Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAccepted-AOC | ₹4.3 L Quoted ₹4.4 L | L1 | Accepted-AOC Being lowest tenderer |
| 2 | L2₹5.4 L+₹1.0 L (23.1%)Rejected-Finance | ₹5.4 L+₹1.0 L (23.1%) | L2 | Rejected-Finance Being other than lowest tenderer |
| 3 | L3₹5.5 L+₹1.1 L (24.5%)Rejected-Finance | ₹5.5 L+₹1.1 L (24.5%) | L3 | Rejected-Finance Being other than lowest tenderer |
| 4 | L4₹5.7 L+₹1.3 L (30.5%)Rejected-Finance | ₹5.7 L+₹1.3 L (30.5%) | L4 | Rejected-Finance Being other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹11,000
Closing Date
18 Jan 2021, 6:00 pmClosed
AGE(I) MES Dharamshala HP
AGE(I) MES Dharamshala HP
REPAIR/REPLACEMENT OF EARTHING, EARTH PITS, LIGHTENING CONDUCTORS AND CONNECTED WORKS AT MIL STN DHARAMSHALA
2020_MES_405440_1
AGE (I)/DSL-52/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Military Station Dharamshala
As Per eNIT
7 documents required · 7 mandatory
₹500
Yes
AGE(I) MES Dharamshala HP
₹11,000
Yes
8 Mar 2021
22 Dec 2020
20 Jan 2021
22 Dec 2020
18 Jan 2021
5 Jan 2021
Amount
Supply and fix (in replacement) sheet metal enclosure with new DB's suitable for MCBs of single pole and neutral 8 way, double door type with 200 amp rated bus bar, complete all as specified and directed by the Engineer-in-Charge. Note:- (i) Connections of the MCB's shall be done with appropriate size of brass/cooper thimble. (ii) The disturbed surface shall be match with existing surface at no extra cost. Make:- Havells/GM/Legrand.
Supply and fix (in replacement) MCB, SP, 6-32 Amp, complete all as specified and directed by the Engineer-in-Charge.
Supply and fix (in replacement) MCB, SPN, 6-32 Amp, complete all as specified and directed by the Engineer-in-Charge.
Supply and fix (in replacement) 1100 volts grade heavy duty cable, PVC insulated, stranded, aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable flat or circular stranded conductor of size 10 Sqmm, 2 core, complete all as specified and directed by Engr-in-Charge.
Earthing complete (in replacement) with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (earth plate not less than 2.25 mtr deep below the normal ground level) with top edge of plate not less than 1.5 mtr below the normal ground level connected to Galvanized earth wire 4mm dia by means of nuts bolts, washers, check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including angle iron of size 40x40x6mm and medium grade G.I. watering pipe 20mm dia with funnel and wire mesh and 15mm bore G.I. pipe, light grade protection pipe including excavation and charcoal common salt surrounded with 15cm all around the plate as shown in EP-3 of SSR Part-I , including cutting of existing wall/floor and making good surface as per existing, complete all as specified and directed by Engr-in-Charge.
Supply and fix (in replacement) existing unserviceable sheet metal enclosure with new DB's suitable for MCBs of triple pole and neutral 4 way, 415 volt, double door type with 200 amp rated bus bar with one incoming and 12 outgoing, complete all as specified and directed by the Engineer-in-Charge. Note:- (i) Connections of the MCB's shall be done with appropriate size of brass/copper thimble. (ii) The disturbed surface shall be match with existing surface at no extra cost. Make:- Havells/GM/Legrand.
Supply and fix (in replacement) MCB, TPN, 63 Ams, complete all as specified and directed by the Engineer-in-Charge.
Earthing complete (in replacement) with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to galvanised iron strip 32mm X 6mm (as earth lead strip), by means of bolt, nuts, check nuts and washer of G.I. and G.I. strip protected by provision of G.I. pipe, light grade, 40mm bore upto test point including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25 x 25 x 3 mm with lugs 2 Nos and with 6mm dia M.S. bar handle made to shape, G.I. medium grade, 20mm bore pipe for watering perforated at bottom 1.75 metres long placed on top edge of earth plate, including common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection to earth test point, complete all as specified and directed by Engr-in-Charge. Note: Item of earthing includes the cost of 7.5 mtr long galvanised iron strip 32mmx 6mm size and galvanised iron protection pipe of 40mm bore, light grade.
Supply and fix (in replacement) galvanized iron strip 32x6 mm and fixing screws burried in ground or above ground for test point, complete all as specified and directed by Engr-in-Charge.
Mahashakti Enterprises
KISHAN CONTRACTOR
M/S RANA BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .