Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 CrAccepted-AOC DUMKA ROAD OPPOSITE IRRIGATION COLONY JAMTARA JHARKHAND 815351 | JAMTARA | JHARKHAND | 815351 | ₹2.4 Cr | L1 | Accepted-AOC L-1 |
| 2 | L2₹2.5 Cr+₹11.4 L (4.79%)Rejected-Finance PATHARGAMA GODDA | PATHARGAMA | GODDA | JHARKHAND | ₹2.5 Cr+₹11.4 L (4.79%) | L2 | Rejected-Finance L2 |
| Sl No | Description | Qty | Unit | Madan Lal Bajaj Construction Pvt. Ltd. L1 | M/S S K TEKRIWAL L2 |
|---|---|---|---|---|---|
| 1.00 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 m including all lifts, levelling , ramming the foundation trenches, removing roots of trees, serbs all complete as per approved design,building specification & direction of E/I. | 1,174.97 | CUM | 200 ₹2,34,994.8 | 167 ₹1,96,220.66 Lowest |
| 2.00 | Providing coarse clean local sand in filling in foundation trenches or in plinth including ramming and watering in layer not exceeding 150mm thick with all leads and 1.5M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume) | 23.07 | CUM | 600 ₹13,839.6 Lowest | 648 ₹14,946.77 |
| 3.00 | Providing designation 75B one Brick Flat Soling joints with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I. | 248.44 | SQM | 350 ₹86,952.95 Lowest | 363 ₹90,182.63 |
| 4.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) | 12.33 | CUM | 4,000 ₹49,324 Lowest | 4,127 ₹50,890.04 |
| 5.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) | 174.02 | CUM | 5,000 ₹8,70,110 Lowest | 5,058 ₹8,80,203.28 |
| 6.00 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) | 80.22 | CUM | 5,600 ₹4,49,248.8 Lowest | 5,740 ₹4,60,480.02 |
| 7.00 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) | 23.32 | CUM | 6,500 ₹1,51,612.5 Lowest | 6,691 ₹1,56,067.58 |
| 8.00 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). | 134.95 | CUM | 6,800 ₹9,17,653.2 Lowest | 6,940 ₹9,36,546.06 |
| 9.00 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete | 93.66 | SQM | 300 ₹28,096.5 | 214 ₹20,042.17 Lowest |
| 10.00 | Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts | 310.87 | SQM | 300 ₹93,260.4 Lowest | 512 ₹1,59,164.42 |
Tender Value
₹2.3 Cr
EMD Value
₹4.5 L
Closing Date
30 Dec 2025, 11:00 amClosed
E.E., BCD, Building Division, Dhanbad
E.E., BCD, Building Division, Dhanbad
Construction of Pavilion (G Plus 1) Football Stadium of KFS Ground at Kumardubi, Dhanbad. (Second Call)
2025_BCD_107896_1
06/2025-26/EE/BCD/DHANBAD
Open Tender
Civil Works - Buildings
Works
270 days
Dhanbad
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹4.5 L
26 May 2026
16 Dec 2025
31 Dec 2025
16 Dec 2025
30 Dec 2025
16 Dec 2025
Amount
Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 m including all lifts, levelling , ramming the foundation trenches, removing roots of trees, serbs all complete as per approved design,building specification & direction of E/I.
Providing coarse clean local sand in filling in foundation trenches or in plinth including ramming and watering in layer not exceeding 150mm thick with all leads and 1.5M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume)
Providing designation 75B one Brick Flat Soling joints with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for : Weather shade, Chajjas, corbels etc., including edges
Centering and shuttering including strutting, propping etc. and removal of form for : Stairs, (excluding landings) except spiral-staircases
Providing TMT reinforcement of following dia rods as per approved design and drawing including carriage of M.S. rods of (Straight or in coils) to work site, cutting, bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I.
8 mm dia (30 %of total reinforcement)
10 mm dia (10 %of total reinforcement)
12,16 and 20 mm dia (60%of total reinforcement)
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3mmdia. round headed screws, one lock at the corners. Clamp shall be made of 12mm dia M.S. bar bent to shape as per standard drawing.
Earth filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
Earth filling in foundation trenches and plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M. and lift of 1.5 M all complete as per building specification and direction of E/l (Mode of measurement compacted volume).
Providing designation 75 B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 20 mm nominal size)
Providing designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9" x 4.5" x 3") in C.M. (1:6) in superstructure with approved quality of clean sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing 112mm thick reinforced designation Flyash brickwork in C.M. (1:4) in Superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, cost of materials, racking out joints to 15mm depth, carriage, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.
Extra brick work for each consecutive floor above first floor including watering and scaffolding all compleat as per direction of E/I
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 and including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I
Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I.
Extra for plaster work exteriour surface for each consecutive floor above first floor including cost of scaffolding ect all complete as per directiopn of E/I
Making 6x6mm grooves in plaster surface over walls truely horizontal or verical as specified at regular intervals, at all heights including cleaning, finishing scaffoding and curing with all leads and lifts of water all complete as per building specification and direction of E/l.
Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I. With commercial grade colour Tiles.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and laying Double charged vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less then 0.08% and conforming to IS: 15622/ISO 13006 of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement:4 Coarse sand0, jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with wite cement and matching pigments etc, complete Size of tiles 600 x 600 mm.
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strikeplate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineerin-charge:Profile C Fixing with adjustable lugs with split end tail to each jamb
Supplying, fitting and fixing 35mm thick solid core type non decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes
Supplying, fitting & fixing 35mm thick solid core type non-decorative double leaf flush shutter in doors and windows with black board core blended with high quality phenol formal dehyde synthetic resin both side commercial veneeres of standard makew with oxidised iron fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I.
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.5 mm thick
Providing and fixing Factory made PVC rigid foam sheet 5 mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Supplying, fitting & fixing M.S. Grill made of 20x6mm flat as per approved design and drawing aproperly fabricated with joints continuous fitted, welded and finished smooth, hoisting as per building specification and direction of E/I.
Supplying , fitting and fixing collapsible gate of apporoved size and make properly fabricated with vertical double channels 20x10x2 mm. at 100mm. Centres and braced with M.S flat diagonals 20 x 3 mm,with top and bottom rails of T. iron 40x40x6 mm with 38 mm dia steel pulleys complete with bolts nuts, locking arrangements stoppers, handles, including applying a primer coat of led paint carriage hosting and taxes all complete as per building specification and direction of E/I.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion, Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness
Providing primer one coat of red lead paint ofapproved make over steel surface including preparing the surface after cleaning removing dirt, scales, grease and sand papering, including cost of scaffolding etc. all complete as per building specification direction of E/I.
Providing 2 coats of Synthetic Enamel Paint of approved shade and make over steel surface grills & railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.
Water proofing for old and New Roof Slab :- Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flextble material brush, roller or spray for water proofing coating per manufacturer Specifications with following steps :-(a)surface preparation .-Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing (loose paint / coating, and cement laitance by cleaning with compressed air water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage leakage. On identification of seepage cement grouting to be done with non shrink expanding admixture of Sika India Pvt.L.td.) MYK Schomberg / Dr Fixiti/ Fosroc or equivallent. Providing and reparing of all Corner and joints such as those between the parapet wall and the roof slab etc shall be chamfered with 150Mrn X 150 mm fillet of mortar (Cement: sand - 1:4) admixed with acrylic pc?' lymer of Sika/ Fosroc/MYK Schomberg/Dr 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent.,Befor 'Chamfering a prime coat shall be given with the slurry of acrylic polymer Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar-including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete.(b)lst Coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitiot.is material on surface saturated dry roof and inside wall of Parapet.Wall upto 600 mm by brush or roller . After 1st coat of application , 45 gsm of Fibre glass cloth to lay when the first layer is still green. 1st coat shOUld be applied @1.50 kg/Sqmt/coat. For the purpose of measurer-11609-1'e entire treated surface will be measured." (c) 2nd Coat :-To apply the 2nd coat of two component acrylic modified read to use, flexible cementtiOus material right angle to the 1st. coat over the glass fibre laid surface: 2nd coat-,should be applied @ 0.7 Sqmt/coat. For the purpose of measurement the entire treated surface will be measured." After three days of drying the 2nd coat , the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Water proofing Brand:- Sika Topseal 109hi / Fosroc Brushbond RFXI Dr. Fixit Pidiffin 2K / MYK Aquafin TG . Product Performance - Chemical Base Part A: Acrylic copolymer, Part B: Specially graded cementitious powder - Density 1.6 kg/I (mixed density) at +27°C Tensile Strength -2 Nimm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Siren th -2 f\l/mm2 concrete failure Accordin' to ISO4624) Slant-Shear Bond Strength -4 Nimm2 (According to FIP 5.15) Elongation at Break -35% Without Fibre Cloth and 20% with Fibre Cloth (According to ASTM D 2370) (d) )Protection of treated surface with PCG :- The treated surface should be covered with 25mm/50mm F'CC of M-20 grade (1.1.5:3). with proper slope ( 1:120) towards the rain outlets in alternate panels of 2 mt x 2 mt keeping 6 rnm gap between the panel joint. Integral water proofing admixture conforming to IS 2645 co of 100 ml per bag of of cement to be added in the screed concreie(paid separately.for this items).All corners shall be chamfered with 150mm X 150 mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface should be packed prorSeqswith ridti:corict'ete and the peripheral mouth to be sealed with,moisture insensitive epoxy putty of. Sika India .Pvt.Ltd. / MYK Schornbefg /Dr Fixit/Fosroc .For the purpose of measurement the entire treated surface will be measured." (e)Groove of PCC surface should be filled with POlysulphide Sealant.(Paid Separately). Be d - Sika India Pvt.Ltd. / MYK Schomberg / Dr Fixit/Fosroc . Warranty for five years.
Covering of treated surface with PCC :-providing 25 mm thick Cement Concrete M20 (1:1:5:3) maintaining slope in alternate 2 mt x 2mt panels With approved quality of stone chips of 20mm to 6 mm size graded and Cleaned sand of F.M.2.5 to 3 including screening, shuttering, and mixing Cement concrete in mixer with admixture of integral water proofing and Placing in position, striking curing, taxes and royalty all complete as per Building specification and direction of E/I. Panels that has been left should Be casted next day. There should be 6 mm gap between panels .brand- Sika _ plastocrate plus, MYK proof WP 10, Fosroc- Conplast X 421 ic Dr Fixit Pidiproof LM+
Providing and filling of 6 mm thick Groove between 25 mm PCC Panels with Polysuiphide Sealant (Porin.g Grade)as per drawings and technical specificationsi6nd direction of E in Charge. (with 18% GST) B rand Sika Polysulphide, Fosrpc-Thioflex 600 Dr. Fixit Pidiseal PS(42P. MY K Seal PS or Euivalent.
Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plgs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing two coats of oil bound distemper of approved make & shade over a coat of cement primer over new surface including preparing the plastered surface by rubbing, smooth with pumic stone or fine sand paper, aplying putty wherever required, scaffolding , washing of flores and taxes etc. all complete as per building specification direction of E/I.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red, Area of slab over 0.50 sqm.
Providing 250mm. wide brick drain in cement mortar (1:6) with av. 250mm. clear depth and 250mm. apron including cost of earthwork involved with 75 mm. ~ cement concrete (1:4:8) over one brick designation 75A flat soling in proper grade and slope at the base, the drain duly plastered in C.M.(1:3) with punning over exposed surface all complete as per building specification and direction of E/l.
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared
Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
Providing 25mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layers 19mm. Thick (1:2:4)with 12mm to 6mm. Size graded stone chips and top layer 6mm. Thicks (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I.
Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curing, taxes and royalty all complete as per building specification and direction of E/I.
Labour for cutting old mosaic or precast terrazo tiles including cost of removing dirt, rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curring, taxes and royalty all complete as per building specification and direction of E/I.
Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
Labour for scrapping old paint with paint remover and below lamp as required on wooden or steel surface including cost of all labour and materials and scaffolding all complete as per building specification and direction of E/I.
Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification)
Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
Grassing with ' Doobs' Grass (Grassing with 'Doobs' grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed) In rows 7.5 cm apart in either direction
Compacting Original ground supporting sub-grade Loosening of the ground upto a level of 500 mm below the sub-grade level, watered, graded and compacted in layers to meet requirement of Table 300-2 for sub-grade construction.
Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
Cast in Situ Cement Concrete M 20 Kerb with Channel (Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M15 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCCM20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409) PCC M20 for Kerb Cast in situ
Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper scaffolding , curing and taxes all complete as per building specification and direction of E/I.
Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete.size of (50x75x6mm)
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I.
Providing 125mm thick reinforced designation 75A brickwork in C.M. (1:4) in Superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, cost of materials, racking out joints to 15mm depth, carriage, taxes and royalty (but excluding the cost of reinforcement) all complete as sper building specification and direction of E/I.
Providing 12mm thick cement plaster (1:3) with clean coarse sand of F.M. 1.5 and including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I
Providing 1.5 mm. cement punning including curing carrage of water withall leads and lifts as per building specification and direction of E/I
Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg
Making soak pit 2.5 m diameter 3.0 m deep with 45x45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. with common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Carriage of materials from source to site work including loading & unloading all complete job as per specification and direction of E/I
Sand 12 KM
Aggregate 22 KM
Brick (7+1) KM
Fly Ash Brick 15 KM
Earth 1 km
Metal 22 KM
Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of Parry Hindustan or any other I.S.S. approved make with 100 mm H.C.I., "p" trap 15 litres C.I.. or C. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32 mm alkathene/P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware where footrest to be fixed in floor 15 mm C.I. body brass spindle stop cock of weight not less than 50 grms. 15 mm P.V.C. connection pipe 450 mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. (A) 580 mm long (c) with 12.5 lit. low level P.V.C. cistern
Supplying, fitting and fixing 40 mm high viterous white glazed earthen ware E.W.C. with "p" trap of Parry Hindustan or any other I.S.S. make including supplying & fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grms. , 15 mm P.V.C. alkathene pipe 45 cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/ cuckoo or other I.S.S. make with hinges or screw etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. (A) With "P" trap. 10 lit. low level P.V.C. cistern
Providing and fixing C.P. brass bib cock of approved conforming to IS 8931 : 15 mm nominal bore
Providing and fixing C.P.brass long body bib cock of approved quality conforming to standard and weight not less thain 690gms.:15 mm nominal bore.
Providing and fixing PTMT Soap Dish Holder having length of 138 mm breadth 102 mm, height of 75mm with concealed fitting arrangements, Weighing not less then 106 gms.
Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 15mm nominal bore, approved brand C.P. fittings.
Providing and fixing C.P. extentsion Nipples 15mm size with 12” BSP threads, 70mm length and 30 mm bredth and weight not less than 18gms
Providing and fixing Mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing.Circular shape 450 mm dia
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern,including painting of fittings and brackets, cutting and making good the walls wherever require :Falt back wash basin size 630X450 mm with a single 15mm C. P. pillar tap.
Providing and fixing PTMT grating of approved quality and colour. 125 mm nominal dia with 25 mm waste hole
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 45 cm length
Providing And fixing 32 mm waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. Concealed work including cutting chases and making good the wall etc.
15mm dia
20mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work
25mm dia
32 mm dia.
40mm dia
Supllying and matarials with lobour for construction inspection chamber of designation class 75b brick deep 600x450 internal diamention having 250mm wall thickness in cement morter(1:6)including 12mm cement plaster (1:4)with punning on inside and cement plaster (1:6)with 600x450mm G.I. cover with frame (weight not less than 36k.g)in foundation and refilling all complete as per specification and direction of E/I.
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. Pipe
Providing and fixing C.P. brass Stop Cock (concealed) of standard designand of approved make conforming to IS 8931 15mm nominal bore, approved brand C.P. fittings.
Providing and placing on terrace (at all floo levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and marking necessary holes for inlet outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing PTMT towel rail trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 178 mm
Providing and fixing Sink Cock eith Swinging casted spout
Providing and fixing PTMT/ C.P. swivelling shower,15mm nominal size, 95mm long, 65mm dia. of approved quality, color & make weighing not less than 40 gms with approximate 80 holes of 1.2 mm dia.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
75 mm diameter
110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
75 mm Coupler
110 mm Coupler
75 mm Single pushfit Coupler
110 mm Single pushfit Coupler
75 mm Single tee with door
110 mm Single tee with door
75 mm Single tee without door
110 mm Single tee without door
75 mm Bend 87.5°
110 mm Bend 87.5°
75 mm Shoe (Plain)
110 mm Shoe (Plain)
Point wiring in PVC conduit, with modular type switch - Wiring for light point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size PVC/G.I. box etc. as required Group A
S/F light plug point with modular type accessories - Supplying and fixing suitable size G.I./PVC box on surface or in recess with phenolic liminated sheet cover in front including providing and fixing 5 pin, 5/6 amps socket outlet and 5/6 amps piano tyep switch connection, painting etc. as required.
S/F power plug point with modular type accessories - Supplying and fixing suitable size G.I./PVC box on surface or in recess with phenolic liminated sheet cover in front including providing and fixing 6 pin, 15/16 amps socket outlet and 15/16 amps piano type switch connection, painting etc. as requird.
Power plug wiring in PVC conduit (2 x 4 sq.mm) - Wiring for light/power plug with 2 x 4 sq.mm. FR PVC insulated copper conductor single core cable for loop earthing as required.
Circuit/submain wiring in PVC conduit - Wiring for Circuit/submain wiring along with earth wire the following sizes PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required.
2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire
2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire
2 x 10.0 sq.mm. + 1 x 10.0 sq.mm. earth wire
4 x 6.0 sq.mm. + 2 x 6.0 sq.mm. earth wire
Wiring in existing conduit - Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. 2 x 4 sq.mm.
S/F four pole MCB isolator - Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioining etc. as required
S/F S.P. MCB DB - Supplying and fixing following way single pole netural, sheet, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 8 way, double door
S/F T.P. MCB DB - Supplying and fixing following way, three pole and netural, sheet MCB ditribution board, 415 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door, Horizontal type
6 way (4 + 18), Double door, Horizontal type
S/F 'C' series, MCB - Supplying and fixing following 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connection, testing and commossioning etc. as required.
6/32 amps, Single Pole
40 amps, TPN
40 amps, DP
50/63 amps, DP
S/F ceiling rose - Supplying and fixing 2 pin 5 amp ceiling rose on the existing junction box/wooden block including connection etc. as required.
ITC fluorescent fitting directly on surface - Installtion, testing and commissioning of Pre-wired, fluorescent fitting/compact fluorescent fitting of all type, complete with all accessories and tube etc. directly on ceiling/wall, including connection with 1.5 sq.mm. FR PVC insulated, copper conduit.
ITC Fluorescent fitting with down rods - Installation, testing and commissioning of Pr-wired, fluorescent fitting/compact fluorescent fitting of all types, complete with all accessories and tube etc. including supplying and fixing ball and socket arrangement, 2 no. down rods of 20mm dia stee.
ITC ceiling fan - Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq.mm. FR PVC insulated, copper conductor, single core cable etc. as required.
S/F piano type switch/socket - Supplying and fixing following piano tyep switch/socket on the existing switch box/cover including connections etc. as required.
5/6 amps, one way switch
3 pin 5/6 amps, socket outlet
Electronic step fan regulator, mini
S/F PVC /G.I. boxes - Supplying and fixing PVC/G.I. box of following sizes on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc. as required.75mm x 75mm x 50mm deep/(4" x 4")
ITC exhaust fan upto 450mm sweep - Installation of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing commissioning etc. as required.
S/F PVC conduit - Supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required. 20mm
S/F Batten holder - Supplying and fixing batten/angle holder including connection etc. as required.
Copper earth plate elecrtode - Earthing with copper earth plate 600mmx 600mm x 3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required (But with charcoal or coke and salt)
S/L 8 SWG copper wire in ground - Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth, including soldering etc. as required
P/F GI lightning conductor final - Providing and fixing of GI lightning conductor final, made of 25mm dia 300mm long, copper tube, having single prong at top, with 85mm dia 3mm thick copper base plate base including holes etc. complete as required.
P/F G.I. lightning conductor tape in horizontal run - Providing and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)
P/F G.I. lightning conductor tape in vertical run - Provding and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run)
MV Cable :- Supply of ISI marked aluminium cable conductor XLPE PVC Insulated Cable as per I.S :7098 armoured , served shaelthed 1100V grade with Termination and laying of cable .- 50 sqmm X 3.5 Core armoured AL Cable for JSEB supply
MV cable laying upto 120 sq.mm. in ground without sand and cover - Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 185 sq.mm. but not exceeding 400 sq.mm. direct in ground including excavation, and refilling the trench etc. as required, but excluding sand cushioning and protective covering.
Supply of ceiling fan :- Supplying and fitting of 1400mm sweep regular /standared model AC fan , including connection with 1.5 sqmm copper wire down rod of standered length ( upto 30cm ) with all acessories as required
Supply of Exhaust Fan :- Supply and fitting of 230mm , 230V AC metal exhaust fan in the existing opening including making good the damage , connection testing commisioning etc as required
S.I.T.C. of following rating surface mounted LED tube light fitting suitable for 230V 50Hz, single phase supply etc. complete as required. 20/22 W LED Tube light
Led bulb 9W/10W :- Supplying and fixing of LED 9W/10W bulb and acessories as required .
Led bulb 9W/10W :- Supplying and fixing of LED 9W/10W bulb and acessories as required .
S.I.T.C of following rating LED Flood lighting luminarie with pressure die cast housing and thoughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50 Hz. Luminarie shall be confirmed to IS: 10322 part-5/section-3 and shall be complete with all necessary accessories as required.90/100W LED Flood light
S.I.T.C of following rating reccess/surface mounted LED round/square shape down light luminarie with pressure die cast housing for single phase supply voltage. Luminarie shall be confirmed to IS: 10322 part-5/section-2 or IEC-62722 with all necessary accessories as required.18/20 W LED Round Down light
Providing of PVC/ XLPE insulated sheathed heavy duty armoured power cable with aluminium conductor of 1.1kV (confirming to IS-1554 part-1) Make-Havells/ Finolex/ Polycab.
2Cx6 sq.mm ( from feeder pillar to main gate light)
4Cx10 sq.mm ( from feeder pillar to Bollard and Street light)
3.5Cx70 sq.mm (Main LT panel to outdoor feeder pillar)
3.5Cx400 sq.mm ( transformer to Main LT panel(2 runs))
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning protective covering and refilling the trench etc as required of following sizes.
upto 25 sq.mm
upto 95 sq.mm
upto 400 sq.mm
11 kV Cable Laying: Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 11 kV grade of size not exceeding 120 sq.mm direct in ground including excavation, sand cushioning protective covering and refilling the trench etc as required.
Supplying and fixing Rewireable DP/TPN Switch Disconnector(SFU): S/F of the follwing way double pole / TPN sheet metal switch discooector fuse unit in existing metal board with rewireable type fuses, includin drilling holes in metal board, making connections etc as required. It will be wall mounted 32A, TP&N
S/F Bus Bar Chamber: Supplying and fixing the follwing capacity busbar chamber with 4 strips of suitable size made of copper, heavy duty complete with all accessories including connections, earthing the body etc. as required. 100A, TP&N
Erection of Steel Pole upto 8m in CC: Erection of steel tubular pole of ;ength exceeding 6.5m but not exceeding 8.0m in cement concrete 1:3:6( 1cement:3coarse sand: 6 draded stone aggregate 40mm nominal size) foundation including excavation and refilling etc as required.
7.0m height Octagonal Hot -dip glavinized pole(BOP-7030) :Supply, installation of 7.0m height OctagonalHot -dip glavinized pole with top dia 70mm, bottom dia 130mm & made of 3mm thick sheet, base plate dimension 200x200x12mm(L X B X T) including suitable sizes of foundation bolt all complete as required. ( without arm)
0.5m single arm suitable for 70mm top pole
0.5m double arm suitable for 70mm top pole
Supply and fixing of 90/100W LED street light fitting ,with die cast aluminium housing of ingress protection of IP65 and complete with all accessories etc on pole including connection and earthing the body etc as required
Erection of metalic Pole of following length in cement concrete 1:3:6 ( 1 cement:3 coarse sand : 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc as required.
Gate Light for Main Entrance :- Providing and fixing, connection of intergal post top lamp for gate light 40W LED post top made in cast aluminium with decorative opal polycarbonate diffuser with IP:65 protection including all other accessories as per drawing provided at the time of work execution or as per the direction of E/I)
LED Bollard Light: Providing anf Fixing of LED Bollard light decorative luminaire light fixture & LED lamp with foundation, commissioning, testing along with civil work with all other accessories as per drawing.
HT Cable:- Supply of ISI marked aluminium cable conductor XLPE PVC insulated cable as per IS:7098 armoured, served, sheathed 11000 volt grade3.5 x 70 Sq mm, 11KV XLPE / PVC Al. Ar. Cable
Supply of 16 Mtr Highmast in one section construction S355 grade as per BS-EN 1025 top dia 150mm bottom dia 360 mm plate thickness 3mm
For 16 Mtr Highmast - ITC of the high mast and light fixture with the help of suitable tools and plants wiring of luminaries
Outdoor Stand Mounted Feeder Panel with 32 Amp TP&N
Outdoor Stand Mounted Feeder Panel with 63 Amp TP&N
EPR insulated PVC Sheathed copper conductor
winch power tools for high mast of double drum
winch power tools for high mast of single drum
2.0 Hp AC motor with forward and reverse motion for highmast
twin dome aviation light for highmast
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 X 50 sqmm ( 35mm)
S/F rewireable double pole/TP&N switch disconnector - Providing and fixing following DP/TP&N sheet metal switch disconnector fuse unit in the existing metal board with rewireable type fuses, including drilling holes in metal board, making connections, etc as required. 100 amps, TP&N
S/F HRC fuse type TP&N switch disconnector -Providing and fixing following TP&N disconnetor fuse switch unit in the existing metal board, with ISI marked HRC fuses, including drilling holes in metal board, making connections, etc. as required 100 amps, TP&N, HRC
S/F MCCB in cubical panel board - Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board, including drilling holes in cubical panel, making connection, etc. as required. 25-100 amps, 16 KA, fixed thermal setting
S/F busbar chamber - Providing and fixing following capacity busbar chamber with 4 strips of length 300mm made of copper suitable for following capacity complete with all accessories including connections, earthing the body, etc. as required. 200 amps
S/F sheet metal ON/OFF Load changeover - Providing and fixing capacity 2 pole/4 pole ON/OFF load changeover switches with side handle operation, in sheet enclosure in existing metal board including drilling holes in metal board, making connection, earthing the body etc. as required. 63 amps, 2 pole
S/F panel mounted changeover - Providing and fixing following capacity 4 pole panel mounted changeover switches in existing cubical panel board, making connection, earthing the body etc. as required. 63 amps, 4 pole
S/F S.P. MCB DB - Supplying and fixing following way, single pole and netural, steel sheet, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 12 way, single door
S/F 'B' series, S.P. MCB - Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 KA, 'B' curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as required
6/32 amps, single pole "B" series
40 amps, single pole "B" series
S.I.T.C of following rating LED Flood lighting luminarie with pressure die cast housing and thoughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50 Hz. Luminarie shall be confirmed to IS: 10322 part-5/section-3 and shall be complete with all necessary accessories as required 240W LED Flood light
Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.
(a) From 0.00 M to 50.00 M below G.L.
(b) From 51.0 M upto 150.00 M
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp
Supplying submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene /Noryl Impeller) up to 20 stages 2 HP
Supplying Full automatic star selta starter to operate induction motor working on 415v 3phase 50hz with no coil. Over load element , On _OFF push buttom with necessary materials and connection to Supply etc complete starter with original sheel steel encloser as per 3914. F.A.S.D starter upto 5 H.P
3 core PVC insulated PVC sheathed copper conductor flat submersible cable. Supplying , Flat flexible submersible cable with ,copper conductor , PVC insulated and PVC sheathed as IS:7098 3 Core 4 Sq mm
Supply fitting and fixing GI pipe 50 mm Dia (TATA or equivalent make) Medium Quaility as per IS:1239 ( part 01 ) 2004
Supply and Commissioning of Structure : Providing Design & Supplying Architectural Membrane, Assembling, hoisting, erecting and placing in position MS Build-up section/Tubular structure (MS built-up section :- Rolled section & plates confirming to IS 2062 Grade Yst 240, Tubular Structure – made from Steel hollow sections, ISI marked conforming to IS 1161/4923, Grade Yst 240, in the profile shape as per drawings with special plate connector, pinion joints, plates, hollow sections etc. with cleaning the surface and including Preparation of detailed Architectural Membraneation and ercetion drawings of Structural steel work from design drawings issued by Engineer-In-Charge
Incorporation of Engineer-In-Charge’s comment on same, transportation from Architectural Membrane yard, cutting, threading, machining, leads and lifts up to all heights, tools and plants and necessary scaffolding etc. required for all operations involved to make structure of Architectural Membrane shade. Equivalent).
Hot finished welded type tubes (Make:- APOLLO/JINDAL/ BHUSHAN/ ISI Mark & Providing and applying the complete structure with anti-corrosive protection coating using double coat of PU Paint over single coat of BONDERITE M-FE AQ-PHOS solution for pre-treatment with one coat of Epoxy primer in required DFT (dense film thickness). The work is to be executed as per technical specification and direction of Engineer-In-Charge. (Make :- ASIAN/ MRF/ BERGER / NEROLAC / JOTUN & Equivalent). Flexible composite Cover
Supplying, Providing, Fabricating, assembling and erection of pre stressed Tensile Membrane Fabric structure with MEHLER Valmex FR 900 MEHATOP N – Type II / SERGE FERRARAI FLEXLIGHT ADVANCED 902 S2, Product code 7211 5256 or equivalent with a TiO2 front side primer, multilayered Nanopolymered flouorinated lacquer, multi-composed PVDF lacquer on both sides, low wick treated, protected against microbial and fungal attack, UV-protected system roofing as per the manufacture’s specification and as per approved drawing.
The sheeting material shall have HT polyester yarns 1100 dtex, weight should be 900 g/m2 (EN ISO 2286-2), White coloured 0.8 mm thick fabric, minimum Tensile strength should be 4300 N/5cm in wrap and 4200 N/5cm in weft directions (DIN EN ISO 1421), minimum Tear strength should be 500 N in wrap and 500 N in weft (DIN 53363), the membrane should be with a minimum of 20 years warranty from the manufacturer and life expectancy 30 years etc. over steel frames with all fittings and fixtures such as Galvanized MS Membrane / End Plate, Shackles, Rigging Screws, Turnbuckles, swedge, fork, keder rods & galvanized MS strands / cables with stainless steel end terminals complete as per Drawing / detail & as per technical specifications and as per the instructions of Engineer-in-charge.
This should also include shop drawing, patterning, forming, cutting, fabrication, hot weld stitch of fabric, Transport to the site, assembling and installation with GI Cables, hardware, EPDM gasket and required accessories for necessary Tensioning Material including lifts up to all heights, tools and plants, and necessary scaffolding etc. required for all operations in all respect for fixing the fabric as approved shape as per drawing and direction of Engineer-In-Charge. Flexible Composite Cover shall be cut and manufactured with High frequency PVC Welding Machine.
Add 18 % GST (in Basic Rate must fill 12)
Add 1% Labour Cess (in Basic Rate must fill 1)
M/S S K TEKRIWAL (BID ID -696747)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.12 MB
BOQ_145708.xls
BOQ • 3.55 MB
F-2-01.pdf
Tender Documents • 3.69 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .