Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.7 LAccepted-AOC 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹21.1 L+₹1.8 L (9.36%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹22.7 L+₹3.4 L (17.5%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹23.0 L+₹3.7 L (19.0%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹27.5 L+₹8.2 L (42.6%)Rejected-AOC 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L5 | Rejected-AOC L5 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
3 Jun 2023, 6:00 pmClosed
GE (AF) No 02 Jodhpur
GE (AF) No 02 Jodhpur
RE-WIRING OF INTERNAL ELECTRIFICATION AND ALLIED ACCESSORIES, INCLUDING REPLACEMENT OF SUBMAIN WIRING, MCBs, DBs, REPAIR TO METER BOXES AT CERTAIN OMQs SMQs AND OTM BILLETS AT DOMESTIC AREA OF 32 WING, UNDER AGE EM, GE (AF) NO 02 JODHPUR
2023_MES_593755_1
8379/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) No 02 Jodhpur
As Per Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) No 02 Jodhpur
₹50,000
19 Jun 2023
8 May 2023
5 Jun 2023
8 May 2023
3 Jun 2023
22 May 2023
15 May 2023 - 22 May 2023
Amount
Taking down old unserviceable sub-main wiring aluminium/copper from surface/concealed conduits after necessary disconnection of electrical connection, making good to damaged surface of wall to match with existing surface with smooth finish complete all as directed and specified.
M&L for cutting upto a depth of 2.5 cm into brick/concrete/stone masonry walls, with or without reinforcement and trimming surface as required, for concealing PVC conduit 20/25mm dia and plastering in 1:4CM, applying two coats of approved quality white putty for making good with smooth finish to match with the existing specification of wall surface all specified and directed by engr-in-charge.
M&L for Sub main wiring with approved colour coding as per IS, single core FRLS PVC insulated flexible multi-stranded copper conductor 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, juction boxes etc) including taking down old unserviceable sub-main wiring complete all as specified for following sizes of wires :-.
Two runs of 2.5 Sq.mm main cable alongwith one run of single core 2.5 Sq.mm for continuous earth wire
Two runs of 4.0 Sq.mm main cable alongwith one run of single core 4.0 Sq.mm for continuous earth wire
Two runs of 6.0 Sq.mm main cable alongwith one run of single core 6.0 Sq.mm for continuous earth wire
Two runs of 10.0 Sq.mm main cable alongwith one run of single core 10.0 Sq.mm for continuous earth wire
M&L for Sub main wiring with four runs of 10.0 Sq.mm main cable alongwith two run of single core 10.0 Sq.mm for continuous earth wire (with approved colour coding as per IS), single core FRLS PVC insulated flexible multi-stranded copper conductor 1.1 KV grade drawn through & including 32mm PVC grey conduit heavy duty with necessary accessories (like bend, junction boxes etc.,) including taking down old unserviceable sub-main wiring complete all as specified. (Note : GI saddle shall be used to fix PVC conduit and distance between two saddle shall not be exceed 1.2 mtr)
Labour only for disconnecting all electrical connection of Mains TPN DB in meter box, disconnecting the removing energy metes from meter box and stacking at site for re-use of serviceable meters, removing old rusted/damaged MS iron meter/DB box fixed flush (semi-concealed) to wall surface, making good to damaged surface of wall with kiln burnt subclass-B brick work and plastering with CM 1:4 for smooth finish, white washing the repaired surface after drying all as directed and specified. (Note : Necessary curing shall be carried out by contractor for repaired portion of walls)
Supply, installations, testing and commissioning CPRI approved factory made indoor cubical type panel box for fixing energy meter, 6 each separate compartment for each energy meter, fabricated using 2.0mm thick MS sheet, duly provided with 8 mm thick flame proof backelite/hylem sheet for mounting Energy meters in each compartment, and provision pre-wiring and fixing of incoming and outgoing control MCCB/MCBs, each meter compartment shall provide with front opening hinged door with internal or external locking arrangement. MS box duly painted with two coats of powder coated Semense gray paint over a coat of red oxide primer. The meter box shall designed and fabricated for fixing 01 x MCCB 160 Amps, 4 pole as incomer and vertical or horizontal copper busbar chamber for taking connection to incomer MCB of each meter by using 10 Sqmm, PVC insulated multi-stranded copper conduction wire single core in proper colour codes all as specified to accommodate as under :-(a) MCCB 160 Ams, 4 pole, 16 kA, (Ics=100 % of Icu) - as incommer(b) Copper Busbar 200 Amps duly sleev insulated for set of 3 phase, 4 wire system - 01 Set(c) 2 runs of PVC insulated single core multistraded FRLS grade copper wire for connection from busbar to input supply of Each energy meter by using necessary copper alloy lugs/thimbles.(d) MCB SPN 63 Amps on each meter incomming pre-wired - 6 Nos (Two outgoing on each meter)(e) MCB SPN 40 Amps on each meter outgoing pre-wired - 12 Nos (Two outgoing on each meter)(f) LED Indicator lamp (R,Y,B) - Set of Three. Note : Quoted rate includes the cost of all necessary clamp, wall fasters for fixing meter panel on wall surface and re-fixing energy meter inside panel, making all incoming and outgoing electrical connections with existing input cable and outgoing wires.
Supply, installations, testing and commissioning CPRI approved factory made indoor cubical type panel box for fixing energy meter, 4 each separate compartment for each energy meter, fabricated using 2.0mm thick MS sheet, duly provided with 8 mm thick flame proof backelite/hylem sheet for mounting Energy meters in each compartment, and provision pre-wiring and fixing of incoming and outgoing control MCCB/MCBs, each meter compartment shall provide with front opening hinged door with internal or external locking arrangement. MS box duly painted with two coats of powder coated Semense gray paint over a coat of red oxide primer. The meter box shall designed and fabricated for fixing 01 x MCCB 100 Amps 4 pole as incomer and vertical or horizontal copper busbar chamber for taking connection to incomer MCB of each meter by using 10 Sqmm, PVC insulated multi-stranded copper conduction wire single core in proper color codes all as specified to accommodate as under :-(a) MCCB 100 Ams, 4 pole, 16 kA, (Ics=100 % of Icu) - as incomer (b) Copper Busbar 200 Amps duly sleev insulated for set of 3 phase, 4 wire system - 01 Set(c) 2 runs of PVC insulated single core multi-standrded FRLS grade copper wire for connection from busbar to input supply of Each energy meter by using necessary copper alloy lugs/thimbles.(d) MCB SPN 63 Amps on each meter incoming pre-wired - 4 Nos (Two outgoing on each meter)(e) MCB SPN 40 Amps on each meter outgoing pre-wired - 8 Nos (Two outgoing on each meter)(f) LED Indicator lamp (R,Y,B) - Set of Three. Note : Quoted rate includes the cost of all necessary clamp, wall fasters for fixing meter panel on wall surface and re-fixing energy meter inside panel and making all incomming and outgoing electrical connections with existing input cable and outgoing wires.
Taking down carefully MCBs and DBs TPN/SPN by disconnecting electrical connections and stacking at site for re-use after repairs or shifting unserviceable DBs/MCBs to store for taking credit, making good to damaged surface to match with existing specification all as specified and directed.
S&F sheet metal enclosure distribution board for 240 volts, 8 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as specified & directed.
S&F sheet metal enclosure distribution board for 240 volts, 12 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as specified & directed.
S&F sheet metal enclosures with socket plug top, and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 20 Amps, 240 Volt capacity fixed flush to wall surface including making good to damaged surface of wall to match with existing specification and tested on completion complete all as specified & directed.
S&F in repair MCB single pole 6-32 Amps, 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
S&F in repair MCB SPN 32Amps 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
S&F in repair MCB SPN/DP 40 to 63 Amps 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
S&F in repair MCB TPN/FP, 40 to 100 Amps 415 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
S&F in repair SPN/DP RCBO 40 Amps 240 volts, 30 mA capacity and 10 kA rupturing capacity providing in DB complete including connection & testing all as specified. Make - Havells cat part no-DHCEACSN2030040 or equivalent make mentioned in Appendix ‘B’.
S&F in repair SPN/DP RCBO 32 Amps 240 volts, 30 mA capacity and 10 kA rupturing capacity providing in DB complete including connection & testing all as specified. Make- Havells cat part no-DHCEACSN2030032 or equivalent make mentioned in Appendix ‘B’.
S&F in repair Sheet metal enclosure SPN DBs, 2 way without bus bar complete all as specified and directed.
Nikhat nirman
M/S SUMAN ENTERPRISES
M/S VENUS BUILDER
SANJOLI CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .