Loading…
Loading…
Tender Value
₹1.1 Cr
EMD Value
₹2.1 L
Closing Date
24 Dec 2025, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
WORKS N
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet
The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender. NOTE: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered atleast 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Defination of Similar Work :- Any Signaling work involving Outdoor work and/or addition and/or alteration in existing Indoor signaling system. OR Any CLS or RI or EI or TPWS or IBS or ABS or BPAC work involving Indoor and/or Outdoor. Similar work to include Indoor if the tendered work involves addition and/or alteration in existing Indoor signaling system and Outdoor if the tendered work involves Outdoor work. OR Any such work involving activities as given in the name of the tendered work.
10 conditions · 4 needing a document upload
As per Tender document attached.
As per Tender document attached.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Signalling work in connection with the work of "Increasing CSR of Lines at BJW, ADD, UTD and MHD to accommodate full length goods train."
SandT_BRC_25-26_28_SIG~WR
SandT_BRC_25-26_28_SIG
Open
Works - General
8 Months
Vadodara, Gujarat
₹0
₹2.1 L
24 Dec 2025
27 Nov 2025
10 Dec 2025
120 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 19,05,792.36 | ||
| — | 4.00 | — | — | ||
| Failure Analysis & Fault Diagnostic software for data logger of 1024 digital inputs /4096 digital inputs. | — | — | — | 2,09,805.6 | |
| — | 7.00 | — | — | ||
| Main Signal Post Tubular 140 mm Dia, 5.6 Mtr Length as per IRS: S-6/81 or Latest & RDSO Drg. No. SA-24625 (Advance). | — | — | — | 76,267.87 | |
| — | 7.00 | — | — | ||
| "1. CI Base (As per IRS S-10 & RDSO Drg. No. 2011/M With latest assembly). 2. Pinnacle. 3. Ladder Assembly, as per RDSO Drg. No. SA-23156, with Base, Ladder Guards, Platform, Front Maintenance Platform, MS Supporting bracket to Support Ladder. 4. Signal Front Staging Complete Assembly for CLS Unit. 5. Signal back staging as per extent WR Practice." | — | — | — | 22,759.31 | |
| — | 7.00 | — | — | ||
| Supply of signal no plate as per Drg no CSTE Drg No CSTE/6186. | — | — | — | 4,309.13 | |
| — | 1.00 | — | — | ||
| Position Light Shunt Signal Unit Complete with Post (made of GI Pipe of 80 mm Diameter Medium Class IS Spec. No. IS: 1239 Pt. 1/1990) Base, Hood, and Cover, etc. as per Drg. No. SA-23840, Signal Number Plate, suitable for LED Signal Lighting Unit. (Supply of LED Unit is not covered in this item). | — | — | — | 4,530.07 | |
| — | 2.00 | — | — | ||
| Position Light Shunt Signal Unit Complete, with offset bracket, hood, Cover etc. as per Drg. No. SA-23840 suitable for LED Signal Lighting Unit. (Supply of LED Unit is not covered in this item). | — | — | — | 6,719.48 | |
| — | 5.00 | — | — | ||
| Non Metallic (FRP) color light signal housing multi-unit type for railway signaling suitable for RE area TWO Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Vol. 1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. | — | — | — | 1,42,888.6 | |
| — | 2.00 | — | — | ||
| Non Metallic (FRP) color light signal housing multi-unit type for railway signalling suitable for RE area FOUR Aspects. Complete without lenses, lamps and signal transformer as per RDSO Drg.No. SA 23001/A/M Adv. Alt- Sand as per SPEC. No. RDSO/SPN/194/2006 (Vol. 1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. | — | — | — | 66,607.72 | |
| — | 104.00 | — | — | ||
| Track Lead Junction Boxes as per C.Rly Drg. No.RST 11509 made from fiber glass/SMC/FRP along with terminal blocks. | — | — | — | 1,16,547.6 | |
| — | 14.00 | — | — | ||
| Track feed battery chargers, 110V AC input, 2 to 6/10 V DC Output; as per Specn. No. IRS.S 89/ 2013 with latest amendments. Charger shall be suitable for charging 80 AH battery. | — | — | — | 49,325.78 | |
| — | 28.00 | — | — | ||
| Choke Coil for Single Rail Track Circuit on 25 KV 50 Hz AC Electrified Section as per Spec No IRS S 65/1983 with latest amendments. | — | — | — | 59,626.84 | |
| — | 14.00 | — | — | ||
| Adjustable Track Feed Resistance disc type 30 ohms as per RDSO Drg. No. SA 20166/M (Adv.) with latest amendments (with Phenolic molded base). | — | — | — | 13,698.44 | |
| — | 7.00 | — | — | ||
| Cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4 & Spec No IRS S 75/2006 with the latest amendment. The fuse block shall be suitable for round-head type voltage fuses. This also includes the supply of equivalent no of ND type Fuses of 2A capacity as per specification IRS S-78/92. | — | — | — | 905.87 | |
| — | 100.00 | — | — | ||
| HRC fuses block complete with 2A fuse link as per IS 9224/79. | — | — | — | 7,056 | |
| — | 70.00 | — | — | ||
| PPTC fuse 12V GP 16-400 (2A) for TF/TR circuit, make Raychem, Epcos, Siemens. | — | — | — | 729.4 | |
| — | 15.00 | — | — | ||
| DC neutral line relay QNA1K (QSA3), AC immune, DC neutral line 24V, 6F/6B contacts, complete with plug board, retaining clip and connectors. Conforming to BRS930A, (as applicable) IRS: S34& IRS: S23 or latest. | — | — | — | 87,891.15 | |
| — | 15.00 | — | — | ||
| Miniature, Plug in Type, DC Neutral ,Line Relay QSPA1, 24V DC, Slow to Pick up AC Immunized, 12F-4B/8F-4B Contact, Code ABDEJ Spec:BRS:933A ; IRS S 34 ; IRS S 23;IRS S 60-78. | — | — | — | 81,321 | |
| — | 8.00 | — | — | ||
| Miniature, Plug in Type, M to C,DC Neutral ,Track relay, ACI, Style QTA2, 9 Ohm, 2F-1B contact, Code - FGHKX Spec : BRS :939-A & 966 (Appx-F2) & IRS : S-23, S-23,S-34 & 60. | — | — | — | 39,031.2 | |
| — | 7.00 | — | — | ||
| Miniature, Plug in type, M to C, AC immunized, DC biased Track Relay, 2F-2B contacts, style QBAT-9 ohms. Code ABEJX Spec:- RDSO/SPN/84 Ver. 2 : IRS -S@ 45"44@IRS-S-23, IRS-S@ 45<45@ 78. | — | — | — | 37,755.76 | |
| — | 12.00 | — | — | ||
| Maintenance Free Earth Electrode of length 3m, including supply of 3 bags of Earth enhancement material for earthling (10KGs /bag) for each electrode & other accessories as per Drg. No. SDO / RDSO/ E&B/001 and RDSO Spec No. RDSO / SPN/197/2008. | — | — | — | 1,24,836.96 | |
| — | 1200.00 | — | — | ||
| ARA Terminal blocks with links made of PBT Spec No.s/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4. | — | — | — | 90,000 | |
| — | 3.00 | — | — | ||
| SS Location box made of Spl Grade SS 304 of size as per Drg. No. DRM/SG/945 dtd 03.03.2011 (Half app. Case) or latest. Manufacturer's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply. | — | — | — | 1,55,994.18 | |
| — | 6.00 | — | — | ||
| SS Location box made of Spl. Grade SS 304 of size as per drg. No. 6285 (Single (Large) app. Case).Manufacturer's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply. | — | — | — | 3,59,135.88 | |
| — | 6.00 | — | — | ||
| IS 13410: Glass Reinforced Polyester Sheet Moulding Compounds (SMC) Size of Sheet : 1000x1000x8 | — | — | — | 32,332.02 | |
| — | 2.40 | — | — | ||
| Single core multi-strand wire 0.5 sq.mm. (16 conductor each dia. 0.2mm), as per IRS 76/89 (Amd3) or latest. | — | — | — | 13,316.5 | |
| — | 8.00 | — | — | ||
| Supply of spare RFID tags with enclosures and fixtures as per RDSO/SPN/196/ 2020 Version 4.0 | — | — | — | 1,02,400 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TDoc-25-26-28-SIG.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .