Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.6 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹44.3 L+₹2.7 L (6.47%)Rejected-Finance RZ M 21 NAND BLOCK MAHAVIR ENCLAVE PALAM NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L2 | Rejected-Finance Rejected |
Tender Value
₹56 L
Closing Date
14 Feb 2022, 12:00 pmClosed
AGM Plg
O/o GM Nainital Hq at Haldwani
e- OPEN TENDER DOCUMENT FOR ANNUAL MAINTENANCE CONTRACT (AMC) and ANNUAL REPAIR CONTRACT (ARC) OF DIESEL ENGINE ALTERNATOR AT EXCHANGES/BTSs IN BUSINESS AREA NAINITAL
2022_BSNL_100673_1
GM/NTL/TDR/AMC-ARC-EA/21-22
Open Tender
Miscellaneous Works
Works
365 days
Nainital BA
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
Yes
AO Cash Office of GM Nainital Hq at Hladwani
Exempted
O/o GM Nainital Hq at Haldwani
4 Jul 2022
17 Jan 2022
15 Feb 2022
17 Jan 2022
14 Feb 2022
17 Jan 2022
17 Jan 2022 - 7 Feb 2022
4 Feb 2022
Amount
Details of the E/A for AMC works
Monthly AMC charges of E/A of Range >=5 KVA to < =7.5 KVA
Monthly AMC charges of E/A of Range >=10 KVA to < =15 KVA
Monthly AMC charges of E/A Range > = 20 KVA to < =25 KVA
Monthly AMC charges of E/A Range > = 30 KVA to < =35 KVA
Monthly AMC charges of E/A Range >= 40 KVA to <= 45 KVA
Monthly AMC charges of E/A Range >= 60 KVA to < =65 KVA
Monthly AMC charges of E/A Range >= 70 KVA to < =75 KVA
Monthly AMC charges of E/A Range >= 100 KVA to < =125 KVA
Monthly AMC charges of E/A Range >= 160 KVA to < =180 KVA
Servicing of following rating Engine coupled with alternator i.e. Replacement of Lubricating Oil, Diesel filter, Lube Oil Filter, Cleaning of air filter, Complete cleaning of the Diesel E/A set with testing on load as required.
Range >=5 KVA to < =7.5 KVA
Range >=10 KVA to < =15 KVA
Range > = 20 KVA to < =25 KVA
Range > = 30 KVA to < =35 KVA
Range >= 40 KVA to <= 45 KVA
Range >= 60 KVA to < =65 KVA
Replacement of following faulty items in the existing Diesel E/A set of all capacity with complete testing as required.
Coolant (with Coolant antifreeze)
Battery leads with terminals
Flexible wire braided fuel pipe
Benzo bolts
6 sq mm multi strand copper cable
D.C. Voltmeter 0V to 12V
D.C Ammeter 0A to 100A
A.C. Voltmeter 0V to 500V
A.C Ammeter 0A to 100A
RPM ( Revolutions Per Minute) meter
Pressure gauge
Hour Meter
Cooling fan
Complete repairing, servicing of 12 Volt self starter e.g. Replacement of solenoid coil, cleaning, lubricating teeth etc. complete with testing as required.
E/A Capacity <= 40 KVA
E/A Capacity > 40 KVA
Replacement of V-Belt of following capacities Diesel E/A set complete as required.
Range >=5 KVA to < =7.5 KVA
Range >=10 KVA to < =15 KVA
Range > = 20 KVA to < =25 KVA
Range > = 30 KVA to < =35 KVA
Range >= 40 KVA to <= 45 KVA
Range >= 60 KVA to < =65 KVA
Replacement of following faulty items in the existing Engine instrument/control panel complete with interconnection testing all as required.
Automatic battery charger (SMPS 10 A rating)
Contactor 32 A 415 V TP (NO OR NC)
Contactor 63 A 415 V TP (NO OR NC)
Replacement of AVR of Diesel E/A set sets complete as required.
Replacement of Off load changeover switches of following capacities e.g. interconnections complete as required.
32 A 4 Pole MCB type
63 A 4 Pole MCB type
32A 4 Pole with side handle with SS enclosure
63A 4 Pole with side handle with SS enclosure
Providing and making following provision in the existing control panel including wiring etc. including testing and commissioning etc. as required.
Solenoid switch (E/A capacity <=40 KVA)
Solenoid switch (E/A capacity > 40 KVA)
Engine start relay (E/A capacity <=40 KVA)
Engine start relay (E/A capacity > 40 KVA)
Calibration of fuel injection (FI) pump e.g. dismantling of fuel pump, Cartage to the service station and re-fixing the same e.g. injector timing & tappet setting testing all as required.
E/A capacity <=40 KVA
E/A capacity > 40 KVA
Providing maintenance free New Batteries as a replacement of existing old batteries of following types/rating complete with first fill of electrolyte & first charging e.g. replacement of leads, nut bolts ,terminals/thimbles complete as required. Battery should to of ISI standard company like Exide, Okaya, Luminous etc with 2 Year replacement warranty.
JAI SAI ENGINEERING
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .