Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 CrAccepted-AOC MIG 76 DR NO 39 33 146 2 3 MADHAVADHARA VUDA COLONY VISAKHAPATNAM 530 018 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530018 | ₹7.1 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹7.3 Cr+₹15.1 L (2.13%)Rejected-AOC 4 195 38 PARAMESHWARA NILAYA MARAKADA KUNJATHBAIL DAKSHINA KANNADA KARNATAKA 575014 UDYAM KR 11 0021217 | DAKSHINA KANNADA | KARNATAKA | 575014 | ₹7.3 Cr+₹15.1 L (2.13%) | L2 | Rejected-AOC Not being Lowest |
| 3 | L3₹8.1 Cr+₹99.4 L (14.0%)Rejected-AOC | ₹8.1 Cr+₹99.4 L (14.0%) | L3 | Rejected-AOC Not being Lowest |
| 4 | L4₹8.2 Cr+₹1.1 Cr (15.4%)Rejected-AOC | ₹8.2 Cr+₹1.1 Cr (15.4%) | L4 | Rejected-AOC Not being Lowest |
| 5 | L5₹8.3 Cr+₹1.2 Cr (16.6%)Rejected-AOC | ₹8.3 Cr+₹1.2 Cr (16.6%) | L5 | Rejected-AOC Not being Lowest |
Tender Value
₹7.8 Cr
EMD Value
₹7.1 L
Closing Date
18 Sept 2021, 6:00 pmClosed
CE AF BANGALORE
Chief Engineer AF Bangalore No. 2 DC Area MES Road Yeshwantpur Post Bangalore 560022
PROVISION OF PERIMETER WALL AND ALLIED SECURITY INFRASTRUCTURE AT NELLORE SURYALANKA
2021_MES_451243_2
801471/E8
Open Tender
Civil Works
Lump-sum
545 days
AGE (I) (AF) Suryalanka
As per NIT
8 documents required · 8 mandatory
₹3,000
Yes
AGE (I) (AF) Suryalanka
₹7.1 L
Yes
1 Jan 2022
19 Aug 2021
20 Sept 2021
19 Aug 2021
18 Sept 2021
11 Sept 2021
19 Aug 2021 - 30 Aug 2021
Amount
GENERAL SUMMARY NOTE: Schedule ‘A’ Part I to IX are prepriced by MES under Ser No. 1 to 9. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the contractor for “Building or works” as listed in Schedule ‘A’ Part–I
Lumpsum price worked out by the contractor for “Site Clearance & Area Drainage” as listed in Schedule ‘A’ Part–II
Lumpsum price worked out by the contractor for “Internal Water Supply" as listed in Schedule ‘A’ Part–III
Lumpsum price worked out by the contractor for “Internal Electrification” as listed in Schedule ‘A’ Part – IV.
Lumpsum price worked out by the contractor for “Road" as listed in Schedule ‘A’ Part V .
Lumpsum price worked out by the contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part – VI.
Lumpsum price worked out by the contractor for “Security Wall /Gate” as listed in Schedule ‘A’ Part – VII.
Lumpsum price worked out by the contractor for “External Water Supply” as listed in Schedule ‘A’ Part – VIII.
Lumpsum price worked out by the contractor for “External Electric Supply” as listed in Schedule ‘A’ Part – IX.
Schedule 'A' Part X Special item of Work (Concertina Coil): Concertina coil of 610mm dia razor type made out of 2.5mm dia SG hot galvanised spring tensile wire 145 to 150 N/sqmm zinc coating 240gms/sqmm (min), weight of coil shall be minimum 8.57kg/coil when being not stretched, stretch length of coil shall be 6.25Rm after laying. min nos of turns in each coil shall be 49/50. Galvanised razor ribbon type shall be of size 0.5mm thick,19mm wide before wrapping on central core wire. Concertina coil shall be fixed to angle iron swan neck supports using GI clips 125 to 127 Nos per coil and special nuts and bolts for holding coil together and extra two rows parallel wire of 10 gauge etc all as specified and as directed NOTE:- Stretch length of concertina coil shall be measured in running metre.
Internal Water Supply Angle cock cast copper alloy fancy type, chromium plated for galvanised iron pipe of 15 mm dia and fixed complete all as specified and as directed.
Internal Electrification: Supply and fix Exhaust fan of size 200 mm sweep 1350 rpm, 25 watts and connecting up complete, with cable 3 core of size 0.5 sqmm from ceiling rose to fan, provision of 3mm thick bakelite sheet cover including writing MES No 2cm height with synthetic enamel black paint all as specified and as directed. Make: Bajaj model MAXIMA DX or equivalent in Orient/Crompton
Supply and fix Ceiling fan of size 1200mm sweep and connecting up including with, modular type fan step regulator 120W 2 module, cable 3 core of size 0.5 sqmm from ceiling rose to fan, including writing MES No 2cm height with synthetic enamel black paint and fixing loures complete all as specified and as directed. Make: Bajaj Rated 3 Star type / Orient /Crompton.
Supply and Fix and testing of 4ft LED surface & wall mounted sleek and seamless profiled extruded / polycarbonate batten LED luminaires , 19/20 Watts, with latest LED technology and efficient optics ensuring perfectly uniform illumination and unparallelleled light distribution high optically efficient diffuser, 50000 burning hours, with 70% of its initial lumen maintained, fixed complete including all accessories and provision of PVC sheathed 3 core 1.5 Sqmm copper conductor for connection complete all as specified and as directed. Make: Wipro : LL20 - 281-XXX- 65AL1 / Havells : ENDURA LINEAR NEO BS20W LED 840SPC WH/ Crompton LDL-20-CDL.
Supply and fixing and testing 15W High efficient LED Street light, Aluminium pressure Die cast housing parts for longlife,Pure polyester powder coated Dark Gray housing, Toughened glass with silicon gaskets for protection, Driver cover designed to suit top maintenance, Suitable for fixing on walls/poles, including suitable Gl pipe bracket not less than 1.5 meters long CCCV driver with Voltage range 150-270V AC, Surge protection from over voltages- 3.0KV in CM, 50000 burning hours, fixed complete including all accessories and provision of PVC sheathed 3 core 1.5 Sqmm copper conductor for connection complete all as specified and as directed. Make: BAJAJ CAT part No BRLEP 15 W LED / Havells CAT part No ENDURA PEARLSL 15 WLED757 SASYTOPC/ Crompton CAT No LSTS 15-CDL.
Sleek LED 10 watt mirror light with diffuser 2ft version with 10 watt LED lamp complete with all accessories pre-wired and including connecting up with three core flexible copper conductor cable with suitable size. Make :Wipro Cat Part No LL 20-111- XXX-65NE3 or equivalent in Havells/Bajaj/Crompton.
Supply and fix MCB SP 6 to 32 Amps 240 volts 10 KA 50 HZ, C curve complete all as specified and as directed.
Supply and fix MCB SPN 16 Amps 230 volts 10 KA 50 HZ with enclosure complete all as specified and as directed.
Supply and fix Sub main wiring complete with two runs of 4.0 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25mm dia rigid non metallic PVC and conduit accessories concealed/ roof/wall all as specified and as directed. Notes : 4/2 runs of FRLS cable , two/one run of earth continuity conductor and one run of PVC conduit shall be measured as one length.
Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6.3 mm buried directly in ground earth pit not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 mtr below ground level, surrounded from all sides with mixture of charcoal and common salt and electrode connected with galvanized earth lead GI Wire of size 4 mm dia by means of bolts, check nut and washers of GI or steel, GI pipe medium grade of 15 mm bore as protection pipe, GI wire of length not more than 7.5 mtr and connected to test point. GI pipe 20mm dia light grade for watering, funnel with wire mesh, PCC pit and RCC (1:2:4) type B-1 for cover with 8 mm dia bar reinforcement both ways @ 140 c/c including excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr as shown on electrical plate No 3 of SSR Part I 2009 complete all as specified and as directed.
External Water Supply : PVC well cap made of 8 mm thick PVC sheet suitable upto 300 mm bore housing pipe including necessary washer/gasket etc complete all as specified and as directed by Engineer-in-Charge. Make: SUPREME/ APPOLO / SKIPPER/ BANSAL
Water logging test with electro logging equipment & required machinery for ascertaining / logging aquifers encountered in bore well and arranging and defining the water availability test giving test report of Geohydrologist from Govt. approved laboratory recommending water bearing zones, TDS of water etc. complete as directed by Engineer in charge. Note : The contractor shall submit electro-logging result with recommended bore assembly details in duplicate for approval of AGE (I).
M&L for strata sample collection (at every change of strata) one set in suitable wooden box made up of 12 mm thick and with sliding / openable glass cover of 3mm thick, each sample strata should be produced and submitted to department including borewell assembly coloured chart in A4 size duly laminated and framed suitable for hanging on wall with following information furnished by the contractor on completion of the tubewell: (i) Total depth of tubewell drilled, type of size of pipe at levels. (ii) Strata chart of the tubewell indicating different type of soil formations met with at different depths and indicating the depth of each type of soil formation, (iii) Makring of Strata at levels (iv) Position of every joint in well assembly, (v) Method used for development, (vi) Total hours of development done, (vii) Developed discharge in L.P.S. (viii) Discharge is totally sand free or presence of sand particles is there, (ix) P.P.M and turbidity after development, (x) Pumping water level at developed discharge, (xi) Static water level.
Carrying out Chemical analysis of Borewell water sample in any Govt / SPCB approved / NABL accredited lab & submission of Test Report. Tests to be carried out Physical, Chemical and Bacteriological parameters in accordance with IS-10500 complete all as specified and as directed. Note- Quoted rate shall be deemed to be included collection of water sample from site
Sanitary sealing of tube well with PCC (1:2:4) type B1(using 20mm graded stone aggregate ) upto and a depth of 1mtr below ground level and 0.45 mtr above ground level (square type external dimension 600mm x 600mm) around tube well casing, platform of external dimension 1000mmx1000x150mm at ground level with PCC 1:4:8 type D2 foundation (using 40mm stone aggregate) including necessary form work complete all as specified and as directed.
Drilling 01 nos of pilot/trial bore by DTH method through any kind of soil, kankar, boulder or soft or hard rock down up to the 250 RM depth below ground level by using 6.5 inch dia drilling bit including the cost of mud pit channels etc and disposal of soil obtained to a distance not exc.1 km away complete all as directed.
Note: (i) The drilling shall be continued up to specified depth and in case snon availability at water, the location will be changed and fresh driling will be carried out as per direction of Engr-in-Charge. (ii) After completion of pilot/ trial bore, the contractor shall have to arrange for electro logging of each bore (water logging test with electro logging equipment shall be measured and paid as separate item under this Schedule). Without electro logging of bore, reaming work should not be started in any case. (iii) Rig plant along with necessary T&P for drilling bore shall be arranged including its transportation charges by contractor under his own arrangement/cost.
Development of trial/pilot bore holes-01 Nos into tube well to the dia upto 9 inch in alluvial in any type of strata complete by DTH method down to the depth as under including removal of soil obtained up to a distance not exceeding 1 Km and site clearance complete from ground level all as specified and as directed
Supply and lowering and fixing in position 9 inch dia bore (Nominal bore), PVC casing pipe, threaded type, not less thatn 12mm wall thickness suitable for depth up to 150 meter depth, socketed trapezoidal threads jointing, confirming to IS – 12818 / DIN 4925 complete all as specified and as directed. Make: SUPREME/APPOLO/SKIPPER/BANSAL
Supply, Lowering and fix in position 7 inch dia bore (nominal bore), PVC Casing pipe threaded type not less than 12 mm wall thick ness suitable for depth up to 150 meter depth, socketed, trapezoidal threads conforming to IS:12818 / DIN 4925 including necessary jointing complete all as specified and as directed. Make: SUPREME/APPOLO/SKIPPER/BANSAL
Supply, Lowering and fix in position Casing pipe of 7 inch dia bore PVC ribbed screen, strainer slotted pipe, not less than 12mm wall thickness, horizontal slotting done by CNC Machines, slot width right from 0.2mm to 3.00mm, slot numbers designate width of openings in thousand part of an inch, suitable for depth up to 150 meter depth, socketed, trapezoidal threads conforming to IS: 12818 / DIN 4925 including necessary jointing complete all as specified and as directed. Make: SUPREME / APPOLO / BANSAL
Developing tube well with Air compressor for minimum 08 hours of suitable capacity not less than 10 PSI with adjustable length of pipe for pumping muddy water till sand free potable water upto 10 PPM is obtained complete all as specified and as directed. Note : The primary source to running air compressor like fuel /electric supply and other connected resources is deemed to be includied in the quoted rate.
Testing the tube/ bore well for Two consecutive days each of 8 hours after development is completed and determining the yield by continuously pumping for 16 hours to determine safe pumping yield complete all as specified and as directed. Note : The primary source to running motot pump set like fuel / electric supply and other connected resourcesis deemed to be included in the quoted rate.
Monoblock pump set 0.5 HP, 34 m Head, 490 LPH, suitable for 230 V, 1 phase system, with PCC foundation, GI Sheet cover complete all as specified and as directed.
Submersible motor starter for 3 Phase suitable upto 7.5 HP Fully automatic Heavy duty star delta starter with over load, under voltage, dryrun protection, single phase preventer, Angle iron frame work to fix the starter on 3 mm thick CRCA sheet, Suitable incomer MCB, nearborewell with necessary GI sheet cover for outdoor installation, PCC foundation height of stater bottom 1 mtr above the ground level with associated items complete all as specified and as directed.
Supply and Fix / Laying PVC insulated 3 core 6 sq mm Copper multi stranded PVC sheathed flexible, flat, submersible cable ISI marked and conforming to IS 694 and connecting to submersible pump and upto LT panel / starter complete all as specified and directed.
Supply, install, testing & commissioning of Submersible borewell pump (CED coated pump casing), electric driven 415V, 50Hz suitable for 7 inch dia tubewell, Head 140 meter at 100 LPM discharge for column pipe of size 50 mm bore, Bronze Impeller, Stainless, steel motor casing, stainless steel pump shaft, stainless steel motor shaft, no of stages shall be met the required head, SS body motor including electric connection with pump starter all as specified and as directed by Engr-In-Chagre.
External Electric Supply : Supply and fixing LED street light fitting with and including individual high power 48 watt LED new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium with secondary optics, suitable for outdoor use IP 66, connected with connecting cable complete all as specified and as directed MAKE :- Havells Cat No. ENDURAPEARLNEOSL 48WLED 757SASYTOPC or equivalent in PHILLIPS/ BAJAJ/ CG
Street light brackets made of 25 mm dia G.I. Pipe light grade in shape and angle as directed not exceeding 1.5 mtrs in length fixed to pole with suitable size of M.S. flat iron clamps 2 Nos, M.S nut & bolt with cup washers complete all as specified and as directed.
Loop in-out junction box with non metallic FRP junction box suitable of size 350mm x 250mm with connector 4 way and including one MCB 6 A, 230V along with 2 Nos 'C' Clamps and back clamp made up of 20x3 flat iron and fixing on pole with necessary nuts bolts, washers, 2 Nos cable glands of size not exceeding 4 core 25 sqmm, Cable lugs as required complete all as specified and as directed. Make: Sintex, Model: GSJB3525 or its equivalent in Schinder/ Hensel, Note: One Jn Box at WT-1 to tap supply to WT-2 is considered
PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 3 core 1.5 sqmm 1100 Volt, conforming to IS 694, multistranded with Rigid Heavy duty PVC Conduit of 20 mm dia with bends from Junction box to connector of Street light fitting complete all as specified and as directed. Make: Polycab/ Finolex/ Havells/ Gloster/ Nicco
Earthing complete with earth galvanized steel plate electrode 600x600x6mm buried directly in ground earth pit not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 mtr below ground level, surrounded from all sides with mixture of charcoal and common salt and electrode connected with galvanized earth lead GI Strip of size 32x6 mm by means of bolts, check nut and washers of GI or steel, GI pipe light grade of 40 mm bore as protection pipe, GI Strip of length not more than 7.5 mtr and connected to test point. GI pipe 20mm dia medium grade for watering, funnel with wire mesh, PCC pit and RCC (1:2:4) type B-1 for cover with 8 mm dia bar reinforcement both ways @ 140 c/c including excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr as shown on electrical plate No 3 of SSR Part I 2009 complete all as specified and as directed.
Supply, installation, commissioning and testing of LT panel outdoor, double door type made out of CRCA Sheet of 3.15 mm thick with powder coated painting frame made out of angle iron 45 x 45 x 6 mm and four numbers of 100 Amps aluminum strips / bars duly insulated on insulators / suitable size Bakelite sheet, free space between MCB / busbar and other connection items should be provided, the space between ground to panel should be 60 cm with PCC foundation for LT Panel, LT panel should be provided with necessary locking arrangement, danger notice sticker, cable glands, internal wiring with FRLS copper wires and comprising and including the following:
(A) Main Incoming (i) MCB Four Pole 32 Amps, C Curve, 415 V, 50 Hz - 01 Nos (ii) MCB Change over with center off 4 pole, 40 Amps, - 01 No. (iii) LED Multifucntional Panel meter to measure voltage, current, frequency, power factor, KWH, etc with all connected CTs (iv) LED indicating lamps with colour Red, Yellow, Blue, Mains On, Standby On (05 Lights) - 01 Set (B) Main Outgoing (i) MCB FP 16 Amps, 10 kA, C Curve - 04 Nos (For Street Lights, WT-1 and Spare) (ii) MCB DP 16 Amps, 10 kA, C Curve - 06 Nos (For Guard Room, Single living, Pump, WT-3 and Spare-2) (iii) Analog Programmable Time Switch 24 Hour (SST - 15 min) with battery backup - 02 No.
Solar LED 24 W light with inbuilt SCC, Stand alone street light with Solar PV Module 100 wp, MPPT, 2400 lumens, 12 V 80 AH Battery, 5 mtr GI Tube Pole, Metal box for battery assembly, Low battery indication on light, excavation, removing, PCC in foundation and coping, complete all as specified and as directed. Make: Havells /Wipro/ Philips/ Crompton
Supply and fix MCB TPN 32 Amps 415 volts 10KA 50HZ complete all as specified and as directed.
Supply, install, testing and commissioning of Sound Proof DG set 15 KVA, 3 phase 4 wire, 415 volts, 1500 RPM, 50 Hz power supply with power factor 0.8 coupled directly to alternator mounted on a common base plate complete with integral acoustic enclosure having silent features such as modular bolted construction with fabrication on imported CNC torret punch machines, nine tank treatment process with pure polyster based powder coating to ensure long life in all weather conditions and for out door application/ installation, integrated design thereby facilitating /easy handling installation & shifting of the equipment at site. The design of integral acoustic enclosure should be any type approved by national Physical laboratory as per Central Pollution Control Board (CPCB-II) latest norms/regulation with fuel tank, battery and standard accessories and PCC foundation for (acoustic enclosure also 45 CM above ground level) as recommended by manufacturer, vibration pad, sand cushioning around PCC foundation, tools and spares, as provided by manufacturer all as specified and as directed with the following specifications
(A) ENGINE :- Water cooled diesel engine of suitable capacity to match the 15 KVA alternator under NTP conditions with provision of 10% over load for 1 hour in every 12 hours running confirming to BS-5514 / ISO 3046 Standards. The engine shall consist of following :- (i) Fly wheel (ii) Radiator, Air-to-Air After cooler, pusher fan & fan drive arrangement (iii) Dry type Air cleaner with restriction indicator (iv) Fuel injection system of make Bosch (v) Radiator fan (blower type) with guard (vi) Precision governor (mechanical type) Class A1 (vii) Gear Driven Water Pump (viii) Fuel Filter (ix) Spin-on Lubricating oil filters (x) 12 V DC electrical starting system consisting of starter motor, charging alternator. (xi) Exhaust silencer heavy duty residential type (xii) First Fill of Lubricating oil (API CF4 grade, Make Greaves Maxtherm Lube or its equivalent stranded) (xiii) Sensors for Oil pressure, Coolant Temperature & level. (xiv) Exhaust piping as per manufacturer design
(B) Control Panel : The Control Panel is manufactured with 16 guage sheet steel fabricated, dust & vermin proof with complete internal wiring and microprocessor based DG Set controller for both engine and alternator parameter in one console. The Control Panel consists of the following parts: (a) Auto Start Control Module and the Auto mains failure control module or latest model. (b) MCCB of Adequate rating (c) Indicating Lamps for DG ON, Main On, Load on DG, Load on Mains, etc (d) Key switch (e) Set of current transformers and control fuses and MCBs (f) Controller shall monitor and display the engine speed, oil pressure, coolant temperature, frequency, voltage, current, power factor and fuel level, Battery voltage and modules for comprehensive engine and alternator protection.
(C) BRUSHLESS ALTERNATOR:- (i) Alternator coupled to engine through a flexible coupling to an indigenous alternator mounted on strong steel fabricated base frame. Self Excited, self regulated Brush less Single bearing alternator shall be confirming to BS- 5000 or relevant of IS-4722 or latest IS (ii) Type: self excited self regulated with automatic voltage regulator (iii) Rating: 15 KVA at 0.8 PF lagging (iv) Speed - 1500 RPM (v) System - 415 V +/- 2.5% AC 3 phase 4 wire 50 Hz. (vi) Connection - 4 wire star connected (vii) Enclosure -Screen projected drip proof (viii) Ventilation - self ventilated (ix) Insulation: class H , IP-23 (x) Voltage regulation +/- 1%
(D) Sub base Fuel tank 14 SWG MS sheet and capacity to hold diesel sufficient for running minimum of 14 hours at full load including (i) Level indicator on fuel tank. (ii) Drain plug (iii) Piping for fuel tank as per manufacturer design (iv) Fuel strainer. (vi) Battery : 01 Nos 12 V of suitable AH rated with mounting frame.
(E) AMF PANEL OUTDOOR TYPE: The AMF Panel Outdoor type suitable for 15 KVA DG Set factory made out of CRCA Steel 3 mm thick Sheet floor mounted type and front operated type, totally enclosed dust, damp and vermin proof, all doors and joints will be suitable gasketed to form dust and vermin proof. The panel would be powder coated minimum thickness of 50 microns, stove enameled paint finished after elaborate pretreatment to form a long lasting characteristic. The control panel will be complete in all respect with fuses, wiring and labels etc, the following will be incorporated in the AMF Panel :- (a) HRC Fuse with fuse base,Din type - 06 No (b) Current transfrmer, CL-1, 5 VA, 50 /1A-04 No. (c) Four pole Contactor, 240 V AC, 2 NO +2 NC, of Suitable Current, AC3-02 Nos for (DG Set & Commercial). (d) Indicating Lights R ,Y, LED type, 240V AC -04 No. (e) Indicating Lights B, LED type, 240V AC -02 No. (f) Illu Push Button with elements, LED type -NO/NC-01 No. (g) Mushroom head push button, Press to lock, Turn to release-01 No. (h) KW/PF/KWH meter, 3 Phase Digital type 415 V AC-01 No. (j) DC Ammeter Digital type 0-20 A -01 No. (k) 12 V, 10 A DC Automatic Battery Charger with inbuilt trickle / boost facality-01 No
(l) 4 Point Alarm Annuciator with inbuilt Hooter,Test,Accept & Reset Push button. (m) Thermal O/L Relay, with inbuilt SPP Feature (n) AMF Controller,12 V DC - 01 No. (o) Aux relay, Coil voltage, 24V DC, 4C/O,14 PIN-24V DC-06 Nos
GOVARDHAN AND COMPANY
Indus Projects Private Limited
M/s Imperial Coastal Infra
RAJYALAKSHMI BUILDERS
Venkateswara Electricals
K KUMAR RAJA PROJECTS P LIMITED
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .