Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.8 LAccepted-AOC VILLAGE P O MANSIMBLE TEHSIL PALAMPUR DISTRICT KANGRA HP | KANGRA | HIMACHAL PRADESH | 175013 | L1 | Accepted-AOC accept | |
| 2 | L2₹31.8 L+₹6.0 L (23.3%)Rejected-AOC | L2 | Rejected-AOC accept | |
| 3 | L3₹31.9 L+₹6.1 L (23.6%)Rejected-AOC R O SUJANPUR TEHSIL DISTT HAMRIPUR | L3 | Rejected-AOC accept |
Tender Value
₹17.8 L
EMD Value
₹34,215
Closing Date
5 Oct 2020, 5:00 pmClosed
Executive Engineer JSV Division Thural
O/O The Executive Engineer JSV Division Thural
Providing LIS Kuhan Dol in Tehsil Jaisinghpur Distt. Kangra HP
2020_HPIPH_41163_1
THL-KNG05-729 (9846-92 dated 28.09.2020)
Open Tender
Civil Works - Lift Irrigation Schemes
Item Rate
180 days
Providing LIS Kuhan Dol in Tehsil Jaisinghpur Dist
Please refer Tender documents.
10 documents required · 10 mandatory
₹400
₹34,215
Yes
12 Apr 2021
28 Sept 2020
6 Oct 2020
28 Sept 2020
5 Oct 2020
28 Sept 2020
Amount
Submersible Pumping Machinery for Stage 1st.Supply of submersible pumping set of KSB Model KRTE 150-401 make conforming to BIS :8034 - 1978 ( letest with upto date ammendments ) fitted with bronze impellers / suitable alloy directly coupled to squirrell case electric induction motor of same make as that of pump conforming to BIS 9283-1979 ( latest with upto date ammendments ) and totally water proof for submersible duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearings & provided with steel thrust bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard,errection clamps,chips & depth gauge etc.-The pump shall be suitable for operation on data given below :-2 Nos 2 x 40 HP=80 HP (Pump,Motor, Coupling & Base Plate Received)
Make and Model:-KSB Make Model KRTE 150-401,KW OF Moter 62 KW,RPM 1450,Power observed at duty point 40KW,Discharge at Dilivery point 66.60 LPS,Impeller size 386 mm,Efficienct at duty point 62%,Duty head 39.35 mtr.A SITE CONDITIONS :-I,Location of site:-The site is located at a distance of 48 Kms from Palampur Maranda Railway station Thakurdwara Bheri Balakrupi Road Site is located at 120 Kms from Pathankot, & 500mtrs by head load.ii,The altitude of place in which 700 Metres above MSL.the motor is intended.iii,Type of current :- AC three phase supply with freqency of 50 cycles per second.,iv, Rated Voltage :-415 V = 10%(-) 25% ,v,Type of Water & its source. Raw water of River Beas,vi,Charactrstics of water :- a) Temperature 20 C b) Turbidity PPM, c) Hardness Mg./ Litres (as Ca Co3 ) d) pH 7.2 f) others e) Total solids. Mg / lit.,vii,Depth of well :- Mtrs.,viii,L.W.L in well/ Sump well:- mtrs.,ix,Max. draw down :- mtrs.,x,Center line Level of Pump 586 mtrs.,xi,Discharge level of highest point 621.15 mtrs. ,xii,No. of pump required :- 2 Nos of 40 HP ( One will act as stand by),xiii,Capacity :- 40.53 LPS for each pump ( One will act as stand by),xiv,Static head in mtrs. 35.15 meters,xv,Total head in metres 39.35 meters,xvi,Length of Rising main :-150 meters,xvii,Dia of Rising main :-300 mm dia,xvii,No of pumping Hrs. per day:- 16 Hrs.,xix,Limits of pump operation :- (-) 25* to ( + ) 10*of total head.,xx,HP of motor Drive unit :- Required BHP of pump at ( -) 10* & 25* of total head, BHP with following margins multiplying factor at, duty point. Whichever is higher, a) Upto 2 HP = 1.5 d) 10 to 20 HP 1.2, b) 2 to 5 HP = 1.4 e) 20 to 100 HP 1.15, c) 5 to 10 HP = 1.3 f) above 100 HP 1.10,xxi,RPM of Pumping Sets:- to be specified by the tender,xxii,Test Run :- 20 hrs. continueously for 7 days.
Supply of suitable oil immersed star delta starter of standared make such as MEI/Jyoti/Kilburn/Siemens conforming to BIS 8544- 1979 Latest with upto date ammendments fof squirrel cage/ slipering motor mounted on pannel board with magnetic type over load release and dish pot time log under voltage release with initial oil filling.
Providing M.S sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height & size ISA 65 X 65 X 6 mm,duly painted comprising and capable of mounting the following accessaries with all internal electric connections.The drawing of panel board shall be subject to appr-oval of the Engineer-in-Charge.Note :- The drawing of panel board shall be subject to approval of Engineer -in-charge. 1 Nos
ICTP switches 100 amp with HRC fuses of Kilburn / L&T/ Siemens / Standard / Havells make and having capacity 30 % extra of operational rating of motor as per BIS 4064-1978 with up to date ammendments immediately after the power meter of HPSEB .2 sets
Bushbar chamber having three copper bars of suitable rating for full length 3 live phases and one copper bar of half reating of half rating of full length for natural conforming to BIS 8084 -1976 and 11353 -1985 read with 5578 - 1985 all latest with upto date ammendments. 1 nos
MCB of suitable capacity of Kilburn / L&T / MEI / standard/ GEC make on incoming feeder for pumping sets conforming to BIS 2516 -1985 ( latest edition ) with neutral linked under voltage release. 1 nos
Three phases indicator lamps complete with toggle switches for individual motors conforming to BIS 3452 part I&II latest with upto date ammendments. 2 set
Hour run meter of reputed/ approved make of four digit capacity conforming to BIS - 722 (latest edition). 2 nos
Supply of Kirloskar/ Kilburn / IVC / Fouress/ Gled /BHEL /Leader/ Kartar make Cast iron double flanged sluice valve ( to be provided on delivery side ) of size one size higher than the delivery size of pump and capable of with standing nominal seat pressure of 10 Kg / cm2 class PN-1.0 780-1984NOTE:-The C.I sluice valve shall conform to BIS 780 -1984 for 50 to 300 mm dia & BIS:2906-1984 for 350 to 1200 mm dia ( latest adition ) However I f seat pressure exceeds t he l imits prescribed in above mentioned BIS. than It shall be of cast steel conforming to class ASA-150 for seat pressure upto 21 Kg/ cm2 or class ASA-300 for seatpressure 10 Kg/cm2 as BSI 5312-1984 PART 1
Supply of Kirloskar /Kilburn /IVC/ Fouress /Gled /BHEL/Leader /Kartar of suitable size cast iron double flanged swing check type reflux valve having bye - pass arangement ( to be provided on delivery side ) of size one size higher than the delivery size of pump & shall be suitable for with standing nominal seat pressure of 21kg/cm2 of class ASA -150 as per BS-1868-API(600).
Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex / Gloster/ Grandlay make Conforming to BIS: 1554 ( Part-I ) 1988 latest with upto date ammendments of suitable size for the pump sets offered ( one cable carrying all three phases ) including all other Electrical equipment / accessories such as thimbles,flexible pipes, solder ,nuts & bolts, cable glands etc. laid in pipes or tranches under floor.The type size & make will be subjct to approval of HPSEB authority. In case of non acceptance by HPSEB authoritties It shall have to be replaced by the tenderer free of cost.
a) On supply side of 3-1/2 core( From HPSEB meter to Switch & Starter = 70 mm2
b) On motor side 3 core ( From Switch & Starter to Motor ) = 50 mm2
Providing & laying double loop earthing and copper plate 600 X 600 X 3mm thick electrode complete with material such as charcoal & common salt, G.I pipes, thimbles,nuts & bolts, digging of pits G.I wire & 25X3mm copper strips as per BIS : 3043-1987 latest with upto date ammendments for above motors & other electrical equipment.Note:- The strip size shall be 20x3 upto 18.5 KW,25x3 for 18.5 to 37 KW , 25x5 for 37 to 55 KW & 32x5 beyond 55 KW.
Supply & errection of floor power factor Shunt Capacitor conforming to BIS 2834-1986 latest with up to date ammendments BHEL / GEC / Machneil / Magger / Bajaj make to raise the prevailling power factor at site to 0.95 for direct connection to induction motor individually, of required KVAR according to HP of motor offered also including L & T / Standard / Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses ( Range to be specified by the tenderer.) 2 sets or 23 KVAR
Supply of standared make 100 mm dia Square dial pressure gauge of suitable range Fiebeg/ Bourden/ Precision make complete with all accessories such as stop cock, copper tubing etc.conforming to BIS 3624-1987 latest with upto date ammendments.
Providing and laying Column assembly of MSERW pipe considering site requirement and having appropriate size in accordance with the delivery size of pumping set. The pipe shall conform to relevent BIS codes & capable of with standing the field test pressure equal to 1.5 times the operating pressure including all type of fittings such as bends, tapers /reducers, flanges, rubber guskets 3 mm thick, nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer in charge.
MSERW Pipes 150 mm dia with flange table 11
MSERW Pipes 300 mm dia with flange table 11NOTE :-Actual laying to be done final drawings to be approved by the Engineer in charge.
Errection of all equipments from S.No. 1 to 4 & 6 including cost of tees, bends tapers & any other fittings required as per site conditions as per direction of the Engineer-in-charge.
Supply of horiozental spindle, horizental/radial split casing and suction(backfull out arrange-ments) singe/ double/ multistage centrifugal pumps or combination of pumps in series/parellel of standard make such as KSB/Mather & Platt/ Jyoti /Kirlosker/BE/ Maxflow/Beaconweir con- forming to BIS 1520-1980)Pump(Latest with upto date ammendments) read with BIS 9137- 1978 (latest edition) suitable for lifting Clear water of under mentioned charactristics with bronze (latest edition) suitable for lifting Clear water of under mentioned charactristics with bronze impeller / priming funnals, casing ring & shaft) motor of bronze ,shaft of steel grade ASA-410 with cast iron casing coupled directly through a flexible coupling on a common C.I./ Cast steel plate (base plate from the prinicipal manufacturer of pumping set) coupling squirrel cage screen protected drip proof electric induction motor of standard make such as Kirlosker /NGEF /Cromption /Siemen /Jyoti/ BHEL/GEC/ABB conforming to BIS : 325 - 1978 ) read with BIS : 900 - 1968 (latest with upto date ammendments) It should include the cost of bearings,nuts & bolts, painting etc., and shall be suitable for operation as per data given below:--2x120 HP=240 HP Pump,Motor,coupling 7 Base palte received)
Make and Model:-KSB Make and Model WL-125/7 STAGES BHP of Motor 120 HP RPM 1450,Discharge at Dilivery point 32.49 LPS,Impeller size,Efficienct at duty point 78 %,Duty head 174.37 mtr.A)SITE CONDITIONS :-,I,Location of site :-The site is located at a distance of 48 Kms from Palampur Maranda Railway station on Bheri Balakrupi road Site is located at 120 Kms from Pathankot, & 500 mtrs by head load.,ii,The altitude of place in whi 700 Metres above MSL.the motor is intended.,iii,Type of current :-AC three phase supply with freqency of 50 cycles per second.,iv,Rated Voltage :- 415 V = 10% (-) 25%,v,Type of Water & its source Raw Water from collection tank, vi,Charactrstics of water :-a) Temperature 20 C b) Turbidity NTU c) Hardness Mg./ Litres (as Ca Co3 )d) pH 7.2 f) others -------- e) Total solids. Mg / lit.,vii,Depth of well :- Mtrs.,viii,L.W.L in well/ Sump well:- 618.34 mtrs.,ix,Suction Head:- + ve mtrs.,x,Center line Level of Pump mtrs.,xi,Discharge level of highest point :-784.10 mtrs.,xii,No. of pump required :- 2 Nos. Pump.( one will act stand by),xiii,Capacity :-32.49 LPS for each pump (Two will act as stand by),xiv,Static head in mtrs.165.76 mtrs.,xv,Total head in metres 174.37 Meters,xvi,Length of Rising main :-1080 Metres,xvii,Dia of Rising main :- 300 mm dia,xviii,No of pomping Hrs. per day:-16 Hrs.,xix,Limits of pump operation :- (-) 25* to ( + ) 10*of total head.,xx,HP of motor Drive unit :- Required BHP of pump at ( -) 10* & 25* of total head BHP with following margins multiplying factor at duty point. Whichever is higher a) Upto 2 HP = 1.5 d) 10 to 20 HP 1.2, b) 2 to 5 HP = 1.4 e) 20 to 100 HP 1.15, c) 5 to 10 HP = 1.3 f) above 100 HP 1.10,xxi,RPM of Pumping Sets:- rpm ,xxii,Test Run :- 20 hrs. continueously for 7 days.,xiii,NPSH available.
Supply of suitable startor rotor of starter of 200 amp. Standared make such as MEI/KILBURN/L&T HAVELLS conforming to BIS 13947-1993 latest with upto date ammendments for squrrel cage/slippering motor mounted on pannel board with magnetic type over released and deshpot,timelog under voltage release with initial oil filling.
Providing M.S sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height & size ISA 65x65x6 mm, duly painted comprising and capable of mounting the following accessaries with all internal electric connections NOTE:.The drawing of panel board shall be subject to approval of the Engineer-in-Charge. 1 nos
ICTP switches 200mm with HRC fuses of Kilburn / Siemens / Standard / Havells/L&T make and having capacity 30 % extra of operational rating of motor as per BIS 4064-1978 with up to date ammendments immediately after the power meter of HPSEB .2 sets
Bushbar chamber having three copper bars of suitable rating for full length equal to width of the board of three live phases and one copper bar of half reating of full length for natural conforming to BIS 8084 -1976 and 11353 -1985 read with 5578 -1985 all latest with upto date ammendments. 1 no
Oil circuit breaker of 200 Amp.capacity of Standard Havells make as per BIS 2516-1985 with upto date ammendments with neutral linked under voltage release.1 nos
Three phases indicator lamps complete with toggle switches for individual phase conforming to BIS 3452 part I&II latest with upto date ammendments. 2 sets
Earth leakage circuit breaker of 200 Amp.capacity of Standard Havells make as per BIS 2516-1977 with upto date ammendments & of suitable range with which should have control box, , operating handle and trip / reset bush button on / off indicator, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with megnet thurmal release with metallic type etc., .It should also be fitted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end.1 no
Hour run meter of reputed make of four digit capacity conforming to BIS - 722 (latest edition) 2 nos
Change over switch of reputed make & suitable capacity. 1 no
Single phase Preventeor of reputded make & sutable capacity . 1 no
Three phase voltage monitor relay with all protection 7 usual indicators with electrical siern against single,phasing ,low voltage,high voltage & overloading & phase voltage difference as per BIS: 3842 (latest edition) of sauitable capacity.1 no
Supply of Kirloskar/ Kilburn /IVC/ Fouress/ Gled /BHEL /Leader / Kartar make of cast steel double flanged sluice valve 150 mm( to be provided on delivery side of size one dia higher to the delivery size of pump and capable of with standing nominal seat pressure of 21 kg/ cm2.of class ASA-150 conforming to BS 1414 (API 600).NOTE:- The CI sluice valve shall conform to BIS-780-1984for 50 to 300mm & BIS 2906-1984 for 350 to 1200mm dia (Latest edition). How ever if seat pressure exceeds the limit prescribed in above mentioned BIS than it shall be of cast steel conforming to class ASA-150 for seat pressure upto 21Kg/cm2 or Class ASA-300 for seat pressure 21 Kg/cm2 ASA 150 for seat pressure.
Supply of Kirloskar/ Kilburn / TVC / Fouress/ Gled / BHEL/ Leader Kartar make cast steel double flanged swing check type reflux valve 150 mm having bye-pass arrangement (to be provided on delivery side of Size one sizehigher than the delivery siize of pump and shall be suitable for with standing nominal seat pressure of 21 Kg./cm2 . The reflux valve shall be of class ASA-150 conforming to BS: 1868 ( API 600 )
Supply of Kirloskar /Kilburn / TVC/ Fouress/ Gled/ BHEL / Leader Kartar make cast steel double flanged swing check type reflux valve 300 mm having bye-pass arrangements & size equal to dia of Rising Main i.e. 300mm & shall be suitable for with standing nominal seat pressure of 21Kg./cm2 of class ASA-150 conforming to BS:1868( API-600) with upto date ammendments. seat pressure exceeds the limits prescribed in BIS 5312 then it shall be of cast steel conforming to class ASA- 150 for seat pressure upto 21Kg/cm2 or class-ASA -300 for seat pressure 52Kg cm2 as per BS 1869 (API-600).
Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex/ Grandlay/Gloster make conforming to BIS: 1554(P-1)1988 or latest with upto date ammend- ments of suitable size for pump sets offered (One cable 3 carrying all three phases) including all other electric al equipment /acessories such as thimmble flexible pipe solder,nuts & bolts & bolts cable4 gland etc., laid in pipes or trenches un der floor. The type size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
a. On supply side of 31/2 core(from HPSEB Meter to switch & Starter)=5mts. Of size120 mm2
b. On Motor side 3 core (From switch & Starter to Motor) =15 mts.of size 95 mm2
Providing & laying double loop earthing and copper plate 600 X 600 X 3mm thick electrode complete with material such as charcoal & common salt, G.I pipes,thimbles,nuts,Bolts,digging of pits G.I wire & copper strips of suitable size conforming to BIS : 3043-1978 latest with upto date ammendments for above motors & other electrical equipment. NOTE: The strip size shall be 20x3 upto 18.5KW , 25x3 for 18.5 to 37KW,25x5 for 37 to 55KW & 32x5 KW beyond 55 KW.
Supply & errection of floor / wall mounted power factor Shunt Capacitor conforming to BIS 2834-1986 latest with up to date ammendments BHEL,GEC,Machneil/Mager/Bajaj make to raise the prevailling power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/ Glosterr/ ICC make from busbar chamber,Chamber to capactor and also including ICTP switches Kilburn </ r) LK/ Standarf Siemen/havells of conforming to 4064-1978or latest with HRC fuses (Range to be specified by the tendere 62 KVAR or 2 sets
Supply of 100mm dia Square dial pressure gauge of suitable range of Fiebeg / Bourden/PREGA/Precision /PREGA make complete with all accessories such as stop cock,copper . tubing etc. conforming BIS 3624-1987 latest with upto date ammendments.
Providing and laying MSERW/ GI pipes of suitable size for suction ,delivery and common header considering site requirements & NPSH required/available.The pipe sizes for suction and delivery shall as per the requirements of offered pump (to be given by the tenderer)and common header shall have area to equal to two times the area of delivery pipe of pump or equal to dia of Rising main including tapers,flanges,bends,rubber gasket,4.8mm thick nuts & bolt and speical upto 5 meters away from the outer wall of pump house as per layout drawing approved by Engineer-in-charge..The pipes material shall conform to relevent BIS codes and capable of of with standing FTP equal to 1.5 times the operating pressure and arrangement shall comprise of :
a) Suction pipe. 200……….. mm dia of 1 x5 mts. Length (4.8 mm as per BIS 1978-1982 of steel grade T-210 with flange table-28) b) Delivery pipe …150mm dia of 1x2 mts, length (---do---)c) Common header…300. mm dia of 5 mts. length. (….do….)
Errection of all equipments from S.No. 1 to 4,6 & 8 i/c cost of tees,bends,tapers & any other fittings required as per site conditions of Engineer-in-Charge.
Supply of horiozental spindle, horizental/radial split casing and suction(backfull out arrange- ments) singe/ double/ multistage centrifugal pumps or combination of pumps in series/parellel of standard make such as KSB/Mather & Platt/ Jyoti /Kirlosker/BE/ Maxflow/Beaconweir con-forming to BIS 1520-1980)Pump(Latest with upto date ammendments) read with BIS 9137- 1978 (latest edition) suitable for lifting Clear water of under mentioned charactristics with bronze impeller / priming funnals, casing ring & shaft) motor of bronze ,shaft of steel grade ASA-410 with cast iron casing coupled directly through a flexible coupling on a common C.I./ Cast steel plate (base plate from the prinicipal manufacturer of pumping set) coupling squirrel cage screen protected drip proof electric induction motor of standard make such as Kirlosker /NGEF /Cromption /Siemen /Jyoti/ BHEL/GEC/ABB conforming to BIS : 325 - 1978 ) read with BIS : 900 - 1968 (latest with upto date ammendments) It should include the cost of bearings,nuts & bolts, painting etc., and shall be suitable for operation as per data given below: 2x45 HP = 90 HP
Make and Model:-KSB Make and Model WL-50/8 STAGES,BHP of Moto 50 HP,RPM 2900,Power observed at duty point 33 KW,Discharge at Dilivery point 9.44LPS,Impeller size 160 mm dia,Efficienct at duty point 66.50 %, A SITE CONDITIONS :- I,Location of site :-The site is located at a distance of 48 Kms from Palampur Maranda,Railway station on Bheri Balakrupi Road Site is located at 120 Kms from Pathankot, & 500 mtrs by head load.ii,The altitude of place in whi 700 Metres above MSL.the motor is intended.,iii,Type of current :- AC three phase supply with freqency of 50 cycles per second.,iv, Rated Voltage :- 415 V = 10 ,v,Type of Water & its source Raw Water from collection tank ,vi,Charactrstics of water :- a) Temperature 20 C b) Turbidity PPM, c) Hardness Mg./ Litres (as Ca Co3 ), d) pH 7.2 f) others -------- e) Total solids. Mg / lit.,vii,Depth of well :- 3 Mtrs.,viii,L.W.L in well/ Sump well:- 618.34 mtrs.,ix,Suction Head:- + ve mtrs.,x,Center line Level of Pump mtrs.,xi,Discharge level of highest point :- 810.40 mtrs.,xii,No. of pump required :- 2 Nos. Pump.( one will act stand by) ,xiii,Capacity :- 8.04 LPS for each pump (Two will act as stand by),xiv,Static head in mtr 192.06 mtrs.,xv,Total head in metres 222.09 Meters,xvi,Length of Rising main :-2370 Metres,xvii,Dia of Rising main :-150 mm dia,xviii,No of pomping Hrs. per day:-16 Hrs.,xix,Limits of pump operation :- (-) 25* to ( + ) 10*of total head.,xx,HP of motor Drive unit :- Required BHP of pump at ( -) 10* & 25* of total headBHP with following margins multiplying factor at, duty point. Whichever is higher, a) Upto 2 HP = 1.5 d) 10 to 20 HP 1.2, b) 2 to 5 HP = 1.4 e) 20 to 100 HP 1.15,c) 5 to 10 HP = 1.3 f) above 100 HP 1.10,xxi,RPM of Pumping Sets:-rpm ,xxii,Test Run :- 20 hrs. continueously for 7 days.,xiii,NPSH available.
Supply of suitable startor rotor of starter of 100 amp. Standared make such as MEI/KILBURN/L&T HAVELLS conforming to BIS 13947-1993 latest with upto date ammendments for squrrel cage/slippering motor mounted on pannel board with magnetic type over released and deshpot,timelog under voltage release with initial oil filling.
Providing M.S sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height & size ISA 65x65x6 mm, duly painted comprising and capable of mounting the following accessaries with all internal electric connections NOTE:.The drawing of panel board shall be subject to approval of the Engineer-in-Charge. 1 no
ICTP 125 amp switches with HRC fuses of Kilburn / Siemens / Standard / Havells/L&T make and having capacity 30 % extra of operational rating of motor as per BIS 4064-1978 with up to date ammendments immediately after the power meter of HPSEB . 2 sets
Bushbar chamber having three copper bars of suitable rating for full length equal to width of the board of three live phases and one copper bar of half reating of full length for natural conforming to BIS 8084 -1976 and 11353 -1985 read with 5578 -1985 all latest with upto date ammendments. 1 no
Oil circuit breaker of 100 Amp.capacity of Standard Havells make as per BIS 2516-1985 with upto date ammendments with neutral linked under voltage release. 1 no
Three phases indicator lamps complete with toggle switches for individual phase conforming to BIS 3452 part I&II latest with upto date ammendments. 2 sets
Earth leakage circuit breaker of 100 Amp 20x3 copper strips.capacity of Standard Havells make as per BIS 2516-1977 with upto date ammendments & of suitable range with which should have control box, erating handle and trip / reset bush button on / off indicator, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with megnet thurmal release with metallic type etc., .It should also be fitted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end. 1 no
Hour run meter of reputed make of four digit capacity conforming to BIS - 722 (latest edition). 2 nos
Change over switch of reputed make & suitable capacity. 1 no
Single phase Preventeor of reputded make & sutable capacity.1no
Three phase voltage monitor relay with all protection 7 usual indicators with electrical siern against single,phasing ,low voltage,high voltage & overloading & phase voltage difference as per BIS: 3842 (latest edition) of sauitable capacity.1 no
Supply of Kirloskar/ Kilburn /IVC/ Fouress/ Gled /BHEL /Leader / Kartar make of cast steel double flanged sluice valve 65 mm( to be provided on delivery side of size one dia higher to the delivery size of pump and capable of with standing nominal seat pressure of 52 kg/ cm2.of class ASA-150 conforming to BS 1414 (API 600).NOTE:- The CI sluice valve shall conform to BIS-780-1984for 50 to 300mm & BIS 2906-1984 for 350 to 1200mm dia (Latest edition). How ever if seat pressure exceeds the limit prescribed in above mentioned BIS than it shall be of cast steel conforming to class ASA-150 for seat pressure upto 21Kg/cm2 or Class ASA-300 for seat pressure 21 Kg/cm2 ASA 150 for seat pressure.
Supply of Kirloskar/ Kilburn / TVC / Fouress/ Gled / BHEL/ Leader Kartar make cast steel double flanged swing check type reflux valve 65 mm having bye-pass arrangement (to be provided on delivery side of Size one sizehigher than the delivery siize of pump and shall be suitable for with standing nominal seat pressure of 52 Kg./cm2 . The reflux valve shall be of class ASA- 150 conforming to BS: 1868 ( API 600 )
Supply of Kirloskar /Kilburn / TVC/ Fouress/ Gled/ BHEL / Leader Kartar make cast steel double flanged swing check type reflux valve 150mm having bye-pass arrangements & size equal to dia of Rising Main i.e. 150mm & shall be suitable for with standing nominal seat pressure of 52Kg./cm2 of class ASA-150 conforming to BS:1868( API-600) with upto date ammendments.NOTE: Ther C.I. reflux valve shall confirm to BIS 5312-1984-part-i(latest eddition).However if the seat pressure exceeds the limits prescribed in BIS 5312 then it shall be of cast steel conforming to class ASA- 150 for seat pressure upto 21Kg/cm2 or class-ASA -300 for seat pressure 52Kg cm2 as per BS 1869 (API-600).
Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex/ Grandlay/Gloster make conforming to BIS: 1554(P-1)1988 or latest with upto date ammend-ments of suitable size for pump sets offered (One cable 3 carrying all three phases) including all other electric al equipment /acessories such as thimmble flexible pipe solder,nuts & bolts & bolts cable4 gland etc., laid in pipes or trenches un der floor. The type size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
a. On supply side of 31/2 core(from HPSEB Meter to switch & Starter)=5mts. Of size25 mm2
b. On Motor side 3 core (From switch & Starter to Motor) =10 mts.of size 16 mm2
Providing & laying double loop earthing and copper plate 600 X 600 X 3mm thick electrode complete with material such as charcoal & common salt, G.I pipes,thimbles,nuts,Bolts,digging of pits G.I wire & copper strips of suitable size conforming to BIS : 3043-1978 latest with upto date ammendments for above motors & other electrical equipment.NOTE: The strip size shall be 20x3 upto 18.5KW , 25x3 for 18.5 to 37KW,25x5 for 37 to 55KW & 32x5 KW beyond 55 KW.
Supply & errection of floor / wall mounted power factor Shunt Capacitor conforming to BIS 2834-1986 latest with up to date ammendments BHEL,GEC,Machneil/Mager/Bajaj make to raise the prevailling power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/ Glosterr/ ICC make from busbar chamber,Chamber to capactor and also including ICTP switches Kilburn </ r) LK/ Standarf Siemen/havells of conforming to 4064-1978or latest with HRC fuses (Range to be specified by the tendere 22 KVAR Or 2.00 Set
Supply of 100mm dia Square dial pressure gauge of suitable range of Fiebeg / Bourden/PREGA/Precision /PREGA make complete with all accessories such as stop cock,copper .tubing etc. conforming BIS 3624-1987 latest with upto date ammendments.
Providing and laying MSERW/ GI pipes of suitable size for suction ,delivery and common header considering site requirements & NPSH required/available.The pipe sizes for suction and delivery shall as per the requirements of offered pump (to be given by the tenderer)and common header shall have area to equal to two times the area of delivery pipe of pump or equal to dia of Rising main including tapers,flanges,bends,rubber gasket,4.8mm thick nuts & bolt and speical upto 5 meters away from the outer wall of pump house as per layout drawing approved by Engineer-in-charge..The pipes material shall conform to relevent BIS codes and capable of of with standing FTP equal to 1.5 times the operating pressure and arrangement shall comprise of :
a) Suction pipe. 200--mm dia of 2 x5 mts. Length (4.8 mm as per BIS 1978-1982 of steel grade T-210 with flange table-28) b) Delivery pipe …150mm dia of 2x2 mts, length (---do---)
Errection of all equipments from S.No. 1 to 4,6 & 8 i/c cost of tees,bends,tapers & any other fittings required as per site conditions of Engineer-in-Charge.
Pawan Virmani
RAJE ENGINNERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .