Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹44.5 LAccepted-AOC FLAT NO A 1108 TOWER P 2 ASHIYANA PALM COURT RAJNAGAR EXTENSION GHAZIABAD UP | GHAZIABAD | UTTAR PRADESH | 201001 | L-1 | Accepted-AOC Work awarded | |
| 2 | L-2₹46.6 L+₹2.1 L (4.63%)Rejected-Finance | L-2 | Rejected-Finance Due to higher rate | |
| 3 | L-3₹52.1 L+₹7.6 L (17.1%)Rejected-Finance | L-3 | Rejected-Finance Due to higher rate |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
10 Oct 2022, 11:00 amClosed
Superintending Engineer
Electricity Distribution Circle, Rudrapur
Replacement and repair of damage and rusted pole of 33 KV and 11 KV line under EDSD Rudrapur-I under Electricity Distribution Division, Rudrapur -I.
2022_UPCL3_49725_1
EDC(USN)73/2022-23
Open Tender
Electrical Works
Item Rate
90 days
Rudrapur
Pl. refer tender documents
3 documents required · 3 mandatory
₹2,360
SE EDC Rudrapur
₹90,000
21 Jul 2023
24 Sept 2022
11 Oct 2022
24 Sept 2022
10 Oct 2022
24 Sept 2022
Amount
Annexure-A (LABOUR CHARGES)
Cartage of small material with conductor including Loading /Unloading from store centre at Haldwani/ Rudrapur /Kashipur to work site (Distance upto 70 KM).
Cartage of SP-55 Pole including Loading /Unloading from store centre at Haldwani/Rudrapur/Kashipur to work site (Distance upto 70 KM).
Cartage of PCC Pole 8.5 mtr long including Loading /Unloading from store centre at Haldwani/Rudrapur/ Kashipur to work site (Distance upto 70 KM).
Head load Cartage of SP-55 Pole from road to work site upto 0-1 Km distance including loading/unloading.
Head load Cartage of PCC Pole 8.5 mtr long from road to work site upto 0-1 Km distance including loading/unloading.
Head load Cartage of small material with conductor from road to work site upto 0-1 Km distance including loading/unloading.
Charges of bracking RCC top for errection of pole and stay set with help of power hammer drill including provding all T&P complete.
Charges of Excavation of earth for ST Pole SP-55 pit size 0.9*0.6*1/6 of pole length as per RESSPO Spn. & instruction of Engineer In Charge (0.99x8 cum)
Charges of Excavation of earth for PCC pole 8.5 mtr long pit size 0.9*0.6*1/6 of pole length as per RESSPO Spn. & instruction of Engineer In Charge (0.765x35 cum)
Charges of Erection of Single Pole ST SP-55 including Excavation of earth/hard rcc road with hammer drill and back filling complete work including rebinding of conductors on insulator, as per direction of Engineer in charge.
Charges of Erection of Single PCC Pole 8.5 mtr long including Excavation of earth/hard rcc road with hammer drill and back filling complete work including rebinding of conductors on insulator, as per direction of Engineer in charge.
Charges of Grouting of SP-55 Pole in size 0.45*0.45* 1/6 of pole length by cc in ratio 1:4:8 and proper back filling as per RESPO Spn. & instruction of Engineer In Charge
Charges of straightening of tilted pole after opening of lines and rebinding again as per directon of Engineer in charge.
Charges of repairing of STP pole after welding with help of MS angles providing of welding set and other T&P complete as per directon of Engineer in charge.
Charges of Muffing of new ST SP 55 Poles and existing steel pole with CC 1:2:4 block and 45 cm height from ground level including cost of required material as ballast, cement, sand etc complete in all respect as per direction of work incharge.
Charges of making of CC block arround all size steel pole situated in water logging areas (cc ratio 1:2:4) block size 0.6x0.6x1 mtr height including all material and shultering complete as per direction of work incharge.
Charges of painting of new SP-55 poles and existing SP 55, SP 45, SP 33, 2 coat of primer & 1 coat of al. paint as per norms & direction of Engineer in charge.
Charges of Fabrication of MS channel 100x50 mm /angle 65x65x6 mm (supplied by the department) with cutting, drilling holes and fabrication charges as required by Engineer in charge for proper completion
Charge of Erection of galvanised Earthing rod connecting support with G.I.Wire no.6 S.W.G. as per RESPO specification & as per direction of Engineer in charge.
Charges for replacement of 11 KV/33 KV jumper including providing and fixing of dog to dog pg clamp as per direction of Engineer in charge.
Charges of Erection of stay set 16x1800mm. pit size 0.6x0.9x1.2 Mtr. including excavation of earth as per direction of Engineer in charge.
Charges of Grouting of stay in ratio 1:4:8. (1 cemant:4 graded stone 20mm,8 course sand) including cost of cemant,sand & stone blast back filling soil bolder in pit etc. (0.108 cum each) as per RESPO specification & as per direction of Engineer in charge.
Charges for fixing of stay insulator at existing stay set including opening of stay wire and rebinding, nuzling and tightning as per direction of Engineer in charge.
Annexure-B (SUPPLY ITEMS)
Supply of X-arm clamp for ST pole SP-55.
Supply of X-arm clamp for PCC Pole 8.5 mtr long.
Supply of LT clamp for PCC Pole 8.5 mtr long.
Supply of LT Shakkle insulator.
Supply of F clamp for PCC pole.
Supply of Stay Insulator for new and replacement of existing damage insulator.
Supply of Stay clamp for ST Pole SP 55.
Supply of galvanised earthing rod.
Supply of Stay clamp for PCC Pole.
Supply of Nut and bolt off sizes.
UTTARANCHAL ENTERPRISES
J AND J COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .