Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹39.7 LAccepted-AOC NO 24 54 21 5 LIG 408 VUDA COLONY VINAYAKA NAGAR GAJUWAKA VISAKHAPATNAM 530026 | VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | 1 | Accepted-AOC AWARDED BEING THE LOWEST TENDERER | |
| 2 | 2₹43.5 L+₹2.7 L (6.60%)Rejected-Finance | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹43.7 L+₹2.9 L (7.10%)Rejected-Finance | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 4 | 4₹44.9 L+₹4.2 L (10.2%)Rejected-Finance | 4 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 5 | 5₹45.9 L+₹5.1 L (12.6%)Rejected-Finance DOOR NO 10 89 BC COLONY PAPAYYARAJUPALEM SUJATHANAGAR VISAKHAPATNAM 530 051 | VISAKHAPATANAM | ANDHRA PRADESH | 530051 | 5 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹46.7 L
EMD Value
₹93,400
Closing Date
16 May 2023, 6:00 pmClosed
GARRISON ENGINEER NAVAL BASE VISAKHAPATNAM
GARRISON ENGINEER NAVAL BASE GANDHIGRAM POST VISAKHAPATNAM 530005
AS AS TO BUILDING NO P-130 (AL BLOCK) AT NAUSENA BAUGH AND PROVN OF AIR CONDITIONER FOR COMPUTERS AND SERVER ROOMS AT HQ ENC UNDER GE (NB) VISAKHAPATNAM
2023_MES_590056_1
C/8156/23-24/E8 / Token 11 of 2023-24
Open Tender
Civil Works
Item Rate
180 days
VISAKHAPATNAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER NAVAL BASE
₹93,400
Yes
14 Aug 2023
18 Apr 2023
18 May 2023
18 Apr 2023
16 May 2023
2 May 2023
Amount
Demolition of cement concrete (unreinforced) in any position not otherwise specifically provided for as in roof padding etc including old detoriated roof treatment and bedding layer and removing debries and rubbish to a distance outside MD land complete all as specifed and directed.
M & L for 10 mm thick screed bed in CM 1:4 mixed with WPC as per manufacturer's instructions over 25 mm thick PCC 1:2:4 type B-0 (12.5mm graded aggregate), as in levellig course, Supply and lay polymeric water proofing membrane of weight 3kg/sq.m incorporating a centre core of 90 micron thick HMHDPE film including coating the surface with a coat of water based bituminous primer @ 100gms/sq.m., followed by a coat of blown bitumen of grade 85/25 or 90/15 @ 1.2kg/sq.m. each at top and bottom of the membrane including sealing all joints by thermo fusion with minium 10cm overlap incl grooving & inserting in parapt wall all as per manufacturers instructions and applying two coats of aluinium paint over a coat of primer over the top surfaces complete all as specified and as directed. (Note: WPC shall be measured and paid seperately)
Supply only integral water proofing compound (ISI marked) complete all as specified and directed.
Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness, (Below or above Ground level) and disposal of debris and rubbish to a distance upto outside MD land complete all as directed by the Engr-in-Charge
Demolition of un-reinforced cement Concrete of any description and in any position not otherwise specifically provided for and removing rubbish to outside MD land complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposal of debris and rubbish to outside MD land complete all as specified and directed.
M & L for 25 mm thick, plain cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) as in sub-base of flooring, etc and finished the surface even and rough complete all as specified and directed.
M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for glazed, coloured, ceramic, tiles of size (350mm x 250 mm/450mm x 350mm/300mmx450mm) x 6 to 7 mm thick, on vertical surfaces such as skirting, dados etc, including 10 mm thick bedding in cement mortor 1:4 and set & jointed in neat cement slurry & pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for rendering 10 mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces mixed with integral water proofing compound as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item)
M & L for applying Chemical Injection treatment in the form of Pressure Grouting by drilling 20 mm dia holes, 60mm deep @ 100mm grid at junction of bottom floor and all the internal wall surfaces of the sunken slab of toilet by injecting Cement slurry mixed with Grout Admixture "CONBEXTRA EP 10" of M/S Fosroc Chemical India (P) Ltd or its equivalent make as per list of manufacturer's at 225 Grams for 50 Kg of cement and applying a coat of Brush Bond RFX of M/S Fosroc Chemical India (P0 Ltd or its equivalent make as per list of manufacturer's complete all as per manufacturer's instructions and as directed
M & L for Plain cement concrete 1:5:10, type E-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
Demolition of reinforced cement concrete in any position not otherwise specifically provided for and removing rubbish to outside MD land complete all as specified and directed.
M & L for use & waste Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizonal or sloping) for flat rough finished surfaces of concrete complete all as specified and directed.
M & L for use & waste Form work to chajjas, troughs and similar items including edges flat for rough finished surfaces of concrete complete all as specified and directed.
M & L for Reinforced Cement Concrete 1:1.5:3, Type A-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, shelves etc complete all as specified and directed. (Note : Reinforcement will be measured & paid seperately)
M & L Reinforced Cement Concrete 1:1.5:3, Type A-1 (Nominal Mix) (using 20 mm graded stone aggregate) as in chajjas etc complete all as specified and directed. (Note : Reinforcement will be measured & paid seperately)
S & F high strength corrosion resistant TMT steel bars 6mm to 8mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
S & F high strength corrosion resistant TMT steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal of debris and rubbish to a distance n.exc 100m as directed by the Engr-in-Charge.
M & L for Brick work with fly ash brick, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 using old size brick complete all as specified and directed.
M & L for brick work with fly ash bricks, straight or curved on plan to any radius, built in cement mortar 1:4 as in half brick thick walls using old size brick complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing rubbish to outside MD land complete all as specified and directed
M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and fair without using extra cement complete all as specified and directed.
M & L for rendering 5 mm thick in cement mortor 1:3 on concrete surfaces as in ceilings and finishing surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with integral water proofing compound with weight of cement in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).
M & L for Cutting / Chipping the spalling concrete surfaces of Slabs, Beams, Columns, Fins, Facias, Parapets & Chajjas etc. and trimming, cleaning the surfaces of any thickness to receive Guniting / Plastering, preparing surfaces and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved Bonding Agent / Epoxy Treatment in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions and providing pressure Guniting averaging 25mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 duly modifying the mortar with and including suitable bonding agent of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. @ 5% of weight of cement for sides and soffits of Slabs, Beams, Columns, Fins, Parapets Facias & Chajjas etc., finishing the top surface even and smooth without using extra cement conforming to proper geometrics including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material out of MD land complete all as specified and as directed.
M & L for Non shrink Micro concrete (Rendroc RG[S] of Fosroc), mixed with graded coarse aggregate n.exc 12mm in size in propoprtions as per the manufacturer's instructions, laid in average thikness of 80-100mm for structural members with and including leak proof form work coated with reabol mould release agent, applying one or more coat of Nitozinc primer on the reinforcement steel after cleaning steel surfaces and applying epoxy based nitobond EP for bonding new or old surfaces including providing necessary double scaffolding and removal of the same on completion of the work complete all as specified and directed. (Note: Measurement shall be considered for circumference at centerline of core thickness) (Make: M/S Fosroc or equivelant of make M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd.)
Complete removing the plants from the surfaces of the building with complete roots, applying recommended chemical to prevent further growth as directed, making good the disturbed surface with cement mortar 1:3 and applying the same surface finish of the existing surface and finished to match with the surrounding surfaces including removal of debris etc., out side the premises complete all as required complete all as specified and as directed.
M & L for preparing newly plastered surfaces of walls, etc and applying three coats of white wash complete all as specified and directed.
M & L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M & L for preparing newly plastered surfaces of internal walls, etc by "Vacuum based sandng machine" and applying two coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification over a coat of alkali resistant primer by Auto Roller machine and over one or more coats of wall care putty to a smooth surface complete all as specified and directed. (Note: Multipurpose mixer shall be used for uniform and proper mixing of putty)
M & L for preparation new external surfaces of wall etc "Vacuum based sandng machine" and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces by "Auto Roller" machine complete all as specified and directed.
M & L for preparing old decorated surfaces of walls, etc including cornices by bromming down or by steel wire brushing, scrapping down smokes soot, moulds, moss and efflorscent salt and treating oil and greasy spot and applying one coat of white wash complete all as specified and directed.
M & L preparing old decorated surfaces of ceiling, etc including cornices by bromming down or by steel wire brushing, scrapping down smokes soot, moulds, moss and efflorscent salt and treating oil and greasy spot and applying two coats of white wash complete all as specified and directed.
M & L for preparing old plastered surfaces of walls by complete removal of existing treatment "Vacuum based sandng machine" and applying two coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification over a coat of alkali resistant priming coat by Auto Roller machine over one or more coat of wall care putty complete all as specified and directed. (Note: Multipurpose mixer shall be used for uniform and proper mixing of putty)
M & L for Preparation of old painted wood and wood based surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed.
M & L for preparation old decorated external surfaces of wall, chajja, facia etc by "Vacuum based sandng machine" after complete removing old paints by mechanical scrubber without disturbing the plastered surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces by "Auto Roller" machine over one or more coats of wall care putty to a smooth finished surface complete all as specified and directed. (Note: Multipurpose mixer shall be used for uniform and proper mixing of putty)
M & L for Writing letters or figures (Block ,Roman, Italic or Indian) n. exc 30 cm height with synthetic enamel paint complete all as specified and directed.
M & L for Writing stops, commas, short lines , dashes, hyphens, brackets, etc with synthetic enamel paint complete all as specified and directed.
Dismantling 100mm bore, cast iron or reinforced concrete drain pipes jointed in cement mortar and taking out of trenches if required and as directed.
Dismantling 75mm bore, cast iron or reinforced concrete drain pipes jointed in cement mortar and taking out of trenches if required and as directed.
S & F 110 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints fixed to wall, etc with all necessary fixing arrangement complete all as specified and directed.
S & F 75 mm bore, PVC (SWR), Soil, waste and vent pipes, single socketed in any length with rubber ring joints fixed to walls, etc complete all as specified and directed.
S & F 110 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, etc complete all as specified and directed.
S & F 75 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, etc complete all as specified and directed.
S & F 110 mm bore, PVC (SWR) bends of any radius complete all as specified and directed.
S & F 75 mm bore, PVC (SWR) bends of any radius complete all as specified and directed.
S & F 110 mm bore, PVC (SWR) bends of any radius with oval access door complete all as specified and directed.
S & F 75 mm bore, PVC (SWR) bends of any radius with oval access door complete all as specified and directed.
S & F 110mm bore, PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
S & F 75mm bore, PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
S & F in repair 75 mm bore, PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
Taking up or down 15mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
Taking up or down 20mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
Taking up or down 25 or 32 mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
Taking up or down 40 or 50mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
Supply, laying, connection and testing, 20mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed
Supply, laying, connection and testing, 25mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed
Supply, laying, connection and testing 40mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed
Supply, laying, connection and testing, 50mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed
S & F in repairs, 15 mm bore, bib taps, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F in repairs, 15 mm bore, Stop valves, cast copper alloy, chromium plated with long shank and cup, concealed type, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S & F in repairs, CP, Wall Mixer with Provision For Overhead Shower with 115mm Long Bend Pipe On Upper Side, Connecting Legs & Wall Flanges complete all as specified and directed. (Make : JAQUAR, Cat No . OL-6273UPR or equivelant of make as per list of manufacturer's)
S & F in repairs, 15 mm bore, Stop valves, cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S & F in repair 15 mm bore, angular stop valve, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F in repair 125 mm size, shower rose, brass chromium plated, swival type, complete all as specified and directed.
S & F in repair 25 mm bore, gun metal, globe or Gate valves with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S & F in repairs, 50 mm bore, gun metal Gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S & F in repairs, 15mm bore, PVC connection pipe 600mm long with PTMT nuts at both ends complete all as specified and directed.
S & F in repairs Soap dish of standard size, stainless steel, fixed in walls with plugs & chromium plated brass screws complete all as specified and directed.
S & F in repairs, Towel Ring of brass chromium plated fixed to wall and including Chromium plated brass screws and wooden/plastic cleats etc complete all as specified and directed.
S & F in repairs 20 mm bore, Brass chromium plated, tubular towel rail, D type, 60 cm long between flanges with brackets complete all as specified and directed.
S & F in repairs, vitreous China wash down water closet pan (pedestal pattern), white, including connection to outgoing drain and flushing pipe, anti syphonic pipe with seat and cover complete but excluding flushing cistern & flush pipe including making good damaged/disturbed surfaces complete all as specified and directed.
S & F in repairs, 10 litre capacity, PVC valve less syphonic action type, flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and directed.
S & F in repairs, vitreous China wash basin, size 550 x 400mm, white, flat back including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specified and directed.
S & F in repair 32 mm dia Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
S & F in repairs, 15 mm bore, pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S & F in repairs, 32mm dia flexible PVC waste pipe of length not less than 800mm for wash basin/sink etc complete all as specified and directed
Taking down chowkats or frame, n.exc 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and directed.
Taking down chowkats or frames, exc 1.5 but n.exc. 4 Sqm in each with shutter (without taking off shutter from the frame) complete all as specified and directed.
S & F solid PVC door frames of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed.
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, complete as per specification and drawing and as directed.
S & F PVC solid ventilators with frame size 55x47mm with wall thickness 5mm made out of extruded PVC sheet, mitre cut at corners and jointed with 2 Nos, 150mm long brackets of 15x15mm MS Square tube, the two vetted profiles are to be reinforced with 19x19mm MS square tube, 50% of bottom portion shall be fixed with 4mm thick pin headed glass and balance 50% of top portion shall be fixed with 4mm thick pin headed glass lowers and covered with 0.36mm dia stainless steel wire mesh at top portion including necessary PVC beading with screw and 3 Nos 12mm dia MS guard bars fixed in ventilator frame including two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer to MS guard bars and necessary fixtures complete all as specified and as directed.
S & F Powder coated (minimum 50 micron) Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. (Note : (i) Thickness of aluminium section shall not be less than 1.5 mm).
S & F Powder coated (minimum 50 micron) Anodised aluminium window and ventilator shutters, sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. and anodised aluminium fittings and suitable size of handle complete all as specified and directed.
S & F Well seasoned 2nd class hard wood plain, solid, straight chowkat and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
S & F 35 mm thick, 2nd class hardwood, factory made, Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S & F 35 mm thick, factory made, glazed/skeleton shutters with first class hard wood, open rebated and prepared to receive glass, gauze, etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass, etc complete as specified and directed . Sizes of members of shutters as specified in SSR Part I complete all as specified and directed
S & F 35 mm thick, factory made Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
M & L for plain cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) for embedding holdfast, bed block, cills, etc including necessary form work complete all as specified and directed.
S & F mild steel bands, straps, supports or stays of rain water, ventilating pipes including bolts, hooks (stay) for large gates, hook and pintel hinges, clamps, hold fasts, wall ties, flat iron fillets for securing wire mesh, wind tie, fan hook and similar work including necessary drilling bolting or riveting etc conforming to Fe – 290 Gde E – 165 complete all as specified and as directed.
S & F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S & F 5 mm thick, sheet glass, ordinary quality and glazing with wooden beading/rubber beading exceeding 0.5 Sqm in each pane complete all as specified and as directed. (Note: The cost of rubber beads included with the unit quoted rate of respective aluminium shutter)
S & F 125 mm long, stainless steel butt hinges fixed with stainless steel hinge pin etc complete all as specified and directed.
S & F 100 mm long, stainless steel butt hinges fixed with stainless steel hinge pin etc complete all as specified and directed.
S & F 150 mm long, Aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
S & F 100 mm size, Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S & F 150 mm size, extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S & F Aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sections or cast aluminium alloy, length of bolt of 300 mm complete all as specified and directed.
M & L for Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed.
S & F in repair Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S & F Floor door stopper of aluminium alloy body and tongue, anodised, 150 mm overall length of cover plate with hard drawn steel spring, fixed in floor complete all as specified and directed.
S & F in repairs 25 mm dia, stainless steel, fancy curtain rod, heavy duty, 2 to 3mm thick including stainless steel bracket of superior quality for each opening/door/window etc complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails etc complete all as specified and directed.
S & F 18/19 mm thick, plywood, grade BWR, type BB, fixed with screws to timber frame work in partition/ cup baord/ wall panelling, etc complete all as specified and directed.
S & F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised, 40mm width of flape when open complete all as specified and directed.
S & F 150 mm size, stainless steel designer handle, fabricated type polished complete all as specified and directed.
S & F magnetic catch with striking plate, 40mm size superior quality complete all as specified and directed.
S & F 82mm size, night latch with 7 levers with two keys, brass body, polished bright; vertical type with brass knob or lever handle and fixed complete all as specified and directed.
M & L for post construction Antitermite treatment Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron.complete all as specified and directed.
M & L for post construction Antitermite treatment by treating At points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and directed.
Taking down, Resecuring or easing & adjusting and refixing in the same opeing shutter of any description exc 1 Sqm but n. exc 2 Sqm each including refixing builder's hardware as required and replacement of screws etc complete all as specified and directed.
S & F Second class hardwood, Small fittings such as brackets of any type, latch & hinge blocks, shaped door & window stops and the like, including all necessary labours; articles n.exc. 200 cu.cm each complete all as specified and directed
Supply only 50 mm size, butt hinges, medium weight, stainless steel complete all as specified and directed.
M & L for PVC corner beading, half round, n.exc 15mm girth fixed to tile junctions complete all as specified and directed.
S & F in repair 15 mm bore, Hand Shower (Health Faucet) (ABS Body) with 8mm Dia, 1.2 Meter Long Spirochrome flex tube & Wall Hook complete all as specified and directed. (Make: Jaquar Cat No. ALD-587 or equivelant of make as per List of manufacturer's)
S & F in repairs, 15mm bore, bib taps, two way, fancy type cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. (Make: Jaquar Cat No. CON-041KN or equivelant of make as per list of manufacturer)
Providing and fixing in repairs Powder coated Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge complete all as specified and directed.
Taking down carefully unserviceable aluminium/copper point wiring (light, fan, socket or power) complete, (fitting such as switches, ceiling roses, pendants, regulators, sockets, etc to be measured separately if found serviceable), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Taking down unserviceable main switches, DBs, bus bars chambers any capacityincluding all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and directed.
Taking down unserviceable sub-main wiring (any numbers of cable) with rigid PVC/steel conduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and directed.
M & L for Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore (Minimum) medium grade (ISI marked) concealed type including metal GI boxes of suitable module including modular white cover plate of suitable module for fixing modular type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed, for one light/exhaust fan/fan point/call bell controlled by one way switch. (Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface. (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one)
All as per item No. 125 above but for One light point controlled by two Nos two way switch complete ditto
All as per item No. 125 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto
All as per item No. 125 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto
All as per item No. 125 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 4 sqmm multistranded FRLS (ISI marked) and 4 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto
S & F switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed.
S & F Modular socket outlet 6A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed.
S & F switch modular single pole Two way 6 amp 240 volts,1 module complete all as specified and as directed.
S & F switch modular single pole one way 16 amp 240 volts,1 Module complete all as specified and as directed.
S & F Modular socket outlet 6A/16A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed.
S & F modular bell push 6 amp 240 volts1 module,complete all as specified and as directed.
S & F steped type modular fan regulator ,100/120 W 1/ 2 module complete all as specified and as directed.
S & F in repairs switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed.
S & F in repairs switch modular single pole one way 16 amp 240 volts,1 Module complete all as specified and as directed.
S & F in repairs Modular socket outlet 6A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed.
S & F in repairs Modular socket outlet 6A/16A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed.
S & F in repairs steped type modular fan regulator ,100/120 W, 1/ 2 module complete all as specified and as directed.
Taking down carefully by unscrewing from boards/outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse) complete all as directed.
Fixing only serviceable light fittings any type including connecting up complete all as specified and directed (Note: Old serviceable light fittings as obtained from serial Item No 142 here -in-before shall be re-used).
S & F Vertical TPN DB double door for provision for four pole MCCB upto 160 A incommer 4 way 12 outgoing with IP 43 protectioncomplete all as specified and as directed. (Make : Legrand cat part No. 5077 45 or equivelant of make as per List of manufacturer's)
S & F Distribution Board, SPN 12 Way, 240V, Double door with IP 43 protection, IK 09 complete all as specified and as directed. (Make: Legrand cat part No. 5076 12 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve, complete all as specified and as directed (Make: Legrand cat part No. 4085 87 to 95 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB SPN 6-32A Amps, 240 Volts, 10KA, C Curve complete all as specified and as directed (Make: Legrand cat part No. 4086 14 to 17 or equivalent make as per List of Manufacturer's)
S & F MCCB 415 Volt 16 KA, 4 Pole, 63 Amps Capacity complete all as specified and as directed . (Make: Legrand Cat Part No. 4200 13 or equivelant of make as per List of Manufacturer's)
M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one)
M & L for Sub main wiring with 2 runs of Single core 4 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 4 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- (i)Two runs of 4 sqmm and one runs of 4 sqmm cable as earth wire and one run of conduit shall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one )
M & L for Sub main wiring with 2 runs of Single core 2.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (Medium grade) with all conduit accesories and fittings along with 1 run of single core 2.5 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- (i) Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth wire and one run of conduit shall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one )
M & L for Sub main wiring with 2 runs of Single core 1.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 1.5 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- (i) Two runs of 1.5 sqmm and one runs of 1.5 sqmm cable as earth wire and one run of conduit shall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one)
Taking down electric meter upto 25 Amps from its existing position and refixing and connecting up in the same position after carryout necessary repair/painting work to the board complete all as specified and directed.
S & F in repairs stationary louvers suitable for exhaust fan of 300mm sweep made out of powder coated aluminium anodised sheet of Min 1mm thick with non removable blades fixed permanantly at 45 degree angle for protection from rain including aluminium wire mesh of suitable size for bird control Complete all as per the existing specification and as directed. (Note: Louver has to fixed upto sixty metre height multistoried building. The unit quoted rate shall deemed to be inclusive of necessary scafolding and safety measure for fixing of louver upto sixty metre height. No extra claim on this account shall be entertained later on)
M & L Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth strip of size 32x6mm by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, with 40 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.
M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs Test terminal box of size 175x150x100mm made out of 2mm thick hot dip galvanised sheet drilled and screwed including 4 nos 125mm long hexogonal head screwed with test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and as directed.
S & F in repairs Aluminium strip of size 25x3.15 mm for lightning conductor (roof conductors)/down conductors) laid in trench/floor including necessery clamps, nuts, bolts and hylem sheet block complete all as specified and as directed.
S & F in repairs earth continuity conductor or main earthing lead with galvanised iron strip of size 32 x 6 mm, fixed to wall on batten or recesses or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required complete all specification and directed.
S & F in repair Air termination, single pointed aluminium rod 12mm dia and 300mm long fixed to overhead reservoir as in lightening protection with necessary connections to earthing etc complete all as specified and directed.
S & F Concealed sheet metal enclosure with socket plug top and MCBs having single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20Amp 240V, B-curve complete all as specified and as directed.
Supply, install, testing & Commissioning, 5 STAR rated Hi wall split type air conditioner with indoor and outdoor units complete with cordless remote control unit and with in-built advanced air filters for better indoor air quality with latest inverter technology, having eco friendly refrigerant gas, copper condenser coil, EER 4.5 or above of capacity 1.5 TR, summer cool, Inverter compressor, automatic 2D swing copper condenser, BLDC motor, necessary copper pipe connections including cutting, bending, brazing, insulation on pipes etc, PVC drain pipe, electric connection in between indoor and outdoor unit with suitable size of PVC insulated, multi-stranded copper cable complete with all fixing accessories such as bracket etc complete all as specified and directed. (Note: The unit rate quoted above shall deem to be inclusive of the following accessories/works:- (i) Powder coated MS fixing brackets of suitable size for outdoor and indoor units at any height (ii) Copper tube of suitable size upto 2m each (iii) Drain pipe made of UPVC pipe of pressure rating 10Kg/Sqcm of 20mm dia upto 2m each (iv) 4 core, 4 Sqmm PVC insulated and PVC sheathed, heavy duty multi-stranded copper conductor cable, 1100 Volts, FRLS grade as required for connecting indoor and outdoor unit (v) Drilling hole on brick wall to facilitate routing of copper pipe, drain pipe and cable from indoor unit to outdoor unit (vi) Sealing hole from outside from outside with white cement and making good disterubed surfaces as per the existing one (vii) Pressure testing, cooling performance check and product demonstration (viii) M & L for fixing remote control in wall complete)
S & F voltage stabilizer for automatic operation,, single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output of 230V with accuracy of +/- 2.5% variation of capacity 4.0 KVA complete all as specified and directed.
S & F copper tubing 24 SWG of size 5/8" dia suitable for suction/discharge line of Acs alongwith tubular insulation suitable for 1.5 TR Cassate AC and to be enclosed with and including PVC duct of suitable size complete all specified and as directed.
S & F copper tubing 24 SWG of size 7/8" dia suitable for suction/discharge line of Acs alongwith tubular insulation suitable for 1.5 TR Cassate AC and to be enclosed with and including PVC duct of suitable size complete all specified and as directed.
S & F 20 mm bore, Unplasticized PVC pipes of pressure rating 10 kgf/sq. cm fixed to walls, laid in floor etc complete all as specified and directed.
K SATYANARAYANA ENTERPRISES
N Sydeswara Rao
P SRINIVASA RAO
M/s KAMADHENU ENGINEERING CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .