| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.9 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹34.3 L+₹75,945 (2.26%)Rejected-Finance 81 82 GHER SAIKH MITHOO KUBRHI PAKHAR ZAKHERA BAREILLY UP | BAREILLY | BAREILLY | UTTAR PRADESH | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹37.4 L+₹3.9 L (11.5%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹39.3 L+₹5.7 L (17.0%)Rejected-Finance A 16 SHIV LOK COLONY RAJPUR ROAD DEHRADUN 248 008 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248008 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹39.4 L+₹5.9 L (17.4%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹49.7 L
EMD Value
₹99,440
Closing Date
18 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COL A S BHANDARI
HQ CWE HILLS PITHORAGARH POST BHARKATIA PIN 262520
UPGRADATION OF EXISTING ELECTRICAL SYSTEM OF MD ACCN (JCOs / ORs) AT MIL STN BANBASSA UNDER GE (MES) PITHORAGARH
2020_MES_368367_1
CA NO CWE / HILLS / PGH/07 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Works
150 days
PITHORAGARH
CLASS D
11 documents required · 11 mandatory
₹500
Yes
GE PITHORAGARH
₹99,440
Yes
1 Jan 2021
11 Aug 2020
20 Nov 2020
12 Aug 2020
18 Nov 2020
27 Aug 2020
13 Aug 2020 - 26 Aug 2020
60 days
Amount
Excavating in trenches in any type of soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. n. exc 10 sq m on plan and n exc. 1.5 m in depth and getting out, complete all as specified and directed.
Returning, filling in any type of soil, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick, complete all as specified and directed.
Removing excavated materials (Soil) n. exc. 50m and depositing where directed at a level n. exc. 1.50m above the starting point, complete all as specified.
Supply, laying & testing of XLPE cable insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 95 sq. mm, 3 core, complete all as specified and directed.
Supply, laying & testing of XLPE cable insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts, grade cross sectional area 150 sq. mm, 3.5 core, complete all as specified and directed.
M & L for dry & clean sand filling in trenches for cushioning of cables punning after filling complete all as specified and as directed. Note:- Punned thickness shall only be measured and paid.
Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 with length equal to the length of the cable cover, laid flat of size 300mm x 180mm x 40mm, complete all as specified and directed.
Material & labour for bricks sub-class`B' (Old size) with length equal to the width of the brick, laid flat in trenches for cable protection all as specified and directed.
S&F cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm, complete all as specified and directed.
S&F cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm, complete all as specified and directed.
S&F cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm, complete all as specified and directed.
S&F 80mm bore, GI pipe, light grade, laid under floor or fixed to walls & ceiling with & including all fittings (if any) required, complete all as specified and directed.
Supplying, fixing & commissioning of galvanized iron polygonal high mast lighting pole, 16.00 m height, having slip-stress fit joints for section and 360mm base outer dia & 150mm top outer dia, suitable for 6 lantern symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope shall be of 6 mm dia, AISI, 7/19 const and double drum winch with luminaries mounting arm, pulley assembly, aviation obstruction warning light, lightning arrester spike, feeder pillar, manual cranking handle, trailing cable, power tool, lantern carriage, head frame, lightening protection finial & buffer and automatic switching control etc., complete all as specified and directed by the GE. Note:- (i) High mast flood lights shall be measured and paid separately under respective items of BOQ. (ii) The cost of base plate & foundation bolts, which are required to be grouted in foundation, shall be deemed to be included in quoted rates. (iii) Earth work, lean concrete, RCC work & reinforcement TMT bars which are required for foundation of high mast lighting pole shall be measured and paid separately under respective items of BOQ.
S&F energy conservation LED flood light luminaries of 100 watts including necessary mounting clamps with nut, bolts and making connection with suitable length of 1.50 Sqmm 3 core, copper conductor cable from junction box to fitting, complete all as specified and directed.
S&F pin type porcelain , vitreous, white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and galvanized iron nut 150 mm height , 150 mm dia for 11000 volts grade, complete all as specified and directed.
S&F disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green, 'two-in-series' assembly for tension with tension clamps for conductors, working pressure 11000 volts, complete all as specified and directed.
Supplying, fabricating, fixing in position cross arms, bracings, supports, clamps and back plates, fabricated from in structural steel section any type /size /shape including nuts bolts washers, welding, bending hot or cold, drilling holes for bolts, in any shape or size as required at site, including painting with two coats aluminium paint over a coat of red oxide including dismantling of old unserviceable existing cross arms complete all as specified and directed.
S&F cable path indicator made out of 75mm dia CI disc of 5mm thick written as "MES HT CABLE" welded on 40x40x5mm size MS angle iron, complete all as directed by Engr-in-Charge.
S&F lightning arresters expulsion type, suitable for 11000 volts, complete with all fittings, transmission class, discharge capacity 65 kilo amp, complete all as specified and directed.
M&L for stay assembly complete comprising of 7/3.15 galvanized stranded stay wire of required length fixed to pole with and including FI clamp 50x6mm size, bolts, nuts washers, galvanized steel stay rod 20mm dia and 2400mm long with nuts, bolts and washers, stay bow 400x14mm galvanized steel plate 300 x 500 x 6mm two numbers, thimbles loop insulator size 65 x 90 mm clearance hole 16mm including two coats of aluminium paint over a coat of red oxide primer on exposed mild steel work as shown in electric plate No. 1 of SSR Part-I 2009 on page No 495 with & including the following provisions:- (a) Excavation in post holes in any type of soil, returning, filling & well ramming including disposal soil to distance not exc 50 mtrs from starting points. (b) PCC (1:3:6), type C-2, using 40mm graded stone aggregate as in foundation., complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.50 m below normal ground level connected to with and including earth lead of 32x6 mm size GI flat iron up to 7.50m by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES SSR Part-I(2009) connected to main switch board or main control board all as specified and testing on completion with & including provision of earth strip protected by galvanised iron 40 mm dia. light grade pipe up 7.50m and watering pipe shall be 20 mm bore medium grade with and including concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab in RCC (1:2:4) type B-1 using 20 mm graded stone aggregate duly reinforced with 8 mm TMT bars @100mm C/C on both sides with suitable cast iron lifting handle, GI earthing strip shall be encased in and including 50mm nominal bore GI 'light grade' tubing with all fittings from earth plate up to transformer mounted on PCC platform shall be provided & charcoal / salt funnel & other fittings etc. complete all as specified and as directed. Note :- (i) Unit rates includes the cost of 7.50 m GI pipe for protection of earth strip and 7.50 m GI earth lead strip. (ii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed to be included in quoted rates.
S&F triple pole mechanically operated with 9 insulator, 11 KV grade, out door type gang operated air break switch horizontally / vertically mounting fixed type, complete with operating mechanism using GI pipe 25mm dia medium grade suitable for operating mechanism working from ground level for current rating up to 200 Amps capacity, complete all as specified and directed
S&F in replacement 11000 volts expulsion fuse single pole, swing out type current carrying capacity above 50 Amps and up to 100 Amps (Set of three), complete all as specified and directed.
Dismantling of old unserviceable existing HT 11 KV OCB panel 400 Amps with CTs & PTs and deposit the same in MES store complete all as directed by Engr-in-Charge.
Supply, installation, commissioning and testing of indoor type vacuum circuit breaker incoming draw out type high voltage 11 KV, 630 Amps, 50 Hz AC STC 13.4 KA/ 3 Sec IAC for 1 Sec including earth fault and over current protection relay and auxilary relay for rato faults, short circuit breaking current with stand voltage 28 KV bus bar rating 630 Amps and manual / motorised operated spring, charging mechanism type triple pole totally enclosed in CRCA sheet metal enclosure, painting with epoxy powder coated confirming to relevant IS or AlZn sheet with metalic shutters including CT of 5 VA burden and ratio 50-25/5 for switch OFF & ON 11 KV feeder complete with standard fittings, control protective relay panel with interlocking mechanism instrument including wiring in separate compartment etc. and directed by Engr-in-harge including of protective relays with indicator such as the following:- (a) Over current & Earth fault protection relay IDMT static numerical type with indicator (1:3) times the rated current - 01 No. (b) Master trip relay - 01 No. (c) Spring charge and trip mechanism manual & motorised - 01 No. (d) Digital measuring instruments Ammeter, Voltmeter & Multifunction meter for measurement of power factor i.e KVA, KVAR, frequency, KWHR - 01 No. each. (e) DC power pack 110 V to operate relay unit, power pack of suitable capacity contained maintenance free battery and charger to provide auxiliary power supply to the vacuum circuit breaker 11 KV all as per OEM recommendation or as directed by the GE. (f) Indicator for "ON & OFF" healthy circuit, DC failure and other as per manufacturer's recommendations. (g) Any other standard fittings / accessories required for smooth functioning of vacuum circuit breaker 11 KV or all as directed by the GE. (h). 11 KV/V3 of 30 VA 0.5 class line connected PT for incomer only. Note:- (i) All panel bus bar should be inter connected. (ii) Vacuum circuit breaker 11 KV will be installed & commissioned at site by the Engineer / OEM including relays calibration as per circuit load requirements and all as directed by the GE. (iii) The job includes all internal control wiring with suitable size of copper conductor cable, necessary electrical connection and PCC /RCC (If any) required for founadtion of vacuum circuit breaker 11 KV all as directed by the GE. (iv) Only OEM make panel shall be provied. (v) The contractor shall submit the complete lay out diagram of all components i.e HT cable, circuit breaker etc in proper laminated board after completion of work. Make:- ABB / SCHENIDER / SIEMENS / L&T
M&L for PCC 1:3:6 type C-2, using 40 mm graded stone aggregate as in lean concrete of foundation of high mast lighting pole, complete all as specified and directed.
M&L for RCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in foundation of high mast lighting pole, complete all as specified and directed.
M&L TMT bars, 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for column, hooking ends and binding with and incl MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
shahji contractors
SEEMA ELECTRICAL
Amit Engineering
TUSHAR ASSOCIATES
RAMAPATI ENGINEERING SERVICES
Perfect Electricals and Engineers
shivam builders
M/S Shahjee Fridge Service
sunder and company
GUPTA ENGINEERING WORKS
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .