Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.8 LAccepted-AOC C 103 UGATI HEIGHTS NR SWAGAT RAINFOREST 1 KUDASAN POR RAO KUDASAN GANDHINAAGR 382421 GUJARAT | AHMADABAD | GUJARAT | 382421 | ₹10.8 L Quoted ₹11.1 L | L1 | Accepted-AOC L1 AND REASONABLE |
| 2 | L2₹11.8 L+₹71,952 (6.47%)Rejected-Finance 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | ₹11.8 L+₹71,952 (6.47%) | L2 | Rejected-Finance NOT L1 |
| 3 | L3₹13.5 L+₹2.3 L (21.1%)Rejected-Finance | ₹13.5 L+₹2.3 L (21.1%) | L3 | Rejected-Finance NOT L1 |
| 4 | L4₹13.5 L+₹2.4 L (21.7%)Rejected-Finance | ₹13.5 L+₹2.4 L (21.7%) | L4 | Rejected-Finance NOT L1 |
| 5 | L5₹13.7 L+₹2.6 L (23.3%)Rejected-Finance 0 ZARFIROZE COMPLEX OPP MANGO MARKET BEACHER ROAD VALSAD VALSAD GUJARAT 396001 INDIA UDYAM GJ 25 0010662 | VALSAD | GUJARAT | 396001 | ₹13.7 L+₹2.6 L (23.3%) | L5 | Rejected-Finance NOT L1 |
Tender Value
₹14.4 L
EMD Value
₹29,000
Closing Date
16 Jan 2024, 6:00 pmClosed
GE A JAMNAGAR
INFANTRY LINES JAMNAGAR
SPL REPAIRS TO TOILETS IN BLDG NO P-149 (SM BARRACKS) AND FLOORING AND WALL TILING IN ATTA SHED (PART OF BLDG T-06) AND BALANCE PORTION OF FLOORING IN RICE SHED (BLDG NO T-51) AT BG LINE AND INF LINE JAMNAGAR ( 17 AND 18 SWR(BUILDING)/JAM/23-24)
2023_MES_633669_1
8040
Open Tender
Civil Works
Item Rate
180 days
JAMNAGAR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE ARMY JAMNAGAR
₹29,000
1 Apr 2024
20 Dec 2023
18 Jan 2024
21 Dec 2023
16 Jan 2024
3 Jan 2024
Amount
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and as directed by Engineer-In-Charge.
M&L for 20-25 mm thick machine cut kota stone slab/tile, in flooring , polished over and including 15mm thick cement screed bed in cement mortar 1:4 screed base laid and jointed with cement slurry mixed with pigment to match the shade of the slab including rubbing and machine polishing complete all as specified and as directed by Engineer-In-Charge.
M&L M&L for 20-25 mm thick machine cut kota stone in riser of steps, skirting, dado, vertical partition, and pillar laid over and jointed with cement slurry mixed with pigment to match the shade of the slab including 10 mm thick rendering as in backing coat fo skirting/dado in CM 1:3 with on wall surface complete all as specified and as directed by Engineer-In-Charge.
Taking down cement plaster on brick/stone or concrete surfaces including racking out joints, hacking for key,scrubbing down with water to receive plaster complete all as specified and as directed by Engineer-In-Charge.
M&L for rendering 10mm thick on internal wall surface, fair faces of brick work or concrete surfaces in CM 1:6 finishing the surface even and even smooth without using extra cement. complete all as specified and as directed by Engineer-In-Charge.
M&L for preparation of newly plastered surfaces and applying two coats of oil emulsion distemper including one coat of suiatable primer including 3mm thick wall care putty in two layers on wall etccomplete all as specified and as directed by Engineer-In-Charge.
M&L for preparation of old distempered surfaces and applying one coats of oil emulsion distemper on wall etc complete all as specified and as directed by Engineer-In-Charge.
M&L coloured Glazed ceramic tiles in vertical surface 450mm X 300mm X 7mm / 350 x 250 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over & including 10 mm thick plaster in CM 1:4 complete all as specified and as directed by Engineer-In-Charge.
M & L Non skid coloured ceramic tiles 7-8mm thick area of each tiles exceeding .06 Sqm but not exceeding .11 Sqm, in floors etc. set and jointed in neat cement slurry mixed with water proofing liquid compound and pointed in white or coloured grouting chemical to match , over and including 15mm thick screed bed in CM 1:6 complete all as specified and as directed by Engineer-In-Charge.
Taking down chowkhat or frame with shutters (without taking off shutters from the frame) not exceeding 1.50 m Sqm complete all as specified and as directed by Engineer-In-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc. 1.5 Sqm and n exc. 4 Sqm each complete all as specified and as directed by Engineer-In-Charge.
M&L Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing, complete all as specified and as directed by Engineer-In-Charge.
M&L Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified and as directed by Engineer-In-Charge.
S&F SS butt hinges cold rolled medium weight, 100mm size complete all as specified and as directed by Engineer-In-Charge.
S&F Aluminium anodised barrel tower bolts, 100 mm long, of extruded section, complete all as specified and as directed by Engineer-In-Charge.
S&F 250 mm long aluminium anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium complete all as specified and as directed by Engineer-In-Charge.
S&F Extruded aluminium alloy handles 100mm long, fabricated type, anodised, complete all as specified and as directed by Engineer-In-Charge.
Taking up or down steel tubing and connections, including cleaning for refixing for removal the same of steel tubing 15mm bore complete all as specified and as directed by Engineer-In-Charge.
Taking up or down steel tubing and connections, including cleaning for refixing for removal the same of steel tubing 20mm bore complete all as specified and as directed by Engineer-In-Charge.
Taking up or down steel tubing and connections, including cleaning for refixing for removal the same of steel tubing 25mm bore complete all as specified and as directed by Engineer-In-Charge.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshades, sleves, lintels, etc and Cutting chases, pinning in , for concealed water tubing on brick walls, making good to facing where required and , not exc 10 cm girth. complete all as specified and as directed by Engineer-In-Charge.
Supplying and laying of 20 mm dia.(outer dia.) CPVC pipes SDR 11 pressure bearing capacity @ 23 deg C 28.12 kg/sq.cm with plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all connected brass fitting complete all as specified and as directed by Engineer-In-Charge.
Supplying and laying of 25 mm dia.(outer dia.) CPVC pipes SDR 11 pressure bearing capacity @ 23 deg C 28.12 kg/sq.cm with plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all connected brass fitting complete all as specified and as directed by Engineer-In-Charge.
Supplying and laying of 40 mm dia.(outer dia.) CPVC pipes SDR 11 pressure bearing capacity @ 23 deg C 28.12 kg/sq.cm with plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all connected brass fitting complete all as specified and as directed by Engineer-In-Charge.
S&F for 25mm bore ball brass valve, low pressure, with polythene float and fly nut complete screwed for iron pipe or brass ferrule complete all as specified and as directed by Engineer-In-Charge.
Demolition of cement (un-reinforced) in any position not otherwise specifically provided complete all as specified and as directed by Engineer-In-Charge.
M&L 75 mm thick Cement concrete type C-2, 1:3:6 (40 mm graded aggregate) as in plinth protection, path, hard standing, parking floors etc. finished even and smooth without using extra cement complete all as specified and as directed by Engineer-In-Charge.
M&L for 15mm thick rendering on floor and vertical side of sunken floor of brick/concret surfaces in CM 1:3 mixed with liquid water proofing compound @ 0.200 litre per bag of 50 Kg of cement and finished even and smooth without using extra cement. Note : Liquid water proofing shall be measured and paid for separately as "Supply only"
M&L Cleaning vertical and horizontal surfaces of sunken slab using wire brushing followed by sanding with emery paper for loose materials/dust and applying two coats of epoxy resin component (Dr. Fixit DAMPGUARD or equivalent) solution/mix using nylon brush pouring Base part in appropriate container followed by the Hardner part and mix thoroughly to attain homogeneous smooth paste and dilute the mixed compound with water in ratio 1 part Base: 1 part Hardner: 1 part water by slow addition and mix thoroughly until a brushable consistency is obtained, first coat will be allowed to dry for 6 to 8 hrs before application of second/final coat) incl curing treated surface for 24 hrs complete incl applying evenly a coat of blown bitumen @ 1.5kg/sqm over entire treated surfaces incl spout holesbefore filling lean concrete( preparing existing surface and applying apoxy reisin and hot blown bitumen over is measured and paid under this item) complete and all as specified as per manufacturer instruction.
M&L PCC type E-2 1:5:10 (40 mm graded stone aggr) as filling in sunken floor after applying appropriate treatment to side walls complete all as specified and as directed by Engineer-In-Charge.
M&L for 50mm thick PCC 1:2:4 type B-0 using 12.5 mm graded mixed with liquid water proofing compound @ 0.200 litre per bag of 50 Kg of cement in bottom of sunken floors complete all as specified and as directed by Engineer-In-Charge.
M&L for rendering 15mm thick in CM1:6 on stone masonry surfaces or surface other than faces of brick work, finished even and smooth without using extra cement complete all as specified and as directed by Engineer-In-Charge.
M&L for rendering 5mm thick in CM 1:4 mixed with liquid water proofing compound @ 0.200 litre per bag of 50 kg of cement, over and including 10mm thick rendering in CM 1:6 on stone masonary surfaces or surfaces other than fair faces of brick or one side of lathing complete all as specified and as directed by Engineer-In-Charge.
M&L for rendering 5mm thick in CM 1:3 on concrete surfaces in ceiling including finishing even and smooth without using extra cement complete all as specified and as directed by Engineer-In-Charge.
M&L Preparation of newly plastered surface of ceiling and applying 3 coat of white wash complete all as specified and as directed by Engineer-In-Charge.
M&L for preparation of plastered or unplastered surfaces of walls any width or girth etc and applying two coats of exterior weather coat paint (apex Ultima) white or tinted, over and including a coat of primer complete all as specified and as directed by the Engr-in-Charge
M & L for preparing New plastered surface and appling three coats white wash on wall complete all as specified and as directed by Engineer-In-Charge.
S&F in repairs PVC(SWR) pipe 110 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by Engineer-In-Charge.
S&F in repairs PVC(SWR) pipe 75 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by Engineer-In-Charge.
S&F 110mm PVC (SWR) branch piece, single (single Y) with access door equal or unequal complete all as specified and as directed by Engineer-In-Charge.
S&F in repairs PVC(SWR) bend any radius, 110 mm dia.provided with access door complete all as specified and as directed by Engineer-In-Charge.
S&F in repairs PVC(SWR) bend any radius, 75 mm dia.provided with access door complete all as specified and as directed by Engineer-In-Charge.
S&F in repairs 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent. complete all as specified and as directed by Engineer-In-Charge.
S&F in repairs PVC (SWR) junction double, (double T), equal or unequal provided wit access door complete all as specified and as directed by Engineer-In-Charge.
S&F fancy type CP bib taps, 15 mm bore with crutch or , screwed down, fixed as in repairs. complete all as specified and as directed by Engineer-In-Charge.
S&F stop valves chromium plated with long shank and cup (concealed type) 15 mm dia screwed down, high pressure with crutch or butter fly handle, screwed both ends, fixed as in repairs. complete all as specified and as directed by Engineer-In-Charge.
S&F vitreous china water closet (squat pan) orrisa pattern 580x440 mm size pan white with front or back inlet with integral 'foot rests including provn of lime concrete bedding including connections to 'flushing cistern/pipe complete all as specified and directed.
S & F in repairs white vitreous china wash down water closet pan, (pedestal pattern), white, with and including P/S Trap, PVC solid type seat cover etc complete all as specified and as directed by Engineer-In-Charge.
S&F in repair pillar tap, fancy type, cast copper alloy, with capstan heads, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nut screwed for iro pipe and fixed complete all as specified and as directed by Engineer-In-Charge.
S&F PVC connections 15 mm size with PTMT nuts of length 600mm complete all as specified and as directed by Engineer-In-Charge.
S&F 15 mm bore Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed by Engineer-In-Charge.
S&Fin repairs PVC valveless syphonic action type ,flushing cistern Low level white,with,with inlet ball valve ,float and handle 10 Ltr capacity including brackets complete all as specified and as directed by Engineer-In-Charge.
S&F in repair Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I.1000 ltr capacity including taking down old one complete all as specified and as directed by Engineer-In-Charge.
S&F Soap dish any type fixed to plugs with chromium plated brass screws. complete all as specified and as directed by Engineer-In-Charge.
S& F in repair sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and as directed by Engineer-In-Charge.
S&F corner glass shelf 300mm wide as per cat part No BEA-43 of make -Prayag or equivalent of make specified complete all as specified and as directed by Engineer-In-Charge.
S&F chormium plated Tubular towel rail, 20mm dia, D type, 60cm long between flangescomplete all as specified and as directed by Engineer-In-Charge.
S & F Grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40gms) complete all as specified and as directed by Engineer-In-Charge.
S&F 75 mm dia PVC (SWR) Nahani trap plain with grating incl jointing with solvent cement complete all as specified and as directed by Engineer-In-Charge.
S&F in repair Vitreous China urinals, bowl type (back or corner wall type),of size 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, ecuring urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed by Engineer-In-Charge.
S&F in repairs counter sunk Vitreous china wash basin (560x410x180mm), white including mounting on granite slab 20mm thick brass chromium plated perforated waste coupling/fittings 32mm dia with long screwed shanks and fly nut, flange end bedded in red lead cement and other end fixed and PVC waste pipe of 32mm bore and suitable length complete all as specified and as directed by Engineer-In-Charge.
M&L 20mm thick granite (of any type ) work (table rubbed and polished ) in steps, jambs, pillars, window cill, cooking platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed by Engineer-In-Charge.
Providing edge moulding to 20-25mm thick granite/kota stone any description of counter vanities etc including machine polishing to edge to give high gloss finish etc complete all as specified and as directed by Engineer-In-Charge.
Demolition of concrete of any description & in any position not otherwise specifically provided and removing debris outside MD Land.
M&L PCC 1:2:4 type B0 using 12.5 mm graded stone agg as in bedding/padding over Roof surfaces complete all as specified and as directed by Engineer-In-Charge.
M&L for Rendering 10 mm thick in CM (1:3) over concrete surfaces (roof) mixed with liquid water proofing compound @ 0.200 litre per bag of 50 kg of cement complete all as specified . NOTE : Liquid water proofing compound shall be measured and paid for separately as "Supply Only"
M&L for applying roof treatment on top of roof with APP modified membrane (minimum 3mm thick) weight not less than 3.00 Kg/Sqm and reinforced with non-woven polyster reinforcedment (centre core) with thermal insulation with polythene finish on upper side of membrane, laid by torch application method with overlaps 150mm on length side and 100mm on the width side as per manufacturer's instructions ove a coat of approved cold applied bituminous oil based primer (IS-3384) @ 300 gm/sqm and applying two coats of aluminium paint 0.20 litre/sqm complete all as specified and as directed by Engineer-in-Charge
Supply of liquid water proofing compound
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed by Engineer-In-Charge.
Demolition of Brickwork or stone/ boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles all as specified
M&L brickwork with flyash bricks, straight or curved on plan to to any radius in half brick walls,built in CM 1:4 complete complete all as specified and as directed by Engineer-In-Charge.
M&L for brick work with fly ash bricks, old size bricks, stright or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed by Engineer-In-Charge.
M&L for dubbing out average 15-18mm thick o irigular face of cement plaster wall (when specifically ordered in writing )
Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in soft/loose soil, complete all as specified and as directed by Engineer-In-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil, complete all as specified
M & L for removing excavated material (soils), exc. 250 m but n exc. 500 m and depositing where directed, complete all as specified and as directed by Engineer-In-Charge.
Demolition of reinforced Concrete in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspendedwork.
M&L Reinforced cement concrete (nominal mix) type B1 1:2:4 as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L formwork to edges & bottom of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floors and roofs, nexc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work complete all as specified and as directed by Engineer-In-Charge.
S & F TMT steel bars, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with & including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-In-Charge.
S & F TMTsteel deformed or twisted bars, 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with & including MS wire (annealed) not less than 0.9mm dia or securing with clips.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar (Internal dia of pipe in 200mm) complete all as specified and as directed by the Engineer-in-Charge.
M & L for reinforced concrete pipes, class NP2, 150 mm dia, laid and jointed complete with collars in trenches and jointed as specified complete all as specified and as directed by the Engineer-in-Charge
M & L for concrete bed to drain pipes of 150 mm bore, including packing under, and haunching against the sides of pipes after they are laid and tested cement concrete 1:4:8 type D-2 complete all as specified and as directed by the Engineer-in-Charge
M&L for providing precast cement concrete 1:2:4 type B-1 (using 20/15 mm graded stone aggregates) in precast manhole covers
Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site.
Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and as directed by Engineer-In-Charge.
Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and as directed by Engineer-In-Charge.
Taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M (Army) Jamnagar complete all as specified and as directed.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, including sunken MS pressed steel box 1.6 mm thick, 60 mm deep for housing switches, sockets etc covered with white laminated 3 mm thick hylam sheet cover ISI marked of suitable size , including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :-
(a) One light point controlled by one, one way switch 5 Amps
(b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
(c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
(d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
Description all as per item No 90 here in before but using 2.5 sq mm single core copper conductor cable of multistranded FRLSH, PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor FRLSH, PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly.
S & F for Switch Piano type single pole 5 amp, 230 Volts complete all as specified and directed at site.
S & F for Switch Piano type single pole 15 amp, 230 Volts complete all as specified and directed at site.
S & F for socket outlet 2 in 1 , 5 pin, 5 amp, 230 Volts complete all as specified and directed at site.
S & F for socket outlet 2-in-1, 5 pin, 5/15 amp, 230 Volts complete all as specified and directed.
S & F for Ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit
S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for MCB Single pole and neutral rated capacity 40 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
Labour only for refixing the celing fan/ Exhaust fan obtained from item No 131 above with replacement of unsv 3 core PVC insulated PVC sheated 3 core multistranded copper conductor cable of size 23/ 0.193 from ceiling rose to fan terminal including over hauling the fan, painting of ceiling fans complete with two coats synthetic enamel paint by spraying including filling cavities with filler after cleaning all dust etc. complete all as specified and as directed.
S & F for LED tube light fitting 2 feet x 10 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and as directed.
S & F for Energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired with warranty option of 5 years from date of installation and necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb complete all as specified and as directed. Make :- Bajaj Cat No BIBWP 10W LED or its equvalent in Philips, Wipro.
S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of three core multistranded copper conductor from ceiling rose to fitting complete all as specified and as directed. Make :- Make Bajaj Cat part No BCLAB 20W WH LED P, Wipro Cat part No LL20-281-XXX065-ALI or its equvalent in Philips, Havells.
S & F for energy efficient exhaust fan of 300 mm sweep made of metal body Ventil Air-DS type complete with louvers with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed. (Note:- Cost of suitable opening wall for fixing exhaust fan is deemed to be included in overall rate quoted)
M&L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in grond (earth pit not less than 2.25 mtrs below normal ground level) with the top edge of the plate not less than 1.5m below the normal ground level connected to GI wire 4.00mm dia protected by 15mm bore GI pipe light grade) and watering pipe 20mm bore GI pipe (medium grade) and chamber PCC (1:4:8) type D2( using 40mm grade stone aggregate), MS FUNNEL with wire mesh ,coping shall be PCC (1:3:6) type C1 using 20mm graded stone aggregate and RCC (1:2:4) type B1 using 20mm graded stone aggregate, pit cover 50mm thick reinforced with 8 mm MS bar at 80mm c/c both way in lieu of CI pit cover with lifting hook including excavation and earth work and removal of surplus soil complete all as shown in electrical plate No-3 of SSR part-I and as specified including earth plate packed around with charcoal dust common salt complete including GI sheet funnel, wire mesh, earth lead wire 4mm dia and earth lead connected to earthing test point/ main board. The GI earth wire 8 SWG under the earth and on pole/db upto a height of 1.5m shall also be protected by 15mm dia GI pipe (light grade ) and the GI pipe to be fixed with poles/wall by means of 02 Nos. FI clamp 25x3mm with nuts bolts and washer etc. incl taking down old earthing complete all as specified and directed by Engineer-in-Charge. Note :- GI earthing 4mm dia wire and protected pipe 15 mm dia of same size upto 7.5m shall deemed to be included into quoted rate
M/S Badri Electicals
JAY DWARAKDHISH ENTERPRISE
badri glass and construction
KRISHNA ENTERPRISE
SURAJ ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .