Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
Refer Docs
Closing Date
2 Dec 2026, 12:00 pm6d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
ADMINISTRATOR
CHEYYAR COOP SUGAR MILL LTD
RENEWAL OF MACHINERY BREAKDOWN POLICY
2026_TNCSF_730338_1
CHEYYAR/21395/GA/MBD/INS/2026
Open Tender
General Insurance
Lump-sum
365 days
CHEYYAR COOP SUGAR MILL LTD
THOSE WHO ARE CARRY OUT THIS WORK
3 documents required · 3 mandatory
₹0
Exempted
24 Nov 2026
24 Nov 2026
2 Dec 2026
24 Nov 2026
2 Dec 2026
24 Nov 2026
365 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SG BOXES, NO.880-537-001. 880-537-001-6, 880-537-001-8, 880-537-001-5,
TYPE: SDN-630 HP-600 NL-750, N2-20-62RPM
MAKE : BYSORE FLENDER MECH.GEARS, CALCUTTA
QTY - 4 NOS
SUM INSURED : RS. 8000000/- | 1 | lumpsum | - | - |
| 2 | Power House LT Panel PANE BOARD COMPES. OF I/C-1600AMPS ACB-1 NO.:28244/89 NET CAP-105KA PEAK, BRLA-50KARMA,
0/G 100 AMPS ACB - 3NOS. NO:26554/89, 315/AMPS.SF-1 NO.27462/89-400AMPS. SF 1NO.& 28621/89, 6400AMPS ACB
BUS COUPLER 3200AACB 1NO. EE MAKE T-3032, V.415 50KA, M-105KA: AMPS-3200 NO.826/90
A PANEL BOARD COMPRISES OF I/C 1000 A ACB-1NO.0/G-315 AMPS 3NOS. 400AMPS 2 NOS. 630AMPS 4NOS AND 800 AMPS - 5NOS.
B'BOARD 1 NO. COMPRISES OF I/C 1000 AMPS ACB-1NO.O/G-315 AMPS 1NO. 400 AMPS 3NOS. 630 AMPS SL.NO.5 & 800 AMPS - 3NOS.
EMERGENCY DB-I/C 2NOS.
A) 1000 AMPS ACB - 1NO.
B) 1000 AMPS ACB - 1NO. 0/G 63
AMPS 6 NOS. 100 AMPS 1NO.2NOS.400 AMPS-3NOS.
MAKE : ENGLISH ELE. MAKE
QTY - A.1
SUM INSURED : RS. 3000000/- | 1 | lumpsum | - | - |
| 3 | Transformer No.1 IT-45021
Transformer Make. Prolec (Copper Wound )
Specification Reference No.IS.2026(PT.1)
KVA:2000 Rated Volts:HV 11000,LV433,HV104,97
Amphere: LV26666,74,HV:3 Phase LV3, Type of Cooling: ONAN, Frequency Hz:50
MAKE : PROLEC 1977 - QTY - 2
Transformer No.2:IT-45022 Transformer Make. Prolec (Copper Wound ) Specification Reference No.IS.2026(PT.1) KVA:2000 Rated Volts:HV 11000,LV433,HV104,97 Amphere: V26666,74,HV:3 Phase LV3, Type of Cooling: ONAN, Frequency Hz:50 Impedence Volts % 6.78, Vecter Group: Ref No.Dyn 11
MAKE : PROLEC 1977- QTY - .1
Convertor Transformer Coper wound transformer Total KVA-1750 Rated Volts HV - 11000, 3 Phase - H,V LV1- 690 3Phase-LV LVI-690,LV2-690 SlNo-IT-45023 Type of Cooling -ONAN MAKE : PROLEC GE - QTY - .1
Convertor Transformer Coper wound transformer Rated Volts HV - 11000, LV1 Volts. AT 2U-2V-2W | 690 LV2 Volts AT 3U-3V- 3W | 690 Sl.NO - IT 45024 MAKE : PROLEC GE QTY - .2
SUM INSURED : RS. 1384000/- | 1 | lumpsum | - | - |
| 4 | TWO BUS DUCTS FROM THE SECONDARY OF THE 2
TRANS FORMER TO THE LT ACBs. BUS BARS: 2 RUNS OF
8"X1/2" AL. FOR PHASE.
QTY - 1
TWO NOS. ACBs FOR THE SECONDARY SIDE CONTROL
OF TWO TRANSFORMERS EACH 3200 AMPS. 1PN
QTY - 2
MAKE - KEC
SUM INSURED - RS. 934800/- | 1 | lumpsum | - | - |
| 5M/C S.NO./HP/KVA/AMPS/RPM L1 rate is arrived based on lumpsum basis | |||||
| 5.01 | Syp. Air Compressure
QTY - 2
MAKE - KIRLOSKAR
SUM INSURED - RS. 450000/- | 1 | lumpsum | - | - |
| 5.02 | Centrifugal Compressure
QTY - 2
MAKE - INGERSOL RAND
SUM INSURED - RS. 400000/- | 1 | lumpsum | - | - |
| 5.03 | Rake carrier gear box
QTY - 4
MAKE - RADICO
SUM INSURED - RS. 600000/- | 1 | lumpsum | - | - |
| 5.04 | Cane carrier gear box
QTY - 1
MAKE - RADICO
SUM INSURED - RS. 150000/- | 1 | lumpsum | - | - |
| 5.05 | Centrifugal (NHEC)
QTY - 7
MAKE - NHEC
SUM INSURED - RS. 6168803/- | 1 | lumpsum | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.71 MB
BOQ_876487.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .