PR NO : 225484 TENDER ID: 554 / 25-26
Item Code No. Description of Work Unit Qty. Total value
HT TAPPING FROM THE EXISTING POLE INCLUDING FIXING OF CROSS ARMS,
CLAMPS ANTI-CLIMBING DEVICES, DANGER BOARD,INSULATORS, ETC,
1 9901000001 COMPLETE AND PAINTING OF FABRICATED MATERIALS AND NUMBERING Number 481 20
COMPLETE WITH COST OF PAINTS AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND EARTHING
ERECTION OF PSC POLES OF 8 *200 KG INCLUDING EXCAVATION OF PIT AND
REFILLING OF EARTH, FIXING OF CROSS ARMS, TOP FITTING CLAMPS ANTI-
CLIMBING DEVICES, INSULATORS ETC. COMPLETE AND PAINTING OF
2 9902010001 FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH COST Number 1163 20
OF PAINTS AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF
GUY SET AND EARTHING
ERECTION STEEL POLES OF 8 TO 9 & 11 METERS INCLUDING EXCAVATION OF
PIT AND REFILLING OF EARTH, FIXING OF CROSS ARMS, TOP FITTING CLAMPS,
ANTICLIMBING DEVICES DANGER BOARD, INSULATORS, ETC. COMPLETE AND
PAINTING OF STEEL POLE, FABRICATED MATERIALS USED ON ON THE POLE
AND NUMBERING WITH COST OF PAINT AS PER STANDARD SPECIFICATION
BUT EXCLUDING ERECTION OF GUT SET AND EARTHING.
ERECTION STEEL POLES OF 13 METERS FOR RAILWAY CROSSING ON
BG/MG/NG/LINE FOR 0.400/11/22KV OVERHEAD LINE I.E. INCLUDING
EXCAVATION OF PIT AND REFILLING OF EARTH, FIXING OF CROSS ARMS, TOP
4 9902010005 FITTING CLAMPS, ANTICLIMBING DEVICES DANGER BOARD, INSULATORS, ETC. Number 2234 20
COMPLETE AND PAINTING OF STEEL POLES, FABRICATED MATERIALS USED
ON THE POLES AND NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND EARTHING.
5 9902010006 ERECTION OF SUPPORT POLE - PSC Number 735 10
6 9902010007 ERECTION OF SUPPORT POLE - RSJ Number 735 10
ERECTION OF DOUBLE POLE STRUCTURE OF 8 METERS PSC
POLE INCLUDING EXCAVATION OF PITS & REFILLING OF EARTH, FIXING OF CHANNELS,
SUPPORTING ANGLES , CLAMPS, ANTI-CLIMBING DEVICES DANGER BOARDS, INSULATORS, ETC.,
COMPLETE AND PAINTING OF POLES FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINTS AS PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SETS AND EARTHING. ( W/O AB SWITCH ).
ERECTION OF DOUBLE POLE STRUCTURE OF 8 TO 9 METERS STEEL
POLE INCLUDING EXCAVATION OF PITS & REFILLING OF EARTH, FIXING OF CHANNELS,
SUPPORTING ANGLES , CLAMPS, ANTI-CLIMBING DEVICES DANGER BOARDS, INSULATORS, ETC.,
COMPLETE AND PAINTING OF POLES FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINTS AS PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SETS AND EARTHING. ( W/O AB SWITCH ).
ERECTION OF DOUBLE POLE STRACTURE WITH MOUNTING OF AB SWITCH, DO
FUSES OF 8 METERS, 200 KG PSC POLES INCLUDING EXCA-VATION OF PITS AND
REFILLING OF EARTH, FIXING OF CHANNELS,SUPPORTING ANGLES CLAMPS, ANTI-CLIMBING
9 9902020006 DEVICES DANGER BOARD, INSULATORS, DO FUSES, ETC., COMPLETE AND PAINTING OF Number 3179 10
FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH COST OF PAINTS AS PER
STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF DOUBLE POLE STRACTURE FOR CTPT INSTALLATION WITH
MOUNTING OF AB SWITCH, DO FUSES OF 8 METERS, 200 KG PSC POLES INCLUDING EXCA-
VATION OF PITS AND REFILLING OF EARTH, FIXING OF CHANNELS,SUPPORTING ANGLES
CLAMPS, ANTI-CLIMBING DEVICES DANGER BOARD, INSULATORS, DO FUSES, ETC., COMPLETE
AND PAINTING OF FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH COST
OF PAINTS AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND
D:\E DRIVE\MYP 21.04.2025\Tender\MYP Tender 04.07.2025\Maintenance Work Tender Lalbaug & Manjalpur 554 2025-26\02 OH scedule B Lalbaug & Manjalpur sdn Page
Maintenance, Erection and Dismantaling of HT/LT and Transformer center For LALBAUG & MANJALPUR SUB DIVISION and ANY S/Dn Of CFC Lalbaug
PR NO : 225484 TENDER ID: 554 / 25-26
Item Code No. Description of Work Unit Qty. Total value
ERECTION OF DOUBLE POLE STRACTURE WITH MOUNTING OF
AB SWITCH, DO FUSES, 9 & 11 METERS STEEL POLES INCLUDING EXCAVATION OF
PITS AND REFILING OF EARTH, FIXING OF CHANNELS, SUPPORTING ANGLE CLAMPS, ANTI-
11 9902020010 CLIMBING DEVICES , DANGER BOARDS, INSULATORS, ETC., COMPLETE AND PAINTING OF POLES Number 4171 10
FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF DOUBLE POLE STRACTURE FOR CTPT INSTALLATION WITH
MOUNTING OF AB SWITCH, DO FUSES, 9 & 11 METERS STEEL POLES INCLUDING
EXCAVATION OF PITS AND REFILING OF EARTH, FIXING OF CHANNELS, SUPPORTING ANGLE
CLAMPS, ANTI-CLIMBING DEVICES , DANGER BOARDS, INSULATORS, ETC., COMPLETE AND
PAINTING OF POLES FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH
COST OF PAINT AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND
ERECTION OF SINGLE POLE STRACTURE WITH MOUNTING OF DO FUSES,
TRANSFORMERS, LIGHTENING ARRESTERS, DISTRIBUTION BOX ETC. OF
METERS 200 KG PSC POLES INCLUDING EXCAVATION OF PITS AND REFILING OF EARTH,
CARTING OF TRANSFORMERS FROM STORE TO SITE, FIXING OF CHANNELS SUPPORTING
13 990230016 ANGLES, BRACING CROSS ARMS, CLAMPS ANTI-CLIMBING DEVICE DANGER BOARDS Number 4537 10
CONDUCTOR AND CABLE WIRING ETC., COMPLETE AND PAINTING OF FABRICATED MATERIALS
USED ON THE POLES AND NUMBERING WITH COST OF PAINTS AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF SINGLE POLE STRACTURE WITH MOUNTING OF DO FUSES,
TRANSFORMERS, LIGHTENING ARRESTERS AND WITHOUT DISTRIBUTION BOX
ETC OF 8 METERS 200 KG PSC POLES INCLUDING EXCAVATION OF PITS AND REFILING OF
EARTH, CARTING OF TRANSFORMERS FROM STORE TO SITE, FIXING OF CHANNELS SUPPORTING
14 990230016 ANGLES, BRACING CROSS ARMS, CLAMPS ANTI-CLIMBING DEVICE DANGER BOARDS Number 3313 10
CONDUCTOR AND CABLE WIRING ETC., COMPLETE AND PAINTING OF FABRICATED MATERIALS
USED ON THE POLES AND NUMBERING WITH COST OF PAINTS AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF
AB SWITCH, DO FUSES, 13 METERS STEEL POLES INCLUDING EXCAVATION OF PITS
AND REFILING OF EARTH, FIXING OF CHANNELS, SUPPORTING ANGLE CLAMPS, ANTI-CLIMBING
15 9902020019 DEVICES , DANGER BOARDSINSULATORS,ETC COMPLETE AND PAINTING OF POLES FABRICATED Number 4736 10
MATERIALS USED ON THE POLES AND NUMBERING WITH COST OF PAINTS AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF DOUBLE POLE STRACTURE WITH MOUNTING OF DO FUSES,
TRANSFORMERS, LIGHTENING ARRESTERS, DISTRIBUTION BOX ETC. OF
METERS 200 KG PSC POLES INCLUDING EXCAVATION OF PITS AND REFILING OF EARTH,
CARTING OF TRANSFORMERS, FROM STORE TO SITE FIXING OF CHANNELS SUPPORTING
16 9902030001 ANGLES, BRACING CROSS ARMS, CLAMPS ANTI-CLIMBING DEVICE DANGER BOARDS Number 9074 10
CONDUCTOR AND CABLE WIRING ETC.,COMPLETE AND PAINTING OF FABRICATED MATERIALS
USED ON THE POLES AND NUMBERING WITH COST OF PAINTS AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRACTURE WITH MOUNTING OF DO FUSES,
TRANSFORMERS, LIGHTENING ARRESTERS & WITHOUT DISTRIBUTION BOX ETC
OF 8 METERS 200 KG PSC POLES INCLUDING EXCAVATION OF PITS AND REFILING OF
EARTH, CARTING OF TRANSFORMERS, FROM STORE TO SITE FIXING OF CHANNELS SUPPORTING
17 9902030001 ANGLES, BRACING CROSS ARMS, CLAMPS ANTI-CLIMBING DEVICE DANGER BOARDS Number 7850 10
CONDUCTOR AND CABLE WIRING ETC.,COMPLETE AND PAINTING OF FABRICATED MATERIALS
USED ON THE POLES AND NUMBERING WITH COST OF PAINTS AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND EARTHING.
D:\E DRIVE\MYP 21.04.2025\Tender\MYP Tender 04.07.2025\Maintenance Work Tender Lalbaug & Manjalpur 554 2025-26\02 OH scedule B Lalbaug & Manjalpur sdn Page
Maintenance, Erection and Dismantaling of HT/LT and Transformer center For LALBAUG & MANJALPUR SUB DIVISION and ANY S/Dn Of CFC Lalbaug
PR NO : 225484 TENDER ID: 554 / 25-26
Item Code No. Description of Work Unit Qty. Total value
ERECTION OF SINGLE POLE STRACTURE WITH MOUNTING OF A B SWITCH, DO
FUSE, TRANSFORMERS, LIGHTENING ARRESTERS, DISTRIBUTION BOX 8 TO 9 &
11 METERS STEEL POLES INCLUDING EXCAVATION OF PITS AND REFILING OF
EARTH,CARTING OF TRANSFORMERS FROM STORE TO SITE,FIXING OF CHANNELS, SUPPORTING
ANGLES, BRACING, CROSS ARMS,CLAMPS, ANTI CLIMBING, DEVICES, DANGER BOARDS,
CONDUCTOR AND CABLE WIRING ETC.COMPLETE AND PAINTING OF POLES FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF SINGLE POLE STRACTURE WITH MOUNTING OF A B SWITCH, DO
FUSE, TRANSFORMERS, LIGHTENING ARRESTERS & WITHOUT DISTRIBUTION
BOX 8 TO 9 & 11 METERS STEEL POLES INCLUDING EXCAVATION OF PITS AND REFILING
OF EARTH,CARTING OF TRANSFORMERS FROM STORE TO SITE,FIXING OF CHANNELS,
SUPPORTING ANGLES, BRACING, CROSS ARMS,CLAMPS, ANTI CLIMBING, DEVICES, DANGER
BOARDS, CONDUCTOR AND CABLE WIRING ETC.COMPLETE AND PAINTING OF POLES
FABRICATED MATERIALS USED ON THE POLES AND NUMBERING AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF A B SWITCH, DO
FUSE, TRANSFORMERS, LIGHTENING ARRESTERS, DISTRIBUTION BOX 8 TO
& 11 METERS STEEL POLES INCLUDING EXCAVATION OF PITS AND REFILLING OF
EARTH,CARTING OF TRANSFORMERS FROM STORE TO SITE,FIXING OF CHANNELS, SUPPORTING
ANGLES, BRACING, CROSS ARMS,CLAMPS, ANTI CLIMBING, DEVICES, DANGER BOARDS,
CONDUCTOR AND CABLE WIRING ETC.COMPLETE AND PAINTING OF POLES FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF A B SWITCH, DO
FUSE, TRANSFORMERS, LIGHTENING ARRESTERS & WITHOUT DISTRIBUTION
BOX 8 TO 9 & 11 METERS STEEL POLES INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH,CARTING OF TRANSFORMERS FROM STORE TO SITE,FIXING OF CHANNELS,
SUPPORTING ANGLES, BRACING, CROSS ARMS,CLAMPS, ANTI CLIMBING, DEVICES, DANGER
BOARDS, CONDUCTOR AND CABLE WIRING ETC.COMPLETE AND PAINTING OF POLES
FABRICATED MATERIALS USED ON THE POLES AND NUMBERING AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF GUY SETS INCLUDING EXCAVATION OF PITS & REFILING OF
EARTH, AS PER STANDARD SPECIFICATION WITH STAY CLAMPS STAY WIRES,
22 9902040001 ANCHOR ROD, TURN BUCKLE, EYE BOLT, GUY INSULATOR, CEMENT Number 561 10
CONCRETE BLOCK, ETC., BUT EXCLUDING CONCRETING.
CONCRETING/ MUFFING OF POLES GUY ETC., INCLUDING COST OF
23 9905010001 METAL (1:2:4) AND WATER ETC., AS PER C.C.M-20 GRADE STANDARD CMT 5995 20
SPECIFICATION .
ERECTION COIL TYPE EARTHING INCLUDING COST OF COAL & SALT, ETC.BUT
WITHOUT COST OF G I WIRE & COIL. AS PER STANDARD SPECIFICATION 10 KG
SALT + 10KG COAL.GI WIRE TO BE PASSED THROUGH PVC RIGID PIPE FOR
SUITABLE LENGTH AS PROVIDED BY THE S/DN ENGR. IN CHARGE
SRTINGING OF 34MM2 ,55MM2,AAA CONDUCTOR, FOR 11 KV & L.T. LINE ONE COND
INCLUDING FIXING OF INSULATORS, BINDING, JUMPERING, ETC. PER KM
SRTINGING OF 100 MM2, ACSR/DOG CONDUCTOR, FOR 11 KV & L.T.LINES ONE COND
INCLUDING FIXING OF INSULATORS, BINDING, JUMPERING, ETC. PER KM
D:\E DRIVE\MYP 21.04.2025\Tender\MYP Tender 04.07.2025\Maintenance Work Tender Lalbaug & Manjalpur 554 2025-26\02 OH scedule B Lalbaug & Manjalpur sdn Page
Maintenance, Erection and Dismantaling of HT/LT and Transformer center For LALBAUG & MANJALPUR SUB DIVISION and ANY S/Dn Of CFC Lalbaug
PR NO : 225484 TENDER ID: 554 / 25-26
Item Code No. Description of Work Unit Qty. Total value
THE WORK OF STRINGING OF ABC OF FOLLOWING SIZES INCLUDING FITTING
OF ALL ACCESSRIES I.E. SPECIAL DESIGN SUSPENSION / TENASION CLAMP,
FIXING OF CROSS ARM, L.T. SHACKLE INSULATOR , ETC. FOR FIXING OF
MESSAGER WIRE COMPLETE, AS REQUIRED & DIRECTED BY ENGINEER-IN-
CHARGE A: 3 X 50MM2+16MM2+1X 35MM2 B: 3 X 50MM2+16MM2+1X 25MM2
THE WORK OF STRINGING OF ABC OF FOLLOWING SIZES INCLUDING FITTING
OF ALL ACCESSRIES I.E. SPECIAL DESIGN SUSPENSION / TENASION CLAMP,
FIXING OF CROSS ARM, L.T. SHACKLE INSULATOR , ETC. FOR FIXING OF
MESSAGER WIRE COMPLETE, AS REQUIRED & DIRECTED BY ENGINEER-IN-
CHARGE A : 1 X 35MM2 + 1 X 25MM2
THE WORK OF STRINGING OF 11 KV ABC OF FOLLOWING SIZES IN URBAN
AREA INCLUDING FITTING OF ALL ACCESSRIES I.E. SPECIAL DESIGN SUSPENSION / TENASION
29 9903000007 CLAMP, FIXING OF CROSS ARM, BINDING TO PIN INSULATOR,PREPARING SHCKLE POINT KM 45107 10
JUMPERS ETC AS REQUIRED & DIRECTED BY ENGINEER-IN-CHARGE A: 3 X95MM2+1X
THE WORK OF STRINGING OF 11 KV ABC OF FOLLOWING SIZES IN RURAL
AREA INCLUDING FITTING OF ALL ACCESSRIES I.E. SPECIAL DESIGN SUSPENSION / TENASION
30 9903000007 CLAMP, FIXING OF CROSS ARM, BINDING TO PIN INSULATOR,PREPARING SHCKLE POINT KM 48117 10
JUMPERS ETC AS REQUIRED & DIRECTED BY ENGINEER-IN-CHARGE A:
PROVIDING GUARDING TO HT LINE ON ROAD/RAIL CROSSING
PROVIDING GUARDING OF LT LINE ON ROAD/RAIL CROSSING
33 9901000002 LT LINE TAPPING SINGLE PHASE. Number 51 10
34 9901000003 LT LINE TAPPING THREE PHASE. Number 93 10
LAYING OF OVER HEAD LT CABLE FOR ROAD CROSSING HT LINE CROSSING
AND TELEPHONE LINE CROSSING ETC (PER SPAN)
Dismentalling of all size (8,9,11,13…mtrs.) of RSJ (girder) Poles including dimentalling of
36 9907000006 relevant channels, cross arms insulators, jumpers, binding, earthing etc. INCLUDING Number 974.5 10
Dismentalling of PSC Poles including dimentalling of relevant channels, cross arms
insulators, jumpers, binding, earthing etc. INCLUDING Cr. IN STORE
38 9907000009 Dismentalling of conductor from line. INCLUDING Cr.IN STORE KM 1055.5 10
39 9907000012 Dismentalling of 8 MTR PSC D.P.Structure. INCLUDING Cr. IN STORE Number 1322 10
Dismentalling of 8 MTR PSC POLE Transformer Structure up to 100 kva. INCLUDING
41 9907000012 Dismentalling of 8 TO 9 MTR STEEL POLE D.P.Structure. INCLUDING Cr. IN STORE Number 1910.5 10
Dismentling OF 11 KV ABC from line. INCLUDING Cr. IN STORE IN RURAL AREA
INCLUDING REMOVING OF ALL ACCESSRIES
Dismentalling of A.B.Cable from line. INCLUDING Cr. IN STORE OF FOLLOWING
SIZES:A: 3 X 50MM2+16MM2+1X 35MM2 B: 3 X 35MM2+16MM2+1X 25MM2
Dismentalling of A.B.Cable from line. INCLUDING Cr. IN STORE OF FOLLOWING
INSTALLATION OF ENERGY METER & MMB/SMC BOX WITH ELECTRICAL WIRING
PROVIDING SINGLE PHASE SERVICE CONNECTION WITH PVC 2.5/4.0 MM2 TWIN
CORECABLE FROM TERMINAL POLE TO METERING POINT INCLUDING FIXING
OFMETER WITH METER EARTHING COMPLETE WORK AS PER STANDARD
SPECIFICATION BUT EXCLUDING COST OF MATERIALS.
PROVIDING THREE PHASE FOUR WIRE SERVICE CONNECTION WITH PVC
4MM2/10MM2 FOUR CORE CABLE FROM TERMINAL POLE TO METERING POINT
INCLUDING FIXING OF METER WITH METER EARTHING COMPLETE WORK AS
PER STANDARD SPECIFICATION BUT EXCLUDING COST OF MATERIALS
D:\E DRIVE\MYP 21.04.2025\Tender\MYP Tender 04.07.2025\Maintenance Work Tender Lalbaug & Manjalpur 554 2025-26\02 OH scedule B Lalbaug & Manjalpur sdn Page
Maintenance, Erection and Dismantaling of HT/LT and Transformer center For LALBAUG & MANJALPUR SUB DIVISION and ANY S/Dn Of CFC Lalbaug
PR NO : 225484 TENDER ID: 554 / 25-26
Item Code No. Description of Work Unit Qty. Total value
48 9909000001 CARTING OF PSC POLE AT DESTINATION(ABOVE 5 KM) Number 378 10
49 9909000006 CARTING OF RSJ POLE AT DESTINATION(ABOVE 5 KM) Number 536 10
REPLACEMENT OF FAIL TRANSFORMER & AUGMENTATION/DEAUGMENTATION
50 9908000049 OF TRANSFORMER(ANY CAPACITY) INCLUDING TRANSPORTATION & CREDIT Number 1500 10
OF OLD TRANSFORMER AT S/DN STORE
51 1501000024 M.S. Bolts & Nuts 65x16mm ( 2.5 X 5/8 INCH) KG 108.56 10
52 1501000031 M.S. Bolts & Nuts 180x16mm ( 7 X 5/8 INCH) KG 108.56 10
53 1501000038 M.S.Bolts & Nuts 300x16mm (12 X 5/8 INCH) KG 108.56 10
Proving & Fixing of HEAT SHRINKABLE TYPE CABLE JOINTING KIT SUITABLE FOR
11 KV 1C X 95 SQ MM AB CABLE FOR OUT DOOR TERMINATION APPLICATION
Proving & Fixing of HEAT SHRINKABLE TYPE CABLE JOINTING KIT SUITABLE FOR
11 KV 1C X 70 SQ MM AB CABLE FOR OUT DOOR TERMINATION APPLICATION
Installation of earhing pits as per drawing attached here with by providing 100 mm inner
dia-meter cast iron pipe of 13 mm thicknes & 3000 mm length. Work includes fabrication
& fixing of GI strips for earthing connections as per drawing attached. Excavated earth-
pit should be filled by mixture of coal / Charcoal, salt & sand up to top. Further this
includes provid ind brick masonary chambr of size 450mm x 450mm & depth up to
mm as per instruction of Engineer in charge including light type CI cover & applying
56 9918000135 mm thick cement plasterin 1:3 inside &to all exposed faces up to 3oo mm below, Number 23966 1
foundation level, curring etc. complete. Extra earth should be removed away from the
site S/S or refilling earthing pits if required. All required material for this job such as CI
pipe, cover with frame, salt, charcoal, sand cement gravel, bricks etc. to be supplied by
the contractor. Required bolts, nuts, washers, numberplates / painted plates also shall
be arranged by the contractor. Tentative quantity of salt & charcoal shall be 2.50 cu.m.
DRG.NO:-GETCO/E/4s-025/P-011,Revision-3 is attached
57 9911000071 PETROLING HT/LT LINE- PER POLE PER POLE 4 10
58 9911000190 RE-JUMPERING OF HT/LT LINE FOR SHACKLE POLE PER POLE 98 10
REPLACEMENT OF POLE MOUNTED 1PH / 3PH SERVICE CONNECTION BOX
INCLUDING RECONNECTING ALL CONNECTIONS
60 9911000189 Cutting of Tree branches obstructing HT/LT line on one tree PER TREE 60 10
61 9911000189 Cutting of bigger size of Tree branches / Whole tree obstructing HT/LT line PER 477 10
62 9911000229 PIN BINDING OF 11KV PIN INSULATOR PER POLE 47 10
63 9911000230 PIN BINDING OF LT LINE PIN OR SHACKLE INSULATOR PER POLE 47 10
64 9908000003 REPLACEMENT OF 11 KV DISC INSULATOR Number 171 10
65 9908000166 REPLACEMENT OF LT PIN /SHACKLE INSULATOR Number 37 10
66 9908000001 REPLACEMENT OF V CROSS - ARMS Number 244 10
67 9908000051 REPLACEMENT OF TOP FITTING Number 60 10
68 9908000007 REPLACEMENT OF LT CROSS - ARMS Number 79 9
PROVIDING DO FUSE OR AB SWITCH ON DP (FOR ONE SET) WITH FABRICATION
69 9908000169 & COLOUR CODE JUMPER,INCLUDING PROPER ALIGNMENT OF AB SWITCH Number 856 10
NUMBERING THE POLE WITH PAINT BY PREPARING BACK GROUND OF
REQUIRED HEIGHT SURFACE OF ONE COLOUR AND HAVE LETTERING ( 2" & 3"
70 9911000001 HT ) AS DIRECTED BY IN CHARGE ENGINEER .THE TWO COLOUR SHOULD HAVE Number 60 10
BEEN SLECTED AS TO HAVE CONTRAST FOR PROPER
READABILITY.(REQUIRED COLOUR TO BE PROVIDED BY CONTRACTER)
FIXING OF SMC (1-Ph) AT CONSUMER INSTALLATION ( INCLUDING COST OF
FIXING OF SMC (3-Ph) AT CONSUMER INSTALLATION ( INCLUDING COST OF
73 9908000023 REPLACEMENT OF METER (1 PH) WITH WIRING - Urban Number 58.13 10
74 9908000023 REPLACEMENT OF METER (1 PH) WITH WIRING - Rural Number 85.05 10
75 9911000227 PROVIDING (PAINTING ) CONSUMER No ON SMC/MMB - Rural Number 21.53 10
76 9911000227 PROVIDING (PAINTING ) CONSUMER No ON SMC/MMB - Urban Number 11.842 10
D:\E DRIVE\MYP 21.04.2025\Tender\MYP Tender 04.07.2025\Maintenance Work Tender Lalbaug & Manjalpur 554 2025-26\02 OH scedule B Lalbaug & Manjalpur sdn Page
Maintenance, Erection and Dismantaling of HT/LT and Transformer center For LALBAUG & MANJALPUR SUB DIVISION and ANY S/Dn Of CFC Lalbaug
PR NO : 225484 TENDER ID: 554 / 25-26
Item Code No. Description of Work Unit Qty. Total value
REPLACEMENT OF SINGLE PHASE OLD SERVICE BY NEW SERVICE INCL
77 9908000016 .SHORTFALL REEL INSULATORS, EGG INSULATORS, NAILS, FIXING FASTNERS Number 98 8
78 9902040007 ERECTION/PROVIDING LIGHTENING ARRESTOR Number 123 10
REPAIRING/ADJUSTING TENSION OF EXISTING GUY/STAY SET INCLUDING
PROVIDING/REPLACEMENT OF STAY INSULATOR
REPLACEMENT OF OLD DISTRIBUTION BOX 200 KVA & ABOVE WITH MAKING
ALL CONNECTIONS CRIMPING OF LUGS,NEUTRAL ETC
REPLACEMENT OF OLD DISTRIBUTION BOX UP TO 100 KVA & ABOVE WITH
MAKING ALL CONNECTIONS CRIMPING OF LUGS,NEUTRAL ETC
82 9911000054 PROVIDING LINE SPACER BETWEEN LT LINE CONDUCTOR WITH BINDING Number 37 10
83 9908000050 REFITTING/REPLACEMENT OF LIGHTENING ARRESTORS Number 37 10
84 9911000072 THREAD BURNING OF HT/LT LINE INCLUDING COST OF OIL AND BAMBOO ETC. Number 73 10
85 9911000010 REFIXING OF V CROSS ARM FITTING INPROPER POSITION Number 73 10
86 9911000226 REFIXING OF TOP FITTING INPROPER POSITION Number 49 11
87 9903000004 RESTRINGING OF ACSR/AAC SPAN Per Span 111 10
88 9911000224 RE-STRINGING OF 11KV A.B.CABLE (ALL SIZE) HT ABC ONLY Per Span 330 10
89 9911000225 RE-STRINGING OF DOG CONDUCTOR WITH NEW DOUBLE PIN BINDING Per Span 148 10
MOULDING OF CABLE JOINT FOR XLPE CABLE (STRAIGHT/INDOOR/OUTDOOR)
D:\E DRIVE\MYP 21.04.2025\Tender\MYP Tender 04.07.2025\Maintenance Work Tender Lalbaug & Manjalpur 554 2025-26\02 OH scedule B Lalbaug & Manjalpur sdn Page
Maintenance, Erection and Dismantaling of HT/LT and Transformer center For LALBAUG & MANJALPUR SUB DIVISION and ANY S/Dn Of CFC Lalbaug
PR NO : 225484 TENDER ID: 554 / 25-26
Item Code No. Description of Work Unit Qty. Total value
91 9908000451 Replacement of 11KV PIN insulator by new Pin Insulator /Composite Pin Insulator Number 56 10
92 9908000452 Straightening of tilted PSC/RSJ Pole at pin point Number 284 10
93 9908000453 Straightening of tilted PSC/RSJ Pole at tension point Number 329 10
94 9908000454 Straightening of tilted D.P. Set (PSC / Girder pole) etc with refilling of stones, morum etc. Number 810 10
Laying/Relaying of cable in Cable trench & from ground level to pole structure for
providing outdoor cable joints.
96 9903000009 Unbundaling of all size HT ABC KM 12029 15
97 9903000008 Stringing of all size HT ABC KM 6015 10
TOTAL ESTIMATED AMOUNT Without GST IN RS
TOTAL AMT WITH GST
Bidder‟s offer (+/-) in % [B]
Grand Total [C=A+/-(A*B)
Grand Total [C=A+/-(A*B)
Goods & Service tax [D = C x GST %] (GST Rate :___%) SAC Code:
Grand Total including GST [E=C+D]
Grand Total including GST [E=C+D]
Final offer (in RS.)
Final offer (Rs. In words)
The bidder shall quote FIRM PRICES only. The prices quoted will not be subject to any escalation till completion of work.
The above prices are inclusive of all taxes, levies Duties etc. except Goods & Service tax (GST). GST will be paid extra as applicable from time to time on a given
taxable goods and/or services.
NOTE: Work for this order is for GIDC sdn and ANY SDN of CFC within the jurisdiction of Lalbaug division.
RATE INCLUSIVE/EXCLUSIVE OF GST SHOULD BE CLEARLY MENTIONED IN YOUR QUAOTATION(MENTION IT IN ONLINE
IN SCHDULE ''B'' MENSIONED QUANTIES ARE ESTIMATED. QUANTIIES MAY BE INCREASED OR DECREASED IN EVERY
WORKS. BUT ORDER VALUE WILL NOT BE CHANGED & PAYMENT WILL DONE AS PER ACTUL EXCUSION OF WORKS
In case any joint fails within one year due to poor workmanship,it should be replaced free of cost by you else, the charges for the
same will be deducted from your bill.
For laying of double circuit, both cables should be covered with separate RCC hume pipe of 6"diameter OR Provided HDPE Pipe for
laying 11KV cable. Pipe should be 10mm thickness.
If the work of cable would not be started within six hours from verbal instruction of Engineer-in-charge from sub-division, the penalty
will be charged @ Rs.200/- per occasion.
SIGNATURE OF CONTRACTOR
(With Rubber Stamp & Date)
D:\E DRIVE\MYP 21.04.2025\Tender\MYP Tender 04.07.2025\Maintenance Work Tender Lalbaug & Manjalpur 554 2025-26\02 OH scedule B Lalbaug & Manjalpur sdn Page
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
01. Tender Notice 554.pdf
02. Schedule-B 554.pdf
03. Scope of work.pdf
04.Terms and Condirions Latest.pdf
05.Conflict of Interest.pdf
06.DECLARATION IN REGARD TO RELATIONSHIP WITH EMPLOYEE.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .