Loading…
Loading…
Tender ID
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-AOC | L1 | Accepted-AOC AGREEMENT EXECUTED | |
| 2 | L2₹6.4 L+₹488 (0.08%)Rejected-Finance | L2 | Rejected-Finance AGREEMENT EXECUTED | |
| 3 | L3₹7.0 L+₹68,027 (10.7%)Rejected-Finance | L3 | Rejected-Finance AGREEMENT EXECUTED | |
| 4 | L4₹7.4 L+₹1.0 L (16.4%)Rejected-Finance | L4 | Rejected-Finance AGREEMENT EXECUTED |
| Sl No | Description | Qty | Unit | GK INDUSTRIES L2 | SHEFEEK K I L4 | MANUEL K M L1 | POWER ELECTRICALS L3 |
|---|---|---|---|---|---|---|---|
| 1.00Electrification (Renovation) of Dr Ambekar Park | |||||||
| 1.00 | OD482359/2025-2026:
Decorative post top LED lantern 30W , IP65 consisting die casting aluminum body for mounting LED driver and spun aluminum canopy painting pure polyester UV protected powder coated matt black finish after phosphochromate treatment , high quality polycarbonate cover , built in potted ,isolated electronic LED driver with APFC ( SMPS based constant current supply ) with lower THD, output short/open circuit protection, over voltage protection, surge voltage protection up to 10 kv with SPD and other tests, Model: Havells make RUBYNXTPT30WLED or equivalent make . | 20 | each | 5,500 ₹1,10,000 Lowest | 6,063 ₹1,21,260 | 5,763 ₹1,15,260 | 5,763.01 ₹1,15,260.2 |
| 1.00 | 90.3.17.3:Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.50 mm dia GI pipe | 30 | metre | 900 ₹27,000 Lowest | 982 ₹29,460 | 933 ₹27,990 | 933.61 ₹28,008.3 |
| 1.00 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. | 8 | cum | 420 ₹3,360 Lowest | 479 ₹3,832 | 455 ₹3,640 | 455.06 ₹3,640.48 |
| 1.00 | 14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. | 7 | cum | 10,000 ₹70,000 | 10,835 ₹75,845 | 3,500 ₹24,500 Lowest | 10,299.54 ₹72,096.78 |
| 1.00 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels | 12 | sqm | 400 ₹4,800 Lowest | 434 ₹5,208 | 412 ₹4,944 | 412.69 ₹4,952.28 |
| 1.01 | 90.15.4.3:Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 5 | each | 6,900 ₹34,500 Lowest | 7,948 ₹39,740 | 7,555 ₹37,775 | 7,555.26 ₹37,776.3 |
| 1.01 | 90.15.4.4:Supply Conveyance, installation, testing and commissioning of 100W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 10 | each | 9,100 ₹91,000 Lowest | 10,565 ₹1,05,650 | 10,043 ₹1,00,430 | 10,043.2 ₹1,00,432 |
| 1.01 | 90.15.4.9:Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 3 | each | 15,400 ₹46,200 Lowest | 17,296 ₹51,888 | 16,440 ₹49,320 | 16,440.74 ₹49,322.22 |
| 1.01 | OD500259/2025-2026:Supply and installation of 180W LED street light with IP 66 protection Aluminium pressure die-cast body Havells Make Endura Pearl Magnum Plus (PEARLMAGPGENXSL180WLED757PASYTOPCHEEWTX) or equivalent duly wired up for use on 230 V AC supply. Driver compartment should be separately accessible for maintenance. | 2 | each | 13,000 ₹26,000 Lowest | 14,578 ₹29,156 | 13,857 ₹27,714 | 13,857.61 ₹27,715.22 |
Tender Value
₹7.0 L
EMD Value
₹17,622
Closing Date
19 Mar 2026, 3:00 pmClosed
AE
NORTH PARAVOOR MUNICIPALITY
AMURTH .Electrification of Dr Ambekar Park North Paravur Municipality.
2026_LSGD_847324_1
K-1234932/25
Open Tender
Electrical Works
Item Rate
180 days
NORTH PARAVOOR MUNICIPALITY
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,555
₹17,622
NORTH PARAVOOR MUNICIPALITY
26 Oct 2026
13 Mar 2026
19 Mar 2026
13 Mar 2026
19 Mar 2026
13 Mar 2026
13 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Electrification (Renovation) of Dr Ambekar Park | |||||
| 1.001 | OD482359/2025-2026:
Decorative post top LED lantern 30W , IP65 consisting die casting aluminum body for mounting LED driver and spun aluminum canopy painting pure polyester UV protected powder coated matt black finish after phosphochromate treatment , high quality polycarbonate cover , built in potted ,isolated electronic LED driver with APFC ( SMPS based constant current supply ) with lower THD, output short/open circuit protection, over voltage protection, surge voltage protection up to 10 kv with SPD and other tests, Model: Havells make RUBYNXTPT30WLED or equivalent make . | 20 | each | - | - |
| 1.002 | 90.3.17.3:Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.50 mm dia GI pipe | 30 | metre | - | - |
| 1.003 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. | 8 | cum | - | - |
| 1.004 | 14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. | 7 | cum | - | - |
| 1.005 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels | 12 | sqm | - | - |
| 1.006 | 90.15.4.3:Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 5 | each | - | - |
| 1.007 | 90.15.4.4:Supply Conveyance, installation, testing and commissioning of 100W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 10 | each | - | - |
| 1.008 | 90.15.4.9:Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 3 | each | - | - |
| 1.009 | OD500259/2025-2026:Supply and installation of 180W LED street light with IP 66 protection Aluminium pressure die-cast body Havells Make Endura Pearl Magnum Plus (PEARLMAGPGENXSL180WLED757PASYTOPCHEEWTX) or equivalent duly wired up for use on 230 V AC supply. Driver compartment should be separately accessible for maintenance. | 2 | each | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1431928.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.12 MB
BOQ_1431928.xls
BOQ • 0.32 MB
viewsbd.pdf
Tender Documents • 1.65 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .