Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.0 LAccepted-Finance 2 A NARENDRA APPARTMENT CENTRAL JAIL ROAD SUBHASH BRIDGE AHMEDABAD 380027 | AHMEDABAD | AHMEDABAD | GUJARAT | 380027 | L1 | Accepted-Finance Accept | |
| 2 | L2₹16.4 L+₹3.4 L (26.3%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L2 | Rejected-Finance Rejected due to bidder not L1 | |
| 3 | L3₹17.0 L+₹4.0 L (31.0%)Rejected-Finance | L3 | Rejected-Finance Rejected due to bidder not L1 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
22 Jul 2023, 6:00 pmClosed
Maj Ravinder Sharma and Smt Saroj A Makwana AE QS
Smt Saroj A Makwana AE QSC and Shri Sandeep Verma AGE BR1
Repair to fan and window split AC water cooler Desert cooler in various unit in AOR of GE Ahmedabad
2023_MES_607443_1
8349/E8
Open Tender
Civil Works
Works
180 days
GE (Army) Ahmedabad
As per NIT
8 documents required · 8 mandatory
₹500
GE (Army) Ahmedabad
₹30,000
7 Aug 2023
30 Jun 2023
24 Jul 2023
30 Jun 2023
22 Jul 2023
7 Jul 2023
30 Jun 2023 - 7 Jul 2023
Amount
Taking out old hermetically sealed compressor unit (uncut) from water cooler storage type, 40 ltr/hr cooling capacity and replacing the sealed unit with factory reconditioned sealed unit of same brand as per existing (Existing make - Tecumesh Kirloskar 4440/436/443) including the following:-
Connection to suction/discharge pipe with necessary repairs and brazing.
Replacing capillary tube of existing size and copper liquid filters.
Flushing of entire system before gas charging.
Gas charging and testing after repairs including installing the machine at site and testing on full load for its smooth functioning complete.
All as per item No 1 above but for water cooler storage type 60 litre per hour cooling capacity.
Renewal of acrylic vegetable tray suitable for refrigerator of 286/300/310 ltr capacity as approved.
M&L for gas charging to compressors of undermentioned installed machine/equipment to its full capacity with specified grade of refrigerant including other connected process required for gas charging and testing complete for the following :-
Refrigerator 286/300/310 ltr capacity.
Water coolers 40 to 60 ltr/hrs cooling capacity.
Air conditioner window type 1.5 Ton capacity.
Air conditioner split type AC of 1.5/ 2.0 Ton capacity.
S&F in repairs condensor (heat exchanger) coil for any make water cooler of 40 ltr capacity with necessary cutting / welding and brazing work to match with existing condensor complete.
S&F in repairs condensor (heat exchanger) coil of for any make window type AC 1.5 Ton capacity with necessary cutting / welding and brazing work to match with existing condensor complete.
S&F in repairs condensor (heat exchanger) coil of for any make split type AC 1.5 Ton capacity with necessary cutting / welding and brazing work to match with existing condensor complete.
S&F in repairs condensor (heat exchanger) coil of for any make split type AC 2.0 Ton capacity with necessary cutting / welding and brazing work to match with existing condensor complete.
Renewal of relay package assembly with over load protector of water cooler 40 litre/hour cooling capacity for any make including necessary electrical connection, lugs, insulation tape etc all complete.
Renewal of relay package assembly with over load protector of water cooler 60 litre/hour cooling capacity for any make including necessary electrical connection, lugs, insulation tape etc all complete.
Renewal of thermostat switch with knob for water cooler of cooling capacity 40 litres per hour of any make including necessary electrical connection, lugs, insulation tape etc complete. Make - Indfoss / Ranutrol.
Renewal of thermostat switch with knob for refrigerator of 286 / 300 / 310 litres capacity of any make including necessary electrical connection, lugs, insulation tape etc complete. Make - Indfoss / Ranutrol / Annapurna.
Renewal of thermostat switch with knob for any make Air Conditioner of 1.5/2.0 Ton capacity. Make - Indfoss / Ranutrol / Annapurna.
M&L for rewinding of fan motor of water cooler of any make with super enameled copper wire of existing size and weight as required including replacement of bushing and capacitor of 2.5 mfd complete.
M&L for rewinding for fan motor of air conditioner of any make and model with super enameled copper wire of existing size and weight including replacement of bushing as required.
Renewal of water circulating submersible pump with motor 1/20 HP, 230 volts AC, ISI marked for any make desert cooler including electric connection complete.
Renewal of cooling pads for desert cooler complete.
Renewal of fan blade of water cooler of 40 to 60 litres per hour cooling capacity suitable for any make and model as required.
Renewal of of PTMT float valve assembly of 15 mm bore with plastic ball with suitable connections galvanized iron nipple 3” long and suitable GI sheet for fixing float valve suitable for water cooler of any make. Make - Prayag or equivalent ISI marked.
Renewal of 15 mm dia concussive push taps of cast copper alloy, screwed for iron pipe for water cooler complete.
Taking out hermetically sealed compressor unit (uncut) from the window type air conditioner of any make, 1.5 Ton capacity and replacing the sealed unit with reconditioned sealed unit complete. Make of compressor :- Tecumesh -1500 / Kirloskar-5522/CR-22
Connection to suction/discharge pipe with necessary repair and brazing.
Replacing the capillary tubes of existing size and copper liquid filter
Flushing of entire system before gas charging.
Gas charging and testing after complete repairs including instalation of the machine at site and testing on full load for its smooth functioning complete.
All as per item No 21 above but for split type AC 1.5 Ton capacity. Make - Kirloskar CR-22, Tecumesh-1500/5522.
All as per item No 21 above but for split type AC 2.0 Ton capacity. Make - Kirloskar 5531/Tecumesh 2000, CR 30.
Taking out hermetically sealed compressor unit (uncut) of refrigerator for 286/300/310 ltr capacity, (Make : Godrej/Kelvinator) and replacing the sealed unit with reconditioned sealed unit of same brand (Existing make - Tecumesh-1343 / 1350 / 358 / Kirloskar / Godrej) including the following :-
Connection to suction/discharge pipe with necessary repairs and brazing.
Replacing capillary tube of existing size and copper liquid filters.
Flushing of entire system before gas charging .
Gas charging and testing the unit to the entire satisfaction complete.
Renewal of relay with overload protector for AC split type 1.5 Ton capacity including necessary electric connections, lugs, insulation tape etc complete. Make - AEI /Shriram
Renewal of relay with overload protector for AC split type 2.0 Ton capacity including necessary electric connections, lugs, insulation tape etc complete. Make - AEI/Shriram
M&L for repair to body (viz. sides, base, bottom of tank) of water cooler of any make by replacing rusted worn out portion with suitable plain mild steel sheet of existing gauge to match original, mild steel angle iron suitable to match the existing body including transportation from MES store yard to repair shop and back complete.
M&L for repair to body (viz. sides, base, top) of refrigerator of capacity 286 / 300 / 310 litre by replacing rusted, worn out portion with suitable mild steel sheet & mild steel angle iron suitable to match the existing body and repair to door, bottom side and front panel including transportation from MES store yard to repair shop and back complete.
Renewal of PVC connection pipe 45 cm long both end brass joint with rubber washer complete.
Removing the old paint from the surface of water cooler of any capacity smoothly, clean and prepare the surface and applying two coats of auto sign colour paint of classic/ducco, white/light blue shade glossy finish (spray paint) over one coat of primer paint including to & fro transportation from MES store yard to repair shop and back complete.
Removing the old paint from the surface of refrigerators of 286/300/310 litre capacity smoothly, clean and prepare the surface and applying two coats of auto sign colour paint of classic/ducco, white/light blue shade glossy finish (spray paint) over one coat of primer paint including to & fro transportation from MES store yard to repair shop and back complete.
Removing the old paint from the surface of window air conditioner 1.5 Ton capacity smoothly, clean and prepare the surface and applying two coats of auto sign colour paint of classic/ducco, white/light blue shade glossy finish (spray paint) over one coat of primer paint including to & fro transportation from MES store yard to repair shop and back complete.
Removing the old paint from the surface of desert coolers and applying two coats of synthetic enamel paint by brush over one coat of red oxide primer after prepration of surfaces of desert cooler of any specification.
Renewal of air filter suitable for window type AC of any type as required.
S&F in repair door gasket superior quality for refrigerator of any capacity and make as required.
Renewal of box type relay with over load protector for refrigerator of capacity 286/300/310 litres capacity of any make including necessary connections, lugs, insulation tape etc as required.
Renewal of cabinet bulb pin/thread type 15 watt for refrigerator complete.
Renewal of cooling coil for refrigerator capacity 286 / 300 / 310 ltrs complete.
Renewal of 15 mm bore GI water tubing medium grade including all fitting for connection of water cooler with existing pipe line complete.
Renewal of air filter suitable for split type AC of 1.5 / 2.0 Ton capacity as required.
Renewal of 3 speed regulator switch for desert cooler complete.
Renewal of PVC insulated sheathed flexible round, 3 core cable with copper conductor of size 24 / 0.20 for refrigerator, desert cooler & water cooler of different make and size complete.
Renewal of PVC insulated sheathed flexible round, 3 core cable with copper conductor of size 80 / 0.20 for AC complete.
Renewal of sheet metal enclosure, single pole & neutral with two pin & earth plug and socket with one MCB single pole 20 amp, 240 volts complete. Make - Legrand / Schneider / Hager
Renewal of 36 mfd run capacitor for AC 1.5 Ton capacity including necessary electrical connections, lugs, insulation tape etc complete Make - Havells / Simcap / Unicop / Usha / Epcos
Renewal of 50 mfd run capacitor for AC 2.0 Ton capacity including necessary electrical connections, lugs, insulation tape etc complete Make - Havells / Simcap / Unicop / Usha / Epcos
Renewal of 10 mfd run capacitor for water cooler including necessary electrical connections, lugs, insulation tape etc complete. Make - Havells / Simcap / Unicop / Usha / Epcos
Renewal of 6.3 mfd capacitor for window AC & split AC including necessary electrical connections, lugs, insulation tape etc complete. Make - Havells / Simcap / Unicop / Usha / Epcos
Renewal of 4.0 mfd capacitor for desert cooler including necessary electrical connections, lugs, insulation tape etc complete. Make - Havells / Simcap / Unicop / Usha / Epcos
Servicing of split or window AC by cleaning the whole equipment, washing of filters, minor adjustments/repair, washing condenser unit any make and capacity complete.
Renewal of plug top 16 amps 3 pin complete.
Renewal of plug top 6 amps, 3 pin complete.
Renewal of 80-100 mfd start capacitor for AC of any specification including necessary electrical connections, lugs, insulation tape as required. Make - Tesla, Krishnomic, Keltron, BHEL, Havells
Renewal of 40-60 mfd start capacitor for water cooler of 40 litre cooling capacity of any make including necessary electrical connections, lugs, insulation tape as required. Make - Tesla, Krishnomic, Keltron, BHEL, Havells.
S&F in repairs remote circuit panel suitable for split type AC of 1.5/2.0 Ton capacity including necessary electrical connections, lugs, insulation tape etc complete. Make - Carrier, LG, Blue Star, Amtrex, Panasonic.
M&L for recharging of F22 gas in split type air conditioner 1.5 Ton capacity with specified process complete.
S&F in repair side shutter of GI sheet provided with vent slots for desert cooler of any type, size and make as required.
Renewal of swing motor for split type AC of any type and make as per existing.
Renewal of contactor relay for split type AC as per existing.
Renewal of ice freezer door for refrigerator 286 to 310 ltr capacity complete.
Renewal of fan blade for desert cooler complete.
Renewal of fan motor for any make desert cooler as required. Make - Khaitan / Summer King / Zenith / Metron / Bajaj.
Renewal of 3 pin metal socket & plug top for AC point single phase 240 volts, AC ISI marked.
Renewal of water cooler door lock made of CP brass with two numbers of key to suit the existing size and shape complete.
Renewal of MCB single pole 240 volts, 10 to 32 amps, 10 kA, 'C' series, ISI marked complete. Make - Legrand DX3 / Schneider / Hager
M&L for cutting of window grill for fixing of AC 1.5 / 2.0 Ton window type including making good the disturbed surface complete.
Renewal of front grill suitable for window type AC 1.5 Ton capacity of any make as required.
Renewal of copper tubing including brazing, flaring & testing of size 1/ 2" and 5/8" in required length including PVC insulation complete.
Renewal of fan motor of capacity 1/35 HP suitable for 40 to 60 ltrs cooling capacity water cooler complete. Make - AEI / CrompTon/ Bajaj / Usha / Khaitan / AUE
Renewal of front PVC grill of desert cooler to suit the existing opening and as per existing size complete.
S&F commercial plywood 4.0 mm thick provided in existing window upto double story bldg including cutting of plywood to opening size etc as required. (The area of plywood with external dimensions shall be measured for payment without deducting for central opening).
Renewal of blower motor 1.5 Ton window type AC, single phase all as per existing. Make – Usha / LG / Carrier / Blue Star / Voltas / Amtex / AUE.
Renewal of blower motor 2 Ton split type AC, single phase all as per existing. Make – Usha / LG / Carrier / Blue Star / Voltas / Amtex / AUE.
Renewal of submain wiring along with earth continuity conductor with PVC insulated FR multistranded copper conductor cable (Phase-Red, Neutral-Black, Earth-Green) drawing into and including concealed rigid non metallic PVC conduit medium grade, ISI marked ivory colour 20 mm dia along with accessories of following nominal sizes:-
2x4 sqmm + 1x2.5 sqmm earth wire.
2x6 sqmm + 1x4 sqmm earth wire.
Renewal of PVC flexible pipe (½”) 15 mm dia for desert cooler.
Renewal of blower motor for symphony strom 50i
Renewal of blower motor for symphony strom 100i
Renewal of honeycomb pad of symphony desert cooler stom 100i and 50 i
Repair ot circuit board of symphony desert cooler strom 50i, 100i
Carrying out scheduled maintanence and servicing of existing cooling appliances and accessories of any type any make & model every day as ordered including cleaning it's part, removing chemical corrosion, refixing it, rectifying the fault by repairing/replacing of unsv spare parts. Details of maintenace should be recorded in register .
Taking down defective ceiling fan,ceiling fan(BLDC), exhaust fan and wall mounting fan and air circulator fan of any make type & sweep including checking the serviceabilty of fan in the presence of MES representative and transporting the same to work shop for repairs and rehanging in position after repairs complete
M&L for opening of ceiling fan, exhaust fan and wall mounting fans and air circulator fans (any type, make & sweep) at workshop including refitting / assambling, testing after repairs/replacement of following unserviceable parts :
Supply only 3 core PVC insulated overall PVC sheathed standed copper conductor cable 0.5sq mm sizes
Supply only Ball bearing No 6201 suitable for fan of existing make, type & sweep complete make NBC/SKF/TATA
Supply only 4 MFD suitable for existing complete.
Supply only 2.5 MFD suitable for existing complete.
Rewinding of electric fan motor (Any make, type) with existing size of super enameled copper wire of good quality including treating with insulation varnish & heating including providing insulating material such as cotten tapes, insulating paper etc. for Ceiling fan of 1200 mm sweep complete.
All as per item No90 above but BLDC ceiling fan of 1200 mm sweep
All as per item No : 90 above but Exhaust fan of 450 mm sweep
All as per item No :90 above but Exhaust fan of 300/200/250 mm sweep
All as per item No : 908 above but Wall mounted Cabin fan up to 400 mm sweep
All as per item No : 90 above but Air circulation fan of 150/200/250/300mm sweep
Supply only PCB Controller for BLDC Ceiling fan of 1200mm sweep
Supply only Rotor magnet for BLDC Ceiling fan of 1200mm sweep
Supply only Remote for BLDC Ceiling fan of 1200mm sweep
Preparing old painted surfaces of ceiling fan of sweep 1200 mm /1400 mm of any make & type and applying one coat of synthetic enamel paint by spray machine & matching to the existing color including writing the MES No complete .
All as per item No 99 above but exhaust fans of sizes 200/250/300/350/450 mm sweep complete.
Prepainted down rod made out of medium grade MS tubing of size 15 mm bore of Down rod 300 mm long including cutting drilling, threading, welding etc. complete.
Prepainted down rod made out of medium grade MS tubing of size 15 mm bore of Down rod 450 mm long including cutting drilling, threading, welding etc. complete.
All as per item No 102 above but Down rod 600 mm long
Plastic canopy of ceiling fan 1200/1400mm sweep suitable for existing make complete.
MS clamps (Standard size) with rubber reel with MS nut, bolts, check nut & split pin suitable for ceiling fan 1200 mm sweep complate.
ALBA AC AND REF SERVICES
SATISH ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .