Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹38,277
Closing Date
28 Jan 2025, 4:05 pmClosed
ENGINEER (PROJECTS)
KEL MAMALA KOCHI
Setting up of Integrated Plastic Waste Management Facility at Kunnamthanam - in Pathanamthitta District -Civil Work - Additional Final Work
2025_KEL_728767_1
KRO/BDC/1815/2025
Open Tender
Civil Works - Buildings
Item Rate
KEL MAMALA
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,950
₹38,277
Yes
30 Jan 2025
21 Jan 2025
29 Jan 2025
21 Jan 2025
28 Jan 2025
21 Jan 2025
21 Jan 2025 - 28 Jan 2025
Amount
Cooling and Hot WaterTank
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
od211846/2024_2025 : Providing and fixing ferrocement water tanks made of cement, iron, and concrete, with dimensions of 2.1 m x 1.2 m x 1.2 m and a capacity of 2100 liters
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
50.6.1.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
Roof For ETP Tank & Chiller Tank
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
10.16.2 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12.41.2 : Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
50.18.9.22.11 : Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling
Plumbing
50.18.7.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge 20 mm dia 10 Kgf/cm2- Internal work - Exposed on wall
50.18.7.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall
50.18.7.4.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall
50.18.7.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall
50.18.8.9.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2
50.18.9.22.1 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow
50.18.9.22.12 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer
od212145/2024_2025 : Providing and fixing uPVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge 20 mm dia ASTM SCH 40 - Internal work - Exposed on wall
od212146/2024_2025 : Providing and fixing uPVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia ASTM SCH 40- Internal work- Exposed on wall
od212147/2024_2025 : Providing and fixing uPVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia ASTM SCH 40- Internal work - Exposed on wall
od212148/2024_2025 : Providing and fixing uPVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia ASTM SCH 40 - Internal work- Exposed on wall
od212149/2024_2025 : Providing and fixing uPVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia ASTM SCH 40 - Internal work- Exposed on wall
od212150/2024_2025 : Dismantling RCC work manually or by mechanical means, including stacking of steel bars and disposal of unserviceable material within a 50-meter lead, and concreting after placing PVC/uPVC pipes of the required size as per the direction of the engineer in charge
Electrification
od212069/2024_2025 : Providing and fixing Centrifugal Monobloc Pumpset 1HP, 1 PH, 2800RPM, Pump Size: 2"x1.1/2", Make KIRLOSKAR
od212070/2024_2025 : Providing and fixing Centrifugal Monobloc Pumpset 1.5HP, 3 PH, 2800RPM, Pump Size: 2"x1.1/2", Make KIRLOSKAR
od212071/2024_2025 : Providing and fixing Centrifugal Monobloc Pumpset 3 HP, 3 PH, 2800RPM, Pump Size: 2.1/2"x2", Make KIRLOSKAR
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Landscaping
Ultra-Filtration System
od212170/2024_2025 : Supply, instalation, testing and commisioning of Ultra-Filtration System 1800 LPH (As per above specifications) Specifications: MICRON FILTER - Quantity :- 1 No. ,Type :- 20” Jumbo Wound, Service flow :- 2.0 m3/Hr , MOC :- PP ULTRA FILTRATION - Quantity :- 1No, Permeate flow :- 1600 LPH, Net water recovery :- 80-90%, UF MEMBRANE :- Quantity - 1 Nos. Membrane Area = 40 m2 (min), MOC of Fibers - PES/ PVDF Membrane Technology - NIPS, Mode of Filtration - Out- In, Mode of Operation - Cross Flow, Make of Membrane - Dupont/ TheWay/ Hydracap UF INSTRUMENTATION :- Flow meters - 2 Nos (Rotameter), pH sensor - 1 No, Valve system - Electrical Solenoid valves, Make of Valves - Uflow/ Air, Pressure Gauges - 2 Nos UF CONTROL PANEL :- Type of Panel - Fully Automatic Control Panel ACCESSORIES :- UF Skid - SS 304, UF Pipeline - uPVC, Level Control - Float Switch BACKWASH PUMP :- Type - Monobloc Centrifugal MOC - CI, Make - KBL/ LUBI FEED PUMP :- Type - Monobloc Centrifugal,MOC - CI, Make - KBL/ LUBI ACID DOSING SYSTEM :- Type of Dosing - Diaphragm Type, Capacity - 6 LPH @ 5 Bar Pressure, Make of pump - E- Dose/ FC Dose, Capacity of Tank -50 Lts ALKALI DOSING SYSTEM :- Type of Dosing - Diaphragm Type, Capacity - 6 LPH @ 5 Bar Pressure, Make of pump - E- Dose/ FC Dose, Capacity of Tank - 50 Lts
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
ETP Control Panel, Earthing and Necessary Electrical Works
od212181/2024_2025 : Supply, Laying and Termination of Armored/ Flexible cable for all equipmentInstallation of Cable tray for the Cable Laying, Incomer Line from DB (Located in ETP Room) to ETP Control Panel
od212182/2024_2025 : Supply, installation, and testing of earthing system for the Effluent Treatment Plant control panel, including copper strips/wires, earth pits, and necessary accessories
Miscellaneous Work
2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
od212268/2024_2025 : Cleaning the Floor and removing dirt, dust etc with the help of compressed air Blowing and also washing the surface with clean water with the help of pressure jet machine, complete in all respect, all complete asper the direction of Engineer in charge
od212269/2024_2025 : Providing and supplying garden hose of 30 meters length and 1/2 inch (12.7 mm) diameter, made of flexible and durable PVC material, reinforced with high-strength synthetic fibers. The hose shall be UV-resistant, weatherproof, and suitable for safe water passage, and capable of withstanding a minimum working pressure of 6 bar and a burst pressure of 18 bar.
od212270/2024_2025 : Providing labour for cleaning the surrounding areas by sweeping with broomsticks and collecting waste, followed by burning the debris at a designated location in a safe and environmentally compliant manner. The work includes: Cleaning all allocated areas as per instructions. Collecting and segregating debris. Burning debris responsibly without causing harm to surroundings or violating environmental regulations.<br>The work also includes cleaning toilets, which entails: Washing and scrubbing toilet surfaces, including floors, walls, and fixtures, Cleaning and sanitizing commodes, washbasins, and urinals. Using approved cleaning agents and tools to achieve a thorough and safe clean
od212271/2024_2025 : Providing and fixing inauguration stone of size 2 meters x 1 meter, made of High-quality polished granite stone, uniform in color and texture, with a thickness of 20 mm. Engraved text and emblem as per approved design. Smooth edges and a polished surface. Securely fixed at the designated location with cement mortar (1:4) or mechanical anchors as required.Ensure alignment and proper setting.
od212272/2024_2025 : Providing and fixing name boards made of 4 mm thick foam board of high-quality, lightweight, and durable material. Resistant to moisture and suitable for indoor and outdoor use. Size and layout as per Requirment, Text printed, adhered neatly and securely. Mounted securely on walls or designated structures using adhesive or mechanical fasteners.Ensure proper alignment and finishing. Smooth edges and clean surface, free from dents, scratches, or defects.
EXCLUSIVE OF GST
Note :1 All materials, Items, Equipment shall be best branded items with IS and approved by client/KEL
2:Rate should be inclusive of Insurance,Transportation, delivery and installation cost for all items
3.Rate should be Exclusive of GST.
4.Work should be executed as per DSR/PWD specification and direction of Engineer at site.
5.CEMENT: Make use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
6.STEEL REINFORCEMENT: Make: Tata,Vaishak, SAIL, JSW or eq primary make in the order of preference
7.CENTERING & SHUTTERING: (Centering and shuttering for different category of work may be considered separately.)
8. SOLID BLOCK MASONRY: Min. average compressive strength as per IS shall be 40-50kg/cm2 and has to be assessed by testing at Govt. lab. ( Variation in rate due to change in size of block and level of floor as per DSR/PRICE has to be considered)
9.PLUMBING & SANITARY FITTINGS: Note: Make of Water supply and sanitary items: Best branded ISI make Jaquar, Cera, Hindware, Parryware or eq. in the order of pref. Water pipe: Supreme, Finolex or eq. with IS and all fittings with IS.
10.RCC: (Assessment of strength of concrete by Cube testing at Approved Govt labs as per IS) Cement make: Use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
11.ELECTRICAL: Note: Rate should be inclusive of preparation of schematic diagram and getting approval from KSEB/Electrical Inspectorate. Statutory fees paid to KSEB/EI shall be paid by us separately.
Make of Electrical equipments/materials
All electrical materials/equipments shall be of best branded items with ISI, strictly as per schedule specification
Panel Boards: CPRI certified reputed manufacturers make
MCB/ELCB/DB - L&T/LEGRAND/SCHNEIRDER or equivalent
Cables & wires - Finolex/KEI/POLYCAB/RPG/V-GUARD
CUBIX INFRASTRUCTURES (BID ID -2079778)
saaj constructions (BID ID -2079001)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .