Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 239 VILLAGE TIKOLA P O JAINPUR SONIPAT SONIPAT HARYANA 131027 | SONIPAT | HARYANA | 131027 | Admitted-Finance |
| 2 | Admitted-Finance 47 PHASE 1 GIDC OPP MANGAL ESTATE NARODA AHMEDABAD GUJARAT 382330 | AHMADABAD | GUJARAT | 382330 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹80.4 L
EMD Value
₹1.6 L
Closing Date
21 Oct 2024, 3:00 pmClosed
Executive Engineer (M G) UJVN Ltd Kulhal Power Sta
Office of the Executive Engineer (M G) UJVN Ltd Kulhal Power Station
Renovation and refurbishment of Drainage-Dewatering pit at Kulhal Power House (3x10 MW)
2024_UJVN_76425_1
07/UJVNL/EE (MG)/KPS/2024-25
Open Tender
Electrical Works
Item Rate
180 days
Kulhal Power House
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,900
UJVNL, Kulhal P S (A/c No 1072002105502148 PNB
₹1.6 L
29 Oct 2024
30 Sept 2024
25 Oct 2024
30 Sept 2024
21 Oct 2024
5 Oct 2024
Amount
Supply Part ( A )
Supply of Cast Iron Gate Valve Size-250 mm double Flanged rising Spindle valve as per IS 14846 , , Body Dome and wedge in Cast Iron with 02 Nos. Spare MS Flanges (flange compatible with valve flange thickness), with nut-bolt of same size and same standard PN1.0 (PECO/Kirloskar/Leader/ L&T)
Supply of ELECTRIC SUBMERSIBLE AGITATOR SLURRY & SAND PUMP ,HP-30, KW - 22, RPM - 1450, Delivery Outlet - 200 mm, Solid Handling - 30mm ,Supply -3 phase, 50 Hz, AC Supply, 400v.,Pump Casing: ASTMA-48, Stator Casing: ASTMA-48,Impeller: 28% Hi-Chrome Iron, Wear Plate: 28% Hi-Chrome Iron,Agitator 28% Hi-Chrome Iron, Shaft: 403 Stainless Steel,Hardware: 304 Stainless Steel, “O” Rings: Nitrile Rubber,Mech. Seals: SC/SC (Upper & Lower), Cable:Waterproof/oil proof, rubber-insulated, neoprene-sheathed copper conductor,flexible cable, 20m length standard.Height - 1245 mm , Width - 578mm, Weight: 445 Kg,Discharge : 4800 LPM @ 15 Mtr Head,Make -Mody Pumps India Pvt Ltd /JASCO / Flygt
Supply of Faabricated Powder Coated Double Door Star Delta Suitable control panel for 30 HP pump includes MCCB TP 100A 1no.,VOLTMETER 500V SQ. 96*96 1no.,AMMETER 100/5 1no.,SQ 96*96 1no.,R,Y,B, INDICATER 3 no.,MCB SP 6A 1no.,CONTACTOR 3no., OVERLOAD RELAY 1no.,PUSH BUTTON ON/OFF -2 no.,PUMP ON-PUMP TRIP 2 no.,SPP, Water Level Controller with 3 probe for Automatically on off and Dry Run Protection, Auto-Manual Switch for smooth operation , Over Voltage and Under Voltage protection ,Emergency Stop button Switchgear make used in panel : Schneider/ L&T /Siemens/Minilec
Supply of M.S.Black pipe 8 mm thick confirming to IS: 3589 Gr. 330 with required flanged, nut bolts & packing sheet etc complete size 250 mm (Jindal/Tata)
Supply of Non Return Valve Size- 250 mm Double Flanged Non Return Valve as per IS 5312 Part-I with 02 Nos. Spare MS Flanges (flange compatible with valve flange thickness), with nut-bolt of same size and same standard PN1.0 ( PECO/Kirloskar/ Leader/ L&T).
Dismantling of old and damaged pipe line, flanges and related valve. Surface preparation for welding of pipe line and flange matching area . Fixing of 01 Nos.Cast Steel Gate Valve Size- 250 mm. Tightening of Pipe and valve. Supply and fixing of neoprene rubber sheet or champion sheet. Thoroughly cleaning of pipe line with the help of wire brushes etc
Fixing of Non Return Valve Size- 250 mm Tightening of Pipe and valve. Supply and fixing of neoprene rubber sheet or champion sheet. Thoroughly cleaning of pipe line with the help of wire brushes etc
Installation and Comissioning of 30 HP pump, Panel , 250 mm pipe upto Common Header , cable with required bend, flange, nut bolt, rubber gasket, fabrication , machining, with help of Crame. Manual chain pulley system , welder, beldar, supervisor, skilled electrician and othe tools and tackles.
Fabrication and fixing of 02 Nos. MESS Cover using MS angle ,C channel and Chequred Plate in PIT and stair case using MS Pipe 40 mm from up to down of PIT(10 Meter)40.0 M/140Kg. Including Supply of heavy duty Chequered Plate of 6 mm thickness, area- 33.0 sq.m/1584.0 Kg, heavy duty C Channel size of 150mmX8 mm, length- 90.0 M/519.0 Kg., heavy duty MS ANGLE of size 40 mm x 40 mmX6mm, length- 72.0 M/253 Kg. for frame work of complete structure for covering of pit with nut bolt as per site requirement
Supply and fixing automation panel including all accessories complete in all respect *Supply, Installation, Testing and Commissioning of Ultrasonic Level Sensor. * Supply, Laying and Cable Termination of Control Cable from PLC Cum DOL Stator Panel to Control Room. * Supply, Laying and Cable Termination of Instrument cable from Ultrasonic Level Sensor to PLC Cum DOL Stator Panel. * Supply, Installation, Testing and Commissioning of Remote Monitoring System. including all cost of material, labour and transportation required T&P and etc. to complete works
Aligning and existing of control panels of 02 nos. pumps. Including all nacessary accessories complete in all respact.
Applying primer then two layer of poly sulphide based epoxy painting with same color with code on all fabricated work and pipe.
Complete Testing of Gate Valves, Non Return Valves, Pumps and panel and fabricated work in presence of concerned engineer.
Transportation all supply materials and all and all machinery for SITC by manpower, hydra, crane to Kulhal Power House and its also included transportation of old pipe line, valves, pumps and other materials from sites to central store of Kulhal Power House.
Complete cleaning of Drainage- Dewatering pit along with necessary civil repairing concreting and wall painting.including all material, labour, T&P,etc. If it come out from the pit, sand and other meterial will be disposed only on the safe site in direction of Engineer incharge.
JASCO PUMP PVT. LTD (BID ID -339159)
MOHIT KUMAR CONTRACTOR (BID ID -340369)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .