmClosed
CWE KOTA
HQ CWE Kota Military Engineer Services Dadwara Military Station Kota Rajasthan PIN 324002
CWE KOTA/KOTA-61 OF 2019-20 SPL REPAIR/REPLACEMENT/CONVERSION OF LT OH LINES TO UG CABLE IN GTC AND MH AREA AT MIL STN KOTA
2019_MES_305779_1
81543/KOTA/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
kota
For Enlisted Contractors Class D Category b i and for unenlisted contractors meeting enlistment criteria for required Class and Category
7 documents required · 7 mandatory
₹500
GE KOTA
₹84,000
Yes
8 Feb 2020
11 Dec 2019
15 Jan 2020
11 Dec 2019
13 Jan 2020
31 Dec 2019
11 Dec 2019 - 21 Dec 2019
Amount
Dismantling and taking down ACSR Conductors of any size from poles complete all as specified and directed.
Distmantling and taking down LT old insulator any type any size, any make from cross arms/poles etc. complete all as specified and directed.
Distmantling and taking down old cross arms of MS channel or angle sections etc.and setting aside for re-use within 50 metre complete all as specified and directed.
Distmantling of unserviceable Junction Box, complete all as specified and directed.
Distmantling and taking down old PCC LT Pole, complete all as specified and directed.
Dismantling of unserviceable MCB DB TPN of any size, complete all as specified and directed.
Excavation in trenches, not exc 1.5 m wide and n. exc 1.50 m or n exc 10 Sqm on plan & getting out, for laying of cables, foundations of poles, struts, stays etc. and getting out soft/loose soil including triming and forming bottom surface complete, all as specified and directed.
Excavation in trenches, exc 1.5 m wide and n. exc 3.00 m or n exc 10 Sqm on plan & getting out, for laying of cables, foundations of poles, struts, stays etc. and getting out soft/loose soil including triming and forming bottom surface complete, all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in soil back in trenches after cables have been laid and tested, poles, stays , struts have been erected and tested complete all as directed.
Removing excavated materials to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point in soils complete all as directed.
S&F LT UG cable and Supply/Lying / fixing, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE insulated & PVC sheathed cable heavy duty armoured, with multistranded aluminium conductor laid in trenches/ ducts/ pipes/fixed on walls/poles complete all as specified and directed for following size cables :-
3.5 core 240 Sqmm
3.5 core 185 Sqmm
3.5 core 70Sqmm
4 core 35 Sqmm
4 core 25 Sqmm
2 core 10 Sqmm NOTE :- (a) Excavation & earth work for laying cable shall be measured and paid for seprately under respective items of this BOQ. (b) GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid for seprately under respective items of the schedule (c) Road cutting involved during excavation for laying of cables etc shall be made good as per existing road. Nothing extra shall be admissible on this account. Quoted rates of the item shall be inclusive of the above provisions.
M&L for PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in coping to the pole complete all as specified and directed.
Boring of holes under road, paverment, hardstanding by trenchless technology using ultra sound technique and necessary machine indluding HDPE pipe of 80mm dia suitable for 0.4 mpa working pressure complete all as directed.
Boring of holes under road, paverment, hardstanding by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 100mm dia suitable for 0.4 mpa working pressure complete all as directed.
M & L for PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundation, filling and mass concrete making good to cheses/cutting in floor etc and exposed concrete surface finished fair and even complete all as specified and directed.
Supplying, transporting to site errecting and fixing in position Steel tubular swaged pole, 9.00 metres long, type 410 SP-31 complete with cast iron base plate, pole cap, finial taper plug, bolts, nuts, washers etc including painting with two coats of aluminium paint over one coat of red oxide primer including 3 nos band/straps in red post office box colour (300mm wide EACH) using fluorescent paint commencing at a distance 300mm from padestal of pole and marking pole nos with black synthetic enamelled paint including tarring one coat on steel surface embedded in concrete complete all as directed. Note:- Excavation and earth work, PCC etc shall be measured and paid separately under respective items.
M & L sand cushioning for under ground cable 23cm thick (one layer of 8cm thickness before laying the cable and other layer of 15cm thickness after laying the cable) all as directed. (NOTE- Thickness after punning shall be considered for payment.)
M&L for burnt bricks, sub class B bricks old size laid dry in trenches across the cable protection and flat abutting each other with gaps between adjacent bricks not exceeding 10mm with width equal to length complete all as specified and directed by Engineer-in-Charge.
S & F 40mm bore steel water tubing, Light grade, with all fittings, protection for UG XLPE laid in trenches complete all as specified and directed.
S & F 50mm bore steel water tubing, galvanized, Light grade, with all fittings, protection for UG XLPE laid in trenches complete all as specified and directed.
S & F 80mm bore steel water tubing, galvanized, Light grade, with all fittings, protection fixed on walls/poles/laid in trenches complete including dismantling of old unserviceable pipe complete all as specified and directed.
S & F 100mm bore steel water tubing, galvanized, Light grade, with all fittings, protection fixed on walls/poles/laid in trenches complete including dismantling of old unserviceable pipe complete all as specified and directed.
Supply & fixing of Junction box made out of 2 mm thick CRCA sheet of size 250mmx250mmx150mm with hinged door and locking arrangement including aluminium bus bar of size 25x3mm three phase & neutral fixed on insulator, including one No MCB SP 6 Amps & painting the box with two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed.
Supply and fix in repair new generation energy saving & environmental friendly long life versatile pressure die cast aluminium IP 66 roadway luminaire with high power LED as light source and electronic driver of capacity 72 watt, complete all as specified and directed. Make : HAVELLS Cat No LHFAXU7DPN6J070 or equivalent in Philips/Wipro.
Supply and draw PVC insulated unsheathed copper conductor cable 1.5 sqmm 3 runs from street light fitting to junction box on pole of 9 meters and making necessary connection both at junction box and street light fittings including suitable size PVC conduit and fixing accessories complete all as specified and directed.
M & L MCCB, three pole 315 Amps, 36 KA , adjustable type, microprocessor based 415 volts, 50 Hz, complete all as specified and directed. Make - Legrand/L&T/Havells
S & F sheet metal enclosure double door vertical type DB TPN 04 ways, 415volts protection class IP-43 made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted confirming to IS-13032, IS 8623, BS-5484 with tinned copper bus bar of 200 Amps capacity including one number MCCB TPN 63 Amps 16 KA, 415 Volts (as incomer) all as specified and directed. Note:- The unit rate includes for making good the disturbed surfaces including finishes to match with the adjoining surface.
M & L for outdoor type heat shrinkable cable end termination jointing kit for HT 11000 Volts(Earthed) grade cable of size 185 Sqmm, 3.5 core XLPE complete with jointing material and accessories complete all as specified and directed.
M&L bus bar chamber and enclosures of size 1.2x1.2x0.6 mtrs outdoor type factory made of 0.6 mm thick MS sheet powder coated comprising of copper bus bar 400 Amp rated two number copper strips and including PCC foundation, complete all as specified and directed.
(c) Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road level. Notes :- (a) All armoured cables shall enter through bottom of the feeder pillar duly glanded and socketed and connected to MCCB/cable terminal. Cost of glanding socketing etc are deemed to be included in the unit rate of feeder pillar. (b) All the out going cable shall be terminated in bakellite cable connector and shall be duly glanded and socketed. (c) All the cables (power and control wiring ) should be terminated duly socketed with heavy duty tinned copper lugs, GI bolts/screws nuts, flat washers and spring washers as required. (d) White acrylic marker plate (for feeder / switch marking ) to be provided with black lettering by heat press machine as indicated in drawing and to be pasted over the panel door/near the cable connector with high quality adhesive. (e) The cost of platform/foundation with PCC shall deemed to be included in the quoted rates. (f) The consolidated rate for Srl No.30.00 & 30.10 shall be quoted against Srl No.30.00 of BOQ. (g) Location of Panel marked as B, C, D in Drg No. 01.
(c) Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road level. Notes :- (a) All armoured cables shall enter through bottom of the feeder pillar duly glanded and socketed and connected to MCCB/cable terminal. Cost of glanding socketing etc are deemed to be included in the unit rate of feeder pillar. (b) All the out going cable shall be terminated in bakellite cable connector and shall be duly glanded and socketed. (c) All the cables (power and control wiring ) should be terminated duly socketed with heavy duty tinned copper lugs, GI bolts/screws nuts, flat washers and spring washers as required. (d) White acrylic marker plate (for feeder / switch marking ) to be provided with black lettering by heat press machine as indicated in drawing and to be pasted over the panel door/near the cable connector with high quality adhesive. (e) The cost of platform/foundation with PCC shall deemed to be included in the quoted rates. (f) The consolidated rate for Srl No.31.00 & 31.10 shall be quoted against Srl No.31.00 of BOQ. (g) Location of Panel marked as Main LT Panel in Drg No. 01.
(c) Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road level. Notes :- (a) All armoured cables shall enter through bottom of the feeder pillar duly glanded and socketed and connected to MCCB/cable terminal. Cost of glanding socketing etc are deemed to be included in the unit rate of feeder pillar. (b) All the out going cable shall be terminated in bakellite cable connector and shall be duly glanded and socketed. (c) All the cables (power and control wiring ) should be terminated duly socketed with heavy duty tinned copper lugs, GI bolts/screws nuts, flat washers and spring washers as required. (d) White acrylic marker plate (for feeder / switch marking ) to be provided with black lettering by heat press machine as indicated in drawing and to be pasted over the panel door/near the cable connector with high quality adhesive. (e) The cost of platform/foundation with PCC shall deemed to be included in the quoted rates. (f) The consolidated rate for Srl No.32.00 & 32.10 shall be quoted against Srl No.32.00 of BOQ. (g) Location of Panel marked as NO-1 in Drg No. 02.
(c) Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road level. Notes :- (a) All armoured cables shall enter through bottom of the feeder pillar duly glanded and socketed and connected to MCCB/cable terminal. Cost of glanding socketing etc are deemed to be included in the unit rate of feeder pillar. (b) All the out going cable shall be terminated in bakellite cable connector and shall be duly glanded and socketed. (c) All the cables (power and control wiring ) should be terminated duly socketed with heavy duty tinned copper lugs, GI bolts/screws nuts, flat washers and spring washers as required. (d) White acrylic marker plate (for feeder / switch marking ) to be provided with black lettering by heat press machine as indicated in drawing and to be pasted over the panel door/near the cable connector with high quality adhesive. (e) The cost of platform/foundation with PCC shall deemed to be included in the quoted rates. (f) The consolidated rate for Srl No.33.00 & 33.10 shall be quoted against Srl No.33.00 of BOQ. (g) Location of Panel marked as No. 04 in Drg No. 02.
(c) Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road level. Notes :- (a) All armoured cables shall enter through bottom of the feeder pillar duly glanded and socketed and connected to MCCB/cable terminal. Cost of glanding socketing etc are deemed to be included in the unit rate of feeder pillar. (b) All the out going cable shall be terminated in bakellite cable connector and shall be duly glanded and socketed. (c) All the cables (power and control wiring ) should be terminated duly socketed with heavy duty tinned copper lugs, GI bolts/screws nuts, flat washers and spring washers as required. (d) White acrylic marker plate (for feeder / switch marking ) to be provided with black lettering by heat press machine as indicated in drawing and to be pasted over the panel door/near the cable connector with high quality adhesive. (e) The cost of platform/foundation with PCC shall deemed to be included in the quoted rates. (f) The consolidated rate for Srl No.34.00 & 34.10 shall be quoted against Srl No.34.00 of BOQ. (g) Location of Panel No. 05 marked in Drg No. 02.
(c) Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road level. Notes :- (a) All armoured cables shall enter through bottom of the feeder pillar duly glanded and socketed and connected to MCCB/cable terminal. Cost of glanding socketing etc are deemed to be included in the unit rate of feeder pillar. (b) All the out going cable shall be terminated in bakellite cable connector and shall be duly glanded and socketed. (c) All the cables (power and control wiring ) should be terminated duly socketed with heavy duty tinned copper lugs, GI bolts/screws nuts, flat washers and spring washers as required. (d) White acrylic marker plate (for feeder / switch marking ) to be provided with black lettering by heat press machine as indicated in drawing and to be pasted over the panel door/near the cable connector with high quality adhesive. (e) The cost of platform/foundation with PCC shall deemed to be included in the quoted rates. (f) The consolidated rate for Srl No.35.00 & 35.10 shall be quoted against Srl No.35.00 of BOQ. (g) Location of Panel marked as No. 03 in Drg No. 02.
(c) Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road level. Notes :- (a) All armoured cables shall enter through bottom of the feeder pillar duly glanded and socketed and connected to MCCB/cable terminal. Cost of glanding socketing etc are deemed to be included in the unit rate of feeder pillar. (b) All the out going cable shall be terminated in bakellite cable connector and shall be duly glanded and socketed. (c) All the cables (power and control wiring ) should be terminated duly socketed with heavy duty tinned copper lugs, GI bolts/screws nuts, flat washers and spring washers as required. (d) White acrylic marker plate (for feeder / switch marking ) to be provided with black lettering by heat press machine as indicated in drawing and to be pasted over the panel door/near the cable connector with high quality adhesive. (e) The cost of platform/foundation with PCC shall deemed to be included in the quoted rates. (f) The consolidated rate for Srl No.36.00 & 36.10 shall be quoted against Srl No.36.00 of BOQ. (g) Location of Panel marked as -A in Drg No. 01.
(c) Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road level. Notes :- (a) All armoured cables shall enter through bottom of the feeder pillar duly glanded and socketed and connected to MCCB/cable terminal. Cost of glanding socketing etc are deemed to be included in the unit rate of feeder pillar. (b) All the out going cable shall be terminated in bakellite cable connector and shall be duly glanded and socketed. (c) All the cables (power and control wiring ) should be terminated duly socketed with heavy duty tinned copper lugs, GI bolts/screws nuts, flat washers and spring washers as required. (d) White acrylic marker plate (for feeder / switch marking ) to be provided with black lettering by heat press machine as indicated in drawing and to be pasted over the panel door/near the cable connector with high quality adhesive. (e) The cost of platform/foundation with PCC shall deemed to be included in the quoted rates. (f) The consolidated rate for Srl No.37.00 & 37.10 shall be quoted against Srl No.36.00 of BOQ. (g) Location of Panel marked as NO-2 in Drg No. 02.
M & L for earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6 mm thick buried vertically in ground to depth not less than 2.25 metres deep below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to galvanized strip 32 x 6mm earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel besides welding at all joints as shown in drawing and including excavation and earth work, GI pipe light grade 40mm bore for protection of strip and connected to continous earth lead on pole/test point, supplying and laying charcoal dust common salt PCC 1:2:4 type B1, chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20mm dia GI pipe medium grade for watering all as shown in electrical plate No 3 on srl page No 497 of SSR Part I (2009) drawing and connection to earth test point including testing complete all as specified and directed. Notes :- (i) Outer edge of earth pit shall be 1 metre away from the outer edge of PCC chamber. (ii) The cost of earth lead /strip and GI pipe for protection of earth lead/strip upto 7.5m is included in the quoted rate. (iii) The cost of excavation, earth work is included in the quoted rate.
M/s Prem Associates
Aditya Enterprises
Pioneer Enterprises
K B Enterprises
M/S GAURI CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .