| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 LAccepted-AOC 72 5 53 PIPE ROAD PO BARRACKPORE DIST 24 PARGANAS NORTH PIN 700120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹13.4 L+₹50,565 (3.91%)Rejected-Finance | L2 | Rejected-Finance Rejected due higher rate from Lowest bidder | |
| 3 | L3₹13.7 L+₹73,192.80 (5.66%)Rejected-Finance | L3 | Rejected-Finance Rejected due higher rate from Lowest bidder | |
| 4 | L4₹13.8 L+₹90,819.40 (7.03%)Rejected-Finance 32 LOOTERY MOHAL ORDERLY BAZAR PO BARRACKPORE DIST 24 PARGANAS NORTH KOLKATA 700 120 W B | KOLKATA | 24 PARGANAS NORTH | WEST BENGAL | 700120 | L4 | Rejected-Finance Rejected due higher rate from Lowest bidder | |
| 5 | L5₹14.1 L+₹1.2 L (9.33%)Rejected-Finance | L5 | Rejected-Finance Rejected due higher rate from Lowest bidder |
Tender Value
₹11.5 L
EMD Value
₹23,000
Closing Date
17 Feb 2023, 6:00 pmClosed
GE AF Barrackpore
GE AF Barrackpore Post Barrackpore Dist 24 Parganas North Kolkata 700120
REPAIR / REPLACEMENT / MAINTENANCE OF LIGHTING CONDUCTOR, EARTHING, LT FEEDER PILLAR BOX, SWITCH GEARS SYSTEM, LT UG CABLE AND CONNECTED MISC WORKS AT JAFFARPORE, KANCHARAPARA, LOS DUM DUM AND BARASAT AREA UNDER GE (AF) BARRACKPORE
2022_MES_559012_3
8380/BKP/AF OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF Barrackpore
Class-E,
Category-b(i)
2 documents required · 2 mandatory
₹500
GE AF Barrackpore
₹23,000
Yes
2 Mar 2023
27 Jan 2023
20 Feb 2023
27 Jan 2023
17 Feb 2023
3 Feb 2023
Amount
Material and labour for earthing complete with copper earth plate electrode of size 600 x 600 x 3.15mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to copper strip of size 20 x 3mm earth lead by means brazing after fixing of nuts, bolts, check nuts, washers of galvanised iron steel, protected by galvanized iron pipe 40mm bore (light grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x 10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion including taking down old existing unserviciable earthing complete all as specified and directed. Note:- Strip upto 7.5m length including testing shall be included in quoted rates.
Material and labour for earthing complete with GI earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI earth strip of size 32 x 6 mm earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 40mm bore (light grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part-I including testing on completion including taking down old existing unserviciable earthing complete all as specified and directed. Note:- GI strip upto 7.5m length including testing shall be included in quoted rates.
Material and labour for earthing continuity of 20 x 3.15 mm copper strip with saddles and fixing screws on porecelain insulator/ spacer fixed at every 1 mtr length for extension of earthing strip on roof/wall and joining the same with existing/new earth test point after taking down old existing unserviceable copper strip complete all as specified and directed. Note : Joining of copper strip shall be made by brazing after fixing of nuts & bolts.
Material and labour for galvanised iron strip of size 32 x 6mm with saddles and fixing screws on poreceling insulator/ spacer fixed at every 1 mtr length for extension of earthing strip on roof/wall and joining the same with existing/new earth test point including taking down existing unservicicable GI strip complete all as specified and directed.
Material and labour for 40mm dia galvanised steel tubes (light grade) with fittings, laid in trenches / wall for protection of underground earth strip when crossing the road / fixing on wall including taking down old unserviciable GI tube complete all as specified and directed.
Material and labour for cutting, bending, welding of MS flat iron of size 30mm x 3mm for making of clamps as required size and shape including nut/bolts and painting with two coat of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed .
Material and labour for repairing of lightning conductor & air termination rod single or multi pointed of any type and size including dismantling of the full set and refixing after cleaning, replacing nut bolts, making straight of GI pipes, refixing of clamps and nut bolts, fixing of earth strip with proper welding/jointing by nut bolts without any loose joints, replacing of defective/broken saddle piece of any size and type and from air termination point upto earth pit, re-allignment of earth strip by fixing it on wall and reapring of disturbed portion and making good as per existing complete all as specified and directed.
Supply and fix in repair MCCB 4 pole, 415 Volts, 63 Amps with breaking capacity 25 KA (adjustable thermal magnetic release setting) complete all as specified and directed.
Supply and fix in repair MCCB 4 pole, 415 Volts, 100 Amps with breaking capacity 25 KA (adjustable thermal magnetic release setting) complete all as specified and directed.
Supply and fix in repair MCCB 4 pole, 415 Volts, 160 Amps with breaking capacity 25 KA (adjustable thermal magnetic release setting) complete all as specified and directed.
Supply and fix in repair MCCB 4 pole, 415 Volts, 200 Amps with breaking capacity 36 KA (adjustable thermal magnetic release setting) complete all as specified and directed.
Supply and fix in repair MCCB 4 pole, 415 Volts, 400 Amps with breaking capacity 36 KA (adjustable thermal magnetic release setting) complete all as specified and directed.
Material and labour for air termination single pointed copper rod,12mm dia and 300mm long including necessary fixing arrangment using clamps,nuts and nuts including taking down existing unserviceable air termination rod complete all as specified and directed.
Material and labour for test point termination box made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 Nos, 8 mm dia, 25mm long hexagonal heads screw for lighting conductors including taking down old existing unserviciable termination box complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5mtr in depth and getting out in soft/loose soil for laying of under ground cable complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 250mm in soft/loose soil, complete all as specified and directed.
Removing excavated materials (soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above from starting point complete all as specified and directed.
Material and labour for PCC (1:3:6) type C-2 (using 40 mm grade stone aggregate) as in foundation, filling and mass concrete including demolition of cement concrete (unreinforced) and removal of rubbish from the site complete all as specified and as directed.
Material and labour for PCC (1:3:6) type C-2 (using 40 mm grade stone aggregate) as in foundation and mass concrete complete all as specified and directed
Supply, laying, connecting and testing XLPE insulated, PVC sheathed, armoured LT electric power UG cable (heavy duty with stranded aluminum conductor) of size 95 Sqmm, 3.5 core, 1100 Volts (earthed) grade, confirming to IS-7098 (Part-I) laid through duct/ pipe / in trench etc. with cable glands & suitable size of aluminium lugs including taking down old unserviciable existing cable complete all as specified and as directed. Note : Earth work, brick protection and sand cushioning and GI Pipe Shall be measured and paid separately under respective item.
All as per above Item No 20.00 but size of 70 Sqmm 3.5 core and -ditto-.
All as per above Item No 20.00 but size of 50 Sqmm 3.5 core and -ditto-.
All as per above Item No 20.00 but size of 35 Sqmm 3.5 core and -ditto-.
Material and labour for sand cushioning with clean and dry river sand for protection of PVC cable with approved sand of uniform thickness. laid dry, filling in trenches and punning down in proper required layers complete all as specified and as directed. Note:- Punned down thickness shall be measured for payment.
Materials and labour for brick protection cover to underground cables with sub class ‘B’ of size 23 X 11.5 X 7.5 cm, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and as directed.
Material and labour for cutting the road/hard standing and making good disturbed surfaces by using PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) for laying pipe complete all as specified and directed.
Supply and fix in repair 50mm bore GI pipe (light grade) with all fittings for protection of cables to cross under road, hard standing, pavement etc complete all as specified and as directed.
Materials and labour for complete removal of existing treatment of old steel surfaces of LT panel board / feeder pillar box / AMF panel etc and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer including preperation of surface complete all as specified and directed.
Material and labour for complete disconnecting of APFC panel from all incoming/outgoing connection of any capacity, checking the serviceability of all components i.e. existing capacitors, contactors, MCB's, including replacement of indicator lights-03 Nos, burnt out 2.50 Sqmm PVC insulated copper wire-40RM, copper thimble-08 Nos, MCB's SPN 'C' Series , 10 KA (6-25Amp)- 02 Nos and re-connect the same after thoroughly clean and testing complete all as specified and directed. Note:- Unserviciable power factor controller shall be measured and paid separately under respective items as supply only.
Supply only tamper proof intelligent power factor controller with digital multi function meter display of capacity 8 Step 440 volt, 3 phase 50 Hz cmplete all as specified and directed.
Material and labour for cleaning once in a month by spraying of weeds herbicide for kill unwanted vegetation around near and around electrical power house installation, around all LT panel boards and feeder pillar boxes, cutting grass, removing unwanted bushes, removing debris etc and making good of undulated ground by filling fresh soil and levelling the area to existing ground level, removing unwanted debris from the site complete all as specified and directed. Note: (i) Location - Jafferpore AF camp and approx area - 700 Sqm. (ii) In case of damage to any existing assets such as panel boards or any type of things, contractor has to make good as per the existing without any extra cost.
All as per Ser item No 31.00 here in before but in Location - Kancharapara and approx area - 900.00 sqm and -dittio-.
All as per Ser item No 31.00 here in before but in Location - LOS DUM DUM AF camp and approx area - 400.00 sqm and -dittio-.
Supply and fix in repair PVC DLP cable trunk of size 100mm width and 50mm depth with proper casing and lock arrangement, and all suitable accessories such as body joint of size 100 x 50mm, cover joint 75mm, variable internal angle 100 x 50mm, fixed external angle 100 x 50mm, fixed flat angle 100 x 50mm, end cap 100 x 50mm fixed on wall, inserting LT UG cables inside the cable tray with suitable clamps after disconnecting the cables from LT panel board, re allignment of cables from existing route, including minor excavation for looping and spare cables outside the room before entering the cable into the cable tray, including connection of cables in LT panle board and testing of all distribution lines omplete all as specified and directed.
Labour only to attend complaints of street lights, hanger lights, focus lights and flood lights of any capacity and type with the help of one skilled electrician and one helper and replacement of defective wires, rectifying loose connections, repair of cable junction box, replacement of LED drivers, surge arresters etc complete all as specified and directed. Note: (i) All complaints must be atttended and rectified within 24 hrs from the time of information on regular interval or requirement basis. (ii) All the spares such as cables, cable junction box, street light brackets, LED street lights and any other connected accessories shall be measured and paid under respective item separately as supply only. (iii) Repair and replacement of all kind as mentioned above in each pole shall be considered as one job at one time. (iv) Safety equipments, ladder and vehicle shall be provided by the contractor at his own cost. (v) Record of complaints shall be maintained in a neat long register by the contractor and shall be put up to Engineer in charge and site executive for record before payment.
Supply only PVC insulated copper cable of 1.5 sqmm, 3 core consisting of 2x1.5 sqmm as live and neutral wire and 1x1.5 sqmm as earth wire complete all as specified and directed.
Supply only cable junction box 210x155x92mm in size, for 10-16sqmm cable size, made out of thermoplastic sheet having IP-66 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32 - 2 nos) fixed on poles with flat iron clamps of size 25x3mm, nuts, bolts, washers etc. complete all as specified and as directed.
Supply only street light bracket made of 1.5 RM length of GI pipe of medium grade of 32 mm dia in proper shaped, bend, threaded and drilling holes for wire entry and MS clamps (02 Nos) of suitable size in proper shape cmplete all as specified and directed.
Supply only 60 Watt LED street light fitting made with pressure die cast housing with toughened glass with high powered LED, IP-66, 5700K, 230 Volt complete all as specified and directed. Make:- Crompton Cat No TRP-409-60-57-SL-GL-NSG or equivalent model of Philips / Bajaj / Havells / MAGIK.
Supply only 70 Watt LED street light fitting made with pressure die cast housing with toughened glass with high powered LED, IP-66, 5700K, 230 Volt complete all as specified and directed. Make:- Crompton Cat No TRP-409-70-57-SL-GL-NSG or equivalent model of Philips / Bajaj / Havells / MAGIK.
Supply only 150 Watt rectangular LED flood light fitting made up of pressure die cast with toughened glass and high power LED ,IP- 66, 230 Volt, IP-66, 5700K complete all as specified and directed. Make:- Crompton Cat No CFS-501-150-57-60D-SL-GL-NGG or equivalent model of Philips / Bajaj / Havells / MAGIK.
Supply, install, testing and commissioning of factory made outdoor cubical type (CPRI approved) LT Panel of size 1.5Mx1.2Mx0.6M fabricated out of 3.15mm thick CRCA sheet, angle iron frame of size 50mm x50mmx6mm, totally enclosed weather, dust & vermin proof with cable entry and exit through bottom with double compression copper stainless steel cable glands and gaskets, front & back side operated double door with proper hinge , cable termination box and locking arrangement with copper bus bar of suitable rating fixed on porcelain insulator and painting to panel board complete with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer with spray painting on internal and external surfaces including internal wiring using with suitable size of copper conductor cables and aluminium strips for incoming and outgoing connections of all switches / MCB's / MCCB', Bus bar cable alloy, bus bar shall be insulated with colour code / sleeves / tapes including necessary PCC (1:3:6) type C-2 (using 40mm graded stone aggegate) for foundation / plateform including taking down old unserviciable panel board complete all as specified and directed.
LT panel board shall constitute with follwing accessories :- INCOMING :- (a) MCCB 4 pole 160 Amp, 415 volts, 25 KA (adjustable thermal and magnetic release setting) - 01 No. OUTGOING :- (a) MCCB 3 pole 100 Amp, 415 volts, 25 KA (fixed thermal and magnetic setting type) - 02 No. (b) MCB SPN 40 Amp, 10KA- 02 No. (c) LED indicator lamp (RYB) - 01 Set (d) Copper bus bar 300 Amp- 04 No. Note:- Quoted rates are inclusive of following:- (i) Contractor shall submit the design of the panel alongwith accessories for approval of GE before fabrication. (ii) Plateform of suitable size in PCC 1:3:6 type C-2 (using 40mm graded stone aggegate) minimum 40 cm below NGL and 45 cm above from NGL.
Materials and labour for taking out of LT panel board from the existing site of LOS DUM DUM and breaking old UNSV platform after disconnecting all the cables and removing all burnt out old unserviciable switch fuse unit and fixing / fabricating suitable angles and sheets for fixing new MCCBs and repairing of doors, hinges, locks and saddles, rewiring of CTs/PTs and bus bars etc and refixing of broken bus bars after repairing it and complete removal of existing treatment of surface and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer and refixing of LT panle board to the existing location, including PCC platform, and connecting of all LT UG cables and testing of panel board with existing load complete all as specified and directed. Note: (i) MCCBs and other accessories shall be measured and paid separately under respective items as supply only. (ii) PCC for platform shall be measured and paid separately respective items.
(iii) Welding works for MCCB mounting structure and enclosure shall be included in the quoted unit rate. (iv) Cost of painting of panel shall be included in quoted unit rate. (v) Cost for cable gland, cable lugs and other all kind of necessary accessories shall be included in quoted unit rate. (vi) Internal wiring of RYB indicators, all kind of meters and CT/PT shall be done by the contractor before re-installation at site and which cost shall be included in quoted unit rate. (vii) No vehicle shall be provided by the department for the conveyance of technicians and transportation to workshop etc. (viii) All other swich fuse units and MCCBs shall remain fitted in the LT panle board and if required, contractor has to remove it from panel and after repair works, he should fit it back as per existing position including necessary cable connections etc at his own cost.
Supply only MCCB 4 pole, 415 Volts, 100 Amps with breaking capacity 25 KA (adjustable thermal magnetic release setting) complete all as specified and directed.
Supply only MCCB 4 pole, 415 Volts, 200 Amps with breaking capacity 36 KA (adjustable thermal magnetic release setting) complete all as specified and directed.
Supply only MCCB 4 pole, 415 Volts, 320 Amps with breaking capacity 36 KA (adjustable thermal magnetic release setting) complete all as specified and directed.
Supply only aluminium bus bar 400 Amp capacity complete all as specified and directed.
TAPAS ENGINEERING CO
NC BOSE AND CO
Das and Brothers
SARKAR AND COM
M/S A. J. CONSTRUCTION
VISHAL ENTERPRISE
KUMAR ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .