Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹22.8 LAccepted-AOC VILL INDRANAGAR BANGLARMATH PO INDRANAGAR AGARTALA WEST TRIPURA | WEST TRIPURA | TRIPURA | 799002 | ₹22.8 L Quoted ₹23.8 L | 1 | Accepted-AOC VOLUNTARILY REDUCED RATE |
| 2 | 2₹24.4 LRejected-AOC | ₹24.4 L | 2 | Rejected-AOC HIGH RATE |
Tender Value
₹20.0 L
EMD Value
₹40,049
Closing Date
27 Jan 2026, 3:00 pmClosed
EXECUTIVE ENGINEER
Executive Engineer Internal Electrification Division, PWD (B) Udaipur, Gomati, Tripura
Construction of 10 bedded PHC Building in existing location with provision of meeting room in first floor along with Kitchen and Morgue at Garjee PHC Gomati Tripura Providing internal electrification thereof
2026_CEPWD_69331_1
EE-IED/UDP/20/2025-26
Open Tender
Electrical Works
180 days
GARJEE PHC, UDAIPUR
REFERRED TO TENDER DOCUMENTS
7 documents required · 7 mandatory
₹1,000
₹40,049
21 Feb 2026
17 Jan 2026
27 Jan 2026
17 Jan 2026
27 Jan 2026
17 Jan 2026
17 Jan 2026 - 22 Jan 2026
Wiring for light/ fan/ exhaust fan/ call bell point with 2x1.5 sq. mm PVC insulated copper conductor cable (FR) in PVC conduit (medium gauge) recessed in slab/ wall complete with 6/10 amps modular type switch, cover plate, GI box including necessary connection etc. as required.
Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2 x 1.5 sq. mm PVC insulated Copper conductor cable (FR) on modular concealed switch board with cover plate earthing the 3rd pin etc. as required.
Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2 x 2.5 sq. mm PVC insulated Copper conductor cable (FR) on modular concealed switch board with cover plate earthing the 3rd pin etc. as required.
2 X 1.5 + 1 X 1.5 sq mm
2 X 2.5 + 1 X 1.5 sq mm
2 X 4 + 1 X 1.5 sq mm
4 X 6 + 2 X 2.5 sq mm
4 X 16 + 2 X 6 sq mm
4 X 25 + 2 X 10 sq mm
Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:-
4 x 50 sq.mm:-
Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12"x 12" having locking arrangement including CC work, holes on earth pipe etc. as required:-
Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required.
Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12"x 12" having locking arrangement including CC work, holes on earth pipe etc. as required.
Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required.
Proving and fixing / Drawing 4.06 mm dia (8 SWG) Copper wire on surface or in existing G.I / PVC / Polythene pipe for loop earthing as required.
Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of 4.06mm (8SWG) dia G.I./ Copper wire for earth connection from earth electrodes etc as required.
Supply and fixing of 25mm x 3mm Copper on walls/ floor of the building for horizontal/ vertical network including necessary spacers and porcelain insulators at regular intervals.
Supplying and fixing of the following sizes PVC conduit (medium gauge) on surface with all accessories etc. as required.
19/20 mm dia
Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W).
Supplying & installation of 400 mm sweep AC wall mounting fan with plastic blade including connection etc as required:-
Supplying and fixing of the following electrical accessories including necessary connection etc. as required.
3mm thick bakelite sheet
Supplying and fixing of the following modular accessories including necessary connection etc. as required.
4 step fan regulator (1M):-
32 amps DP kit kat switch:-
Blank plate (1M):-
32 amps one way DP switch (2M):-
Supplying & fixing of 40 mm dia G.I pipe (medium gauge) cross bar for fixing of ceiling fan/luminaries including painting & necessary accessories etc as required.
Supplying & fixing of 40mmx6mm MS clamp for installation of ceiling fan/luminaries on cross bar including necessary accessories etc as required:-
Supplying & installation of 300 mm sweep metalic body exhaust fan including connection etc as required:-
Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:-
Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required:-
Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):-
Surface mounted box type batten suitable for single 18/20 watt integrated LED tube lamp (without lamp):-
Recessed round/Square shaped 18 watt LED downlight with integral driver and high quality polycarbonate diffuser:-
Recessed/Surface mounted 2ft x 2ft decorative 36 watt LED panel light with integral driver and high quality polycarbonate diffuser:-
Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-
9 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :-
18/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):-
Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):-
90 watt LED street light fixture with integral driver and secondary lens (IP 66):-
Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:-
40 mm dia:-
Supplying and fixing of M.S Box size (12"x8"x6") made of 3 mm size MS sheet with an arrangement of fittingMCB SP and Neutral link i/c rubber Gasket to the cover, water outlet duct to the below and locking arrangement.
Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required:-
3 core 4 sq mm:-
Drawing of armoured/un-armoured cable with proper saddling etc as required:-
Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/ 415 volts MCB/ Isolator/ RCCB (SP/ SPN/ DP/TP /TPN /FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required.
4 way SPN MCB DB (Double door):-
6 way horizontal TPN MCB DB (Double door):-
4 way horizontal TPN MCB DB (Double door):-
4 way vertical TPN MCB DB suitable for FP MCCB incomer upto 125 amps (Double door):-
6 way vertical TPN MCB DB suitable for FP MCCB incomer upto 250 amps (Double door):-
Supplying and fixing of following ratings MCB B/C curve having breaking capacity 10 KA in the existing MCB, DB including connection as reqd.
6 to 32 amps SP MCB:-
6 to 32 amps TP MCB:-
6 to 32 amps TPN MCB:-
Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):-
200 amps FP MCCB, Breaking capacity 36KA (Thermal Magnetic) :--
16 to 100 amps FP MCCB, Breaking capacity 16/18KA (Thermal Magnetic):--
Supplying and installation of powder coated steel sheet enclosure for 415 volts MCCB (TP/FP) complete with necessary connection etc as required:-
Enclosure suitable for MCCB above 100 amps upto 250 amps:-
Supplying and installation of change over switch of following ratings in existing enclosure/panel including necessary connection etc. as required :-
200 amps FP on load change over switch (Front handle with enclosure):-
Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:-
200 amps 415 volts TPN main switch (rewireable):-
Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:-
200 amps 415 volts four strip Copper busbar chamber 6 ways of size (610mmx410mmx150mm):-
Supplying and fixing of Copper terminal ends (LUGS) - long barrel of following sizes:
Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required:-
Excavation of earth for cable trench of 800mm depth & 300mm width in all kinds of soil including back filling of cable trench with the excavated soil with 20cm layer of sand, 3.5 nos bricks per metre for protection including ramming, consolidating to the original shape as per dirrection of Site Engineer :-
Supplying and installation of fuse unit kitkat/HRC/HBC of the following ratings in existing main switch/panel board including necessary connection etc as required:-
200/250 amps kitkat porcelain fuse unit with base(rewireable):-
Supplying and fixing of thermoplastic cable junction box with connectors suitable for following sizes cable : -
1.5 sqmm - 4 sqmm Cable:-
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.PDF
finance_70546.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.15 MB
EDNIT.pdf
Tender Documents • 2.89 MB
BOQ_70546.xls
BOQ • 0.43 MB
Download all tender documents and submit your bid