Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 CrAccepted-AOC | ₹13.7 Cr Quoted ₹13.8 Cr | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹14.8 CrRejected-Finance BLDG NO 22 2079 COAST GUARD ROAD NEAR COAST GUARD FAMILY ACCOMMODATION MUNDAMVELI PO PALLURUTHY VII ERNAKULAM 682 507 | ERNAKULAM | ERNAKULAM | KERALA | 682507 | ₹14.8 Cr | L2 | Rejected-Finance BEING L2 |
| 3 | l3₹16.9 CrRejected-Finance | ₹16.9 Cr | l3 | Rejected-Finance BEING L3 |
| 4 | L4₹17.6 CrRejected-Finance | ₹17.6 Cr | L4 | Rejected-Finance BEING L4 |
Tender Value
Refer Docs
Closing Date
28 Oct 2021, 6:00 pmClosed
CE NW KOCHI
CE NW KOCHI KATARIBAGH NAVAL BASE PO KOCHI-04
PROVISION OF DEFICIENT INTEGRATED SECURITY WATCH TOWERS AT NAVAL STATION EZHIMALA.
2021_MES_458650_1
890954/E8
Open Tender
Civil Works
545 days
EZHIMALA
As per nit
7 documents required · 7 mandatory
₹3,000
Yes
Exempted
14 Dec 2021
10 Jul 2021
1 Nov 2021
10 Jul 2021
28 Oct 2021
13 Oct 2021
10 Jul 2021 - 4 Aug 2021
Amount
Total amount of Sch 'A' part-I ( Buildings/Structures)
Total amount of Sch 'A' part-II (Excavation, earthwork,Site Develoment)
Total amount of Sch 'A' part-III (Internal Electrification)
Total amount of Sch 'A' part-IV (Internal water Supply)
Total amount of Sch 'A' part-V (External Water Supply)
Total amount of Sch 'A' part-VI ( External Electrification)
Total amount of Sch 'A' part-VII ( Road/Path/Culvert)
Total amount of Sch 'A' part-VIII (Area Drainage)
Total amount of Sch 'A' part-IX (Sewage Disposal)
Total amount of Sch 'A' part-X (Retaining wall)
Total amount of Sch 'A' part- XI (Lightning Protection)
SCH. 'A' PART -XII (MISCELLANEOUS) Note :- This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Drilling/Boring for cast-in-situ bored piles of 450mm outer dia to any depth through any type of soil/strata like soft/loose soil,hard/dense soil,stiff clay,sand,cobble stone,soft conglomerate,loose boulders (except rock for founding depth) by DMC method using bentonite slurry including removal of bored materials to place outside MD land all as specified and as directed.(Note:-The rate shall include mobilisation,erection,dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation/demobilisation of equipment seperately.)
Drilling/Boring for cast-in-situ bored piles of 450mm outer dia to any depth through any type of soil/strata like hard rock (Socketing 0.50 mm in hard rock for each pile) by DMC method using bentonite slurry including removal of bored materials to place outside MD land all as specified and as directed (Note:-The rate shall include mobilisation,erection,dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation/demobilisation of equipment seperately.)
RCC with ready mix concrete(RMC) M30 grade with min 400Kg cement per cum in cast in situ bored pile of any length/any sections complete all as specified and as shown on drg including non destructive integrity test on all pile as per IS 2911 part IV.(Note:-(i) Reinforcement will be measured and paid separately under relevant items )
RCC with ready mix concrete(RMC) M30 grade in pile cap , grade beam & tie beam complete all as specified and shown on drg. (Note:-(i) Reinforcement will be measured and paid separately under relevant items )
CRS/HCRS/CRM TMT bars in reinforcement 10mm dia and over for bored pile including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs .
CRS/HCRS/CRM TMT bars 5mm to 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and shown on drgs as in Helical.
CRS/HCRS/CRM TMT bars in reinforcement 10mm dia and over including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs as in grade beams, tie beam,slab and pile caps.
CRS/HCRS/CRM TMT bars 5mm to 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and shown on drgs as in stirrups of grade beams.
PCC (1:4:8) type D2 using 40mm graded stone aggregate for concrete layer below pile caps/grade beams and foundation complete all as specified and shown on drgs.
Formwork to sides of pile caps,grade beams,tie beams rough finished surface of concrete flat all as specified .
Conducting Standard Panetration Test all as per IS-2131 at levels and locations as directed for 450 mm dia cast in situ bored piles completed all as specified and directed.
Providing testing equipment & load and testing of 450mm dia bored pile (Initial Load test safe load capacity 23t) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 450mm dia bored pile (Initial Load test safe load capacity 85t) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 450mm dia pile (Routine Load test for 23t) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 450mm dia pile (Routine Load test for 85t) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep or area not exceeding 10 sqm on plan in soft/loose soil including bailing out/pumping out water on account of spring/rain or any other causes using any method as required and as directed by Engr-in-Charge for pile caps/plinth beams/tie beam etc all as specified and shown on drawings.
Returning filling in around pile cap, plinth beams, raft foundation etc using excavated soil including spreading levelling and well ramming in layers not exc 25 cm thick all as specified and directed.
Removal of excavated soil to a distance exceeding 1.5Km but not exc. 5.0Km and depositing where directed complete all as specified and as directed.
INTERNAL ELECTRIFICATION :- Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No. with and including heavy duty non metalic regid PVC concealed conduit and conduit accessories concealed in wall/roof/floor or fixed on truss etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories),including modular GI flush box of suitable size with inner and outer white plastic plate (same make of approved switch and socket) including one run of PVC insulated multi-stranded copper conductor 1.5 Sqmm nominal cross sectional area single core F.R.L.S. cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the following:- (NOTE: (i) Switches, sockets, regulators to be measured and paid for separately.
(a) All as per item No. 31 but for One light point controlled by one 5/6 amps one way switch complete all as specified and as directed.
(b) All as per item No. 31 but for One ceiling fan/Exhaust fan point controlled by one 5/6 amps one way switch complete all as specified and as directed.
(d) All as per item No. 31 but for One Socket outlet, three/five pin, 5 Amp, independent controlled by one 5/6 amps one way switch or switch/socket combination 5 amps, 5 pin complete all as specified and as directed.
(f) All as per item No. 31 but for one light point conrolled by 2 Nos, 2 way switches 5/6 Amps complete all as specified and as directed.
Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 2.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No. with and including heavy duty non metalic rigid PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories),including modular GI flush box of suitable size with inner and outer white plastic plate (same make of approved switch and socket) including on run of PVC insulated multi-stranded copper conductor 2.5 Sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed at site for the one 3/5 pin 15/16 amps socket outlet independent board:- (NOTE: Switch and socket to be measured and paid for separately)
Modular switch one way 6 A, 1 module 230 volts 50 Hz ISI Marked complete all as specified and as directed.Make "Crabtree Athena/Legrand Myrius/Anchor Roma" or equivalent make mentioned in the list of manufacturers.
Modular switch two way 6 A, 1 module 230 volts 50 Hz ISI Marked complete all as specified and as directed.Make "Crabtree Athena/Legrand Myrius/Anchor Roma" or equivalent make mentioned in the list of manufacturers.
Modular switch one way 16 A, 1 module 230 volts 50 Hz ISI Marked complete all as specified and as directed.Make "Crabtree Athena/Legrand Myrius/Anchor Roma" or equivalent make mentioned in the list of manufacturers.
Socket modular 6A, 2/3 pin combined, 2 module, AC, 230V, ISI Marked complete all as specified and as directed. Make "Crabtree Athena/Legrand Myrius/Anchor Roma" or equivalent make mentioned in the list of manufacturers.
Socket modular 16A, 2/3 pin combined, 2 module, AC, 230V, ISI Marked complete all as specified and as directed. Make "Crabtree Athena/Legrand Myrius/Anchor Roma" or equivalent make mentioned in the list of manufacturers.
Ceiling fan 5 speed regulator,60 W, 2 module 230 volts 50 Hz ISI Marked complete all as specified and as directed.Make "Crabtree Athena/Legrand Myrius/Anchor Roma" or equivalent make mentioned in the list of manufacturers.
Ceiling fan, Copper wound having serving value ≥4.50 as per IS 374:2019, complete with down rod, canopy, mounting clamp etc. AC, 230V, 1200mm Sweep without regulator including 0.50 Sqmm 3 core flexible Copper cable from fan connector to ceiling rose complete all as specified and as directed. Note:-Ceiling fan shall be fixed with suitable length of down rod as per site requirement to maintain standard height and rate shall deemed to be included in the rate quiote. Make:- Crompton/Usha/Khaitan or equivalent make mentioned in the list of manufacturers.
Exhaust fan 250 mm sweep 230 Volts AC 50 Hz PVC body with copper wound having Energy Efficient model including electrical connection complete all as specified and as directed. Make:- Crompton Model Brisk Air or equivaleny in Usha/Almonard or equivalent make mentioned in the list of manufacturers.
LED Tube light 1X20 Watt 4' universal battern type with and including connecting 3 core 1sqmm PVC insulated multistranded copper conductor's sleeve color matching to fitting and connecting up complete all as specified and as directed at site of Make/Model:- (a) Fitting: Crompton Cat Part No DIJB12LT8 ECO (b) Lamp: Crompton Cat Part No LT8-20-865-(2) ULTRON or equivalent manufacturers from list of manufacturers
LED Tube light 1X10 Watt 2' with and including connecting 3 core 1sqmm PVC insulated multistranded copper conductor's sleeve color matching to fitting and connecting up complete all as specified and as directed at site of Make/Model:- (a) Fitting: Crompton Cat Part No DMLN1LT8-8 UNILITE (b) Lamp: Crompton Cat Part No LT8-8-865-2 ULTRON or equivalent manufacturers from list of manufacturers
Building security light new generation energy saving and environmental friendly long life LED street light 25W made of pressure die cast alluminium housing with hogh power LED as lighting source and lens embded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK 07 complete with and including wall mounted bracket fabricated out of 40mm GI pipe light grade bend to shape1.5 mtr long and two nos wall mounting clamps using 25x4mm thick MS strip bend to shape and welded with pipe to form solid structure and one run of 3 core 1.0 sqmm PVC of size 25mm dia insulated multistranded copper cunductor wire conecting pvc terminal to fitting complete all as specified and as directed. (Make Crompton Model No LSTS-25-CDL-M ASTRA NEO) or equivalent in Philips/Wipro or equivalent manufacturers from list of manufacturers
Bulk head fitting outdoor type including 10 W LED bulb complete all as specified and as directed. Make Crompton (Model-LBHP-10-CDL) or equivalent manufacturers from list of manufacturers.
MCCB DB VTPN 4 way with metal double door 415 Volts with provision for RCBO as incomer and SP/TP MCBs as out going with IP 43 protection, door earthing, isolated neutral bar, mechanical impact strength 1K 09 including cement spill protector complete all as specified and as directed. Make Legrand Cat No 507725 or equivalent in Schneider/L&T or equivalent manufacturers from list of manufacturers.
Sheet metal enclosure distribution board MCB DB SPN 8 way with metal double door 240 Volts with IP-43 protection including door earthing complete all as specified and as directed.Make Legrand Cat No 507611 or equivalent manufacturers from list of manufacturers.
Sheet metal enclosure distribution board MCB DB SPN 12 way with metal double door 240 Volts with IP-43 protection including door earthing complete all as specified and as directed.Make Legrand Cat No 507612 or equivalent manufacturers from list of manufacturers.
Metal DP enclosure suitable for MCB 1K 08 ,as per IEC61439-3 complete all as specified and as directed.Make Legrand Cat No 507791 or equivalent in Schneider/L&T or equivalent manufacturers from list of manufacturers.
MCB SPN 10-32 Amps 10 kA with characteristic "B/C" curve complete all as specified and as directed. Make Legrand Cat No 408609 to 408617 or equivalent manufacturers from list of manufacturers.
RCBO 32 Amps DP, 240V, AC type 30mA complete all as specified and as directed. Make Legrand Cat No 411395 or equivalent manufacturers from list of manufacturers.
RCBO 25 Amps DP, 240V, AC type 30mA complete all as specified and as directed. Make Legrand Cat No 411394 or equivalent manufacturers from list of manufacturers.
RCBO 32 Amps 4P, 415V, AC type 30mA complete all as specified and as directed. Make Legrand Cat No 411189 or equivalent manufacturers from list of manufacturers.
MCB SP 06-32 Amps 10 kA with characteristic "B/C" Curve conforming to IS/IEC 60898 complete all as specified and as directed. Make Legrand Cat No 408587or 408595 equivalent manufacturers from list of manufacturers.
Submain wiring with 2 runs of 6 Sqmm PVC insulated unsheathed copper conductor multistranded FRLS cable drawn in and including heavy duty PVC conduit and its accessories laid in concealed in wall/roof/floor etc including one run of 6 Sqmm multi stranded copper conductor cable as earth continuity wire complete all as specified and as directed. (Note: Three runs of 6 sqmm wire and one run of PVC concealed conduit shall be measured as one run only.)
Earthing complete with galvanised iron earth plate electrode of size 600mm x600mmx6.0 mm thick burried directly under ground vertically in a pit of depth not less than 2.25 Metre below ground level with top edge of the earth plate at a depth not less than 1.5 m below ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected by using galvanised iron strip 25 x 4mm, by means of bolts, nuts, check nuts and washeres made out of GI and earth strip protected by GI protection pipe light grade 40 mm dia connected to main earth strip control board and GI pipe medium grade 20mm bore for watering,funnel with wire mesh . PCC earth chamber pit made in PCC 1:3:6 type C1 (using 20mm graded stone aggregate),40mm thick precast RCC M-25(design mix)cover reinforced with 8mm dia TMT bars@10cm c/c on both sides and handle ,excavation and earth work in any type of soil and removal upto 50m complete all as specified and shown in electric plate No.03 of SSR Part-I(2009),connecting to earth test point including necessary form work complete including necessary test on completion all as specified and as directed.
INTERNAL WATER SUPPLY:- Stop cock angular brass, chromium plated 15mm bore with wall flange complete all as specified and as directed. Make Jaquar Cat part No CQT-23059 or equivalent manufacturers from list of manufacturers.
Bib cock, brass, chromium plated 15mm bore with wall flange complete all as specified and as directed. Make Jaquar Cat part No CQT-23047 or equivalent manufacturers from list of manufacturers.
Health faucet/ hand shower with 1.0m long and easy flexible tube in chrome finish with wall hook and NRV (Back flow preventer) complete all as specified and as directed.Make Jaquar cat part No ALD579 or equivalent manufacturers from list of manufacturers.
Over head shower rose 100mm dia round shape single flow ABS body chrome plated with grey face plate and Rubit cleaning system alongwith shower arm casted 120mm long heavy body round shape for wall mounted shower with wall flange complete all as specified and as directed.Make Jaquar cat part No OHS1989 and SHA-487 or equivalent manufacturers from list of manufacturers.
Stop cock long body brass, chromium plated combination of exposed part kit of concealed stop cock with fitting sleave, operating knob, adjustable wall flange and regular body concealed stop cock suitable for 15mm pipe line with protection cap complete all as specified and as directed.Make Jaquar cat part No CQT-23083K and ALD083 or equivalent make mentioned from list of manufacturers.
EXTERNAL ELECTRIC SUPPLY:- Riddled soil as earth cushioning to UG cable by using IS sieve to separate the composite particle/ roots etc and refilling/ spread in all trenches as cushioning and rammed down to form a solid bed complete all as specified and as directed.Note:-1.Punned thickness shall be measured and paid seperately.2.Excavated approved soil shall be riddled by using sieve to seperate composite particles etc as per IS.
Supply, lay and testing cable XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 2 core 16 sqmm complete all as specified and as directed.
Supply, lay and testing cable XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 4 core 25 sqmm complete all as specified and as directed.
Supply, lay and testing cable XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 2 core 6 sqmm (for street lights) complete all as specified and as directed.
Supply, lay and testing cable XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 4 core 16 sqmm (for street lights) complete all as specified and as directed.
Modification of existing LT panel by providing of MCB, TPN, 32A ,415 V, 10 KA suitable for taking tapping point to connect 4 x 25 sqmm cable complete at sub stn (WT Nos.7,8,9,10 &11) complete all as specified and directed.
Junction box IP 65 made out of polycarbonate for loop in/out all fixing arrangment on pole with one MCB 32A, SPN 10KA, for 2 Core 16 sqmm cable.(WT Nos.1,2,3,4,5,6&13) complete all as specified and directed.Make.Hensel CAT No.KF 0600B or or equivalent manufacturers from list of manufacturers.
Junction box IP 65 made out of polycarbonate for loop in/out all fixing aarangment on pole with one MCB 32A, TPN 10KA for 4 core 25 sqmm (WT No.12) complete all as specified and directed.Make.Hensel CAT No.KF 2500B or or equivalent manufacturers from list of manufacturers.
Supply, test and commissioning of out door type DB suitable for 415V 3 phase 4 wire 50 Hz non metallic kiosk including following switch gear and control gear enclosed in a modular /combinable panel enclosure made out of polycarbonate with IP 65 protection.(WT Nos.10,11&12) complete all as specified and as directed. Incoming MCCB FP,32A 415V, 16KA with breaking capacity 10 KA, O/C and E/F protection - 01 No Bus Bar TP&N 100 Amps, Aluminium bus bar E 91 grade, 1100V, grade duly covered with heat shrinkable, sleeves colour coded duly fixed on moduled brackets - 01 Set Outgoing MCB 32A SPN, 415V, 50Hz with breaking capacity 10KA - 02 No (01-Watch Tower,01-spare) MCB TPN, 415V, 50 Hz, 16A ,10 KA, - 01 No(01- street light) timer switch 415 V three phase 25A with contactor 01 No .
Supply, test and commissioning of out door type DB suitable for 415V 3 phase 4 wire 50 Hz non metallic kiosk including following switch gear and control gear enclosed in modular /combinable panel enclosure made out of polycarbonate with IP 65 protection.(WT No.9) complete all as specified and as directed. Incoming MCCB FP 32A, 415V, 16KA with breaking capacity 16 KA, O/C and E/F protection - 01 No Bus Bar TP&N 100 Amps, Aluminium bus bar E 91 grade, 1100V, grade duly covered with heat shrinkable, sleeves colour coded duly fixed on moduled brackets - 01 Set Outgoing MCB 32A SPN, 415V, 50Hz with breaking capacity 10KA - 02 No (01-Watch Tower,01-spare) MCB, SPN, 250V, 50 Hz, 16A ,10 KA, - 01 No(01- Pump)
Steel tubular swaged poles Type 410SP-22 (8.5 Metre long) with CI base plate and finial tapper plug, bolts, nuts and washers and single swan neck, including 3 coats of bitumen paint internally complete and externally for the portion embedded in concrete and two coats of aluminium paint over a coat of red oxide primer to the balance portion of external surface complete all as specified and as directed. Note : Excavation and PCC shall be measured and paid seperately under relevent item of schedule "A" foundation and coping.
36W LED street light fitting made up of pressure die cast housing with with toughened glass and high power LEDs with option of secondary optic with IP 65 protection complete all as specified and as directed.Make: CROMPTON model: Freedom NEO +LSTS-36-CDL M or equivalent make from list of manufacturers.
Junction box made out of polycarbonate for loop in/ out with all fixing arrangement on pole with one MCB SP 6A for LED light including 10 Metre 1.5 sqmm 3 core flexible cable complete all as specified and as directed.Make:Hensel Cat No.DK 2525G.
Earthing complete with galvanised steel earth plate electrode of size 600mm x600mmx6.0 mm thick burried directly under ground vertically to a depth not less than 2.25 Metre below ground level with top edge of the plate at a depth not less than 1.5 m below ground level connected to and including galvanised iron strip 32 x 6mm, by means of bolts, nuts, check nuts and washers made out of GI including protection pipe GI light grade 40 mm size and watering pipe 20 mm dia GI medium grade all as shown on plate No 3 of SSR Part-I, connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded stone aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC M-25 (design mix) using 20mm graded stone aggregates), with 8mm TMT bars @ 140mm c/c in both ways, including necessary form work complete including necessry test on completion all as specified and as directed.
All as per item No.78 above but 4mm dia GI wire as earth lead complete all as specified and as directed.
Road/Path/Culvert:- Stainless steel( Grade- 316L)railing made of hollow tubes, channels,plates etc, including welding, grinding, buffing, polishing and curvature (whereever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary acessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement,all as specified and as directed
SEWAGE DISPOSAL:- 163mm dia DWCPE Sewer pipes, laid and jointed complete with collars complete all as specified and as directed.
EXTERNAL WATER SUPPLY:- Cutting existing CI tubing 80 mm dia for alternations or additions 80x80x80 mm CI Tee with necessary bush reducer, CI collar for tapping including necessary excavation and making good the surface complete all as specified and as directed.
Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed of dia 25 mm complete all as specified and as directed.
Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed of dia 40 mm complete all as specified and as directed.
Construction of brick masonry Valve Chambers of internal size 0.60 x 0.60 x0.60 m including PCC in foundation 1:5:10 type E2,10cm thick ,rendering cement plaster internally 15mm thick and with cement mortar 1:4, PCC 1:3:6 type C1 using 20mm graded aggregate for coping 10cm thick height,6mm thick MS plate cover with locking arrangement and angle frame of size 80x50x6 mm including painting to plate cover with epoxy paint over one coat of epoxy primer including necessary excavation and earth work complete all as specified and as directed.
Supply and install complete for Monoblock pumping sets, cenrifugal, electric driven for domestic purpose 0.5 HP inclusive PCC foundation complete all as specified and as directed. Make:-Kirloskar pump model KDS0510 or equivalent make mentioned in the list of manufacturers.
Supply and install complete for Monoblock pumping sets, centrifugal, electric driven 2 HP inclusive of starter and PCC foundation complete all as specified and as directed. Make:-Kirloskar pump model KDS-220+ or equivalent make mentioned in the list of manufacturers.
Rotational moulded polyethylene water storage of capacity 2000 litres tanks(Cyclindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and as directed.
TREE CUTTING:- Felling of tree exc.30cm and n exc.100 cm girth including cutting of trunk and branches and stacking of serviceable material and disposal of unserviceable material to a distance n exc.50m and clearing site etc. complete all as specified and as directed.
Felling of tree exc.100cm and n exc.150 cm girth including cutting of trunk and branches and stacking of serviceable material and disposal of unserviceable material to a distance n exc.50m and clearing site etc complete all as specified and as directed.
Felling of tree exc.150cm and n exc.200 cm girth including cutting of trunk and branches and stacking of serviceable material and disposal of unserviceable material to a distance n vexc.50m and clearing site etc complete all as specified and as directed..
FUTURE ONE FACILITY MANAGEMENT
SB CONSTRUCTIONS & TRAVELS
K P DIVAKARAN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid