Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹43.8 L+₹2.4 L (5.70%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹50.5 L+₹9.1 L (22.0%)Rejected-AOC CHEMBISSERY PUTHIYAKAVU TRIPUNITHURA P O KOCHI 682301 | ERNAKULAM | KERALA | 682301 | L3 | Rejected-AOC L3 | |
| 4 | L4₹66.5 L+₹25.1 L (60.6%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
₹44.5 L
EMD Value
₹89,000
Closing Date
16 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004
CERTAIN SANCTIONED WORKS UNDER AGE EM NO. II.
2022_MES_567003_2
8982/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Kochi
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NS KOCHI
₹89,000
Yes
13 Feb 2023
27 Dec 2022
18 Jan 2023
27 Dec 2022
16 Jan 2023
31 Dec 2022
27 Dec 2022 - 30 Dec 2022
Amount
Supply and Laying UG cable in trenches/passing through pipes/fixed on walls or poles cable XLPE insulated, screened, PVC bedded, steel strip or wire armoured electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 300 sqmm with suitable cable gland including taking down of unserviceable cable complete all as specified and directed.
Ditto All as per Sl Item No 1, but aluminium conductor of size 3.5 core 240 Sqmm.
Ditto All as per Sl Item No 1, but aluminium conductor of size 3.5 core 185 Sqmm.
Ditto All as per Sl Item No 1, but aluminium conductor of size 3.5 core 120 Sqmm.
Ditto All as per Sl Item No 1, but aluminium conductor of size 3.5 core 95 Sqmm.
Ditto All as per Sl Item No 1, but aluminium conductor of size 3.5 core 70 Sqmm.
Ditto All as per Sl Item No 1, but aluminium conductor of size 3.5 core 50 Sqmm.
Ditto All as per Sl Item No 1, but aluminium conductor of size 4 core 10 Sqmm.
Dismantling/taking down steel tubular pole / RCC pole any size by cutting from foundation by means mechanically or manually all as specified and directed. Note : All LED lights fittings on dismantling to be deposit to MES Store yard.
Re fixing the Old tubular poles obtained from Sl Item No. 9, to be fixed at new location as per the direction of Engineer in charge along with all necessary Excavation, PCC foundation, Returning filling, Pole Painting and Pole Fixtures complete all as specified. Note: The rate quoted is deemed to be included the cost of all excavation, foundation and returning & filling and base painting (Pole Numbering) complete all as directed by Engineer in Charge.
Supply and Fixing hot dipped GI octagonal, PU painted (Grey Colour) poles of 6 Metres long with 01 Metre arm suitable for mounting of 01 Nos of LED street lights complete with base plate and GI foundation bolts and nuts including excavation and foundation complete all as specified and directed by Engineer-in-Charge. Note: The rate quoted is deemed to be included the cost of all excavation, foundation and returning & filling and base painting (Pole Numbering) complete all as directed by Engineer in Charge.
Supply and fix in repair LED Street light fitting 1x70 Watt new generation energy saving and environmental friendly long life LED made of pressure dia cast aluminum housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING separate driver compartment with IP 66 protection and heat resistant toughened glass with frame Complete all as specified and directed .
Excavation in trenches not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth for foundation of pole and laying of underground electric cable in soft/loose soil complete all specified and directed.
Supply and spread River Sand for cushioning and covering of UG cables in trenches complete all specified and directed. (Note : For measurement purpose only punned thickness shall be measured and paid)
Material and labour for common burnt clay building bricks sub-class 'B' designation of size 230X115X75mm complete all as specified and directed
Returning filling in including spreading, leveling watering and well ramming in layers not exceeding 25cm complete all specified and directed.
Removing excavated material not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point complete all specified and directed.
Material & Labour for GI tubing medium grade (ISI marked) with all fitting/accessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc all as specified and directed of size 40mm dia including taking down old unserviceable tubing complete all as specified and directed.
Cutting existing road/hardstand of any type by using crow bar chisel up to a depth of 30 cm for laying GI pipe including making good the surface by returning filling watering ramming in layers 150 mm thick PCC 1:2:4 over 150 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Supply and wiring with two run of PVC (FR) insulated multistranded copper conductor cable of 1.5 Sqmm drawing through PVC conduits with continuous earth wire PVC (FR) insulated cable of size 1.5 Sqmm connected to earth including all conduit accessories complete all as specified and directed. (Note: Two run of sub main wire, one run of earth wire and one run of PVC Conduit pipe measured as one unit).
Supply & Fix in street light TIMER control panel, pole/wall mounting made out of CRCA sheet duly powder coated with locking arrangement, including internal wiring complete with bypass arrangements and comprising of following (or as manufactures recommendation and design) including taking down old unserviceable timer panel complete all as specified and directed. (a) Incomer MCB TPN 63 Amps, 240/410V- 01 Nos (b) Digital timer switch - 01 No (c) Contactor AC 3 rating, 3ph, of capacity 65 Amps - 01 No (d) ON/OFF indicating lamp - 01 Set (e) Auxiliary change over switch 6 A - 01 No
Material &Labour for earthing complete with galvanized iron or steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Metres below ground level) with top edge of earth plate not less than 1.5 Metres below ground level connected to galvanized iron strip 32x6 mm by means of nuts, bolts, thimbles, check nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I and specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering funnel with 20mm bore medium grade GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point or LT panel etc, and testing on completion, complete all as specified & directed by Engineer-in-Charge.
Supply and fixing and connecting up Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe as directed/specified for loop earthing etc as required of galvanised iron strip of size 32 x6 mm complete all as specified and directed. Note; This item shall be measured for the quantity used at site after the length of strip 7.5 Metre complete all as specified and as directed.
Material, Labour and using Tools & plants for Underground pneumatic horizontal drilling of holes under road, pavement, hard standing as required length at site by trenchless technology using ultra sound technique with necessary horizontal direction drilling (HDD) machine including providing HDPE Pipe 50 mm outer dia 0.40 Mpa including necessary joint connections and laying LT/HT cable. The contractor shall be conduct underground scanning to detect existing HT/LT cable line, sewage line, OFC Cable etc to avoid damage. The entry/exist hole must be large enough to fit the drilling tool and the operator in it so they can aim the tool. The hole also must be deep enough that as the tool compacts the ground and the surface to be remain undisturbed. The depth of the starting bore pit depends on the type of the soil that is being worked in and how well it compacts. The operator shall aim the tool to the desire exit point and allow it to perform it function creating a bore hole under the ground without disturbing surfaces. The operator also should monitor the surface to make sure that, it is undisturbed. As the tool near to the exit point it is slowed down and the exit pit should be dug to locate both the tool and the bore. As the tool enters the exit pit the operator should choose either dig up the tool to retrieve it or reverses the tool back into the first bore pit to retrieve it including connected earth work, all as specified and directed by Engineer-in-Charge.
Supply and fix 4 Pole MCCB 200 Amp, 50 Hz, 415 V Fixed thermal and fixed magnetic including suitable enclosures with rupturing capacity 35 KA all as specified and directed by Engineer in charge
Supply and fix ON LOAD change over switch 415V with sheet metal enclosures 4 pole of capacity 250 Amps including all fittings & fixtures complete all as specified and directed.
Supply and fix 75KVA Servo Stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ±1% , LCD Display to measure input, output voltage and output current with Over voltage ,under voltage over load and single phase protection with first filling of transformer oil including all necessary incoming and outgoing connections with UG cables all as specified and as directed.
Supply and laying un-reinforced precast concrete cable cover class LV type-I flat size 250mm x 150mm x 40mm complete all specified and directed.
Supply and fixing GI pipe light grade with necessary fittings in floor /pillar/fixed on pole of size 80 mm dia complete all as specified and directed.
Ditto All as per Sl Item No 29, but GI pipe of size 50 mm dia.
Ditto All as per Sl Item No 29, but GI pipe of size 40 mm dia.
Material & Labour for straight through joint 3.5 core 300 Sqmm with all accessories complete all specified and directed.
Material & Labour for straight through joint 3.5 core 185 to 240 Sqmm with all accessories complete all specified and directed.
Material & Labour for straight through joint 3.5 core 95 to 120 Sqmm with all accessories complete all specified and directed.
Material & Labour for straight through joint 3.5 core 25 to 50 Sqmm with all accessories complete all specified and directed.
Taking down carefully copper/aluminium point wiring (light,fan,socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants regulators, sockets, light fittings etc removing materials from site and making good disturbed surface of walls, floors, ceiling etc ,all as specified and directed.
Material and labour for Concealed point wiring with 1.5 sqmm FRLS single core multi stranded copper conductor cable drawn through and including ERW steel conduit of suitable dia including 1.5 sqmm FRLS copper conductor cable as earth continuity conductor complete for one light point controlled by one Flame proof switch.
Supply & Fix Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified directed.
Supply & Fix CIMFR certified LED flameproof batten suitable for twin T8 tube of 20W including LED lamp 20W, Recommended for gas/Vapor group of llA & IIB and Zone 1 & 2, IP65 Protected complete all as directed by Engineer in charge.
Amount of Credit Schedule shall be deducted to arrive the Contract Sum.
P N Enterprises
M/s.Rejoy Constructions
Super Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .