Superintending Engineer
SE ECTC SLDC Campus UPPTCL, Lucknow
Annual Civil Maintenance and Repair work at Various Sub Station under Electricity Transmission Circle Bareilly
2026_UPCTL_1107690_1
97/ECTC(L)/2025-26
Open Tender
Civil Works
Percentage
730 days
SE ECTC SLDC Campus UPPTCL, Lucknow
Please refer Tender documents.
2 documents required · 2 mandatory
₹11,800
Superintending Engineer, E.C.T.C. Lucknow
₹8 L
25 Mar 2026
23 Jan 2026
6 Mar 2026
23 Jan 2026
3 Mar 2026
23 Jan 2026
ANNUAL MAINTENANCE & REPAIR.WORK AT 400/220/132 KV SUB STATION UNDER ELECTRICITY TRANSMISSION CIRCLE BATREILLY (Rate as per Current SOR 05/2024 based on Issued DSR- Group 02) ( District Bareilly under ETC, Bareilly)
ANNUAL MAINTENANCE & REPAIR.WORK AT 220/132 KV SUB STATION UNDER ELECTRICITY TRANSMISSION CIRCLE BATREILLY (Rate as per Current SOR 05/2024 based on Issued DSR- Group 05) ( District Budaun & Pilibhit under ETC, Bareilly)
BILL OF QUANTITY
ANNUAL MAINTENANCE & REPAIR.WORK AT 400/220/132 KV SUB STATION UNDER ELECTRICITY TRANSMISSION CIRCLE BATREILLY
(Rate as per Current SOR 05/2024 based on Issued DSR- Group 02) ( District Bareilly under ETC, Bareilly)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..Group C ( DSR EH.-1.10.3 )
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.( DSR EH.-1.12)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire ( DSR EH.-1.14.2 )
Supplying and fixing of 25 mm of medium class PVC conduit along with accessories in surface/recess including junction box,cutting the wall and making good the same in case of recessed conduit as required. 25 mm( DSR EH.-1.21.2 )
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole ( DSR EH.-2.10.1 )
Grant Total
Conditions:
1. All civil work shall be executed according to the approved drawings of UPPTCL.
2. The quantities in BOQ are tentative and may vary up to any extent or be deleted as per the requirement at site.
3. The above quantities shall be executed as per the the list of sub stations (Annex. B) attached, with the maximum expenditure at a particular sub staion as indicated in the list. Any directive given by top officials on work as be obligation to firm. Engineer of the Contract (EOC) shall have right to delete or add sub station in the list enclosed.
4. All civil work shall be carried out as per UPPWD/UPPTCL specification.
5. Rates in BOQ are exclusive of CGST,SGST.Labour tax shall be borne by contractor.
6. Pozzlona Portland cement confirming to IS 1489(Part 1) 1991 of approved quality like ACC,Ultra Tech,Birla or equi.shall only be used.
7. Overweight steel section within tolerance shall be measured at standard weight and underweight steel section within tolerence shall be measured at actual weight.
8. In case any change in Bill of Quantity is suggested by higher authority that will be binding on the contractor.The agreement shall be executed on the approved Bill of Quantity only.
9. 60% amount of bricks recovered from dismentaling quantity will be treated as brick and shall be isued at rate Rs. 4769.00/thousand + GST to firm /contractor.
10. 30% amount of bricks recovered from dismentaling quantity will be treated as brick bats and shall be issued at the SOR i.e rate Rs. 508.00/CuM + GST to firm /contractor.
11. The amount of steel recovered from dismentaling will be recovered (if any) shalll be issued at the rate Rs. 20.00/Kg + GST to firm /contractor.
12. Replaced CP Bib cock/ piller cock/ brass bib cock shall be recovered @ Rs. 25/- each. + GST to firm /contractor.
13. Old door and windows, shutter with chaukhat shall be recovered @ Rs. 70/- per sqmt. + GST to firm /contractor.
14.Performance Guarantee shall be applicable as per GO 622/23-12-2012-2 Audit/08 dt 08 June 2012.adopted by UPPTCL BOD dated 27.06.2017
BILL OF QUANTITY
ANNUAL MAINTENANCE & REPAIR.WORK AT 220/132 KV SUB STATION UNDER ELECTRICITY TRANSMISSION CIRCLE BATREILLY
(Rate as per Current SOR 05/2024 based on Issued DSR- Group 05) ( District Budaun & Pilibhit under ETC, Bareilly)
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.(DSR 2.31)
Providing and laying in position cement concrete of 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth level. ) (DSR 4.1.8)
Providing and laying cement concrete 1:1½:3 in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:(DSR 4.2.2)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22.6)
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile (DSR 11.21.1.1)
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) sand) Acid and alkali resistant tile (DSR 11.21.2.1)
Providing and fixing ridges and hips in fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete DSR 12.12.1)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.(110 mm diameter) (DSR 12.41.2)
Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required.(DSR 12.8)
White washing with lime to give an even shade :New work (three or more coats) (DSR 13.37.1)
Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution. (DSR 13.53.1)
Painting with aluminium paint of approved brand and manufacture to give an even shade .Two or more coats on new work. (13.63.1)
Two coats Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.(DSR 13.83.2)
Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface). (DSR No13.111.1)
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - chargeNominal concrete 1:4:8 or leaner mix (i/c equivalent design mix).(DSR No15.2.2)
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm. (DSR 15.23.1)
Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead. (DSR 15.36)
Welded steel wire fabric of required width having rectangular mesh painted with two or more coats of enamel paint of approved shade over a coat of primer (Priming & Painting to be paid for separately). (DSR 16.15.2)
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 DSR No. 16.78.2
Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) :150 mm diameter class II (DSR No. 18.31.3.2:)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) (DSR 21.3.2)
Supply & installation of electrical control panel of L&T / Havells or equivalent make for submersible pump / pumpset containing contractor relay condenser. for 1 HP pump set single phase (DSR NSI 54-a)
Supply & Installation of submersible pump of K.S.B/ CALAMA. or eqt. make including cost of labour, T&P and material required for completion of work.1 HP outlet 32 mm dia. or more, Head 78/30,Discharge 1100/2800 LPH (DSR NSI 55-a)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..Group C ( DSR EH.-1.10.3 )
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.( DSR EH.-1.12)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire ( DSR EH.-1.14.2 )
Supplying & Drawing following 3x2.5 sq. mm sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required ( DSR EH- 1.17.12)
Supplying and fixing of 25 mm of medium class PVC conduit along with accessories in surface/recess including junction box,cutting the wall and making good the same in case of recessed conduit as required. 25 mm( DSR EH.-1.21.2 )
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole ( DSR EH.-2.10.1 )
Conditions:
1. All civil work shall be executed according to the approved drawings of UPPTCL.
2. The quantities in BOQ are tentative and may vary up to any extent or be deleted as per the requirement at site.
3. The above quantities shall be executed as per the the list of sub stations (Annex. B) attached, with the maximum expenditure at a particular sub staion as indicated in the list. Any directive given by top officials on work as be obligation to firm. Engineer of the Contract (EOC) shall have right to delete or add sub station in the list enclosed.
4. All civil work shall be carried out as per UPPWD/UPPTCL specification.
5. Rates in BOQ are exclusive of CGST,SGST.Labour tax shall be borne by contractor.
6. Pozzlona Portland cement confirming to IS 1489(Part 1) 1991 of approved quality like ACC,Ultra Tech,Birla or equi.shall only be used.
7. Overweight steel section within tolerance shall be measured at standard weight and underweight steel section within tolerence shall be measured at actual weight.
8. In case any change in Bill of Quantity is suggested by higher authority that will be binding on the contractor.The agreement shall be executed on the approved Bill of Quantity only.
9. 60% amount of bricks recovered from dismentaling quantity will be treated as brick and shall be isued at rate Rs. 4769.00/thousand + GST to firm /contractor.
10. 30% amount of bricks recovered from dismentaling quantity will be treated as brick bats and shall be issued at the SOR i.e rate Rs. 508.00/CuM + GST to firm /contractor.
11. The amount of steel recovered from dismentaling will be recovered (if any) shalll be issued at the rate Rs. 20.00/Kg + GST to firm /contractor.
12. Replaced CP Bib cock/ piller cock/ brass bib cock shall be recovered @ Rs. 25/- each. + GST to firm /contractor.
13. Old door and windows, shutter with chaukhat shall be recovered @ Rs. 70/- per sqmt. + GST to firm /contractor.
14.Performance Guarantee shall be applicable as per GO 622/23-12-2012-2 Audit/08 dt 08 June 2012.adopted by UPPTCL BOD dated 27.06.2017
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.46 MB
Tendernotice_2.pdf
PDF • 0.59 MB
BOQ_2044359.xls
BOQ • 0.52 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .