Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.7 LAccepted-AOC 00 BEHIND COURT PHALODI NAI SARAK PHALODI JODHPUR RAJASTHAN 342301 UDYAM RJ 22 0048153 | JODHPUR | RAJASTHAN | 342301 | L1 | Accepted-AOC M/S Mahaveer Traders is the Lowest Bidder, hence accepted | |
| 2 | L2₹7.3 L+₹30,810 (4.41%)Rejected-Finance 77 KAILASH PURI BIKANER RAJ C 15 SWC JAIPUR | BIKANER | RAJASTHAN | 331801 | L2 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 3 | L3₹8.2 L+₹1.2 L (16.9%)Rejected-Finance 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L3 | Rejected-Finance Not Lowest Bidder, Hence Rejected |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
15 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh Nitish Pathak
GE(AF) Phalodi
REPAIR MAINT OF GEYSERS AND CONNECTED WORKS AT AF STN PHALODI
2024_MES_674847_1
8631/A/E8
Open Tender
Civil Works
Item Rate
180 days
Air Force Station
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE(AF) Phalodi
₹20,000
Yes
8 Nov 2024
17 Sept 2024
22 Oct 2024
17 Sept 2024
15 Oct 2024
1 Oct 2024
Amount
Disconnecting water and electric connection in existing position of geyser capacity 25 ltrs including taking down geysers fixed to wall at any height by its own arrangement and repair/replacement of unservicable parts of geyser and same will be fixed at existing position after repair at site complete all as specified and directed. Note:-(i) The spare parts will be measured and paid separateley as supply only against appropriate items of BOQ. (ii) Contractor either himself or his accredited agent shall collect the day to day complaint slip from concern JE in the morning daily from AGE E/M office and deposit the same after complaince. If, Contractor fails to attend the complaints of normal nature within 24 Hrs he shall be levied penalty of Rs 50/- per complaint per day. (iii) The contarcor should provide vehicle for attending of daily basis complaint and carry unservicable /serviceable geysers to the work site & AGE E/M office or vice versa. (iv) Nature of complaints either urgent or normal shall be decided by the Engineer-in-charge.
Supply only assembly with rubber washer and inlet/outlet of any type complete all as specified and directed.
Supply only heating element with rubber washer ('O' ring/Tringle ring) capacity 1.5 KW of any type complete all as specified and directed.
Supply only heating element with rubber washer ('O' ring//Triangle ring) capacity 2.0 KW of any type complete all as specified and directed.
Supply only Indicator bulb neon round/square type single phase 230 Volt complete all as specified and directed.
Supply only Safety plug 15mm (brass) for geyser capacity 25 Ltr complete all as specified and directed.
Supply only thermostat 30°C to 70°C rated current 10-15 Amp,230 Volts complete all as specified and directed.
Supply only glass wool complete all as specified and directed.
Supply only inner tank for geyser capacity 25 ltr of Steel sheeting for Geyser complete all as specified and directed.
Supply only of rubber washer 6 hole for geyser assembly capacity 25 ltr of steel sheeting for geyser complete all as specified and directed.
Supply only of neck ring for geyser capacity 25 ltrof any type complete all as specified and directed.
Supply only bottom cover for geyser capacity 25 Ltr of any type in two halves as per existing Geyser complete all as specified and directed.
Supply only safety Valve for Suitable Capacity of 25Ltr cap Geyser complete all as specified and directed.
Supply and fixing in replacement of unserviceable PVC flexible inlet outlet connection 15 mm dia,45 cm long with brass nuts bolts and washers suitable for hot water supply etc complete all as specified and directed.
Supply and fixing inreplacement of unserviceable PVC flexible inlet outlet connection 15 mm dia,60 cm long with brass nuts bolts and washers suitable for hot water supply etc complete all as specified and directed.
Material & Labour for stoping the leakage by brazing of inner copper/steel tank not exc 2.5 cm in length and making the tank leak proof including testing etc complete all as specified and directed.
Supply and fixing inreplacement of unserviceable PVC flexible inlet outlet connection 15 mm dia,45 cm long with brass nuts bolts and washers suitable for cold water supply etc complete all as specified and directed.
Supply and fixing in replacement of unserviceable outer body/cover suitable for 25ltr cap geyser made out of mild steel pre-treated and stove enamelled sheet of 18 SWG complete with top and bottom cover, rubber gasket, stead screw for fixing the top and bottom cover to outer body easing including two coat of white synthetic enameled paint over one coat of red oxide primer complete all as specified and directed.
Material & Labour for grouting the bolt of size 6"x1/2" with nut in wall in repairs for fixing the geysers complete all as specified and directed.
Supply and fixing in replacement of MS bracket for mounting of Geyser 25 Ltr cap complete all as specified and directed
Material & Labour for spray painting to geysers of capacity 25 ltrs with two coats of synthetic enamel white paint over one coat of red oxide(primer) including scratching of old paint and making surface smooth by using filler etc complete all as specified and directed
Taking down carefully copper /aluminium sub main wiring of any size including fixture and fittings through any type of conduit and removing material from site icluding making good distrubed surfaces of walls/floors/ceilings etc complete all as specified and directed.
Material & Labour for Sub main wiring with 2 runs of 2.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC casing caping ISI marked size 20mm with accessories fixed on wall/roof and one run of 2.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor complete all as specified and directed. Note : Two runs of 2.5 Sqmm cable, one run of 2.5 Sqmm earth conductor and one run of PVC casing caping of 20mm shall be measured and paid as one unit length.
Material & Labour for Sub main wiring with 2 runs of 4.0 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC casing caping ISI marked size 20mm with accessories fixed on wall/roof and one run of 4.0 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor complete all as specified and directed. Note : Two runs of 4.0 Sqmm cable, one run of 4.0 Sqmm earth conductor and one run of PVC casing caping of 20mm shall be measured and paid as one unit length.
Material & Labour for Sub main wiring with 2 runs of 6.0 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC casing caping ISI marked size 25mm with accessories fixed on wall/roof and one run of 6.0 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor complete all as specified and directed. Note : Two runs of 6.0 Sqmm cable, one run of 6.0 Sqmm earth conductor and one run of PVC casing caping of 25mm shall be measured and paid as one unit length.
Material & Labour for Sub main wiring with 2 runs of 10.0 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC casing caping ISI marked size 25mm with accessories fixed on wall/roof and one run of 10.0 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor complete all as specified and directed. Note : Two runs of 10.0 Sqmm cable, one run of 10.0 Sqmm earth conductor and one run of PVC casing caping of 25mm shall be measured and paid as one unit length.
Supply and fixing in replacement of Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket, one single pole 20 Amps, 240V MCB, 10KA , 'B' curve complete all as specified and directed.
Supply and fixing in renewal SP 6 To 32 Amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing in renewal Switch socket combination 6A/16A, 5 in 1, flush type complete all as specified and directed.
Supply and fixing in renewal plug top 3 pin 15 Amp complete all as specified and directed.
Supply and fixing in renewal metal clad plug top and socket 3 pin 15 Amp complete all as specified and directed.
Supply and fixing Switch socket combination 5A/16A, 5 in 1, flush type with PVC box complete all as specified and directed.
Supply and fixing in replacement of unserviceable 25 mm width heavy duty double lock press type casing & caping ISI marked fixed to wall /ceiling using screws of suitable size including removing the existing for replacement complete all as specified and as directed.
Supply and fixing in replacement of unserviceable 40 mm width heavy duty double lock press type casing & caping ISI marked fixed to wall /ceiling using screws of suitable size including removing the existing for replacement complete all as specified and as directed.
Material & Labour for Sub main wiring with 4 runs of 6 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC conduit ISI marked 32mm dia(external) with wall thickness not less than 1.8mm with conduit accessories fixed on wall/roof and one run of 6 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Four runs of 6 Sqmm cable, one run of 6 Sqmm earth conductor and one run of PVC conduit of 32mm dia shall be measured and paid as one unit length.
M/S SOLANKI GENERAL SUPPLIERS (BID ID -3129205)
KRISHNA CONSTRUCTION COMPANY (BID ID -3127595)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .