Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.5 LAdmitted-Fee/PreQual/Technical/Finance | L1 | Admitted-Fee/PreQual/Technical/Finance | ||
| 2 | L2₹3.6 L+₹6,500.06 (1.85%)Admitted-Fee/PreQual/Technical/Finance | L2 | Admitted-Fee/PreQual/Technical/Finance | ||
| 3 | L3₹3.7 L+₹21,000.21 (5.99%)Admitted-Fee/PreQual/Technical/Finance | L3 | Admitted-Fee/PreQual/Technical/Finance | ||
| 4 | Not Admitted-Fee/PreQual/Technical/Finance SARCH GANDERBAL JAMMU KASHMIR 191131 | GANDERBAL | JAMMU AND KASHMIR | 191131 | - | Not Admitted-Fee/PreQual/Technical/Finance Others-Non Responsive |
Tender Value
₹5.0 L
EMD Value
₹10,000
Closing Date
16 Sept 2026, 4:00 pmClosed
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX RAJ BAGH
Restoration of Huts at Tourist Resort Ningli B.W.O Electric work
2026_PWDJK_323586_1
NIT No.Fresh/147//2026-27 Dt 05/09/2026
Open Tender
Electrical Works
Percentage
Tourist Resort Ningli
Please refer Tender documents.
5 documents required · 5 mandatory
₹200
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹10,000
25 Sept 2026
5 Sept 2026
17 Sept 2026
5 Sept 2026
16 Sept 2026
5 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Wiring for Light point/Fan point/Exhaust fan/Bell point with (P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable, (Havells/Polycab/ Apar/ Anchor/Eq Make) in surface/recessed Conduits laid in slabs (Including Cost of Conduit 25mm) with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified/Schneider Zencelo/ Havells Crabtree/ Legrand Arteor/Anchor roma plus/ABB Tvisha (anti bacterial)/Eq.Make & items shall be approved before execution of work by SDO. | 64 | Point | 1,189 | ₹76,096 |
| 2 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required,ISO/IEC Certified of Schneider Zencelo/ Havells Crabtree/ Legrand Arteor/Anchor roma plus/ABB Tvisha (anti bacterial)/Eq.Make & shall be approved before execution of work by SDO. | 10 | No. | 402 | ₹4,020 |
| 3 | Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm HR-FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells Lifeguard/Polycab Green/ Apar/ Anchor Fireguard/Eq. Make) including Copper thimbles for originating/Terminating the wire. | 270 | Meter | 371 | ₹1,00,170 |
| 4 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified Schneider Zencelo/ Havells Crabtree/ Legrand Arteor/Anchor roma plus/ABB Tvisha (anti bacterial)/Eq.Make & shall be approved before execution of work by SDO. | 18 | No. | 657 | ₹11,826 |
| 5 | Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells Lifeguard/Polycab Green/ Apar/ Anchor Fireguard/Eq. Make) | 180 | Meter | 311 | ₹55,980 |
| 6 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Schneider Zencelo/ Havells Crabtree/ Legrand Arteor/Anchor roma plus/ABB Tvisha (anti bacterial)/Eq.Make & shall be approved before execution of work. | 12 | No. | 786 | ₹9,432 |
| 7 | Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells/Polycab/Anchor/ Apar/ Eq.Make) & shall be approved before execution of work (Including Cost of Conduit/Channel) | - | - | - | - |
| 8 | 2x10 sq.mm+ 1x6 sq.mm (P+N+E) for Power point Sub main in One run from Main Panel to Distribution Boards. | 20 | Meter | 773 | ₹15,460 |
| 9 | 2x2.5 sq.mm+ 1x2.5 sq.mm (P+N+E) for circuit wire | 170 | Meter | 311 | ₹52,870 |
| 10 | Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB DB Complete with connections. (L&T/Siemens/Legrand/Havells/ABB/Eq. Make) | 24 | No. | 285 | ₹6,840 |
stage.html
html • 0.02 MB
finance_1089619.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.51 MB
BOQ_1089619.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .