Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.5 LAdmitted-Finance 81 82 GHER SAIKH MITHOO KUBRHI PAKHAR ZAKHERA BAREILLY UP | BAREILLY | BAREILLY | UTTAR PRADESH | ₹28.5 L | L1 | Admitted-Finance |
| 2 | L2₹29.7 LAdmitted-Finance 63 TALLA GAON POST UNCHAKOT DISTT NAINITAL 263134 UK | NAINITAL | NAINITAL | UTTARAKHAND | 263134 | ₹29.7 L | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | shahji contractors L1 | JAGAT POWER ELCTRICAL L2 |
|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 in depth for foundation of poles, stay assy etc. and getting out in hard / dense soil complete all as specified and directed. | 188 | CUM | 600 ₹1,12,800 | 500 ₹94,000 |
| 2.00 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 mtr in depth for foundation. (Laying of under ground cables) in hard rock and getting out all as directed. | 1 | CUM | 2,500 ₹2,500 | 2,200 ₹2,200 |
| 3.00 | Material and labour for laying DWC (Double wall corrugated ) pipe conforming or IS 16205 (electric cable use) of nominal outer dia min 100 mm and suitable for 95 Sqmm HT Cable for laying electrical cables under trenches / under road/ wall complete all as specified and directed. | 500 | RM | 400 ₹2,00,000 | 400 ₹2,00,000 |
| 4.00 | Returning filling in including spreading levelling watering and well ramming in layers not exc. 25 cm thick each complete all as specified and directed | 162 | CUM | 150 ₹24,300 | 90 ₹14,580 |
| 5.00 | Removing excavated material to a distance not exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point of any type of soil complete all as specified and directed | 27 | CUM | 150 ₹4,050 | 250 ₹6,750 |
| 6.00 | M&L for sand cushning to U/G cable in layers of 23cm thick (8 Cm before laying the cable and 15 cm thick after laying the cable) in trenches including watering and consolidation, complete all as specified and directed. Note: Only punned thickness 18 cm shall be measured and paid. | 8.1 | Cum | 2,200 ₹17,820 | 19 ₹153.9 |
| 7.00 | Supply and laying reinforcecd precast concrete cable cover, class HV, type1, flat, size 300mm x 180mm x 40mm laid in trenches flat complete all as specified and directed. | 500 | Each | 30 ₹15,000 | 25 ₹12,500 |
| 8.00 | Supply & laying in replacement of GI tubing of 80 mm bore dia, light grade conforming to IS 1239- Part-I and ISI marked in trenches, across the road, on wall or poll including fixing arrangements, culvert etc of required length for cable protection complete all as specified and directed. | 15 | RM | 600 ₹9,000 | 350 ₹5,250 |
| 9.00 | Taking out carefully unserviceable HT cable up to 95 Sqmm from trenches and relaying same after repairs in same or other indicated location incl laying old bricks received from site after testing complete all as directed by Engr-in-Charge. (Excavation and returning filling will measured and paid separately) | 350 | RM | 100 ₹35,000 | 5 ₹1,750 |
| 10.00 | Supply, laying in trenches or passing through pipe/ducts, fixed to wall or poles XLPE insulated screened PVC sheathed galvanized steel strip or wire armoured electric power cable with alumn conductor of cross sectional area 95 Sqmm 3 core 11 KV rated suitable for earthed system including testing and commissioning including taking down old u/s HT cable all as specified and directed Note : (Excavation and earth work, sand cushioning brick covers and GI pipe etc shall be measured and paid separately. | 400 | RM | 1,700 ₹6,80,000 | 1,900 ₹7,60,000 |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
23 Jun 2026, 6:00 pmClosed
CWE (HILLS) PITHORAGARH
HQ CWE (HILLS) PITHORAGARH POST OFFICE - BHARKATIA DISTRICT - PITHORAGARH STATE - UTTARAKHAND PIN 262520
CA NO. CWE/HILLS/EWS/20 OF 2026-2027 PERIODIC MAINTENANCE/ REPAIR OF TRANSFORMERS AND CALIBRATION OF SWITCH GEARS, HT CABLE, HT DISTRIBUTION NETWORK AT GE 871 EWS
2026_MES_767834_1
89418/26-27/E8
Open Tender
Civil Works
270 days
JOSHIMATH
Class - D
9 documents required · 9 mandatory
₹500
GE 871 EWS
₹68,000
Yes
3 Jul 2026
26 May 2026
30 Jun 2026
26 May 2026
23 Jun 2026
9 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 in depth for foundation of poles, stay assy etc. and getting out in hard / dense soil complete all as specified and directed. | 188 | CUM | - | - |
| 2 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 mtr in depth for foundation. (Laying of under ground cables) in hard rock and getting out all as directed. | 1 | CUM | - | - |
| 3 | Material and labour for laying DWC (Double wall corrugated ) pipe conforming or IS 16205 (electric cable use) of nominal outer dia min 100 mm and suitable for 95 Sqmm HT Cable for laying electrical cables under trenches / under road/ wall complete all as specified and directed. | 500 | RM | - | - |
| 4 | Returning filling in including spreading levelling watering and well ramming in layers not exc. 25 cm thick each complete all as specified and directed | 162 | CUM | - | - |
| 5 | Removing excavated material to a distance not exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point of any type of soil complete all as specified and directed | 27 | CUM | - | - |
| 6 | M&L for sand cushning to U/G cable in layers of 23cm thick (8 Cm before laying the cable and 15 cm thick after laying the cable) in trenches including watering and consolidation, complete all as specified and directed. Note: Only punned thickness 18 cm shall be measured and paid. | 8.1 | Cum | - | - |
| 7 | Supply and laying reinforcecd precast concrete cable cover, class HV, type1, flat, size 300mm x 180mm x 40mm laid in trenches flat complete all as specified and directed. | 500 | Each | - | - |
| 8 | Supply & laying in replacement of GI tubing of 80 mm bore dia, light grade conforming to IS 1239- Part-I and ISI marked in trenches, across the road, on wall or poll including fixing arrangements, culvert etc of required length for cable protection complete all as specified and directed. | 15 | RM | - | - |
| 9 | Taking out carefully unserviceable HT cable up to 95 Sqmm from trenches and relaying same after repairs in same or other indicated location incl laying old bricks received from site after testing complete all as directed by Engr-in-Charge. (Excavation and returning filling will measured and paid separately) | 350 | RM | - | - |
| 10 | Supply, laying in trenches or passing through pipe/ducts, fixed to wall or poles XLPE insulated screened PVC sheathed galvanized steel strip or wire armoured electric power cable with alumn conductor of cross sectional area 95 Sqmm 3 core 11 KV rated suitable for earthed system including testing and commissioning including taking down old u/s HT cable all as specified and directed Note : (Excavation and earth work, sand cushioning brick covers and GI pipe etc shall be measured and paid separately. | 400 | RM | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
BOQ_859876.xls
BOQ • 0.41 MB
PS20.pdf
Tender Documents • 1.30 MB
Download all tender documents and submit your bid