Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 LAccepted-AOC | ₹13.5 L Quoted ₹13.9 L | L1 | Accepted-AOC Being 1st lowest |
| 2 | L2₹14.5 LRejected-Finance 270 ADARSH NAGAR ROORKEE HARIDWAR 247667 | HARIDWAR | UTTARAKHAND | 247667 | ₹14.5 L | L2 | Rejected-Finance Being 2nd lowest |
| 3 | L3₹16.1 LRejected-Finance | ₹16.1 L | L3 | Rejected-Finance Being 3rd lowest |
| 4 | L4₹16.6 LRejected-Finance | ₹16.6 L | L4 | Rejected-Finance Being 4th lowest |
| 5 | L5₹17.8 LRejected-Finance INDEX NO E 72 HQ CWE HILLS VILL PO MEHUWALA MAPHI NEAR RAJKIYA INTER COLLEGE DEHRADUN UK | DEHRADUN | UTTARAKHAND | 248001 | ₹17.8 L | L5 | Rejected-Finance Being 5th lowest |
| Sl No | Description | Qty | Unit | SWASTIKA BUILDERS L3 | M/s RK ENTERPRISES L5 | CHAUDHARY CONSTRUCTIONS L7 | A.S. CONSTRUCTION COMPANY L2 | SK INFRA INDIA L6 | OM SAI ASSOCIATES AND DEVELOPERS L4 | SAVV BUILDERS L1 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of cement concrete (un-reinforced) in Ground floors and paving n.exe 15 cm thickness ( below or above ground level ) and including removing unserviceable material,outside defence land complete all as specified and directed. | 3 | Cum | 100 ₹300 | 500 ₹1,500 | 300 ₹900 | 100 ₹300 | 200 ₹600 | 200 ₹600 | 50 ₹150 |
| 2.00 | M & L 75 mm thick PCC (1:3:6) type C-2 (Using 40mm graded stone aggregate) as in plinth protection / hardstanding , laid in panels, finished the top surfaces even and fair without using extra cement including filling the joints with mastic compound complete all as specified and directed | 40 | Sqm | 250 ₹10,000 | 250 ₹10,000 | 450 ₹18,000 | 255 ₹10,200 | 300 ₹12,000 | 270 ₹10,800 | 180 ₹7,200 |
| 3.00 | Demolition of cement concrete (reinforced) of any position not otherwise specifically provided for and including reinforcement required to facilitate demolition upto and including on the roof top/mumty/parapet/RCC chajjas/RCC water tank and removing unserviceable material,outside of A 1 defence land complete all as specified and directed. | 6 | Cum | 200 ₹1,200 | 700 ₹4,200 | 900 ₹5,400 | 100 ₹600 | 400 ₹2,400 | 200 ₹1,200 | 50 ₹300 |
| 4.00 | M & L RCC (1:2:4) type B-1 (Using 20mm graded stone aggregate) as in slabs, shelves supported on walls, beams and columns in floor or roof including balconies, canopies, deck slabs or in Chajja / facia projection and the like complete all as specified and directed | 1.5 | Cum | 5,300 ₹7,950 | 5,500 ₹8,250 | 6,000 ₹9,000 | 4,055 ₹6,082.50 | 6,500 ₹9,750 | 5,800 ₹8,700 | 4,500 ₹6,750 |
| 5.00 | M & L for mild steel TMT bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed | 150 | Kg | 90 ₹13,500 | 110 ₹16,500 | 100 ₹15,000 | 80 ₹12,000 | 82 ₹12,300 | 85 ₹12,750 | 85 ₹12,750 |
| 6.00 | Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick for fair finished surfaces (Horizontal or sloping) complete all as specified and directed. | 5 | Sqm | 250 ₹1,250 | 300 ₹1,500 | 500 ₹2,500 | 10 ₹50 | 300 ₹1,500 | 300 ₹1,500 | 70 ₹350 |
| 7.00 | Demolition of brick work built in cement mortar in any description and position including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. | 10 | Cum | 120 ₹1,200 | 400 ₹4,000 | 500 ₹5,000 | 550 ₹5,500 | 250 ₹2,500 | 200 ₹2,000 | 50 ₹500 |
| 8.00 | M & L brick work with sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and directed. | 9 | Cum | 4,500 ₹40,500 | 4,500 ₹40,500 | 6,000 ₹54,000 | 4,155 ₹37,395 | 5,500 ₹49,500 | 5,000 ₹45,000 | 4,400 ₹39,600 |
| 9.00 | M&L brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4) ,complete all as specified and directed. | 10 | Sqm | 850 ₹8,500 | 500 ₹5,000 | 600 ₹6,000 | 555 ₹5,550 | 1,500 ₹15,000 | 1,900 ₹19,000 | 600 ₹6,000 |
| 10.00 | M & L PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate, as in padding, sunken, coping portion rounded chamfered on edge complete all as specified and directed. | 1 | Cum | 5,000 ₹5,000 | 5,000 ₹5,000 | 5,000 ₹5,000 | 3,855 ₹3,855 | 4,500 ₹4,500 | 5,500 ₹5,500 | 4,000 ₹4,000 |
Updated dates
Tender Value
₹24.3 L
EMD Value
₹48,520
Closing Date
27 Mar 2026, 6:00 pmClosed
GE Clement Town
GE Clement Town MES Dehradun
SPECIAL REPAIR TO BLDG NO P-157 AT MES COLONY UNDER AGE B/R-II AT GE CLEMENT TOWN
2026_MES_754665_1
GE/CLT/ Of 20256-26
Open Tender
Civil Works
180 days
GE Clement Town
Class E Cat a(i)
6 documents required · 6 mandatory
₹500
Yes
GE Clement Town
₹48,520
Yes
19 May 2026
27 Feb 2026
3 Apr 2026
27 Feb 2026
27 Mar 2026
13 Mar 2026
Demolition of cement concrete (un-reinforced) in Ground floors and paving n.exe 15 cm thickness ( below or above ground level ) and including removing unserviceable material,outside defence land complete all as specified and directed.
M & L 75 mm thick PCC (1:3:6) type C-2 (Using 40mm graded stone aggregate) as in plinth protection / hardstanding , laid in panels, finished the top surfaces even and fair without using extra cement including filling the joints with mastic compound complete all as specified and directed
Demolition of cement concrete (reinforced) of any position not otherwise specifically provided for and including reinforcement required to facilitate demolition upto and including on the roof top/mumty/parapet/RCC chajjas/RCC water tank and removing unserviceable material,outside of A 1 defence land complete all as specified and directed.
M & L RCC (1:2:4) type B-1 (Using 20mm graded stone aggregate) as in slabs, shelves supported on walls, beams and columns in floor or roof including balconies, canopies, deck slabs or in Chajja / facia projection and the like complete all as specified and directed
M & L for mild steel TMT bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick for fair finished surfaces (Horizontal or sloping) complete all as specified and directed.
Demolition of brick work built in cement mortar in any description and position including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M & L brick work with sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4) ,complete all as specified and directed.
M & L PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate, as in padding, sunken, coping portion rounded chamfered on edge complete all as specified and directed.
Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) not exceeding 1.5 Sq.m each complete all as specified and directed
Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) exe 1.5 Sqm but not exceeding 4.0 Sq.m each.Complete all as specified and directed.
M& L Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 63 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.
S&F factory made single extruded WPC (Wood Polymer Composite) solid both side prelaminated decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed
S&F 35mm thick FACTORY MADE WIRE MESH SOLID WPC Pre-laminated both side DOOR SHUTTER consisting of Density 650 Kg /Cum Manufactured by an ISO-9001-2015 certified Company, Door to be panelled with SS mosquito Mesh and XTN aluminium Mesh for additional strength and safety purpose. (confirming as per S:4020). The door should be water proof, termite proof, fire retardant and having screw holding capacity. Door to be fixed to frame with 3 nos. M.S powder coated butt hinges size 100mm*25mm*2mm and 32mm long steel screws drilled suitable to pass through both the walls of the M.S tube. Other hardware should be fixed with 19*6mm size steel screws etc. Complete as per manufacturer's specification & drawings complete all as specified and directed
S&F steel window with side hung shutters including projecting or box stype hinges with steel handle peg stay and divided into square with glazing bars dovetailed or welded, to receive glazing, or gauzing including one coat of primer including fixing of hold fast of size 25 x 5 mm flat iron etc all complete all as specified and directed.
S&F steel ventilator with top hung shutter including hinges peg stay to receive glazing or gauzing and one coat of primer including fixing of hold fast size 25 x 5 mm of flat iron etc complete all as specified and directed.
M & L butt hinges of mild steel medium weight cold rolled 100mm long and fixed with screws to timber frame work complete all as specified and directed
S&F 200mm long Aluminium barrel tower bolts complete all as specified and directed
S&F 250mm MS sliding door bolts, plate type, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed
S&F 150mm size Aluminium handles complete all as specified and directed
M&L for repair of steel window of any type and section with suitable welding work, replacement of SS wire mesh with screws, replacement of 3mm thick glass panes and painting of window complete all as specified and directed.
M&L for taking down old doors of any type and re-fixing of doors after necessary repair, plaining, welding of hinge, fixing of iron mongry of Stainless steel, repair of wire mesh, painting and making good the disturbed portion of wall with plaster, brick work & painting complete all as specified and directed.
S&F in repair 18 mm thick with min density 600 Kg/Cum LEAD FREE PVC Celuka ply of one side decorative/laminated and other side plain white colour fixed with screws, solvent cement/ adhesive to make kitchen/bed rooms cabinet sides top and bottom and shelves inside the cabinets complete all as specified and directed
S & F in repairs for hasp and staples, size 150 mm, safety type, Stainless Steel Non Magnetic with hinge pin including bolt to hinge plate and fixed with screws, complete all as specified and directed.
S & F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised complete all as specified and directed
S & F D-type cabinet handles premium quality, stainless steel 304 / gloss chrome / SN finished 150 mm long matt finished complete fixed in position complete all as specified and directed.
S & F in repair for stainless steel, 25 mm dia and 1.2 mm thick curtain rod with and including fixing SS brackets and decorative type brass knobs both side of each rod, complete all as specified and directed.
M & L for Mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed
Removal of existing roof treatment i.e APP membrane, brick tiling incl mud mortar and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance, scales, oil or any other loose material complete all as specified and directed.
M & L of water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane as per manufacturer’s instructions with following course of description below :- (a) Applying a priming coat of bituminious primer @ 0.30 Kg /Sqm, till the surface is properly impregnated. (b) Providing APP based 5 layer polymeric membrane minimum weighing 3.6Kg/ Sqm and minimum 3 mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturer's instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer. (c) Apply two coat of bituminous aluminium paint @ 0.20 Kg / Sqm each coat over APP membrance Note : 1. The work of water proofing treatment shall be got executed through authorised applicator of the manufacturer only and 10 year company back warranty to be submitted by contractor 2. The work is required to be carried out at non-accessible roof slab for double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items.)
M & L 50 mm +/- 25mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded stone agg) mixed withliquid water proofing compound (as per manufacture direction and paid separately) over and incl one coat of cement slurry admixed with acrylic bonding compound SBR Latex liquid polymer as to be used for bonding of new concrete / mortar to old surface as per manufacturer direction and finishing the surface even and fair (without using extra cement) as in roof padding to receive roof treatment complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish off the premises from MoD all as specified and directed.
M & L for Non- skid coloured ceramic tiles of any design and pattern, 9 to 10 mm thick (square / rectangular) area of each tile exe 0.18 sqm but not exe 0.38, in floor etc incl 15mm thick screed bed in CM 1:6, Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles complete all as specified and directed.
M & L for Non- skid coloured ceramic tiles of any design and pattern, 7 to 8 mm thick (square / rectangular) area of each tile exe 0.18 sqm but not exe 0.38, in vertical / skirting etc incl 10mm thick screed bed in CM 1:4, Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles complete all as specified and directed.
M & L for Non- skid coloured ceramic tiles of any design and pattern, 7 to 8 mm thick (square / rectangular) area of each tile exe 0.06 sqm but not exe 0.11 sqm, in floor etc incl 15mm thick screed bed in CM 1:6, Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles complete all as specified and directed.
M & L for coloured glazed ceramic tiles of any design and pattern, 450 x 300 x 7 to 8 mm thick, as in dado etc incl 10 mm thick rendering in CM 1:4, Set and jointed in neat cement slurry and pointed in white of coloured cement to match the shade of the tiles complete all as specified and directed.
Demolition of stone slab and tile of any description or thickness laid bedded and pointed in cment mortar in fllors and aprons etc
M & L for 16 to 18 mm thick prepolished marble any colour (green marble) (table rubbed and polished) as in stair case (tread & riser in single piece) steps, jambs, pillars, window cills, cooking platforms including pointing in white cement (1:2) using marble dust to match with marble shade over and including cement screed bed 15mm thick in CM (1:6) complete all as specified and directed
M & L 75 mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base of floor complete all as specified and directed
Taking down cement plaster, terrazzo dado in any thickness from brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc and removing unserviceable material outside of A 1 defence land complete all as specified and directed.
M & L Rendering 15 mm thick on fair faces of brick work or concrete walls internal surfaces in CM 1:6 finished to even & smooth without using extra cement. Complete all as specified and directed.
M & L plastering in two layers consisting of 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces, finished the surfaces even and fair without using extra cement complete all as specified and directed.
M & L rendering 5 mm thick in CM 1:3 in ceiling / Chhajja's finished even and smooth (without using extra cement). Complete all as specified and directed
M&L for preparation of newly plastered surface of internal wall by application of wall care putty to remove the dent and to make the surface even and smooth and applying two coats of acrylic distemper over a coat of primer all as specified and and as directed
M & L for preparation of old decorated surface of internal wall by removing existing treatment and applying two coats of acrylic distemper using roller over wall care putty all as specified
M&L for preparation of newly plastered surface of external wall by application of wall care putty and applying two coats of exterior anti fungal acrylic emulsion paint over a coat of exterior water based primer of same make all as specified and directed
Material & Labour preparing surfaces plastered or unplastered for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance asper IS 15489:2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @1.43litre/10sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over Old surfaces complete all as specified and directed
M & L for preparation of new surface plastered or unplastered ceiling surface by application of wall care putty to remove the dent and to make the surface even and smooth and applying two coats of acrylic distemper over a coat of primer all as specified
M & L for preparation of old decorated surface of ceiling wall and applying two coats of acrylic distemper using roller over wall care putty all as specified
M&L for preparing new steel and iron surfaces of any description over 10 cm Width /Girth and applying two coats of synthetic enamel paint of any tint over one coat of red oxide primer complete all as directed
M & L for prepairing old painted steel and Iron surfaces of any description over 10 cm Width / Girth and applying one coat of synthetic enamel paint of any tint complete all as specified and directed.
M & L PCC 1:7:12 type F-2, using 40 mm graded concrete, as in foundation, mass concreting, sunken floor etc complete all as specified and directed
M & L 10 mm thick rendering in cement mortar (1:4) mixed with liquid water proofing compound on fair faces of brick work or concrete surfaces, finished the surfaces even and fair without using extra cement complete all as specified and directed. Note :- WPC shall be measured and paid seperately.
Supply only integral liquid water proofing compound complete all as specified and directed.
Supply and Fixing 40 mm dia GI light grade pipe as in spout of sunken slab complete all as specified and directed.
Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 15 mm dia .Complete all as specified and directed
S & F for GI tubing 15mm bore, medium grade with all fittings of medium grade (such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions, including short lengths etc.) fixed to walls, concealed in wall and ceiling or laid in floor complete complete all as specified and directed.
M & L for cutting chases on brick or concrete surface for concealed water tubing or / similar work of girth n.exc 10cm including making good of disturbed surfaces with PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate complete all as specified and directed.
Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 20 mm dia .Complete all as specified and directed.
S & F for GI tubing 20mm bore, medium grade with all fittings (such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs,unions etc.) including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete . complete all as specified and directed.
S & F in repair 110 mm bore PVC (SWR) Soil, waste and vent pipes (6 Kg / Sqcm pressure rating) (single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
S & F in repair 75 mm bore PVC (SWR) Soil, waste and vent pipes , single socketed in any length with rubber ring joints laid in trenches or in floorscomplete all as specified and directed.
S & F in repair 75 mm dia PVC (SWR) multi floor trap, with grating including jointing with solvent cement including fixing waste pipe etc complete all as specified and directed
S & F in repair 110 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S & F in repair 75 mm bore PVC (SWR) bend of any radius complete all as specified and directed.
S&F in repair PVC Tee 75mm complete all as specified and directed.
S & F in repair PVC waste pipe 32 / 40 mm dia and length of pipe 750 mm medium grade with coupling complete all as specified and directed
S & F cast copper alloy, chromium plated Towel Rail 20 mm dia, D-type, 600 mm long fixed with and including Chromimum plated brass screws and wooden plastic cleats Complete all as specified and directed .
S & F in repair bib tap cast copper alloy with crutch or butter fly handle, screwed down for iron pipe 15 mm bore of tubing fancy type cromium plated. complete all as specified and directed.
S&F in repair 15mm Stop valve angle cock fancy type, chromium plated with long shunk and cup (concealed type) high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union complete all as specified
S&F in repair chromium plated mixer for Wall for mixing hot and cold water screwed down high for 15mm bore pipe or union. complete all as specified and directed.
S&F in repair chromium plated mixer for Sink for mixing hot and cold water screwed down high for 15mm bore pipe or union. complete all as specified and directed.
S&F in repair vitreous china wash basin 550 x 400mm (flat back including cutting for and pinning in ends of brackets or erecting stands but exclusive of fixing of supply and waste pipe
S & F in repair of sinks made of stainless steel 1.0 mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495mm x 420mm and bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed.
S & F in repair vitreous china squatting pan ‘Orissa pattern’ size 580 x 440 mm white with integral foot rest including connection to trap, and flushing pipe, anti- syphonage pipe, etc and including lime concrete bedding complete all as specified and directed.
S & F in repairs PVC valveless, syphonic action type flushing cistern low level , white, with inlet ball valve, float and handle including brackets and flush pipe for 10 litres capacity complete all as specified and directed.
S & F in repair CP shower rose with or without swivel joints of 125 mm size with shower arm complete all as specified and directed
S & F in repair for PVC Connections 15mm size with PTMT nuts of length 450 mm Complete all as specified and directed
S & F in repairs PVC water storage tank Double layer cylindrical, vertical with closed top with threaded cover hoisted and fixed in position tank capacity 500 Ltr with and including ball valve high pressure of PTMT with epoxy coated Aluminum rod and high density plastic ball screwed for 20mm bore of iron pipe and making connection for inlet and outlet including dismantle of old water tank and removing from site complete all as specified and directed
S & F in repair 15 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for iron Pipe and Complete all as specified and directed.
S & F in repair 20 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for iron Pipe and Complete all as specified and directed.
Disconnecting the electrification and taking down DBs (any type of SPN DBs) and making good to the disturbed surfaces to match the existing surface all as specified and as directed by EIC. Note - Temporary power supply shall be provided by contractor.
Taking down U/S submain wiring aluminium etc and making good the disturbed surfaces of walls/ floor etc matching with the existing surface.
M&L for sub-main wiring (concealed) with two single core 6 sq mm FRLSH PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of massinory including 25 mm dia non-metallic PVC conduit fixed in wall including 6 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by EIC.
M&L for sub-main wiring (concealed) with two single core 4 sq mm FRLSH PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of massinory including 25 mm dia non-metallic PVC conduit fixed in wall including 4 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by EIC.
Taking down carefully aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pedants, regulators, sockets, light fitting etc.. and making good the disturbed surfaces of walls/ floor etc matching with the existing surface all as specified and as directed by EIC.
One light point controlled by one switch.
One ceiling fan point controlled by one switch.
One exhaust fan point controlled by one switch.
One 3 pin socket outlet 5 Amps on the same board.
One 3 pin socket out let 5 Amps on the independent board.
One bell point controlled by one bell push
Two way light point controlled by two way switch
All as per Item No. 89 above but 2.5 Sq mm multi stranded copper conductor with 2.5 Sq mm copper earth continuity wire connected to earth duly complete for one 15A Socket on Independent board all as specified and as directed by EIC.
Supply and fixing surface & wall mounted LED batten 4 feet with 1x20 Watt indoor decorative luminaries with and including electronic driver and 1x20 watt LED Lamp, pre-wired including necessary electric connection with copper flexible PVC cable of 0.50 Sq mm 3 core not more than 1 mtr in length from ceiling rose/connector to light all as specified.
S & F angle lamp holder, PVC Polycab type with back plate suitable for batten fittings complete including fixing of 9/10 watt LED bulb all as specified.
Supply and fixing step socket type modular fan regulator 120/280 V , 100Watt all as specified and as directed.
Supply and fixing modular socket, 6A -2/3 pin combined 2 module ISI marked 230 volts, 50 Hz all as specified and directed by Engr- in-charge.
S & F Switch Modular single pole, one way 6 Amps, 1 module 240 Volts AC all as specified and directed by Engr- in-charge.
Supply and fixing modular socket, 6A/16A -2/3 pin combined 2 module 230 volts 50 hz all as specified and directed by Engr- in-charge.
Supply and fixing switch modular , one-way 16Amps, 1 module 240 Volts AC all as specified and directed by Engr- in-charge.
S & F Switch Modular bell push single pole, one way 6 Amps, 1 module 240 Volts AC all as specified and directed by Engr- in-charge.
Supply and fixing door bell ding dong type suitable for 230 Volts, AC, 230 Volts, single pole.
M & L for ceiling rose, surface bakelite, 65 x 50 mm, three terminals all as specified and as directed.
S & F sheet metal enclosures for SPN DB's with double glazed door for incorporating MCBs,IP-43 , 8 way with 200 amps rated busbar, 240 volts, as per IS-8623 all as specified and as directed.
S & F MCBs SPN 32 amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and out going electric connection with suitable size of copper lugs all as specified and as directed by Engr-in-Charge.
S & F MCB SP, 6 to 32 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and out going electric connection with suitable size of copper lugs all as specified and as directed by Engr-in-Charge.
S & F MCBs SP 40 amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and out going electric connection with suitable size of copper lugs all as specified and as directed by Engr-in-Charge.
S&F DB Power unit MCB protected socket with sheet steel enclosure 20 Amp combo incl 16 amp plug top indicator type for A/C or Geyser
S & F decorative type Glanze Wall light inclding 7/9 watt LED (B22) with all necessary fittings complete all as specifed and directed.
S&F Oval shape Bulk head Edge -lit LED fitting comprising with high brightness LED 10 WATT,IP-67 protection all as directed.
Supply and fix exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230 volts, 50 Hz, 1200 RPM, copper winding of sweep 250 mm complete incl taking out old unser & deposited to E/M store yard all as specified and directed.
S& F Ceiling fan complete with copper winding ,blades ,down rodss and accessories 230 v0lt,1200mm sweep,min delivery 210/215 CFM with service value 6.00 , BEE. Five star rated with BLDC complete with out remot incl taking out old unser & deposited to E/M store yard all as specified and directed.
S&F Electric Water heater,Shock-Resistance & Rust-proof engineering thermoplastic body and heating element up to 2KW , Cap :25 Ltr , BEE 5 Star rated complete with all accessories such as safety valve ,thermostate,NRV ,Connection piece complete incl taking out old unser & deposited to E/M store yard all as specified and directed.
M & L for Earthing complete with galvanised steel pipe electrode, 600 x 600 x 6.3 mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below nominal ground level) with top edge of the plate not less than not less than 1.5 metres below nominal ground level connected to galvanised earthing lead of 4 mm dia of iron or steel wire all as shown in electrical plate No. 5 all as specified and as directed. Note :- the cost of excavation and earth work PCC pit and CI cover funnel & watering pipe, wiremesh, charcoal dust and common salt,GI Pipes ,GI wire up to 7.5 mt shall be deemed included in the unit rate for earthing all as specified and as directed by Engr-in-charge.
Taking down Smart Electric meter carefully with electric connection and refixing the same with connection complete after completion of main control repairing/replacement all as specified and as directed by Engr-in-charge.
NOTES :- 1. For the items for which specifications not mentioned any where in the tender, the BIS specifications shall be followed.
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
Tenderdocs8328.pdf
Tender Documents • 1.29 MB
BOQ_845254.xls
BOQ • 0.56 MB
Download all tender documents and submit your bid