| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.5 LAccepted-AOC | ₹36.5 L | L1 | Accepted-AOC ok |
| 2 | L2₹36.8 L+₹32,205 (0.88%)Rejected-AOC | ₹36.8 L+₹32,205 (0.88%) | L2 | Rejected-AOC ok |
| 3 | L3₹38.8 L+₹2.4 L (6.54%)Rejected-AOC | ₹38.8 L+₹2.4 L (6.54%) | L3 | Rejected-AOC ok |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
2 Sept 2021, 6:00 pmClosed
GE WEST BAREILLY
GE WEST BAREILLY
REPAIR MAINTENANCE OF LT EXTERNAL ELECTRIFICATION, LT UG CABLE, PAINTING OF POLES AND ALLIED WORKS UNDER GE WEST BAREILLY
2021_MES_446122_2
8946/C/E8
Open Tender
Civil Works
Item Rate
180 days
GE WEST BAREILLY
SCANNED COPY OF ENLISTMENT LETTER IN MES IN RELEVANT CLASS CATEGORY SCANNED COPY OF APPLICATION ON LETTER HEAD OF FIRMSCAN COPY OF DD OF RS 500.00 IN FAVOUR OF GE WEST BAREILLY FROM ANY NATIONALISED OR SCHEDULED BANK SCANNED COPY OF REGISTRATION
6 documents required · 6 mandatory
₹500
Yes
GE WEST BAREILLY
₹80,000
Yes
11 Sept 2021
14 Aug 2021
4 Sept 2021
14 Aug 2021
2 Sept 2021
21 Aug 2021
14 Aug 2021 - 21 Aug 2021
Amount
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth and getting out in soft/loose soil for laying of under ground cable and foundation of poles complete all as specified and directed.
Returning, filling in, including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and directed.
Removing of excavated soft/loose soil not exc 50 m & depositing where as directed at a level n.exc 1.5 m above from starting point completed all as specified and directed.
Taking out old defective cable from trenches/ floor/road/wall/pipe/pole /service connections of any size , testing with LT magger , seggregating the serviceable part of cables and store for relaying complete all as specified & directed by Engr-in-charge.
Supply and laying in replacement of OH ACSR Conductor / XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor 1100 volt grade, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe of cross sectional area 10 Sq mm 2 core all as specified and directed. Note :- Rate deemed to be inclusive of connection including cable glands and lugs.
All as per Ser item No 5 here-in-before but 10 Sq mm 4 core
All as per Ser item No 5 here-in-before but 16 Sqmm 2 core
All as per Ser item No 5 here-in-before but 16 Sq mm 4 core
All as per Ser item No 5 here-in-before but 25 Sq mm 4 core
All as per Ser item No 5 here-in-before but 50 Sq mm 3.5 core
All as per Ser item No 5 here-in-before but 70 Sq mm 3.5 core
All as per Ser item No 5 here-in-before but 95 Sq mm 3.5 core
All as per Ser item No 5 here-in-before but 120 Sq mm 3.5 core
All as per Ser item No 5 here-in-before but 150 Sq mm 3.5 core
All as per Ser item No 5 here-in-before but 185 Sq mm 3.5 core
All as per Ser item No 5 here-in-before but 240 Sq mm 3.5 core
All as per Ser item No 5 here-in-before but 300 Sq mm 3.5 core
M&L for Straight through joints heat shrinkble type 1.1 KV for PVC insulated and sheathed aluminium conductor under ground cable of size 25 to 50 sqmm 3.5 / 4 core including testing of joints after completion complete all as specified and as directed.
All as per Ser item No 6 here-in-before but 120 to 185 sqmm 3.5 core
All as per Ser item No 6 here-in-before but 240 sqmm 3.5 core
M&L for sand cushioning with layer of sand 8 cm thick before laying of cable and 15 cm after lying of cable in trenches/ducts complete all as specified & directed.
M & L for brick protection to cable using old size sub class 'B' bricks, laid flat/lengthwise perpendicular to the axis of cable all as specified & directed.
M&L Cutting of floor/wall/road/footpath for removal of LT U/G cable of any size/description and making good the same as per existing specification after relaying the same or new cable and all as specified & directed.
M&L for Boring of holes under road /pavement/hard standing or any other situation by mannual means for 100/80/50 mm bore at the depth not less than 1 mtr below ground level for crossing the cable and making good both the ends all as specified and directed at site. Note :- GI pipe shall be measure and paid separately under respective item.
S & F in replacement GI pipe light grade of following dia for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified & directed. (a) 50 mm dia
(b) 80 mm dia
(b) 100 mm dia
M&L for stay assembly complete with accessories and fittings of diameter of stay rod in 20 mm including earth work complete all as specified and directed by Engineer -in-Charge.
Dismantling stay assembly complete from the pole all as specified and directed by Engineer -in-Charge.
Dismantling of LT PCC/steel tubular pole incl coping, foundation etc and serviceable insulators from poles for reuse and shifting of poles to E/M yard or any other location complete all as specified and as directed
Supply and erection, in truly vertical position, LT Steel tublar swaged pole complete with cast iron base plate finial taper plug, bolt , nut and screwed type 410 SP 31 09 mtrs long Class -10 including painting of poles with two coats of synthatic enamel paint in black and white strips upto 1.5 mtr height from coping over a coat of red oxide primer including numbering of poles as directed by Engineer in charge. Make : Bansal/Jindal/National tube. Note : PCC, Earth work and MS work as cross arms clamps etc will be measured and paid separately.
M&L for PCC type B1 (1:2:4) using 20 mm graded aggregate as in coping to the poles complete all as specified and directed.
M&L for PCC (1:3:6) type C2 using (40 mm graded aggregate in foundation, filing and mass concrete complete all as specified and directed.
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers welding, bending cold or hot, drilling holes for bolts, in any hape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint.
Dismantling of cross arms of MS channel or angle sections etc complete and setting aside for re-use with in 50 mtr complete all as specified and directed.
Dismantling insulators any type any size from LT poles all as specified and directed by Engineer -in-Charge.
M&L for Pin type , porcelain, vitreous, white, borwn or green insulator including one galvanised mild steel spindle , two galvanised mild steel spindle, two galnvanised iron wahers and one galvanised iron nut, 100 mm height,65 mm dia.
Dismantling of ACSR from the poles all as specified and directed by Engineer -in-Charge.
M&L Aluminium conductor, steel reinforced incl stringing in position all as specified and directed by Engineer -in-Charge.
M&L for earthing complete with galvanised iron steel earth plate of size 600 x 600 x 3.15 mm thick burried directly in ground (earth pit not less 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below ground level connected to thick electrode and 32x6 mm GI strip as earthing by means of nuts bolts check nuts and washers made of galvanised iron or steel earth wire protected by galvanised iron pipe 15 mm bore (medium grade) and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1 precast RCC cover slab 54 x 54 cm x 5 cm with reinforcement with 8 mm TMT bars @ 150 C/C with one handle and funnel for watering charcoal or coke and salt in alternate layers & necessary earth work in soft/loose soil complete all as shwon in electrical plate No 5 of SSR Part-I including testing on completion all as specified and directed.
M&L for painting the external exposed surfaces of steel tubular swaged/rail poles alongwith cross arms, bracket and connected accessories with one coat of aluminium paint including preparation of old painted surfaces and writing the details of the pole in white letters on black back ground complete all as directed.
Material and labour for Cutting of bushes and cleaning the area around the sub station including two pole/four pole structures premises complete all as specified and as directed.
S&F of PVC LT OH line spacer for 5 wires complete all as specified and directed.
S&F of PVC LT OH line spacer for 4 wires complete all as specified and directed.
S&F of PVC LT OH line spacer for 3 wires complete all as specified and directed.
Removal of Tree fallen on HT/LT overhead lines by cutting branches,bushes by electric cutter or manual and lifted by crane /Hydra/Manual including collection and depositing the retrieved timber at a place as directed by Engineer-in-charge.
Lopping / prooning of tree branches upto the extend to obtain clearance all around the LT over head lines / HT over head lines conductor upto 3 mtr from furthest conductor on pole including removing of cut branches and cleaning of site complete all as specified and directed.
Restretching of existing aluminium conductor steel reinforced (ACSR) straining properly on insulators and binding with aluminium tape/binding wire connectors, PG clamps , jumpers etc complete all as specified and as directed.
S&F in replacement MCCB 415 Volts 4 pole 630 Amps 50 Hz 50 KA of existing make model and type alonwith spreader terminal with adjustable thermal setting including lugs/thimbles of suitable size in existing panels complete all as specified and directed by Engr-in-Charge. Make L&T/Legrand /Indoasian.
Disconnection of electric connection from LT Panel of any size dressing of cable including replacement of burnt out aluminium lugs and fixing with new lugs, nuts bolt etc complete including all inter connection with aluminium strip of size not less than 0.6Mx0.03Mx6MM 1100 volts grade and suitable current rating including painting of Panels complete with inner & outer with two coats of synthetic enamelled paint over a coat of primer including excavation & earth work required for taking out & refixing the incoming and out going cable etc complete all as directed by Engr -in Charge; Note :-Replacement of unserviceable accessories parts shall be measured and paid separately under relevent items.
S&F in replacement of unserviceable parts of LT Panels complete all as specfied and as directed. Make : L&T /Leagrand
MCCB 400 Amp 36 KA 4 pole adjustable type 415 Volts 50 Hz.
MCCB 250 Amp 36 KA 4 pole adjustable type 415 Volts 50 Hz
MCCB 200 Amp 36 KA 4 pole adjustable type 415 Volts 50 Hz
MCCB 125 Amp 25 KA 4 pole adjustable type 415 Volts 50 Hz
MCCB 63 Amp 16 KA 4 pole 415 Volts 50 Hz
Aluminium bus bar 600 Amp with colour code & porcelain insulator complete suitable for 3 phase 4 wire system of length not less than 1 Mtr.
Phase Indicator lamp RYB .
S & F Rubber Mat of size 2mtr x 1mtr x 12mm at Elect Supply / DG Set installations complete all as directed by Engr in Charge
S&F in replacement 1100 volts grade PVC insulated aluminium conductor screened served with inner sheathed in service connection flat twin core cable of size 10 sqmm complete all as specified and directed.
All as per Ser item No 37 here-in-before but 06 sqmm complete all as specified and directed
All as per Ser item No 37 here-in-before but 04 sqmm complete all as specified and directed
M&L for day to day maintenance of external electric system i.e feeding areas of various sub stations by attending external electric complaints by maintaining all incoming and outgoing LT Feeders, LT OH lines and rectification of any fault occured in the feeder of elect distribution system involving jumpers, ACSR conductors LT cables, LT panels, fuse element, all LT feeders and connection in the service wires/cables, Removing of unserviceable portion of LTcable from trenches & cutting of cable ends & fixing of new aluminium lugs with criping tool & refixing on pole/panel/trench and attending of complaints for No Lights from poles and other type of faults in LT cable will be attended immediately by the contractor after getting the complaints.
Supply only Aluminium Lugs/connectors of size 16 sqmm
Supply only Aluminium Lugs/connectors of size 25 sqmm
Supply only Aluminium Lugs/connectors of size 35 sqmm
Supply only Aluminium Lugs/connectors of size 50 sqmm
Supply only Aluminium Lugs/connectors of size 70 sqmm
Supply only Aluminium Lugs/connectors of size 95 sqmm
Supply only Aluminium Lugs/connectors of size 120 sqmm
Supply only Aluminium Lugs/connectors of size 150 sqmm
Supply only Aluminium Lugs/connectors of size 185 sqmm
Relaying only serviceable LT UG Cable obtained from Srl item No 04 of any size and discription including necessary cable lugs. ( All relevent items like excavation, earth work, sand cushionning, bricks etc shall be measured seperatly under respective item of Sch.)
M&L for fabrication of MS busbar chamber of nominal dismension 900mm x 600mm x 400mm duly provided with aluminium busbar of size 50mm x 6mm fixed on porcelain insulators TPN type out door weather /vermin proof with both way opening duly provided with neoprene rubber gasket along the doors openings pedestal type duly painted power coated on CRCA steel sheet encloser with one No incoming MCCB 250Amp 25 KA incl making connection/thimbles of required size complete all as specified and directed.
Note : (i) Complaints pertaining to LT External Electric Supply shall be resolved by the contractor immediatelly after getting complaints. In case of failure on the part of contractor to resolve to the complaints within stipulated time, a penalty of Rs 1000/- per day per complaint shall be imposed from the contractor. (ii) The contractor or his authorised representative shall report to the concerned JE E/M at 09:00 hours dailly on all working days to receive order/instructions of the work. A register shall be maintained to record all orders & instructions and their complaints and is to be signed by the contractor/his representative and the Engineer-in-charge/JE E/M concerned. (iii) Work done register to be maintained by the contrator. A separate Docket complaints slip book shall maintained by the contractor to note the complaints/jobs and get it signed by the user after completion of work and submits to the JE-in-Charge.
RAZA ENTERPRISES
Ishtiaq and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .