Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-AOC | L1 | Accepted-AOC lowest | |
| 2 | L2₹9.9 L+₹36,330 (3.82%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹10.3 L+₹77,846 (8.18%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹11.5 L+₹1.9 L (20.3%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹11.8 L+₹2.3 L (24.5%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹13 L
EMD Value
₹26,000
Closing Date
10 Jun 2023, 6:00 pmClosed
GE SAMBA
GE SAMBA
REPAIRS TO ALL TYPES OF FANS DESERT COOLERS WATER COOLERS AIR CONDITIONERS AND REFRIGERATORS AT MIL STN SAMBA
2023_MES_592926_1
GE/SMB/T-06/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SAMBA
REF NIT
8 documents required · 8 mandatory
₹500
Yes
GE SAMBA
₹26,000
Yes
18 Jul 2023
12 May 2023
12 Jun 2023
12 May 2023
10 Jun 2023
27 May 2023
12 May 2023 - 15 May 2023
Amount
Opening up of existing water cooler for Inspection by MES rep to ascertain due repair/replacement , of any size any type, at the site/ fixed in position and incl cleaning the tank, and testing after required repair /replacement including making necessary connection to the power point complete all as specified and as directed. Notes (i) Repair / Replacement of old defective spare parts/ items shall be measured and paid separately under respective items.if orederd by MES Rep (ii) Cost of transportation of water cooler/ spare parts of water cooler required being repair/replaced, from site to workshop for repair and workshop to site after repair shall be deemed to be included in quoted rates of respective item
Replacement of old unserviceable/ damaged hermatic sealed unit(Compressor) with new hermatic sealed unit, for water cooler of 40 liters capacity, complete all as specified and as directed
Replacement of old unserviceable/ damaged hermatic sealed unit (Compressor)with new hematic sealed unit, for water cooler of 80 liters capacity, complete all as specified and as directed
Replacement of old unserviceable/ damaged hermatic sealed unit (Compressor)with new hermatic sealed unit, for water cooler of 120 liters capacity, complete all as specified and as directed
Replacement of old unserviceable/ damaged hermatic sealed unit with new hermatic sealed unit (Compressor), for water cooler of 150 liters capacity, complete all as specified and as directed
Replacement/ filling of refrigerant gas (R-134a), suitable for water cooler of up to 80 liters capacity including testing against any leakage, complete all as specified and as directed
All as per serial item No-06 above but for water cooler of 120 liters capacity.
All as per serial item No-06 above but for water cooler of 150 liters capacity.
Replacement of old unserviceable condensing coil of water cooler for 40 to 150 lts of capacity complete all as specified and directed
Replacement of old unserviceable/ damaged starting relay with new starting relay for water cooler of 40, 80, 120 and 150 liters capacity, complete all as specified and as directed
Replacement of old unserviceable/ damaged over load protection relay with new over load protection relay for water cooler of any capacity, complete all as specified and as directed
Replacement of old unserviceable/ damaged starting condenser with new starting condenser of 40-60 mfd, for water cooler, complete all as specified and as directed
Replacement of old unserviceable/ damaged starting condenser with new starting condenser of 60-80 mfd for water cooler, complete all as specified and as directed
Replacement of old unserviceable/ damaged starting condenser with new starting condenser of 80-100mfd for water cooler, complete all as specified and as directed
Replacement of old unserviceable/ damaged starting condenser with new starting condenser of 100-120 mfd for water cooler, complete all as specified and as directed
Replacement of old unserviceable/ damaged running condenser with new running condenser of water cooler 10 mfd, complete all as specified and as directed
Replacement of old unserviceable/ damaged running condenser with new running condenser of water cooler 25 mfd complete all as specified and as directed
Replacement of old unserviceable/ damaged running condenser with new running condenser of water cooler 36 mfd complete all as specified and as directed
Replacement of old unserviceable/ damaged thermostat of any size for water cooler complete all as specified and as directed.
Replacement of fan motor 1/35 HP for water coolers any capacity complete all as specified and directed
Replacement of fan motor 1/10 HP for water coolers any capacity complete all as specified and directed
Replacement old damaged/ unserviceable PVC hose pipe with new PVC hose pipe, suitable for water cooler of any type and any capacity, complete all as specified and directed
Replacement old damaged/ unserviceable push cock with new push cock, chromium plated, for 15mm bore pipe, suitable for water cooler of any type and any capacity, complete all as specified and directed
Replacement of old unserviceable/ damaged ball valve with new ball brass valves, high pressure, with polythene float and flynut, screwed for iron pipe or brass ferrule and fixed for 15mm bore pipe, complete all as specified and as directed
Opening up of existing Refrigerator for Inspection by MES rep to ascertain due repair/replacement , of any size any type, at the site/ fixed in position and incl cleaning tinside and outside , and testing after required repair /replacement including making necessary connection to the power point complete all as specified and as directed. Notes (i) Repair / Replacement of old defective spare parts/ items shall be measured and paid separately under respective items.if orederd by MES Rep (ii) Cost of transportation of water cooler/ spare parts of water cooler required being repair/replaced, from site to workshop for repair and workshop to site after repair shall be deemed to be included in quoted rates of respective item
Replacement of old unserviceable/ damaged hermetic sealed unit with new hermatic sealed unit of 1/8 HP (Compressor), for refrigerator of 165-175 liters and 180-200 liters capacity, complete all as specified and as directed.
Replacement of old unserviceable/ damaged hermetic sealed unit with new hermatic sealed unit of 1/6 HP (Compressor), for refrigerator of 210-320 liters capacity, complete all as specified and as directed
Replacement/ filling of refrigerant gas (R-134a), suitable for refrigerator of 165-175 litres capacity including testing against any leakage, complete all as specified and as directed
Replacement/ filling of refrigerant gas (R-134a), suitable for refrigerator of 210-320 litres capacity including testing against any leakage, complete all as specified and as directed
Replacement of old unserviceable/ damaged over load protection relay with new over load protection relay, 1/8 HP for refrigerator of 165 to 320 liters capacity, complete all as specified and as directed
Replacement of old unserviceable/ damaged starting relay with new starting relay for refrigerator of 1/8 HP and 1/6 HP, complete all as specified and as directed
Replacement of old unserviceable/ damaged thermostate with new thermostate for refrigerator of any size and any descriptions, complete all as specified and as directed .
Replacement of old unserviceable/ damaged freezer door with new freezer door including proper insulation and rubber seal, for refrigerator of 165/175 liters capacity, complete all as specified and as directed
Replacement of old unserviceable/ damaged freezer door with new freezer door including proper insulation and rubber seal, for refrigerator of 210/320 liters capacity, complete all as specified and as directed
Replacement of old unserviceable/ damaged PCB with new PCB for refrigerator of any capacity and any description, complete all as specified and as directed
Replacement of old unserviceable evaporator of referigerator of any capacity complete all as specified and directed
Replacement of old unserviceable condensing coil of referigerator of any capacity complete all as specified and directed
Taking down carefully 1200/1400mm sweep ceiling fan of any make from the hook and carry to the wksp including rehanging after repair the same at existing position after cleaning dirt,oiling, greasing of fan complete all as specified and directed by Engr-in-Charge . NOTE :- Total service time from taking down to rehanging must not exceed 3 Days. APenalty of Rs 200.00 per fan per day ( or part there of) upto a maximum of Rs 2000.00 shall be imposed in case work not excueted within specified time.
All as per serial item No-38.00 above but for Exhaust fan 225mm to 450mm sweep.
All as per serial item No-38.00 above but for pedestall/wall mounting fan of any type and any description.
Strip opening of ceiling fan 1200 sweep and carrying out rewinding with proper grade/guage super enamelled copper winding wire so as to achieve original specifications i.e current rating and RPM including replacement of rubber real ,nut bolt,clamp as required and reasembling etc complete all as specified and directed by Engr-in-Charge. Note :- RPM test of ceiling fan with suitable tachometer will be done in the presence of Engineer -in -Charge.
All as per srl item No.41 above but ceiling fan of 1400mm sweep. Note :- RPM test of ceiling fan with suitable tachometer will be done in the presence of Engineer -in -Charge.
All as per serial item No-41.00 above but for wall mounting/pedestal fan of any type and any description.
Re-winding of exhaust fan/bracket fans/wall mounting fans/pedestal fans 225mm to 300 mm sweep after strip opening of motor with proper grade/guage of super enamelled copper wiring so as to achieve original specifications i.e current rating and RPM including all insulating materials, bushes etc re-assembling complete all as specified and directed by Engr-in-Charge. Note :-RPM test of ceiling fan with suitable tachometer will be done in the presence of Engineer -in -Charge.
Re-winding of exhaust fan/bracket fans/wall mounting fans/pedestal fans of 450 mm sweep after strip opening of motor with proper grade/guage of super enamelled copper wiring so as to achieve original specifications i.e current rating and RPM including all insulating materials, bushes etc re-assembling complete all as specified and directed by Engr-in-Charge. Note :-RPM test of ceiling fan with suitable tachometer will be done in the presence of Engineer -in -Charge.
Ball bearings suitable for ceiling fans of size 6201 complete all as specified and directed by Engr-in-Charge complete ,Make:SKF or technocommerically equivalent make of NBC/URB.
All as per srl item no 46 but of size 6202 complete,Make:SKF or technocommerically equivalent make of NBC/URB.
All as per srl item no 46 but of size 6203 complete,Make:SKF or technocommerically equivalent make of NBC/URB.
All as per srl item no 46 but of size 6204 complete,Make:SKF or technocommerically equivalent make of NBC/URB.
Replacement of PVC plug top 15 Amp, 240Volts (ISI marked) complete all as specified and directed make Anchor /SSK /Plaza /Havells
Replacement of PVC plug top 5 Amp, 240Volts (ISI marked) complete all as specified and directed make Anchor /SSK /Plaza /Havells
Taking out existing worn out /defective gun metal bush and Providing new gun-metal bush to the ceiling fans of any size/make incl reassembling and testing etc complete all as specified and directed by Engr-in-Charge.
Taking out existing defective/worn out condenser any size/make and Providing condensor of capacity 2.5 mfd ,220 Volts including making connections etc complete all as specified and directed by Engr-in-Charge, Make: USHA or technocommerically equivalent of make BAJAJ/HAVELLS.
All as per srl item No.53 here-in-before but of capacity 3.15 mfd capacity,Make: USHA or technocommerically equivalent of make BAJAJ/HAVELLS.
Taking out defective fan regulator any type and make and Providing Electronic step type fan regulator 5 stage speed variation ISI marked including making connection etc and cutting to the required size of 3 mm thick bakelite sheet where required complete all as specified and directed, Make :Havells or technocommerically equivalent of make Cona/ Plaza.
Replacement of old damaged/ un-serviceable metallic blades of ceiling fan with metallic blade of 1200mm/1400mm sweep size, complete all as specified and directed
Taking down worn out/defective metalic blades of exhaust fan/wall mounting/padestal fan off size 225mm to 300mm sweep and Providing new blades as per sample and make to the exhaust fan refixing in existing position etc complete all as specified and directed.
Taking down worn out/defective metalic blades of exhaust fan/wall mounting/padestal fan off size 301mm to 450mm sweep and Providing new blades as per sample and make to the exhaust fan refixing in existing position etc complete all as specified and directed.
Replacement old damaged/ unserviceable connection wire with new flexible, PVC insulated, multi-stranded, copper wire, 0.75 Sqmm, twine core, FRLS, complete all as specified and directed.
Taking out worn out/cracked canopy and Providing canopy with screws to the ceiling fans of any size/make etc complete. (Set of 2 pieces)
Replacement of old damaged/ unserviceable/ rusted nut, bolt with new nut, bolt of 10mm dia and 50mm long, mild steel including spilt mild steel safety pin, complete all as specified and directed
Replacement of old damaged/ unserviceable ceiling fan hanging clamp/ assembly with new hanging clamp/ assembly, mild steel including rubber reel, complete all as specified and directed
Rewinding for desert cooler motor with super enameled copper winding wire of same guage and weight including varnishing and heating, inter connection etc complete all as directed ( Cooler of iron body , standard size )
Replacement of old unserviceable/ damaged wooden wool pad with new wooden wool pad for three sides, for desert cooler of required specifications, complete all as specified and as directed( Cooler of iron body , standard size )
Replacement of old unserviceable/ damaged submersible water pump with new submersible water pump, AC operated, single phase, capacity 1/20 HP, 240 volts suitable for desert cooler, complete all as specified and as directed( Cooler of iron body , standard size )
Replacement of old unserviceable/ damaged Capacitors, 4.0 mfd, 50Hz, 230 Volts complete all as specified and as directed ( Cooler of iron body , standard size )
Replacement of old unserviceable/ damaged fan motor with new fan motor, AC operated, single phase, capacity 1.70 HP, 240 volts suitable for desert cooler and making necessary connection to power supply, complete all as specified and as directed( Cooler of iron body , standard size )
Taking out unserviceable /leakage/rusted bottom plate from the desert cooler and Providing new bottom plate of the fabricating with a 3 mm sheet as per sample ,complete all as specified and as directed ( Cooler of iron body ,standard size )
Replacement of old unserviceable/ damaged front grill with new front grill for desert cooler of any descriptions, complete all as specified and as directed ( Cooler of iron body , standard size )
Opening up of existing deep freezer for Inspection by MES rep to ascertain due repair/replacement , of any size any type, at the site/ fixed in position and incl cleaning tinside and outside , and testing after required repair /replacement including making necessary connection to the power point complete all as specified and as directed. Notes (i) Repair / Replacement of old defective spare parts/ items shall be measured and paid separately under respective items.if orederd by MES Rep (ii) Cost of transportation of water cooler/ spare parts of water cooler required being repair/replaced, from site to workshop for repair and workshop to site after repair shall be deemed to be included in quoted rates of respective item
Replacement of old unserviceable/ damaged hermatic sealed unit with new hermatic sealed unit for deep freezer 120 to 600 liters capacity, complete all as specified and as directed
Replacement/ filling of refrigerant gas (R-134a), suitable for deep freezer 320 liters capacity including testing against any leakage, complete all as specified and as directed.
Inspection of air conditioner window type 1.5/ 2.0 T cap , at the site and complete servicing as per manufacturers instructions incl , cleaning/ removing the dust and filter, blower, fan motor, washing/ cleaning the outer surface and testing including making necessary connection to the power point and presenting before MES rep to ascertain repair/replacement if any , complete all as specified and as directed by Engineer-In-Charge. Notes (i) Repair / Replacement of old defective spare parts/ items shall be measured and paid separately under respective items.if orederd by MES Rep (ii) Cost of transportation of water cooler/ spare parts of water cooler required being repair/replaced, from site to workshop for repair and workshop to site after repair shall be deemed to be included in quoted rates of respective item
Inspection of air conditioner spilt type1.5/ 2.0 T cap , at the site and complete servicing as per manufacturers instructions incl , cleaning/ removing the dust and filter, blower, fan motor, washing/ cleaning the outer surface and testing including making necessary connection to the power point and presenting before MES rep to ascertain repair/replacement if any , complete all as specified and as directed by Engineer-In-Charge. Notes (i) Repair / Replacement of old defective spare parts/ items shall be measured and paid separately under respective items.if orederd by MES Rep (ii) Cost of transportation of water cooler/ spare parts of water cooler required being repair/replaced, from site to workshop for repair and workshop to site after repair shall be deemed to be included in quoted rates of respective item
Replacement of old unserviceable/ damaged hermatic sealed unit with new hermatic sealed unit (Compressor), for air conditioner window 1.5 T, complete all as specified and as directed
Replacement of old unserviceable/ damaged hermatic sealed unit with new hermatic sealed unit (Compressor), for air conditioner window 2 T, complete all as specified and as directed
Replacement/ filling of refrigerant (R-32), suitable for air conditioner 1.5 T window type and any specifications including testing against any leakage, complete all as specified and as directed
Replacement/ filling of refrigerant (R-32), suitable for air conditioner spilt type 2.0 T and any specifications including testing against any leakage, complete all as specified and as directed
Replacement of old unserviceable/ damaged condensing coil with new condensing coil for air conditioner of 1.50 Ton capacity, window type complete all as specified and as directed
Replacement of old unserviceable/ damaged blower motor with new blower motor for air conditioner of 1.50 Ton capacity, window type, complete all as specified and as directed
Replacement of old unserviceable/ damaged PCB with new PCB, for split air conditioner of any capacity as per sample and any specifications, complete all as specified and as directed.
Remote controll device for window/split air conditioners size of 1.5/2.0 Ton as per sample complete all as specified and as directed.
Replacement of old damaged/ unserviceable connection wire with new PVC insulated, multi-stranded, copper wire, 1.50 Sqmm, 3 core, FRLS, complete all as specified and directed
Replacement of old damaged/ unserviceable connection wire with new PVC insulated, multi-stranded, copper wire, 2.50 Sqmm, 3 core, FRLS, complete all as specified and directed
Repair to voltage stabilizer of 5 KVA capacity, 240 Volts, single phase including M and L for Replacement of old burnt transformer winding with new copper winding wire of existing specifications for air conditioner of any capacity, complete all as specified and as directed
All as per serial item No-86 above but for voltage stabilizer 4.0 KVA capacity complete all as specified and as directed
All as per serial item No-86 above but for voltage stabilizer 2.0 to 3.0 KVA capacity.complete all as specified and as directed
All as per serial item No-86 above but for voltage stabilizer 0.50 to 1.0 KVA capacity.complete all as specified and as directed
Painting of ceiling fan 1200/1400 mm sweep complete with white synthetic enamal paint by spray painting to achive a smooth and uniform finish (one coat ) of the cleaning and fixing up cavation with filler and making MES No with black paint fo required size complete all as specified and directed (Note :- painting of fan/exhaust fan be done before delivery of fan by contractor to department with in situpted time of 3 days )
Lathe work/polishing/greasing and fixed new ball bearing in ceiling fan/exhaust fan complete all as specified and directed
Copper pipe of size 1/4" for 1.5/2 Ton split with insulation, complete all as specified and directed.
Copper pipe of size 3/8" for 1.5/2 Ton split with insulation, complete all as specified and directed.
Copper pipe of size 1/2" for 1.5/2 Ton split with insulation, complete all as specified and directed.
Copper pipe of size 5/8" for 1.5/2 Ton split with insulation, complete all as specified and directed.
Copper pipe of size 3/4" for 1.5/2 Ton split with insulation, complete all as specified and directed.
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
Vishav Karma Refrigeration and Electric Work
PARGAL CONSTRUCTION CO
m/s pankaj soni
M/S PRAJAPATI ENGINEERS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .