| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 LAccepted-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹11.9 L+₹53,343 (4.68%)Rejected-AOC PLOT NO 2 INDUSTRY AREA NEAR LAL WARE HOUSE OPP OLD HOUSING BOARD COLONY SIRSA SIRSA HARYANA 125055 | SIRSA | HARYANA | 125055 | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹14.7 L+₹3.2 L (28.5%)Rejected-AOC FLAT NO 4 C GH 39 MANSA DEVI COMPLEX SECTOR 05 PANCHKULA 134 109 HRY | PANCHKULA | PANCHKULA | HARYANA | 134109 | L3 | Rejected-AOC Other than lowest bidder |
Tender Value
Refer Docs
Closing Date
24 Sept 2022, 6:00 pmClosed
CWE (AF) Chandigarh
HQ CWE (AF) Chandigarh Pin-160003
REPAIRS TO ELECTRIC WIRING AND FITTINGS INCLUDING GEYSERS AND FANS ETC AT AIR FORCE STATION BARWALA UNDER AGE (I) (AF) HIGHGROUNDS
2022_MES_547050_1
CWE/AF CHD/CHD/T-23/2022-2023
Open Tender
Civil Works
Item Rate
180 days
Chandigarh
As per tender documents
8 documents required · 8 mandatory
₹500
AGE (I) AF Highgrounds
Exempted
2 Nov 2022
23 Aug 2022
1 Oct 2022
23 Aug 2022
24 Sept 2022
10 Sept 2022
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including GI earth wire on batten or in PVC conduit or in MS Conduit including fixtures and fittings such as switches, ceiling roses, pendants, fan regulators, sockets etc, removing materials to store for keeping in safe custody for reuse or for credit (credit for above items shall be made as per conditions separately) and making good disturbed surface of walls, floors, etc., complete all as specified and directed.
Material and labour for point wiring with two single core multi stranded copper conductor 1.5 Sqmm (nominal area) PVC insulated unsheathed FRLS colour code cable of 1100 volts grade drawn through and including non metalic rigid PVC conduit medium duty of suitable size not less than 20 mm dia with all standard fittings such as Tee junction, bends etc, concealed in wall/fixed on ceiling including M.S. sunken boxes of suitable size made of 1.6mm thick MS sheet duly painted with anticorrosive paint, for housing switches, fan regulators etc. with PVC cover sheet 3mm thick (Make : Hylam, Plaza, Havells, Kalinga) including 1.5 Sqmm (nominal area) multi stranded copper conductor PVC insulated unsheathed FRLS colour code cable of 1100volts grade for earth continuity, as for one light/exhaust fan or fan point (through regulator), controlled by one switch, complete all as specified and directed. Note(s) : (i) Rate quoted shall be deemed to include cutting chases for concealing conduit and making good in cement mortar (1:4) or PCC (1:2:4) as required and finishing as per existing finishes. (ii). Switches and fan regulator etc., shall be measured and paid separately.
All as per item No 2 here-in-before but point wiring for one 5 Amps socket outlet point on independent board controlled by one single pole, one way switch, complete all as specified.
All as per item No 2 here-in-before but point wiring for one 5 Amps socket outlet point on the same board controlled by one single pole, one way switch, complete all as specified.
All as per item No 2 here-in-before but point wiring for one bell point controlled by one single pole, one way bell push switch, complete all as specified.
All as per item No 2 here-in-before but point wiring using 2.5 sqmm wire as main wire & 1.5 Sqmm continous earth wire, for one 15 Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
All as per item No. 2 here-in-before but point wiring using 4 sqmm wire as main wire & 2.5 sqmm wire as continous earth wire, for one 15 Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
Material and labour for point wiring with two single core multi stranded copper conductor 1.5 Sqmm (nominal area) PVC insulated unsheathed FRLS colour code cable of 1100 volts grade drawn through existing non metalic rigid PVC conduit with all standard fittings such as Tee junction, bends etc, concealed in wall/fixed on ceiling using existing M.S. sunken boxes for housing switches, fan regulators etc., with provision of PVC cover sheet 3 mm thick (Make : Hylam, Plaza, Havells, Kalinga) including 1.5 Sqmm (nominal area) multi stranded copper conductor PVC insulated unsheathed FRLS colour code cable of 1100 volts grade for earth continuity, as for one light/exhaust fan or fan point (through regulator), controlled by one switch, making good to disturbed surface, complete all as specified and directed. Note(s) : (i) Switches and fan regulator etc., shall be measured and paid separately.
All as per item No 8 here-in-before but point wiring for one 5 Amps socket outlet point on independent board controlled by one single pole, one way switch, complete all as specified.
All as per item No 8 here-in-before but point wiring for one 5 Amps socket outlet point on the same board controlled by one single pole, one way switch, complete all as specified.
All as per item No 8 here-in-before but point wiring for one bell point controlled by one single pole, one way bell push switch, complete all as specified.
All as per item No 8 here-in-before but point wiring using 2.5 sqmm as main wire & 2.5 sqmm wire as continous earth wire, for one 15 Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
All as per item No 8 here-in-before but point wiring using 4 sqmm wire as main wire & 4.0 Sqmm wire as continous earth wire, for one 15 Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
Supply and fixing switch piano, flush type, single pole, one way, 6Amp, 230 volts, complete all as specified and directed.
Supply and fixing bell push, flush type, 6 Amp, 230volts, complete all as specified and directed.
Supply and fixing switch piano, flush type, single pole, one way, 16Amp, 230volts, complete all as specified and directed.
Supply and fixing socket outlet, flush type, 2 in 1, multi purpose, 5 pin, 6Amps, 230volts, complete all as specified and directed.
Supply and fixing socket outlet, flush type, 2 in 1, multi purpose 6 pin, 6Amps & 16Amps, 230 volts, complete all as specified and directed.
Supply and fixing ceiling rose, surface bakelite, polycarbonate / PVC isolated body, 65mmx50mm, two to three terminals, (ISI marked), complete all as specified and directed.
Supply and fixing in replacement bell ding dong type, 5Amp, 230volts, 50 Hz (domestic pattern), complete all as specified and directed.
Supply and fixing fan regulator electronic, stepped type, suitable for 1200 mm /1400mm sweep ceiling fan, fixed in repairs, with and including provision of flexible PVC insulated 1 sqmm copper conductor as required, complete all as specified and directed.
Supply and fixing in replacement factory made prewired LED box type CRCA powder coated batten fitting, 4 feet long, suitable for retofit LED tube 1x20 watt upto connection block and connecting with three core PVC insulated and PVC seathed flexible copper conductor cable of size 01 Sqmm from ceiling rose to connector block, complete all as specified and directed . MAKE- Havells Cat No REGALBATTEN8UPTO1X22WSSBSWH or equivalent in makes mentioned at Appx 'B'
Supply and fixing in repair LED tube rod 20 watts (retrofit LED tube) energy saving, recess / surface mounted luminaire suitable for fixing in the batten fitting 1x18W to 22W, complete all as specified and directed Make : Havells cat No PHOTONULTRA 1213T8SSTL20WLED865SPC or equivalent in makes mentioned at Appx 'B'
Supply and fixing in replacement wall mounted fittings with ABS housing and clear polycarbonate cover including LED bulb 9/10 watts complete and provision of flexible copper 3 core cable 0.5 Sqmm from connector/ ceiling rose to fitting all as specified and directed. Make : Havells Cat No/ Ordering Code No LHLDDDBEIB2R009 or equivalent in makes mentioned at Appx 'B'
Supply and fixing in replacement LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. Make : Havells Cat No PLANO2X2 PLR 34 WLED865S or equivalent in makes mentioned at Appx 'B'
Supply and fixing in replacement LED light fitting 1X9 W batten luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. Make : Havells Cat No LHEXBLP7IN1W009 or equivalent in makes mentioned at Appx 'B'
Supply and fixing in replacement LED 1O watts bollard garden light with aluminium extruded housing with glare free opal diffuser IP65 fitting with robust design and efficient light distribution including light fitting fixing and making PCC block foundation and connecting the fittinngs on PCC foundation block including taking out old, complete all as specified and directed. Make- Halonix HLOB-02-10-CW or equivalent in makes mentioned at Appx 'B'
Supply and fixing in replacement LED 10 watts IP65 rated Inverted Pyramid Tripod type LED Bollard with soft 360 deg light distribution garden light fitting with robust design and efficient light distribution including light fitting fixing and making PCC block foundation and connecting the fittinngs on PCC foundation block including taking out old, complete all as specified and directed. Make- Crompton LBLSN-10-CDL or equivalent in makes mentioned at Appx 'B'
Supply and fixing in replacement LED 30 W, IP65,Aluminium body,3000lm,input voltage 140-270v,cri>80 suitable as building security light, complete all as specified and directed. Make- Havells Cat No VILUMINA SL 30W LED757PASYBOPC or equivalent in makes mentioned at Appx 'B'
Supply and fixing in replacement sheet metal enclosure, SPN, with a two pin socket and earth plug, with one MCB single pole, 240 Volts, 20 Amps, ‘B’ curve, 10 KA, complete all as specified and directed
Supply and fixing in replacement sheet metal enclosure (DB) single phase with neutral, 2 way, 240 volt without bus bar, IP 54 protection, including taking out old unserviceable complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement MCBs Distribution board sheet metal enclosures, SPN 415 Volts, 04 ways with 200 amps rated bus bar, double door, with IP 54 protection, complete all as specified and directed.
All as per item No. 32 here-in-before but DB 8 ways
All as per item No 32 here-in-before but DB 12 ways
Supply and fixing in replacement MCBs Distribution board sheet metal enclosures, TPN 415 Volts, 04 ways with 200 amps rated bus bar, double door, with IP 54 protection, complete all as specified and directed.
All as per item No.35 here-in-before but DB 8 ways.
Supply and fixing Load line TPN vertical distribution board 4 Way double door dust protected powder coated inclusive of busbar, neutral link, blanking plates and having provision for MCCB 4 Pole 100 to 120 Amps as incomer & MCBs SP/TP as outgoing as per IS - 01 No, having IP-43 protection, complete all as specified and directed. Make- Havells Cat No DHDMTHODRW040002 or equivalent in makes mentioned at Appx 'B'
Supply and fixing MCCB, TP, 63 Amps, 415 Volt, having breaking capacity 16 KA, fixed thermal & fixed magnetic setting, Ics=100% of Icu including taking down old MCCB complete all as specified and directed.
Supply and fixing MCCB, TP, 100 Amps, 415 Volt, having breaking capacity 16 KA, fixed thermal & fixed magnetic setting, Ics=100% of Icu including taking down old MCCB complete all as specified and directed.
Supply and fixing MCCB, TP, 125 Amps, 415 Volt, having breaking capacity 16 KA, fixed thermal & fixed magnetic setting, Ics=100% of Icu including taking down old MCCB complete all as specified and directed.
Supply and fixing MCCB, 415 Volt, TPN, adjustable type, 160 Amps with breaking capacity 36 KA, 'C' curve, fixed in repairs, complete all as specified and directed.
Supply and fixing MCB 32/40 Amp, 415 Volt, TPN, breaking capacity 10 KA, 'C' curve, fixed in repairs, complete all as specified and directed.
Supply and fixing MCB 63 Amp, 415 Volt, TPN, breaking capacity 10 KA, 'C' curve, fixed in repairs, complete all as specified and directed.
Supply and fixing MCB 63 Amp, 415 Volt, TP, breaking capacity 10 KA, 'B' curve, fixed in repairs, complete all as specified and directed.
Supply and fixing MCB 40 Amp, 415 Volt, TP, breaking capacity 10 KA, 'B' curve, fixed in repairs, complete all as specified and directed.
Supply and fixing MCB 32/40 Amp, 240 Volt, SPN, breaking capacity 10 KA, 'B' curve, fixed in repairs, complete all as specified and directed.
Supply and fixing MCB 6 to 32 Amp, 240 Volt, SP, breaking capacity 10 KA, 'B' curve, fixed in repairs, complete all as specified and directed.
Material and labour for Sub Main Wiring (in replacement) with two single core 1.5 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed colour code cables, drawn in and including PVC conduit of suitable size with and including one run of continuous multi stranded copper conductor 1.5 Sqmm (nominal area) FRLS PVC insulated and unsheathed colour code cable for earth continuity, 1100 volts grade , complete all as specified and directed. Note(s): (i) Two runs of 1.5 Sqmm main cable + one run of 1.5 Sqmm cable for earth continuity and PVC conduit shall be measured as one unit/one Running Metre.
Material and labour for Sub Main Wiring (in replacement) with two single core 2.5 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed colour code cables, drawn in and including PVC conduit of suitable size with and including one run of continuous multi stranded copper conductor 2.5 Sqmm (nominal area) FRLS PVC insulated and unsheathed colour code cable for earth continuity, 1100 volts grade , complete all as specified and directed. Note(s): (i) Two runs of 2.5 Sqmm main cable + one run of 2.5 Sqmm cable for earth continuity and PVC conduit shall be measured as one unit/one Running Metre.
Material and labour for Sub Main Wiring (in replacement) with two single core 4 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed colour code cables, drawn in and including PVC conduit of suitable size with and including one run of continuous multi stranded copper conductor 4 Sqmm (nominal area) FRLS PVC insulated and unsheathed colour code cable for earth continuity, 1100 volts grade , complete all as specified and directed. Note(s): (i) Two runs of 4 Sqmm main cable + one run of 4 Sqmm cable for earth continuity and PVC conduit shall be measured as one unit/one Running Metre.
Material and labour for Sub Main Wiring (in replacement) with two single core 6 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed colour code cables, drawn in and including PVC conduit of suitable size with and including one run of continuous multi stranded copper conductor 6 Sqmm (nominal area) FRLS PVC insulated and unsheathed colour code cable for earth continuity, 1100 volts grade , complete all as specified and directed. Note(s): (i) Two runs of 6 Sqmm main cable + one run of 6 Sqmm cable for earth continuity and PVC conduit shall be measured as one unit/one Running Metre.
Material and labour for Sub Main Wiring (in replacement) with two single core 10 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed colour code cables, drawn in and including PVC conduit of suitable size with and including one run of continuous multi stranded copper conductor 10 Sqmm (nominal area) FRLS PVC insulated and unsheathed colour code cable for earth continuity, 1100 volts grade , complete all as specified and directed. Note(s): (i) Two runs of 10 Sqmm main cable + one run of 10 Sqmm cable for earth continuity and PVC conduit shall be measured as one unit/one Running Metre.
Material and labour for Sub Main Wiring (in replacement) with four single core 10 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed colour code cables, drawn in and including PVC conduit of suitable size with and including two run of continuous multi stranded copper conductor 10 Sqmm (nominal area) FRLS PVC insulated and unsheathed colour code cable for earth continuity, 1100 volts grade , complete all as specified and directed. Note(s): (i) Four runs of 10 Sqmm main cable + two run of 10 Sqmm cable for earth continuity and PVC conduit shall be measured as one unit/one Running Metre.
Taking up / down water heater (Geyser) of capacity 50/35/25 ltrs operating on 230 volts AC electric supply, in any position and of any make, after disconnecting all electric connections and hot & cold water connection, including transportation to contractor 's workshop for repair and vice - versa, painting / numbering ( if necessary) after repairing, general cleaning/overhauling, cleaning and discaling the tank and assembly with suitable detergent and making the geyser fully serviceable and fixing back in same location / position or new location as directed, complete all as specified and directed. Note :- (a) Replacement of any unserviceable part required for making the geyser serviceable will be measured and paid seperatelly under "supply only" and nothing extra shall be payable on this account.
Supply only stainless steel inner tank suitable for 25 ltrs capacity Geyser of any make / shape /any type of holes for fixing geyser assembly, complete all as specified and directed.
All as per item No 55 here-in-before but for 35 ltrs capacity Geyser.
All as per item No 55 here-in-before but for 50 ltrs capacity Geyser.
Supply only bottom base assembly of copper 9/8/7/6 holes type suitable for 35/25 ltrs capacity geyser, complete all as specified and directed.
All as per item No 58 here-in- before but for 50 ltrs capacity geyser, complete all as specified and directed. .
Supply only Heating element 2000 watts capacity of any shape /type with rubber gasket, complete all as specified and directed. Make :- Ditz, Dass pass
Supply only Thermostat for geyser suitable to adjust the temperature from 0º C to 80º C, complete all as specified and directed. Make :- Ditz, Dass Pass
Supply only Glass wool of good quality as approved, complete all as specified and directed.
Supply only Neon indicator lamp for geyser of any shape / size / colour, complete all as specified and directed
Supply only PVC insulated, sheathed 3 core flexible cable of size 2.5 Sqmm, complete all as specified and directed.
Supply only Safety plug any type for geyser, complete all as specified and directed..
Supply only non return valve 15 mm bore cast copper alloy suitable for geyser, complete all as specified and as directed
Supply only Rubber gasket of thickness 5 mm for geyser assembly with 08 holes / 09 holes, complete all as specified and as directed.
Supply only bottom inspection cover plate in two pieces with suitable openings for indicator lamps, power cable entry with rubber washer etc, gauge of plate not less than 18 SWG for 25/35/50 Ltrs capacity geysers of any make/ shape, complete all as specified and as directed.
Supply only 3 pin plug top 15 Amps, bakelite suitable for 230/240 volts AC supply, complete all as specified and as directed.
Supply only GI nut bolts and washers (not exceeding the size 150 mm x 12mm) of existing size of geyser spare parts, complete all as specified and as directed.
Supply only outer MS shell complete including top and bottom covers suitable for 25 Ltrs capacity geyser of any make, shape & size as per existing but gauge of sheet not less than 22 SWG, complete all as specified and as directed.
Supply only PVC connection 15 mm bore 450 mm long in any position with both end brass nut with inner threading and washer suitable for cold water connection, complete all as specified and as directed.
Supply only CP connection 15 mm bore 450 mm long in any position with both end brass nut with inner threading and washer suitable for hot water connection, complete all as specified and as directed.
Disconnecting & taking down complete ceiling fan of any make 1200 mm / 1400 mm sweep with blade from fan hook/ fan box, transporting to local workshop , opening, cutting and taking out complete copper winding, cleaning with kerosene oil /diesel/ turpintine oil and dried out, rewinding with new super enamelled copper wire of suitable size and gauge in number of turns as recommended by the respective manufactures, varnishing and heating the winding including providing paper insulation (cuff/strip type) replacing u/s paper insulation (cuff / strip type), replacing u/s spare parts (bush, bearing, shackle, insulator, canopy, nuts , bolts, earthing , screw, upper socket, CI block , quarter /split pin (top & bottom) , lock nut, capacitor etc) fixing the stator in rotor, properly aligned and reassembling, ensuring right DOR, speedy and noiseless running and connecting cable and refixing at site or deposited in MES store as directed, complete all as specified and directed. Note: Bush, bearing, capacitor, canopy, shackle insulator with nuts, bolts and sockets shall be measured and paid for separately.
Material and Labour for painting ceiling fans 1200/1400 mm sweep after taking down, with synthetic enamel paint by spraying, including filling cavities with fillter after cleaning all dust etc, re-writing the MES number in black paint in appropriate size and shape and refixing the same in position after painting, complete all as specified and directed.
Supply only capacitor 2.50 MFD, 240 Volt AC, 50 Hz plastic body powder filled type complete all as directed.
Supply only capacitor 3.15 MFD, 240 Volt AC, 50 Hz plastic body powder filled type complete all as directed.
Supply and fixing in repair capacitor 4 MFD, 240 Volt AC, 50 Hz plastic body powder filled type for exhaust fan of 300/400mm sweep complete all as directed.
Supply only MS fan clamps with rubber real including nuts and bolts, split pin suitable for ceiling fan 1200 / 1400 mm sweep complete all as directed.
Supply only bearing suitable for 1200 / 1400 mm sweep ceiling fan complete all as specified and directed.
Supply only bush suitable for 1200 / 1400 mm sweep ceiling fan complete all as specified and directed.
Supply only PVC Canopy suitable for ceiling fan of 1200 / 1400 mm sweep set of two complete all as directed.
Supply only PVC insulated flexible 3 core, 1 sqmm size copper conductor cable including taking out the old unserviceable PVC flexible wire, complete all as specified and directed.
Supply & fixing Mild Steel Down Rod of suitable dia, 45 cm long white or coloured, compatible to existing ceiling fans of 1200 mm or 1400 mm sweep including taking out old unserviceable down rod from the fan, complete all as specified and as directed. Note:- Down-Rod shall be of make of existing fan or as approved by the GE.
Disconnecting and taking down ceiling fan of any sweep for carrying out overhauling such as cleaning, oiling, lubricating, greasing etc and replacement of minor parts such as washer, split pins/ blade screw etc and defective parts, if any, and refixing the ceiling fan fan on same location and connecting it properly and testing for noiseless running to the entire satisfaction of Engineer-in-charge. Note : (i). Defective parts required to be replaced shall be measured and paid for separately as supply only. (ii). Cost of the minor parts i.e. washer, split pins/ blade screw etc deemed to be included in unit rate & nothing extra shall be payable on this account.
Disconnecting & taking down (burnt) exhaust fan of any make 300 mm sweep, transporting to local workshop, opening, cutting and taking out complete copper winding, cleaning with kerosene oil / diesel/ turpintine oil and dried out, rewinding with new super enamelled copper wire of suitable size and gauge as recommended by the respective manufacturer, varnishing and heating the winding including providing paper insulation (cuff /strip type), replacing u/s spare parts (bush, bearing, capacitor etc), fixing the stator in rotor, properly aligned and reassembling ensuring right DOR, speedy and noiseless running and refixing at site or deposited in MES store as directed, complete all as specified and directed. Note: Bush, bearing, capacitor etc shall be measured and paid for separately.
All as per serial item No. 86 here-in-before but 450 mm sweep.
Disconnecting and taking down exhaust fan of any sweep for carrying out overhauling such as cleaning ,oiling, lubricating, greasing etc and replacement of defective parts, if any, and refixing the exhaust fan in same location and connecting it properly and testing for noiseless running to the entire satisfaction of Engineer-in-charge. Note : (i). Defective parts required to be replaced shall be measured and paid for separately as supply only. (ii). Cost of the minor parts i.e. washer, split pins/ blade screw etc shall be deemed to be included in unit rate & nothing shall be paid on this account.
Supply only bearing suitable for 300 / 400/ 450 mm sweep Exhaust fan complete all as specified and directed.
Material and labour for spray painting of Exhaust fan with super enamelled heat resistant synthetic white paint duly filling the cavities with filler and re-writing the MES number in black paint in appropriate size and shape complete all as directed. (Bush, bearing, capacitor, canopy, shackle insulator with nuts, bolts, sockets etc will be measured and paid separately).
Collecting unserviceable (burnt) table / cabin fan of any make and sweep up to 450 mm from MES store, transporting to local workshop, opening, cutting and taking out complete copper winding, cleaning with kerosene oil / diesel / turpintine oil and dried out, rewinding with new super enamelled copper wire of suitable size and gauge as recommended by the respective manufacturer, varnishing and heating the winding including providing paper insulation (cuff / strip type), replacing unserviceable spare parts (bush, bearing, capacitor etc), fixing the stator in rotor, properly aligned and reassembling ensuring right DOR, speedy and noiseless running and depositing in MES store, complete all as specified and directed.
Supply and fixing in replacement electronic energy meter single phase with LCD display 10-60 A Cat Part No WM101BC5DL0 of L& T or its equilant in the makes mentioned at Appx 'B' Note : Old meter shall be deposited in MES Store.
Supply and fixing in replacement electronic energy meter 3 phase with LCD display 10-60A Cat Part No WR301BC7D10 of L& T or its equilant in the makes mentioned at Appx 'B' Note : Old meter shall be deposited in MES Store.
Periodical maint to Fire alarm systems installed in AFNET (Exchange building) (two loop system ) of make Honeywell including replacement of faulty service parts of fire alarm system ( Fire alarm controll pannel ) The alarm function of controll and indicating eqpt (controll Pannel) shall be checked by operation of trigger of each zone. All fault indicators and their circuits shall be checked by stimulation of fault condition (SMOKE DETECTOR). Smoke detector shall be cleaned periodically so as to remove dust or dirt that accumulates on them due to local ambiant condition. At least each detectors shall be is cleaned twice in a month, MANNUAL CALL POINTS HOOTERS: All mannual call points shall be operated twice a month by removing glass cover or by actual braking go glass so as to ensure that system is capable of operation under alarm conditions and all hooters give proper sound, RESPONSE INDICTORS:- All detector which are placed in side a cabin or room shall be tested by indicating the particular detector so as to ensure the proper working of response indicator. WIRING AND CABLES : A visual inspection shall be made so that structure or occupancy changes do not damage cables and sitting of trigger device (mannual call points, smoke detectors and heat detectors) complete all as specified and directed. Note :- All major items will be measured and paid seperately under relevant items.
Supply only ionization smoke detector all as specified and directed.
Supply only Zone cord for fire alarm system all as specified and directed.
Supply only battery, maintanence free, 12V 7 AH complete all as specified and directed. Make- Amaron Model No Quanta 12 V 7 AH SMF or equivalent in makes mentioned at Appx 'B'
Material and labour for point wiring in replacement (FLP-WP) with two single core multi stranded copper conductor 1.5 Sqmm (nominal area) PVC insulated unsheathed FRLS colour code cable of 1100 volts grade drawn through and including ERW metalic rigid steel conduit medium duty of suitable size not less than 20 mm dia with all standard fittings such as Tee junction, bends etc, concealed in wall/fixed on ceiling including M.S. sunken boxes of suitable size made of 1.6mm thick MS sheet duly painted with anticorrosive paint, for housing switches, fan regulators etc. with PVC cover sheet 3mm thick (Make : Hylam, Plaza, Havells, Kalinga) including 1.5 Sqmm (nominal area) multi stranded copper conductor PVC insulated unsheathed FRLS colour code cable of 1100volts grade for earth continuity, as for one light/exhaust fan/bell point or fan point (through regulator), controlled by one switch, complete all as specified and directed. Note(s) : (i) Rate quoted shall be deemed to include cutting chases for concealing conduit and making good in cement mortar (1:4) or PCC (1:2:4) as required and finishing as per existing finishes. (ii). Switches and fan regulator etc., shall be measured and paid separately.
All as per item No 98 here-in-before but point wiring using 4 sqmm wire as main wire & 2.5 Sqmm continous earth wire, for one 16/25 Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
Supply and fixing in replacement switch flame proof rotary type with termination box in LM6, 16A, single pole 250 V, complete all as specified and as directed. Make - Sudhir, Bajaj, Crompton.
Supply and fixing in replacement flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2 Pole+earth, complete all as specified and as directed. Make - Sudhir, Bajaj, Crompton.
Supply and fixing in replacement LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size, complete all as specified and as directed.
Supply and fixing (in replacement ) for two single core 16 Sqmm (Nominal area), 1100 volts grade (heavy duty) cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, complete all as specified and directed.
Note: The Total amount shall subject to adjustment of credit of Rs. 39,734.50 for old Materials as per Schedule of Credit.
M/S ASHWANI KUMAR & CO.
Babu Ram Sud and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .